NAAC ENERGY CONTROLS (P) LTD.

Energy Saving Products

We offer a wide range of qualitative products, which Offer energy saving and Power Quality management.

Power Factor Correction System
APFC Systems / PF Control
Tuned / Detuned Systems
Harmonic Filter System - For Office
Harmonic Filter System - For Industries
Harmonic Filter - Activcomp & Controller

Harmonic Filter, Activcomp Capacitor, Reactor & Software
Power Quality Analyzer- M4000
Power Analyzer - M90
Power Quality Analyzer - M2000
Power Analyzer - M40
Energy Audit Services

  Power Factor Correction System
Compact and smart Wall mounting P.F compensation series which offer very advance features and economically priced.

Features
  • Compact wall mounting series for small to medium industries.
  • Available upto 100 KVAR rating.
  • Suitable for both balanced & unbalanced load.
  • Advanced 3 phase controller with in built load analyzer.
  • Axial Flow Fan controlled through thermostat.
  • Up to 3 Year Warranty with Long Life LL-10 Capacitors.

NAAC P.F. Compensator series the power range goes from 12.5 kvar to 100 kvar. They are designed for small to medium load networks. They are highly reliable, cost effective solution for maintaining high network power factor.

They come equipped with following outstanding features:
  • In comer TP MCCB 35kA.
  • Micro processor based Neptune Phasetrac range of 3 phase P.F. Controller.
  • In built 3 phase Analyzer.
  • Compact wall mounting series with zinc passivated side clamps.
  • Front louvers with Axial Flow Fan & Thermostat.
  • Heavy Duty specially designed Neptune. Capacitor Duty Contractors with high thermal current withstand capacity.
  • MCBs for control circuit protection.
  • HRC Fuse or MCB (Series-D) for backup protection of capacitor banks.
  • High electrolytic grade Aluminium Busbar installed on SMC TP supports.

Electrical & General Characteristics:
  • Power range: 12.5 - 100 KVAR (440V)
    Mains voltage (working voltage): standard 440V (other voltage on request)
  • Rated frequency :50 Hz
  • Altitude: <2000 m a.s.l.
  • Relative humidity: 90% max. at 35OC
  • Duty :continuous
  • Temperature class:-25+ 55OC
  • Power supply line: Three-phase + ground + neutral (for 440V mains version only)
  • Relay current input signal: from CT on line/5A
  • Relay voltage input signal: picked up internally.

 Request for specifications and quotation...

Power Factor Correction System


APFC Systems / PF Control
  APFC Systems / PF Control
Life line series is our very old and reliable Floor mounting series for P.F correction. It comes with standard and many in built features:
  • Compact floor mounting modular series for medium to large industries.
  • Available upto 1000 KVAR rating.
  • Heavy Duty Long Life capacitors for Long life.
  • Special draw out ventilated racks for Capacitors.
  • Useful for both balanced and unbalanced load.
  • Advanced 3 phase controller with in built load Analyzer.
  • In built 3 phase energy analyzer with data logger.
  • Auto manual selection of Banks through selector switch.
  • Axial flow/centrifugal fan controlled.
Neptune-Ducati Make
Automatic Power Factor Correction system.


In Life Line Series P.F. Compensation System the power range goes from 50 kvar to 1000 kvar. They are designed for medium to large load networks. They are highly reliable, cost effective solution for maintaining high network power factor.
They are ultimate solution for compensation of unbalanced loads. The compensation is released by measuring the reactive power of the system, through 3 CTs from all 3 phases. This makes it best suited even for most unbalanced loads apart from balanced loads.
They come equipped with following outstanding features:
  • Incomer TP MCCB / ACB as per rating.
  • Micro processor based Neptune Phasetrac range of 3 phase P.F.Controller with in built Load Analyzer.
  • Inbuilt 3 Phase Energy Analyzer with Data Logger.
  • Modular floor mounting system.
  • Side/front louvers with Axial Flow/Centrifugal Fan & Thermostat.
  • Heavy Duty specially designed Neptune Capacitor Duty Contractors with high thermal current withstand capacity.
  • MCBs for control protection.
  • Auto/Manual selection through Sel. Switch.
  • HRC Fuses/MCCB-35kA (optional) for backup protection of capacitor banks.
  • High electrolytic grade Aluminium Busbar installed on TP supports.

 Request for specifications and quotation...



  Tuned / Detuned Systems
NAAC manufactures as per standard and Customized design complete range of Automatic or fixed Tuned and Detuned Harmonic Filtration equipment. They come with following standard features.
  • Floor mounting series for medium to large industries.
  • Available from 50 to 2000 KVAr rating.
  • Heavy Duty Long Life capacitors for Long life.
  • Low flux density copper wound reactors used for tuning or detuning applications.
  • Advanced 3 phase controller with inbuilt load analyzer.
  • 3 phase energy analyzer with data logger (optional).
  • 3 CT or single CT input for controller.
  • Auto manual selection through selector switch.
  • Axial flow/centrifugal fan controlled through thermostat.
  • Upto 3 years warranty with long life.
Components of Detuned Systems.
Controller - Single Phase or 3 Phase.
  • Measurement of A, V, PF, Cosj, W, Var, VA (SW, SVA, SVAr etc.)
  • Sense 1% of load current.
  • Auto/Manual mode selection with indicator light.
  • Automatic calculation of C/k value.
  • Program entry for targeted Cosj value.
  • Number of capacitor steps are user definable.
  • The consequent switching time between capacitor steps is adjustable from 2 to 50 sec.
  • C+/NORMAL/C- condition lights indicate actual system state.
  • Over Voltage Insufficient Compensation, Over Compensation state alarm indicator lights with output contact.
  • Adjustable programmable Over Voltage protection for capacitor banks.
  • Micro Controller based digital design complying with international standards.
  • Flush mounting with rear panel connectors.
  • Designed to use with Current T/F (.../5A).
  • Data Logger Module with Energy Analyzer (Optional).
  • Energy Analyzer with Data Logger is having facility to record and display all the 3 Phase parameters of mains where P.F.C. system is connected.

 Request for specifications and quotation...

Tuned / Detuned Systems


Harmonic Filter System - For Office
 
Large View
 
  Harmonic Filter System - For Office
Power Factor India Office buildings have undergone a significant modernization during the last years Large quantities of computer equipment (personal computer, printers, network servers) have been incorporated. All these equipment generate elevated levels of harmonics, which cause important problems in the electrical installation and the computer equipment itself. The triple harmonics (3rd, 9th etc.) are especially harmful as these sum in the neutral conductor and generate a high neutral current causing serious failures and damages in the installation. NAAC has developed a series of electromagnetic filters for elimination of harmonics named 'H.F. System'. These equipments are based on the cancellation and compensation of magnetic fluxes. The main advantage of the H.F. System is the absence of electronic components and capacitors. The H.F. System are therefore maintenance free, have an extremely long lifetime compared with other types of filters and are compatible with any electrical installation. Problem
  • Malfunctioning and failure in computer equipment.
  • Overheating of neutral conductors.
  • Low efficiency and overheating of UPS, transformers and cables of the installation.
  • Ripping of protections without apparent reason.
  • Interferences in communication networks.
  • Incremented power consumption.
Causes
  • Low quality electrical energy.
  • Elevated harmonic distortion in the voltage.
  • Elevated neutral - earth voltage.
  • High harmonic distortion in the current.
  • Excessive levels of 3rd and 9th harmonics in the neutral conductor.
  • Elevated true RMS current in the phases.
  • Low power factor due to harmonics.
  • Elevated losses in the electrical installation.

 Request for specifications and quotation...



  Harmonic Filter System - For Industries
During the last years there has been a large modernization of the industrial production processes and a fast evolution in power electronics, especially in the field of power converters such as variable speed drives for DC motors, frequency converters, UPS. All these equipments have a common characteristic which is the generation of harmonics currents that reduce the quality of the electrical energy.

NAAC completes its range of filtering inductors with a range of electromagnetic harmonic eliminating devices named H.F. System. The functioning of these devices is based on the cancellation and compensation of magnetic fluxes. The main advantage of the H.F. System in the absence of electronic components and capacitors. The H.F. System are therefor maintenance free, have an extremely long lifetime compared with other types of filters and are compatible with any electrical installation.

Problems
  • Malfunctioning and failure in electronic equipment.
  • Overheating and failure in transformers and cables.
  • Overload and failure in capacitor banks.
  • Low efficiency of transformer and cables.
  • Tripping of protections without apparent reason.
  • Interferences in communication networks.

Causes
  • Low quality electrical energy.
  • Elevated harmonic distortion in the voltage.
  • Notches and transients in the voltage caused by power converters.
  • Elevated harmonic distortion in the current.
  • Resonance in capacitor banks.
  • Elevated true RMS current in the phases.
  • Low power factor due to harmonics.

 Request for specifications and quotation...

Harmonic Filter System - For Industries
 
Large View
 


Harmonic Filter - Activcomp & Controller
  Harmonic Filter - Activcomp & Controller
Activcomp is state of Art Fast Thyristor Switched Harmonic filtration and P.F compensation equipment. It offers complete Power conditioning of Network which can used for both Detuned and Tuned applications. It has following features:
  • Power factor correction & harmonic filtration system (tuned & de-tuned).
  • Fast compensation unlimited number of transient free operation.
  • Low cost state-of the-art alternative for replace in electro-mechanical power factor solution.
  • Fast transient-free switching.
  • Saves energy & reduce electric billing.
  • Harmonic filtration.
  • Accurate power factor control, even the harmonics present.
  • Extreme long life expectancy.
  • Integral power, harmonic & wave form analyzer.
  • Controls the switching of as many steps as required at precisely the same time.

Background
  • The Activcomp is a state of the art, electronic switching system designed for Power factor Correction & Harmonic filtration.
  • Connection and disconnection of the capacitors to and from the network occurs at zero current crossing. This smooth connection avoids the transient effects typically created by electro mechanically switched PFC systems.
    The electronic switches do not wear out or deteriorate during the switching process and the capacitors are not adversely affected by transients. These advantages contribute to a much longer life expectancy compared with electro mechanically switched PFC systems.
  • The power factor is controlled very accurately by means of an advanced closed loop control & measuring unit, that takes into consideration all three phases and the effect of harmonics (1 through 63).

 Request for specifications and quotation...



  Harmonic Filter, Activcomp Capacitor, Reactor & Software
Very High quality Capacitor and Reactors are used in Activcomp system for P.F correction and Harmonic filtration. Capacitors are characterized by very high current bearing capacity of 4 X In and Low losses of 0.2 W / KVAr. As per tuning requirement of filter they are used in 525V or 690 V.

Neptune Filter Reactors are made out of high quality material and very stringent quality control. It has been designed with very low temperature rise and low flux density so that it can operate in worst conditions of ambient and harmonic overloads. They offer very good degree of linearity and low losses.

Activcomp system comes equipped with complete power quality management system. It works with Power IQ software. It provides following information:
  • Provides complete system remote control.
  • Real time measurement.
  • Time of Use.
  • Harmonic & Wave form graphic and tabular display.
  • Comprehensive Data Logging, including triggers and set point.
  • Power IQ displays the harmonic spectrum, both as a graph and table in addition to harmonic analysis parameters (THDs, K factor and Crest Factor) Compliance monitoring of international power quality standards, such as IEEE-519, allows easy network analysis.

 Request for specifications and quotation...

Harmonic Filter, Activcomp Capacitor, Reactor & Software


Power Quality Analyzer- M4000
  Power Quality Analyzer- M4000
Neptune M-4000 is the most advanced 4 th Generation Power quality Analysis system in the World. It has unmatched features and capabilities. It uses patented compression technology PQ-ZIP. It operates without any limitation of no. of parameter to be recorded, triggers and thresholds. It is capable of recording on it On Board memory all the parameters at 1024 samples per cycles for years. The device can be conclusively used for all faults in the network. You can virtually see the electricity with M-4000 technology. M-4000 offer following capabilities and features.
  • Target down time to 0% with M4000.
  • Realize huge savings with virtual control of the network power quality.
  • Reduce production and service down time losses.
  • Reduce maintenance cost of equipment.
  • Enhancing brand image/ reputation with better production quality & services.
  • Continuous every cycle logging of all power quality parameters.
  • Upto 1024 samples per cycle resolution.
  • No thresholds or other limitations.
New Concept in Power Quality Survey
The M4000 series brings revolution to your power. It stores all information all the time. The wave form of every cycle is continuously stored in on board memory for more than a year at high accuracy, allowing no gaps in data recording. In addition, a unique time synchronization algorithm assures that data from multiple locations is synchronized and displayed on the same time scale. The result is that every anomaly can be accurately analyzed and its source can be pinpointed definitively. Since all data is stored continuously and accurately over a long period of time, the M4000 is much more than an analysis device, but rather a full-fledged power quality data center.

 Request for specifications and quotation...



  Power Analyzer - M90
M90 power Analyzer is a compact , multi functional highly accurate (0.1 class accuracy) three phase analyzer , especially designed to suit the needs of power and energy measurement in electric panel. It is designed for power and energy metering, as well as power quality measurement and data logging. M 90 is capable of measuring active, reactive and apparent power as well as frequency, power factor, current, voltage, harmonics analysis and has a waveform graphic display .

Measurements Accuracy:

M90 has an autonomic measuring unit, which ensures accuracy of the power energy metering according to the international standard IEC 687/61036. Each cycle is sampled 1600 times.

The measurement accuracy of energy and energy components such as current, voltage, power and power factor is better than 0.1%

Power Quality Analysis:

Harmonic disturbances and bad power factor can cause massive damage to electrical facilities.

M90 enables monitoring & analyzing the supplied electricity quality to the facility. M90 also measures true power factor, which includes the influences of the harmonics disturbances. The harmonics spectrum analysis (up to the 31'st) can be displayed on the LCD.

Main Features:
  • Measurements accuracy according to international standard IEC 687/61036.
  • Accuracy better than 0.1% - Class 0.1.
  • Power quality analysis according to British standard EN50160.
  • Storing and displaying MIN/MAX values for the following measurements : Volts, Amperes, Powers, Frequencies and Power factor.
  • Maximum demand measurements & control through 6 outputs.
  • Optional Use for Automatic PF Control Up 6 stages.
  • Multilingual simply operated menus.
  • Energy data logging.
  • Serial communication Via RS-485.
  • MODBUS Open protocol.
  • State of the art graphic LCD display 128×64 resolution.
  • Sample Installation.

 Request for specifications and quotation...

Power Analyzer - M90


Power Quality Analyzer - M2000
  Power Quality Analyzer - M2000
M-2000 is very advanced (144×144 mm) Panel mounted Power Quality Analyzer. It is 0.2 class instrument and after following advance features.
  • Advance (cycle by cycle) Electrical Network Analysis.
  • Shows all voltage & current wave form.
  • Complete network harmonics analysis, up to 63rd harmonic.
  • High visibility, 5” graphics LCD screen with back light.
  • Displays neutral voltage and current.
  • Comprehensive data logging.
  • Feeder transformers analysis.
  • Compliance monitoring of international power quality standards.
  • Flexible design, allows system customization.
  • Upto 20-48 KB of flash memory.
  • A variety of isolated digital and analog inputs and outputs.
  • Multiple communication protocols.
  • Easy installation, configuration and use.

Metered Values
  • True RMS measurements
  • Advanced, real-time, cycle by cycle measurements, at 128 samples per cycle. Real-time values averaged over 8 through 256 cycles for easy reading.
  • Choice of models ranging from essential measurements only (Volts, currents, frequency and powers) to over 2000 electrical parameters.

Min/Max values
  • Four quadrant readings (power, power factor)
  • Displays neutral voltage and current.

Time-of-Use (TOU)
  • Time-of-Use information is automatically stored for each predefined period.

Power Quality
  • Wave form display and capturing, at 128 samples per cycle.
  • Harmonics analysis, up to 63rd harmonic (individual, THD, K and crest factors)
  • Sag/Swell recording (magnitude, duration and trigger events)

Compliance Monitoring
  • Compliance monitoring of international power quality standards.
  • These monitoring operate on all product series (e.g. the harmonics level is tested even if the meter doesn't include harmonics display).

 Request for specifications and quotation...



  Power Analyzer - M40
M-40 is designed to measure more than 250 electrical network parameters, including individual harmonics (up to 31th).
It has RS-485 MODBUS-RTU communication port, for communicating with the computer. M-40 has real time clock. 1MB internal memory (enables up to 6 months data recording) password for setup, Alarm Contact Output. Displaying maximum minimum and demand values.
4.20 mA/2-10 V Analog Output for PLCs. Energy Pulse Outputs and Digital Input/Output are line optional features of M-40
Thanks to the user –friendly M-40 Software! So, the acquired data can be monitored and reported in a single personal computer easily.
  • 3.6” LCD with backlight
  • VLN, VLL, I,
  • I, P.F. Hz
  • P,Q,S
  • P,Q,S, kWh, kVArh
  • Neutral Current Measurement
  • Up to 31th harmonic for current and voltage separately
  • THD V% THD I% Measurement with Bar Graphic
  • 1 MB Internal Memory
  • Programmable Demand Time (1-60 min.)
  • Alarm Contact Output
  • Energy Pulse Output
  • Computer Communication (RS-485 MODBUS RTU)
  • Real Time Clock
  • Password Protection
  • 4-20 mA Analog Output (Optional)

 Request for specifications and quotation...

Power Analyzer - M40


Energy Audit Services
  Energy Audit Services
NAAC offers comprehensive energy audit services for Industria l & Office Networks.

Energy Audit is a effective tool to check consumption patterns of various networks devices. It is normally carried out in two parts.
  • Preliminary energy audit

  • Detailed energy audit

Preliminary energy audit is carried out to check the areas of potential savings in the network. It also involves defining of scope of work which requires detail analysis & study.

Detailed Energy Audit is exhaustive depending on type of networks devices. It involves collection of data in detail from each and every area of operation, so as to calculate system efficiency. The collected data is then analyzed. The recommendations are based on these analysis to take corrective action.

In case of Capital investment cost benefit and ROI Calculations are also provided. Energy Audit is carried out by experts, who is certified by B.E.E.

 Request for specifications and quotation...






Copyright © NAAC ENERGY CONTROLS (P) LTD., All Rights Reserved (Terms of Use)
Developed by IndiaMART InterMESH Limited
Member IndiaMART.com