Differential Scanning Calorimetry/Differential Scanning Anal Multiple Mode Calorimetry Thermogravimetric Analysis / Thermogravimetry - TGA Thermo- Microbalance (TGA- Thermogravimetric Analyzer) TGA- Thermogravimetric Analyzer TGA-Thermogravimetric Analyzer TG 409 CD - Thermobalance (TGA-Thermogravimetric Analyzer) TG 429 CD - Thermobalance (TGA-Thermogravimetric Analyzer) Simultaneous Thermogravimetry - Differential Scanning Calori Dilatometry Dynamic-Mechanical Analysis / Dynamic Mechanical Thermal Ana Adiabatic Reaction Calorimetry Dielectric Analysis - DEA Thermal Diffusivity and Thermal Conductivity Refractory Testing Gas Analysis / Couplings Lab Measurements
 |
Thermogravimetric Analysis / Thermogravimetry - TGA |
 |
Manufacturer and supplier of a wide range Thermogravimetric Analysis / Thermogravimetry – TGA. Comprising an instrument generation that stands out due to unique design and revolutionary flexibility. Our products are easy and safe to use, with no hang-down wires or exposed fragile parts.
|
 |  |
 |
 |
|
|
 |
| | Thermo- Microbalance (TGA- Thermogravimetric Analyzer) TG 209 F3 Tarsus - Thermo-Microbalance (TGA-Thermogravimetric Analyzer) Together with the DSC 200 F3 Maia®, the new thermo-microbalance, TG 209 F3 Tarsus, represents a cost-effective overall concept, tailored not only to the quality assurance of polymers, but also to routine applications in the fields of organic chemistry, pharmaceuticals, cosmetics and food. This new basic instrument for thermogravimetric measurements offers already a resolution of 0.1 µg. The TG 209 F3 Tarsus operates between room temperature and 1000°C with freely selectable heating rates from 0.001 K/min up to 100 K/min. The accurate sample temperature is detected by a thermocouple in direct contact with the sample crucible. Through the reliable vertical construction with sample carrier lift, the thermo-balance as a top-loader, is easy and safe to use, with no hang-down wires or exposed fragile parts. - NEW: The fifth generation of the Proteus® measurement and analysis
software has been released. The calculated DTA-signal c-DTA® (option) not only is ideal for temperature calibration. During sample measurements it yields important information regarding endothermal processes (e.g. vaporization with mass loss or melting without mass loss) as well as exothermal reactions. For the TG 209 F3 Tarsus we offer an automatic sample changer (ASC) for up to 20 samples also in different crucible types. Cost-effective thermo-microbalance TG 209 F3 Tarsus
|
| |
|
 |
|
|
|
 |
|
 |
 |
|
 |
 |
|
 |
 |
|
 |
 |
|
 |
|