Supplier of a wide range of laminar equipments such as laminar air flow hanging model, laminar air flow - vertical, laminar air flow - horizontal, laminar air flow table top model.
|
 
 

| Laminar Air Flow Hanging Model
For some applications it may not be ideal to use either a horizontal laminar flow hood or a vertical. For example, where an operator has to work on Celling / Filling machine . This simple and portable unit produces a unidirectional flow. A bacteria free air space at an inclination over the work area. It is specially designed to minimize the risk of transferred contamination. the unit is self supported from the floor and totally isolated from the Celling / Filling machine. Rest of the features are same as of LAMINAR . | FEATURES | | | | | | • | | Wooden/M.S Duley Power Coated /Stainless Steel Body. | | • | | HEPA Filter | | • | | Pre-Filter | | • | | Blower (Motor Blower Assembly) | | • | | U.V. Light | | • | | Fluorescent Lamp | | • | | Operating Switch | | • | | Pressure Gauge (Manometer) | | • | | Stainless Steel Table | | • | | High quality HEPA filter provides protection for the product (filtration efficiency of more than 99.97% at 0.3 micron. | | OPTIONAL ACCESSORIES:- | | | | | | • | | Particle Dust Count-Validation at site. | | • | | Timer for U.V. Lights. | | • | | Speed Regulator | | • | | Caster Wheels. | | • | | Magnahelic Manometer. | SPECIFICATIONS:- | | | Standard Size (Working Area) | 2' x 2', 3' x 2', 4' x 2', 6' x 2', 8' x 2' | | Air Velocity | 90 ± 20 cfm (Average) | | Filtration Elements | Main Filters : HEPA Filter Prefilter: Washable non-woven polyester fibers. | | Filter Efficiency | Main Filters : 99.97 at 0.3 micron Prefilter: Arrestance 90%, at 10 microns | | Work | Stainless Steel | | Noise Level | < 65 dBA | | Light Intensity | 800-1000 Lux | | Main Body | Wooden thick ply with wooden melamine. | | Power Supply | 220V Single Phase, 50 Hz. | | 
|
 
Laminar Air Flow - Vertical
The bench is made of thick ply board, and reinforced with teak wood where every necessary. All visible surface are laminated with white decolam Lamination. All interior surfaces are painted with air drying Epoxy paint. The filter seat has rubber padding for a perfect rubber to rubber sealing. The Front & side panels are made of Perspex sheet. At the delivery end, the unit is provided with Super Air H.E.P.A. Filters, Comprising of non-woven microfibre glass pleated media. The pleats are separated by corrugated aluminium foil separators. Initial pressure drop is less then 25mm W.C. at rated flow D.O.P. efficiency is better than 99.97% down to 0.3% microns particle size. The HEPA Filters are protected by a plastic/Aluminium grill. The unit is illuminated by fluorescent tube lights and is designed to provide a work area confirming to Class 100 of revised US Federal Standard 209B. Laminar Flow Cabinets are self-contained workstation units available in either horizontal or vertical laminar flow models. They can be placed within a clean room to create an ultra-clean environment or used to provide an individual clean air environment for small items not requiring a full-size Clean room. 
|  
 

|
 
 
 

| Laminar Air Flow - Horizontal
The bench is made of thick ply board, and reinforced with teak wood where every necessary. All visible surface are laminated with white decolam lamination. All interior surfaces are painted with air drying epoxy paint. The filter seat has rubber padding for a perfect rubber to rubber sealing. The front & side panels are made of perspex sheet. at the delivery end, the unit is provided with super air h. E. P. A. Filters, comprising of non-woven microfibre glass pleated media. The pleats are separated by corrugated aluminium foil separators. Initial pressure drop is less then 25mm w. C. At rated flow d. O. P. Efficiency is better than 99. 97% down to 0. 3% microns particle size. The hepa filters are protected by a plastic/aluminium grill. the unit is illuminated by fluorescent tube lights and is designed to provide a work area confirming to class 100 of revised us federal standard 209b. laminar flow cabinets are self-contained workstation units available in either horizontal or vertical laminar flow models. They can be placed within a clean room to create an ultra-clean environment or used to provide an individual clean air environment for small items not requiring a full-size clean room. . . | features | | | | | • | wooden/m. S duley power coated /stainless steel body. | | • | hepa filter | | • | pre-filter | | • | blower (motor blower assembly) | | • | u. V. Light | | • | fluorescent lamp | | • | operating switch | | • | pressure gauge (manometer) | | • | stainless steel table | | • | high quality hepa filter provides protection for the product (filtration efficiency of more than 99. 97% at 0. 3 micron. | | • | ultra-quiet noise level of not more than 65 dba. | | • | durable and easy to clean stainless steel work. | | • | cock for gase or vacuum line. | | • | work area properly illuminated by diffused glare free fluorescent light. | | optional accessories:- | | | | | • | particle dust count-validation at site. | | • | timer for u. V. Lights. | | • | speed regulator | | • | caster wheels. | | • | magnahelic manometer. | 

|
 
Laminar Air Flow Table Top Model
The bench is made of thick ply board, and reinforced with teak wood where every necessary. All visible surface are laminated with white decolam Lamination. All interior surfaces are painted with air drying Epoxy paint. The filter seat has rubber padding for a perfect rubber to rubber sealing. The Front & side panels are made of Perspex sheet. At the delivery end, the unit is provided with Super Air H.E.P.A. Filters, Comprising of non-woven microfibre glass pleated media. The pleats are separated by corrugated aluminium foil separators. Initial pressure drop is less then 25mm W.C. at rated flow D.O.P. efficiency is better than 99.97% down to 0.3% microns particle size. The HEPA Filters are protected by a plastic/Aluminium grill. The unit is illuminated by fluorescent tube lights and is designed to provide a work area confirming to Class 100 of revised US Federal Standard 209B. Laminar Flow Cabinets are self-contained workstation units available in either horizontal or vertical laminar flow models. They can be placed within a clean room to create an ultra-clean environment or used to provide an individual clean air environment for small items not requiring a full-size Clean room. 
|  
 

|
 
|
Scientific Instruments Digital Bursting Strength Testers Water Baths Laminar Equipments Laminar Air Flow Hanging Model Laminar Air Flow - Vertical Laminar Air Flow - Horizontal Laminar Air Flow Table Top Model Hot Plates Refractometers Scientific Equipments Digital Meter Shaker Laboratory Machines Equipments Analytical Balances Stainless Steel Deep Freezer Pharmaceuticals Heating Mantle Modulation Meters
 |