New Aquaria Electech Pvt LimitedPune, Maharashtra | IndiaMART Member Since: 2009 |
PRODUCTS & SERVICES |
Circuit Breakers (3)Electrical Contractors (1)Electrical Equipments (6)Electrical Switchgears (3)Electrical Transformers (2)Energy Meters (2)Relay Panels (1) | Electrical Equipments11/22 KV Ring Main Units & Load Break Switches![]() Our organization is engaged in offering extensive range of load break switch (PCESAIR) that is compact in design and reliable. For safety disconnection of heavy and small current, the dry type arc quenching chambers join two switch principles. The salient features of load break switch (PCESAIR) are given below:
Technical data standard accessories
Capacitor Switch![]() Our organization is engaged in offering extensive range of capacitor switch procured from our trusted and reliable vendors. We ensure that our range of capacitor switch is manufactured in accordance with the industrial standard. It consists of a number of capacitors that are switched by means of contactors. Our range of capacitor is used to store electric charge. This smooth switching technology provides superior performance for high inrush and frequency current, in addition to the “re-strike” free performance for either closing or interrupting operations. Some of the highlighting features of capacitor switch include:
Load Break Switch - PCESCOM![]() Construction The 11KV/22KV/33KV Load break switches are manufactured suitable for mounting on a panel. The panels are manufactured as per IS for Indoor or Outdoor application and as per customer requirement. The load break switches are manufactured in two types PCESAIR and PCESCOM. PCESCOM switch comprises of three pole bodies attached to main switch by means of cast resin supporting insulators as the supporters of the LBS live parts. The top insulators carry the fixed tulip contacts with the upper main terminals. In the middle of the tulip contact there is a quick-break contact pin – fixed arcing contact. The bottom insulators carry the contact housing with other terminals. The contact tube serving for the connection of the bottom main terminal with tulip contact is installed in the bottom pole assembly. The arcing contact in the middle of the main contact tube is flexibly joined to the piston for compressing the air. The contact tube moves via insulating arms attached on the shaft. The adjustable driving lever and toggle spring mechanism are attached on the shaft. Parallel to the main current path (upper contact-contact tube-contact roller-contact housing) the auxiliary current path is made up of quick break contact pin, quick break contact and arcing contact. Special Features
Optional Feature:
Oil Ring Main Unit![]() Experience The TRIDENT range of oil ring main equipment has a 25 year service history of trouble free operation with more than 1000,000 units in service world wide. The equipment is suitable for use in some of the world's more difficult climatic conditions including :
Compact Design The TRIDENT range is designed to provide a compact arrangement but still offer ease of installation. This has been achieved using well known combination of insulating oil and epoxy resin bushings/mouldings. Ease of Operation All switching and earthing operations can be carried out from the front of the unit. Position indicators are clear and conveniently located in line with the switching positions. Interlocks The switches are fully interlocked to prevent any possible mal-operation and subsequent dangerous operations. Mechanism The operating mechanisms are of the independent manual spring type for both main and earth switches ensuring speed of operation is independent of operator. Ring/Feeder Ring Switches are fault make, load break three position type 'ON', 'OFF' and 'EARTH'. Oil Ring Main Unit (ORMU)![]() Experience: The TRIDENT range of oil ring main equipment has a 25 year service history of trouble free operation with more than 1000,000 units in service world wide. The equipment is suitable for use in some of the world's more difficult climatic conditions including : Ambient Temperaturs from -20 to 55 degree centigrade Humidity up ti 100% Monsoon/Tropical Storms Corrosive Regions Oil Fields Open Cast Mines Compact Design : The TRIDENT range is designed to provide a compact arrangement but still offer ease of installation. This has been achieved using well known combination of insulating oil and epoxy resin bushings/mouldings. Ease of Operation : All switching and earthing operations can be carried out from the front of the unit. Position indicators are clear and conveniently located in line with the switching positions. Interlocks : The switches are fully interlocked to prevent any possible mal-operation and subsequent dangerous operations. Mechanism : The operating mechanisms are of the independent manual spring type for both main and earth switches ensuring speed of operation is independent of operator. Ring/Feeder : Ring Switches are fault make, load break three position type 'ON', 'OFF' and 'EARTH'. Ring Main Unit ( RMU )![]() We offer our clients wide range of ring main unit (RMU) that are used for H.T.side. Our range is offered with 3 numbers of switches (Circuit Breakers or Isolators or LBS). These are widely used for two inputs with mechanical or electrical interlock and also provided with one outgoing to ensure heavy load bearing capacity. Further our range can also be offered with one input with two outgoings. These are also used for redundancy feeder purposes.
|
| |||||||||||
| Companies | Products | Trade Leads | Tenders | Trade Shows | Travel |
© 1996-2012 IndiaMART InterMESH Limited. All rights reserved worldwide. |