Laboratory Instruments

Avail from us a complete range of laboratory instruments that are used in various laboratory functions. These instruments are appreciated for good performance, durability, low power consumption and easy operation. Our range is designed as per the industry standards and are manufactured utilizing high grade material.


Digital pH Meter

Digital pH Meter


Special features
  • solid state circuit design
  • high degree of accuracy 0. 01 ph
  • high input impedance
  • check facility for quick analysis
  • non flickering display
  • built in stabilizer
  • auto polarity & decimal
  • compact & light in weight

 

it is a highly precision ph meter for continuous 0-14 ph reading & milvolts the ph meter is easy to operate as it is having least number of controls. Check facility saves time from every day buffer standardization and hence most suitable for quick analysis. It is a very sleek attractive finished instruments.


specification optilab ph - 901
  ph mode mv mode
range 0. 00 to 14. 00 ph 0 to + 1999 mv
resolution 0. 01 ph + 1 mv
accuracy 0. 01 ph + 1 digit 1 mv + 1 digit
input impedance 1012 ohms  
temperature range 0to - 100 c manual  
display 4 digits led  
polarity & decimal automatic  
supply 220 v ac + 10 % 50 hz  
dimenssion 250mm x 65mm x 130 mm  
weight 1. 5 kg in aluminium painted cabinet  
standard accessories ph electrode, stand, rod, clamp, buffers,
dust, cover and manual
 

 




Auto Ranging Digital Conductivity/ TDS Meter

Auto Ranging Digital Conductivity/ TDS Meter


* Auto Selection Of Range In 7 Steps.
    * Auto Matic Temperature Compensation.
    * Direct Display Of Conductivity.
    * Variable Cell Constant.
    * Inbuilt Tds Measurement.
    * Selectable Temperature Co- Efficient.





Digital Flame Photometer

Digital Flame Photometer


  • auto zero facility
  • selectable gain for full scale setting
  • filter selection through knob rotation
  • stable and reproducible results
  • easily accessible atomiser

 

 

specifications
sensitivity : sodium1 ppm fsd, potassium1ppm fsd,
calcium 10ppm fsd, lithium 1 ppm fsd
detector : photodiode
display : 2 ½ digit digital readout
air supply : preset regulator maintains stable air flow of 0. 6kg/cm2
combustion gas : lpg
atomizer : all metallic, axial flow type
burner : stainless steel
warm-up time : 15 minutes
recorder out put : 0-200mv for 100 counts
0-100mv for 100counts
power supply : 230v + 10 % 50 h
dimensions : 390 x 295 x 260mm
weight : 6kg
standard supply : basic unit with na & k filter air compressor 6 sample holders, atomizer cleaning wire flame igniter, dust cover, moisture trap and operation manual
variable gain amplifier : 12 bit dac microprocessor controller
reproducibility : + 2% fsd
filiter selection : microprocessor controller stepper motor
air supply : in built regulator preset to 0. 75 kg/ cm2
compressor : oil free 2 stages, portable (diaphragm type)
combustion gas : lpg
atomizer : all metallic, axial flow type
burner : stainless steel
power supply : 230 v + 10% 50hz
printer facility port : 80col with ibm compatible
dimensions : 350 x 235 x 325mm
weight : 7. 5kg
standard supply : basic unit with na k filter air compressor 6 sample holders, atomizer cleaning wire flame igniter, dust cover, moisture trap and operation manual
optional : ca, li filters at an extra cost

the new digital flame photometer is a simple and easy to handle analytical tool suitable for determination of sodium, potassium calcium and lithium. Narrow band interference filters are incorporated inside the unit in a filter wheel and are selectable by the rotation of knob. Photoreceptor fo photodiode type solid state electronics provide highly stable and reproducible results tdf -35 has less variable controls and an auto zero facility a preset air regulator incorporated in the unit maintains stable air flow from an oil free air compressor.


applications
  • oil refinery
  • agriculture and soil testing laboratory
  • chemical and fertilizers
  • foods and beverages




Up Flame Photometer

Up Flame Photometer


  • simultaneous determinations of na, k, ca , li in a single aspiration
  • automatic selection of filters
  • 5 point calibration
  • alpha -numeric lcd display
  • general & clinical facilities in single model
  • printer connection port available

 specifications

sensitivity : sodium1 ppm fsd, potassium1ppm fsd
calcium 10ppm fsd, lithium 1 ppm fsd
range of operation :
sodium : 0 to 100 ppm, 0 to 200meq
 
potassium : 0 to 100 ppm, 0 to 80 meq
 
calcium : 0 to 100 ppm, 0 to 100 ppm
lithium : 0 to 100 ppm, 0 to 100 meq
detector : photodiode
display : 16 characters, 2 lines alpha-numeric backlit lcd
parameters selection : 17 keys sealed membrance key board
results : automatic calculation with linear or quadratic curve & display in ppm or meq/li
memory back up : six months when no power is applied to the unit
variable gain amplifier : 12 bit dac microprocessor controller
reproducibility : + 2% fsd
filiter selection : microprocessor controller stepper motor
air supply : in built regulator preset to 0. 75 kg/ cm2
compressor : oil free 2 stages, portable (diaphragm type)
combustion gas : lpg
atomizer : all metallic, axial flow type
burner : stainless steel
power supply : 230 v + 10% 50hz
printer facility port : 80col with ibm compatible
dimensions : 350 x 235 x 325mm
weight : 7. 5kg
standard supply : basic unit with na k filter air compressor 6 sample holders, atomizer cleaning wire flame igniter, dust cover, moisture trap and operation manual
optional : ca, li filters at an extra cost

 

applications

  • clinical and pathological laboratory
  • cement steel and other industries
  • horticulture
  • water (natural, wastewater, effluent, river)
  • ceramics



Turbidity Meter

Turbidity Meter


Turbidity meter

 

Range : 0 - 1 ntu, 0 - 10 ntu
0 - 100 ntu, 0 - 1000 ntu
Accuracy : ± 2 % of f. S. In 0 1 & 0 – 1000 ntu range
(up to 500)
[due to nature of samples
readings may not be linear
above 500]
± 1 % of f. S. In 0 -10 & 0-100 ntu range
Dish size : 110mm dia
Reproducibility : with in ± 3% of f. S.
Detector : photo - cell
Display : digital panel meter
Calibration : with formazine standard solution
Power supply : 230 ± 10 % 50 hz, 30w





Dissolved Oxygen Meter

Dissolved Oxygen Meter


Description

oxygen meter
model: do-5510

  • p circuit, lcd with display unit.
  • dissolved oxygen range: 0 to 20 mg/l.
  • max. , min. , memory recall button.
  • do, oxygen in air, temp. , atc, auto cal. , % salt.
  • diaphragms & electrolyte included.
  • probe head with diaphragm set and electrolyte are included.
  • size: 180 x 72 x 32 mm. Rs - 232.



Chemical Oxygen Demand (COD Meter)

Chemical Oxygen Demand (COD Meter)
Highlights
  • ST-COD sealed tubes ready for use
  • Suppression of chloride interference up to 1000 mg/l
  • 3 Ranges:
    Low range: 0 – 150 mg/l, meets ISO 15705:2003-01
    Middle range: 0 – 1500 mg/l, meets ISO 15705:2003-01
    High range: 0 – 15000 mg/l
AL250 COD Vario

With a measuring range from 0 to 15,000 mg/l O2, the AQUALYTIC AL250COD VARIO photometer is suitable for waste water testing.

Two LEDs light sources with long-term stability (λ1 = 605 nm; λ2 = 430 nm, according to ISO 15705:2003-01), a waterproof sample chamber, a large digital display, and the user-friendly keypad ensure maximum operating reliability and convenience.


Setup AL250 COD VARIO

The AQUALYTIC AL250COD VARIO test setup allows highly sensitive and precise water testing with minimum effort. It measures the ST-COD concentration by photometric detection employing a linear relationship between absorbance and concentration.

After adding the sample to a AQUALYTIC COD VARIO tube test (LR, MR according to ISO 15705:2003-01), it is heated in the reactor and then analysed in the AL250COD vario photometer.

The COD-Setup comprises the AL250COD VARIO photometer, 25 tube tests for each of the two lower measuring ranges, a reactor for sample digestion, and a vial stand.


Waste water parameter COD

The chemical oxygen demand, ST-COD value, of water as determined by this dichromate method can be considered as an estimate of the theoretical oxygen demand, i.e. the amount of oxygen consumed in total chemical oxidation of the organic constituents present in the water.




Laboratory Oven

Laboratory Oven


purpose : designed, fabricated to suit various application in laboratory
construction : double willed, outer body of s. Steel (304 gr) and inner prime ss 316 grade door - metallic double walled dully insulated door fitted with standard set of hardware. Having provision for adjustable mesh / perforated trays.
insulation : gap of inner & outer walled filled with sufficiently thick thermal insulation.
heating : the heating elements are designed for low wattage density to works on black heat, are in coil form supported with refractory or long lasting s. S. Tubular heater are mounted at bottom to give uniform heating.
air circulation : motorized blower for maintaining uniform temp. Within chamber, blowing in air from bottom, no recalculation of air.
temp. Control : microprocessor based controller cum indicator with pt 100 sensor.
tamp. Range : 50°c to 200°c (higher version on spl. Request)
accuracy : ± 1° c or better.
inner size (inch) watt wire
tray
cap. /ltrs perfo. Tray 200°c higher temp.
300 ° c
          std. cgmp std. cgmp
(a)12 x 12 x12 750 1 27         p. O. R.
(b)14 x 14 x 14 1000 2 40         p. O. R.
(c)18 x 18 x 18 1500 2 90         p. O. R.
(d)18 x 18 x 24 1750 2 120         p. O. R.
(h)24 x 24 x 24 2000 3 220         p. O. R.
(i) 24 x 24 x 36 2500 3 325         p. O. R.

optional
  • safety blind controller
  • p. I. D. Controller with printer interface
  • p. I. D. Controller with pc interface.
  • protocol documents
  • oven with horizontal flow & / or top motor
  • precision oven / memmert oven with all sides heaters



Muffle Furnace

Muffle Furnace


Laboratory model - muffle furnace rectangular horizontal electrically operated furnace, is wound with high quality resistance wires fitted in metallic cabinet and insulated with cerwool insulation. Outer metal cabinet of heavy gauge dully painted with heat resistance paint specially developed for such equipment. Unit is fitted with thermal fuse which melt and break circuit to the heating element (safety) when working temp. Exceeded. Sunvic energy regulator is fitted for precise controls.

Temperature Range : 930°c / 1150°c (1200°c) unit works on 230 volts 
ac single phase.
Temp. Controls : digital time proportional controller
Power : 230 v, 50 hz, ac mains

Temp. Range 930 °c 1200 °c (1150 °c working)
Size rating pyrometer digital rating pyrometer digital temp.
9 x 4 x 4" 1600     2000    
10 x 5 x 5" 2000     2500    
12 x 6 x 6" 3000     3500    
18x 9 x 9" 6000     6500    
optional a t extra:- extra por
Blind temp. Controller with suitable sensor
Electronic temp. Controller cum indicator
Solid state fuse
Digital timer - 999 minutes
On site validation

 


Spare muffle with coil

Spare muffle wounded with heating elements and embedded with heat resistance Ceramic fiber wool insulation with extra long terminal for easy wiring.

Temp. Range rating 930 °c rating 1200 °c (1150 °c working)
9” x 4” x 4” 1600   2000  
10” x 5” x 5” 2000   2500  
12” x 6” x 6” 3000   3500  
18” x 9” x 9” 6000   6500  








Contact Us

Mr. Praful Jethva
No. 303, Silverline Complex, Opposite B. B. C. Tower, Sayajiganj
Vadodara, Gujarat - 390 001, India
Telephone:  +(91)-(265)-6509785/ 6640913



Home   |   Profile  |  Product Range  |  Trade Offers (12)  |  Job Vacancies   |   Site Navigation   |   Contact Us   |   Enquiry

Member IndiaMART.com © Optima Instruments. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry