Auxiliary Cables (600/1000 V)

Auxiliary Cables (600/1000 V)

All the Cables are insulated with PVC Type 5 Heat Resisting 85°C Compound and sheathed with PVC Type 9
Heat Resisting compound suitable for Cables operating at a maximum conductor temperature up to 90°C, which exceeds the requirements of BS 6346 - 1997. Cables as per BS 6346 - 1997 and IEC 502 - 1994. Core identification by number printing on white cores.

 
Product Code: (600/1000 V)

Insulated PVC Sheathed Steel Wire Armoured Cables

Insulated PVC Sheathed Steel Wire Armoured Cables

Copper Conductor PVC Insulated PVC Sheathed Steel Wire Armoured Cables (Cu/PVC/PVC/SWA/PVC)

Temperature Range  :   -25°C to + 70°C*.

  Standard                   :    As per IEC 60502-1, BS- 6346

  Conductor                 :    Annealed plain copper conductor solid as per class 1 and
                                         stranded as per class 2 of         
                                         IEC-60228. * Circular solid conductor (Class 1).

  Insulation                 :    Solid extruded PVC / A as per IEC- 60502-1.

  Color Code
  2 Core                        :    Red & Black;
  3 Core                        :    Red, Yellow & Blue;
  4 Core                        :    Red, Yellow, Blue & Black;
  5 Core & above           :    Black Cores with Number printing.

  Bedding                     :    Extruded PVC compatible with the operating temperature of                                           the conductor.

 Wire armor               :    Galvanized Steel wire as per IEC-60502-1.

  Outer sheath            :    Extruded PVC Type ST-1 as per IEC-60502-1, Flame
                                         retardant.

  Applications               
  Can be used indoors or outdoors in cable ducts, cable trays, conduits or underground
  locations under mechanical stresses in power and switching stations, local distribution
  systems, industrial plants and commercial buildings.

XLPE Insulated PVC Sheathed Steel Wire Armoured Cables

XLPE Insulated PVC Sheathed Steel Wire Armoured Cables

Copper Conductor XLPE Insulated PVC Sheathed Steel Wire Armoured Cables

CU/XLPE/PVC/SWA/PVC is a XLPE insulated, PVC bedded, steel wire armoured and PVC
sheathed auxiliary cable with circular, compacted and stranded annealed copper conductors
complying with BS 6360 class 2. The cable is designed according to BS 5467. The armour is
a single layer of galvanized steel wires.
*Circular solid conductor (Class 1).

Double Xlpe Insulated Single Core Cable

Double Xlpe Insulated Single Core Cable

XLPE Insulated and PVC Sheathed.
Voltage Rating: 600/1000V.
Outer Sheath: Black.
Manufactured as per BS.5467/1989.

Non- Sheathed Cable

Non- Sheathed Cable

Single- Core Mica Tape Fire Barrier, LSZH Insulated, Non- Sheathed Cable (450/750v & 600v/1000v)

Application:          This cable is used in fire extinguishing systems, sprinkler systems,
                             control panels, and exit Lights in high-rise buildings, hotels, hospitals,
                             sub-ways, and public facilities.

Voltage rating:     450/750V & 600/1000V

Construction:       Plan annealed copper, Mica tape fire barrier, LSZH Compound
                             insulated cable

Insulation color:  Range or as per order

Specification:       Refer BS7211, BS6387, SS299-1, IEC60331, IEC60332-1,
                             IEC60332-3, IEC60754, IEC61034

Single Core Flexible Cable (H05&7v-K) Pvc Insulated

Single Core Flexible Cable (H05&7v-K) Pvc Insulated

A Single Core Cable with flexible stranded copper conductors, which are PVC insulated and are rated for a temperature of up to 105°C.

 
Product Code: (H05&7v-K)

Single Core Solid Wire Pvc Insulated

Single Core Solid Wire Pvc Insulated

Single core solid PVC insulated cables manufactured As Per BS: 6004.
Rated Voltage 300/500V for H05 V-U or 450/750 V for H07V-U
 
Description:
Single Core Cable with solid annealed copper conductors, PVC insulated, suitable for voltage up to 1000 volt AC and up to 750V to earth DC
 
Conductor:
Plain annealed circular copper conforming to IEC-228, class 1

Insulation:
PVC type TI Ito BS-6746 rated temperature 70°C; also available PVC rated temp. 105°C

Applications: 
In dry rooms, in apparatus, switch and distribution boards, for laying in conduit on and under plaster and on insulating supports above plaster.
Switchboard cabling and installations in machines (H05 V-U)
Domestic and industrial installations (H07 V-U)

Remarks:
We also manufacture this cable according to AS/NZS, SANS, VDE Standard and also can manufacture as per buyers specification.

Single Core Stranded Wire Pvc Insulated

Single Core Stranded Wire Pvc Insulated

Single Core Cable with Stranded copper conductors, PVC insulated, suitable for voltage up to 1000 volt AC and up to 750V to earth DC

D.C. Cable

D.C. Cable

Application Suitable for D.C. power supplies on Telecom equipment and power applications where flexibility is required.

Standards Generally to BS6004

Conductor Flexible class 5 copper conductors to BS6360

Insulation PVC (Type TI 1 to BS7655)

Sheath PVC (Type TM1 to BS7655) with oxygen index > 30% Flame retardant to BS4066 Part 1Meets requirements for flammability as required by BT specification M231

Color Blue/Blue, Grey/Grey, Green/Yellow, Brown/Brown, Special colors to order
Voltage Rating 450/750V, 10-35mm2 600/1000V, 50mm2 +

Temperature Rating0 to +70°C

Minimum Bending Radius Up to 50mm²: 3 x overall diameter Above 70mm²: 4 x overall diameter.

Fire Resistant Cable

Fire Resistant Cable

This cable is designed for areas where the integrity of the electrical circuit is critical to maintaining the power supply. Applications can be found in: emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.

Voltage rating:   
600/1000V

Construction:     
Plain annealed copper, Mica tape fire barrier, XLPE Compound insulated, Unarmoured or Aluminium wires armoured, LSZH Compound sheathed cable

Insulation color:   
Natural

Sheath color:  
Orange/Black or as per order.

Specification:
BS6724, BS6387, SS299-1, IEC60502-1, IEC60331, IEC60332-1, IEC60332-3, IEC60754, IEC61034

Fire Resistant Cable

Fire Resistant Cable

Mica Tape Fire Barrier, XLPE Insulated, LSZH Sheathed, Fire Resistant Cable (300/500v Single-Core)

Application:  
This cable is designed for areas where the integrity of the electrical circuit is critical to maintaining the power supply. Applications can be found in: emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.  

Voltage rating
300/500V  

Construction:  
Plain annealed copper, Mica tape fire barrier, XLPE insulated, LSZH Compound sheathed cable.

Specification:
  Refer IEC60502-1, BS6387, SS299-1, IEC60331, IEC60332-1, IEC60332-3, IEC60754,
  IEC61034

As Per (H07 Rn-F 450/750v H D 2 2. 6)

As Per (H07 Rn-F 450/750v H D 2 2. 6)

Construction
*Copper conductor acc. to IEC, class 5 (tinned up to 16 mm2)
*Separator tape (only for sections above 16 mm2)
*EPR rubber insulation acc. to HD22, type El 4
*Elastomeric outer sheath acc. to HD22, type EM2
*Very good behavior to variations of outdoor temperature: mobile use: -25 ... + 50°C

Copper Conductor PVC Insulated PVC Sheathed Cables

Copper Conductor PVC Insulated PVC Sheathed Cables

Copper Conductor PVC Insulated PVC Sheathed Cables (Cu/PVC/PVC)

1. Circular solid conductor (Class 1)*
2. Conductors 10 to 16 Sqmm circular stranded (Class 2).
3. 25 Sqmm and above shaped stranded conductors (Class 2).
4. All the Cables are Insulated with PVC Type 5 Heat Resisting 85°C compound and sheathed
    with PVC Type 9
5. Heat Resisting compound suitable for Cables operating at a maximum conductor
    temperature upto 90°C, which exceeds the requirements of BS 6346 - 1997 and IEC
    502 -1994.
6. Cables upto and including 6 Sqmm generally to BS 6346 -1997 and IEC 502 - 1994.
    Cables, 10 Sqmm to 400 Sqmm conform generally to BS 6346 - 1997

Plain Copper Conductor (Cu/Pvc/Pvc Or Cu/Pvc/Nylon)

Plain Copper Conductor (Cu/Pvc/Pvc Or Cu/Pvc/Nylon)

Definition:
THHN: Thermoplastic insulated, High Heat resistant, Nylon Jacketed cable, 105° C dry locations.

Rated Voltage:
Working Voltage up to 600V

Conductor:
Annealed Solid or stranded copper wires

Insulation:
Polyvinyl Chloride (PVC) Rated 105° C

Jacket:
Nylon jacket provided over PVC insulation for protection from abrasions and scratches at the time of pulling through conduits. It also serves as a protective shield against oil, gasoline and chemicals.

 
Product Code: (Cu/Pvc/Pvc Or Cu/Pvc/Nylon)

Heat Resisting Pvc Insulated And Pvc Sheathed Flexible Cords

Heat Resisting Pvc Insulated And Pvc Sheathed Flexible Cords

Voltage Rating:                 300-500 volts (BS 6141)
                                          As per B.S. 6500/1994.
Operating Temperature:  Maximum 85°C
Conductor Identification: 2 Core = Brown / Blue, 3 Core = Brown/Blue /Green-Yellow
                                          4 Core = Brown / Blue / Black / Green-Yellow
                                          5 Core = Brown / Blue / Black / Black / Green-Yellow 

Construction: Flexible plain annealed copper conductor, heat resisting P.V.Cinsulated and heat resisting PVC Sheathed. Sheath Colors as per requirement.

PVC Insulated PVC Sheathed Multicore Flexible Cables

PVC Insulated PVC Sheathed Multicore Flexible Cables

PVC Insulated PVC Sheathed Multicore Flexible Cables (600/1000v & 300/500v)

PVC Type TM2 as per BS 7655
Temperature rating 70º C (PVC Rated 85º C or 105º C on request. Meets IEC 332-1 Flame Test.)

Single Core Flexible (As Per N07v-K 450/750v)

Single Core Flexible (As Per N07v-K  450/750v)

I - Conductor:  Flexible copper class 5
II -Insulation:  PVC type R2 (CEI 20-11).

 
Product Code: (As Per N07v-K 450/750v)

Indoor Telephone Cables Shielded

Indoor Telephone Cables Shielded

Specifications As per UL-444, EIA/TIA 568 B
Conductor
Soild Annealed Bare Copper Conductor
Insulation
Extruded Soild polyethlene.
Assembly
Pairs twisted with staggered lay technique. Twisted pairs are bundled into units of 25 pairs ( subunits comprise 12/13 pairs) and cabled and covered with a polyester tape binder. An aluminum Mylar tape is appleid with an overlap for 100% coverage with a tinned copper drain wire.
Outer sheath
Grey Colored flame retardant PVC.
Applications
Used for voice, data and local area network application up to 16 MHz.

Indoor Telephone Cables Unshielded

Indoor Telephone Cables Unshielded

Specifications As per UL-444, EIA/TIA 568 B
Conductor
Soild Annealed Bare Copper Conductor
Insulation
Extruded Soild polyethlene.
Assembly
Pairs twisted with staggered lay technique.
Twisted pairs are bundled into units of 25 pairs (subunits)
Outer sheath
Grey Colored flame retardant PVC.
Applications
Used for voice, data and local area network application up to 16 MHz.

Aluminium Power Cable

Aluminium Power Cable

Application: Trackside signalling power supplies. 
Standards: As per BR880, BS5467, BS6346 
Conductor: Sector shaped solid aluminium 
Insulation: XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655 or PVC (Polyvinyl Chloride) Type TI 1 to BS7655
Separator: PETP (Polyethylene Terephthalate) 
Sheath: PVC (Polyvinyl Chloride) Type 9 to BS7655
Sheath Color: Black 
Voltage Rating: 600/1000V 
Limited Use: Distribution of Signalling Power only 
Temperature Rating: +70˚C (BS6346) or +90˚C (BS5467) 
Core Identification: 2 Cores: Red, Black
  4 Cores: Red, Yellow, Blue, Black
  Or,
  2 Cores: Brown, Blue
  4 Cores: Blue, Brown, Black, Grey 

Bare Conductors For Overhead Lines

Bare Conductors For Overhead Lines

Bare conductors for overhead lines.

Welding Cables (Submersible Cables)

Welding Cables (Submersible Cables)

Application
For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.

Standards   
As per BS638 Part 4

Conductor
Class 6 extra flexible plain copper conductors to BS EN 60228:2005 (previously BS6360)(Class 5 flexible plain copper conductors for 120mm2 and above)

Insulation
EPR (Ethylene Propylene Rubber) to BS7655

Sheath
HOFR (Heat and Oil Resistant and Flame Retardant) Sheath to BS7655

Sheath Color
Black

Voltage Rating100V (450V for non-welding applications if suitably protected from mechanical damage)

Temperature Rating-20°C to +85°C

Pvc Sheathed Control Cables

Pvc Sheathed Control Cables

Rated temperature: 70oC
• Rated voltage: 450/750V
• Bare stranded copper conductor
• PVC or flame retardant PVC insulation
• PVC or flame retardant PVC jacket

Battery Cable

Battery Cable

Application for indoors and outdoors, in dry as well as wet location on motorized vehicles, or battery powered equipment such as fork lifts and field conveyors. Also in high quality booster cables.

Standards Figure 8 configurations based on VDE0250

Conductor Extra flexible class 6 copper conductors to BS6360

Insulation Red and Black TPE

Sheath Transparent PVC (Type TM2 to VDE0207)

Color Red and Black

Voltage Rating300/500V

Temperature Rating-25 to +70°C

Minimum Bending Radius6 x overall diameter

Automotive Cable

Automotive Cable

All automotive wire is made up of a number of strands of copper wire. Needless to say, the more current the wires are required to carry, the greater the number of strands it needs, so a cable designated 28/0.30 is made up of 28 strands of wire, each measuring 0.30mm in diameter. The following table shows the various sizes and the general use of the wire.

Payal Automotive cables are also manufactured as per the conventional sizes prevailing in the market where the copper and the PVC insulation meets the above standards requirements and impervious to water, oil, petrol, acid and greases.

Payal Automotive cables are supplied in standard lengths of 25 or 30 mts in carton boxes. However customer specified lengths can also be supplied.

Twin Flat Cables

Twin Flat Cables

Twin Flat Cables (With And Without Circuit Protective Conductor Insulated Or Bare)

Flat twin Cable with solid or stranded annealed copper conductor, PVC insulated and PVC sheathed.

Jumper Wire

Jumper Wire

Tinned copper conductor with a diameter of 0.6 mm PVC
(Polyvinylchloride) insulating cover. Also available in 0.5mm.

Double Pvc Insulated Single Core Surface Wiring Cable

Double Pvc Insulated Single Core Surface Wiring Cable

Application:
Fixed Installation in dry or damp areas for domestic and light industrial wiring. As per 6181Y.

Standards:
According to BS 6004.

Conductor:
Solid class 1: 1.0 - 2.5mm²
Stranded class 2: 4.0 - 25mm² to BS 6360

Insulation:
PVC or XLPE

Sheath:
PVC

Voltage Rating
300/500V

Temperature Rating:
0 to + 70°C

Telecommunication Cables

Telecommunication Cables

Annealed bare/tinned high conductivity copper, PVC/PE/Cellular PE insulated. Insulated
cores twisted to form a pair. Pairs laidup in sub-units/units in concentric layers. Taped.
Overall PVC sheathed. Individual and or overall shielding with Aluminium-Mylar tape/copper tape/lapping/braiding provided depending upon the requirement. Armouring provided with an extruded inner PVC/PE sheath and overall sheath of PVC/PE wherever required.

Aerial Bundled Cables

Aerial Bundled Cables

ABC-aerial bundled cables with aluminium conductor for 1 kV overhead system has been manufactured by Payal Cables.

Sizes and insulation in accordance with customer’s specifications will be manufactured by request.

The use of ABC cables in low voltage networks provides important saving in installation costs, while it ensures the same reliability and safety, replaces bare conductors in overhead distribution lines and increased very rapidly all around the world.

Speaker Cables

Speaker Cables

Two stranded bare copper conductors, PVC insulated (parallel webbed).

Low Capacitance Telephone (Data Cable )

Low Capacitance Telephone (Data Cable )

Temperature Range                          -20ºC to +80ºC
Specifications                                     As per UL - 444
Conductor                                           Solid Annealed Bare Copper Conductor.
Insulation                                           Polyethylene core insulation.
Assembly
Pairs twisted with staggered lay technique. Color coding is as per table 1. Twisted pairs are bundled into units of 25 pairs (subunits comprise 12/13 pairs) and cabled and covered with a polyester tape binder.
Outer sheath
Grey Colored flame retardant PVC.
Applications
Can be used as a service and installation cable in data transmission applications, computer, telephone etc.

Fire Performance Cable (Alarm Cable)

Fire Performance Cable (Alarm Cable)

Application:
For fixed installation typically in fire alarm and emergency lighting circuits where circuit integrity must be maintained. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.

Standards:
As per BS 7629-1BS 6387 C W ZBS 5839-1 clause 26.2BS EN 50200 PH30BS 8434-1

 

Conductor:
Insulation:
Screen:
Drain Wire:
Sheath:
Sheath Color:
Core Identification:
Voltage:
Temperature Rating:
Minimum Bending Radius:

Class 1 solid plain copper conductors
Special compound silicone and rubber mix
CAM (Collective Aluminium Mylar)
Tinner Copper
LSZH (Low Smoke Zero Halogen)
Red or White
2 Cores: Brown, Blue4 Cores: Blue, Brown, Black, Grey
300/500V
-30°C to +70°C
6 x overall diameter

Flame Retardant Heat Resistant Pvc Insulated Cables

Flame Retardant Heat Resistant Pvc Insulated Cables

 Reference Standards

 

 International:
 National:

BS 6004, BS 6500, DIN VDE 0281-3
IS 694, IEC 227

  Conductor

Bright annealed bare copper of high electrolytic grade drawn to fine strands, multi strands bunched together rope shaped wire for uniformity of conductor dia, resistance, dimensions and flexibility etc. The diameter of the conductor is so uniform that strands do not get cut when stripping the insulation thus conductor gives perfect conductivity which eliminates spot heating and sparking.

  Insulation

Specially formulated grade of PVC compound is capable of withstanding higher conductor temperatures with flame retardant properties. A rating of 105°C with FR properties enables the cable to withstand overloads without compromising safety. The insulation is resistant to boiling water, steam and vapors to prevent aging and cracking in practical usage in kitchens, bathrooms, damp walls, chemical industries etc.

  Marking

The Cable are printed with generic marking PAYAL - FRHR

  Packing

90 mts. length in attractive cartoons.