Creating a niche of Neonatal Systems such as Neonatal Transport Systems and Neonatal Resuscitation Unit at its best, with utmost quality.


Neonatal Transport Systems
Enlarge View

Neonatal Transport Systems

We offer clients for the first time neonatal transport systems with CPAP that meet the accurate and controlled mean for neonatal transport systems. This unit fulfills basic needs of resuscitation thus ensuring life-saving action can be taken without delay. Some of its highlighting features include:

  • Controlled Resuscitation with CPAP module
  • Oxygen administration facility
  • Low pressure slow suction
  • Warming with Infrared Radiant Heat Source

Due to modular construction in radiant heat warmer, it also provides option of selecting from a range of controllers starting from basic Air Temperature controller (to control cradle temperature) to latest microprocessor based intensive care temperature controllers with easy view display option.

We introduce transcare, a versatile system for transportation of Newborn & high risk infants. It is designed for efficient transportation of infants in safety, while maintaining stable thermal environment for low birth weight as well as high risk neonates by:

  • Ambulance
  • Passenger Car
  • Inter-departmental transport in the hospital

Features:

  • Transparent hood structure for immediate visual checkup and reduces Radiant Heat loss by the infant
  • Thermal Maintenance by digital temperature controller
  • Dual safety mechanism is provided to monitor both rises in incubator & temperature over heating of heater
  • Standby heating function
  • Different power source may be used
  • Compact, Light weight and Sturdy
  • The trolley equipped with a smooth up and down mechanism

Specifications:

  • Electrical Requirement: 12 V DC Car battery or 230 V AC
  • Display: Skin or set temperature on large bright Led display
  • Temperature Controller: Electronic Temperature Controller
  • Optional Accessories: Oxygen powered suction, Oxygen Powered CPAP Resuscitator
  • Heating Controller: Electrical & Battery operated
  • Alarm: Over temperature alarm for skin temperature
  • Dimensions: L 40" x W 18.5" x H 48"

Transport Carrier:

We introduce transport carrier a low-cost neonate handling unit. It has been designed for carrying / transporting a baby from different wards or from hospital to home. It is a hand carrying system, simple & very light to use. It is also provided with hot water bags to keep the carrier warm.

Heat Shield:

We introduce radiant heat shield that prevents radiant heat loss for the Infant during Transportation in Transport Carrier or during long term intensive care in Incubator.

Dimensions: L19.5"x W 6.5" x H12"

Neonatal Resuscitation Unit

Neonatal resuscitation unit offered by us come with CPAP module, oxygen administration facility, low pressure slow suction and warming facility with infrared radiant heat source. Its modular construction as well as a wide range of controller selection option starting from basic air temperature controller (to control cradle temperature) to latest microprocessor based intensive can temperature controller with easy view display makes them one of the most preferred in the markets.


Mechanical Specifications:

 

  • Convenient working level with 6mm thick imported acrylic collapsible side support
  • Accessible from all sides
  • Acrylic Tray with Foam mattress
  • Trays & structure fabrication in steel
  • IV pole & Facility to take X-ray
  • Head up /down facility (continuous variable)
  • 3 Drawer storage cabinet mounted on heavy duty casters

Technical Specifications:

  • Power Source: 230 VAC +/-10%, 50Hz.
  • Control Method: Proportionate Power Control
  • Heater Capacity: 600 Watts
  • Light Source: 60 Watts bulb to Examine babies
  • Power Consumption: 850 Watts

Alarms:


  • Skin +1°C HI
  • Skin -1°C LO
  • Skin >38°C OVR
  • Skin/Air Sensor Failure PRB
  • Power Failure: Audio Visual
  • Resolution: 0.1 °C
  • Accuracy : 0.1 °C
  • Air +1.5°C HI
  • Air - 3°C LO
  • Air > 39°C OVR
  • Heating Failure HEAT OFF

Safety Cutoff:


  • Skin > 38°C
  • Air > 39°

Models Available:


  • On Front Page: Neonatal Resuscitation Unit Fixed Cradle without CPAP with 1 Drawer & Storage Capacity
  • MODEL A: Neonatal Resuscitation Unit Fixed Cradle with CPAP with Under Surface Phototherapy
  • MODEL B: Neonatal Resuscitation Unit with CPAP with Trolley
  • MODEL C: Neonatal Resuscitation Unit Fixed Cradle without CPAP
  • MODEL D: Export Quality Neonatal Resuscitation Unit Fixed Cradle without CPAP with 3 Drawers

"For further details see attachment"


Download


Neonatal Resuscitation Unit
Enlarge View




Contact us

Mr. Tanuj Shah (Manager)
No. 98, Pathare Wadi, Malvani Church, Marve Road
Mumbai, Maharashtra - 400 095, India
Telephone:+(91)-(22)-28806430/ 28893878

Contact via E-mail

Contact via Mobile

Contact via SMS

Home|About Us|Our Products|Site Navigation|Contact Us|Enquiry
Member IndiaMART.com © Meditrin Instruments. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry