Electronic Equipment
Backed by the expertise of our professionals and our cutting edge technology, we manufacture and supply wide assortment of energy meter, lux meter, vif meter, power meter kwh, electronic equipment for power conservation. In addition to this we also offer technical help, consultation and audit to our clients. We use qualitative raw material such as panels, low voltage switchgear, electronic integrated circuit, capacitors and many more in the production process of our energy conservation equipment. Our wide gamut of electronic equipment comprises of the following:
|
  | Energy Meter We manufacture and supply optimum quality ‘energy
meter-logger’, an instrument which is capable of measuring and displaying
thirty six electrical parameters. Our energy meter also has the capability to
log and store 1000 sets of five important parameters in internal memory. We can
also customize the energy meter to increase the data logging facility for more
than 1000 records on client request. The recording interval which is normally of
one hour can be changed upon prior request of our clients. Any variation in
load by more than 20 per cent is also recorded. The meter is available with communication port and
appropriate software for accessing recorded data. CT/PT ratio is programmable.
Facility to calibrate voltage, current and power factor of individual phase is
provided through Keyboard and Display. The password for the energy meter is user-programmable.
Our energy meter is available in two different versions such as with LCD and
with seven segment LED display. Our technologically advanced energy meter
measures true RMS with data logging. Some of the salient features of our electric meter comprises
of the following:
- Measures
36 electrical parameter
- Records
five critical parameters at predetermined interval
- Facility
to upload data for system analysis and corrective actions
- Ideal
for captive power generation, supply of power to grid, and a host of
applications
- Recorded
data can be uploaded in PC or Laptop Computer through the communication
port RS 232 or RS 485
Send Business Enquiry | |  
  | Power Meter - KWH Our power meter KWH monitors and measures three phase active
energy with Built-in Rs485 communication with MODBUS-RTU Protocol. It has
programmable CT/PT ratio. The meter is offered with the facility to calibrate
Equivalent active power (KW). Our power meter measures true RMS and has
password user-programmable. Some of the technical specifications are as follows: Input:
- Input supply: 230 V AC - 10% 50 Hz.
- Three phase Voltage Input: 500 volts, Star
- CT / PT ratio: Programmable
Dimensional details:
- Cutout: 92 x 92 mm
- Bezel: 96 x 96 mm
- Depth: 130 mm behind bezel with CT inside
- Weight: 670 grams
- Mounting: Flush on Panel-DIN Standard
- Enclosure: IP 5x, ABS Molded Plastic
- Termination Details: L Type, 7 3 Pin detachable Phoenix
Environmental conditions:
- Operating Temperature: 0-550C
- Storage Temperature: -25 to 700C
- Relative Humidity: 0 to 95%, Non-condensing at 400C
-
Accuracy:
- Accuracy of Full Scale: - 0.5 %
- Parameters Measured and Displayed:
- Equivalent Voltage, Current, Active Power, Power Factor and
Active Energy
Display:
- Display LED: 4 digit, 7 segment, and 0.5”
- Parameter Refreshing Time: 500 ms
- Membrane Keys: Three
Communication:
- Communication/Protocol: RS 485 MODBUS-RTU
- Baud Rate: 9600 bps programmable
Send Business Enquiry |  
  | VIF Meter We manufacture and offer power meter VIF which is ideal for monitoring and measuring three phase Equivalent Voltage, Equivalent Current and Frequency with Built-in Rs485 communication with MODBUS-RTU Protocol. It is available with programmable CT/PT ratio. It also has the facility to calibrate Voltage and Current of individual phase is provided. Password for the power meter is user programmable. Some of the technical specifications of our power meters are as follows: Input: - Input Supply: 230 V AC 10% 50 Hz.
- Three phase Voltage Input: 500 volts, Star
- Three phase Current Input: 5 Amperes, (Maximum)
- CT / PT ratio: Programmable
Communication: - Communication/Protocol: RS 485 MODBUS-RTU
- Baud Rate: 9600 bps programmable
Dimensional details: - Cutout: 92 x 92 mm
- Bezel: 96 x 96 mm
- Depth: 130 mm behind bezel with CT inside
- Weight: 670 grams
- Mounting: Flush on Panel-DIN Standard
- Enclosure: IP 5x, ABS Molded Plastic
- Termination Details: L Type, 7 3 Pin detachable Phoenix
Display: - Display LED: 4 digit, 7 segment, and 0.5”x 3
- Parameter Refreshing Time: 500 ms
- Membrane Keys: Four
Parameters Measured and Displayed: Equivalent Voltage, Equivalent Current and Frequency Environmental conditions: - Operating Temperature: 0-550C
- Storage Temperature: -25 to 700C
- Relative Humidity: 0 to 95%, Non-condensing at 400C
Accuracy: - Accuracy of Full Scale: ±1%
Send Business Enquiry | |  
  | Lux Meter Our lux/light meter is designed and developed with the aim
to download the data on line. It is widely used for energy conservation where
lights are controlled by deciding the illumination level. Some of the
specifications of lux meter such as accuracy, measurement and others are given
in the tabulated form below. Specifications:
S. No.
|
Parameters
|
Device Specification
|
1
|
Unit of Measurement
|
LUX
|
2
|
Range
|
0 to 10,000 Lux std. , optionally 0 to 50,000 Lux
|
3
|
Accuracy
|
-5%
|
4
|
Working Temperature
|
0 to 55 deg C
|
5
|
Humidity
|
Up-to 90%
|
6
|
Communication Port
|
RS 485, 2 wire D , D- and ground
|
7
|
Device ID
|
Provided (std. factory set)
|
8
|
Data Sampling rate
|
Every 500 mili second ,
averaged for 10 seconds for display and 3 minute average for data download.
Optionally user may specify his requirement.
|
9
|
Protocol
|
MODBUS
|
10
|
Software for data logging
|
Supplied at extra price. Software can be customized as per user
requirement.
|
11
|
Power Input
|
220 V -10% , 50hz - 5% , battery 9V for backup
|
12
|
SIZE (Std)
|
110(height) X205 (Width) X 55(Depth) mm
|
Send Business Enquiry |  
  | Energy Conservation Solutions We, Power Energy Conservation offer our clients various
energy conservation related solutions such as Energy Monitoring System, Energy
Accounting System and Energy Management System.
- Our
energy monitoring system is ideal for monitoring the consumption online.
It is connected in the network wherein it collected the data at fixed
interval. The reports regarding power consumption is generated
periodically which is send to users through email.
- Energy
accounting system which we offer to clients is more effective than the
monitoring system. Our energy accounting system accounts the consumption
with respect to a process like energy consumption per unit production. It
is also ideal for monitoring efficiency and for verifying the process.
- Our
energy management system monitors energy meters, temperature, pressures
and lux meters as well as controls processes such as switching on lights
when lux level is at lower threshold and switch off on reaching upper
threshold. It also helps in cutoff air conditioning once target
temperature is reached.
Send Business Enquiry | |  
  | Timer Based Push Button Switch Our timer based push button switch is manufactured using
optimum quality raw material in the production process. Our range is widely
used to switch off lights / device after set time from switch- on. Our switches
are ideal for areas such as toilets, bathrooms or any area in industry or home
where people have tendency to forget to switch off. Specification
- Available
in the range of 500W, 230 V, 50 Hz & Single phase.
- Knob
for setting 0- 30 minutes delay for switching off the device/ light
Working Principle On pushing the button it switches on the device or lights.
There is facility so that users can set a time for switching off and also can
reset the time counting before the set time. Users can optionally choose a
manual off button for better control which is ideal for home geysers, toilets
and bathrooms. Send Business Enquiry |  
  | APFC Panel We manufacture and offer a wide range of APFC panels through
our sophisticated and cutting edge technology. Our range comprises of the
following types:
- Thyristor
switched APFC Capacitor Panel
- Contactor
switched APFC Capacitor Panel
- Manually
switched Capacitor panel
- Fixed
type capacitor panel
Some of the salient features of our APFC panels are as
follows:
- Custom
Built
- Capacitors
in multiple steps
- Rating
from 15 KVAR to 2000 KVAR
- Intelligent
/ Linerar Control strategy
- Indoor
/ Outdoor Installation
- Auto
and manual modes of control
- Special
design for harmonic conditions
Our APFC panels offer the following advantages for power
conservation such as:
- Improves
voltage regulation
- Reduces
units consumed in KVAH type billing
- Avoids
power factor surcharge / penalty
- Enables
in securing power factor incentive
- Reduces
current and hence losses in the circuit
- Brings
down Maximum Demands, lowers the fixed Charge and billing demand
Send Business Enquiry | |  
  | Digital Time Delay Switch We are also supplying digital time delay switch for various electronic purpose.
APPLICATION: 1- SWITCHES OFF AFTER SET TIME DELAY FROM START TIME.
2- ONE MAY SWITCH OFF IN BETWEEN ALSO. 3- IF RETRIGGER IS ENABLED, THE TIME SHALL BE COUNTED FROM LAST PRESS ON START BUTTON. 4- IN CYCLICAL MODE ONE MAY CHOOSE 16 SETS OF ON AND OFF TIME RANGES. IT MAY BE USED FOR ENERGY SAVINGS IN MANY APPLICATIONS.
Technical Specification
|
|
Model Number
|
TDS 02
|
Operating voltage
|
180V AC to 250V AC, 50HZ
|
Operating Power
|
0.798 W
|
Output
|
Single Channel Relay Output
|
Output Load
|
500 W Max.
|
Time Range
|
ON time selection in 16 Steps 4 to 64 Min. (Standard) OFF time selection in 16 Steps 4 to 64 Min. (Standard)
|
ON Time selection *
|
In system 8 - way DIP switch. (SW1 to SW4)
|
OFF Time selection *
|
In system 8 - way DIP switch. (SW5 to SW8)
|
Functionality selection*
|
in system 4- way DIP switch. 1. Retriggering mode 2. Stop Enable/disable. 3. cyclic timer mode.
|
Indication
|
Power ON LED indication (RED). System ON/OFF status (Green)
|
Control switches
|
1. START 2. STOP
|
Mechanical specification:
|
|
Mounting
|
Wall Mounting
|
Enclosure
|
PVC Housing
|
Dimension
|
69mm (l) X 62mm (b) X 60mm (h)
|
Operating Temperature
|
0 to +70 °C
|
Humidity
|
90% RH none Condensing
|
Send Business Enquiry |  
  | Street Light Control System Item Code: STC PEC custom designs the Street light controllers. We have following type of street light controllers. 1- Digital Clock based street light Control system: One may set the “On time” and “off time”. The switching of steet lights shall be repeated every day. Another option may be designed for switching ON/ OFF the alternate lights at designated time to save energy without compromising the requirements. 2- “Sun rise / Sun set” based Street light Control System : a. Uses digital clock based timer. b. Timer has memory to store the sun set and sun rise data for complete year. c. The timer has RS-485 communication port and uses MODBUS RTU protocol. The software with RS-485 to USB converter can be used for communication with timer. d. One may feed the data for complete year which may be repeated every year. e. At any point of time the data may be modified by the user. f. Optionally one may install the wireless communication device for communicating with the “ Street light control systems” g. Optionally Energy meter with RS-485 port may be installed and data for energy usage may be collected on line. One may think of any other usage of this system . we shall try to customize the same. 3- Light / Lux based control for switching the street lights: Light sensor is used for switching the lights. It is very important to a- place the light sensor in right direction. b- It should get the sun light directly without any hindrance. c- No auxiliary light should fall on it. d- Routine cleaning of sensor is must. 4- Street light control with Dimming for energy saving : The idea behind the control strategy is that during the late night till morning the traffic is low and hence it is possible to reduce the lux levels. The diming makes the lights uniform throughout the street and saves valuable energy. The saving may range from 20% to 35% depending on the control strategy and choice of lamps / fittings. We offer dimmable ballast based FTL (fluorescent tube) lights. The ballasts can dim the lights from 100% to 10% of power level. Dimming may be automated with digital timer based controls. Send Business Enquiry | |  
  | Consultancy & Audits We also offer consultancy and audits for various power
conservation problems. We offer consultancy for electrical system designs. Our
audit services are available for following range:
- Audit
for electrical system
- Audit
for Electrical Safety
- Audit
for energy usage
Our electrical system audit covers planning wherein we
identify the actual requirement keeping in consideration the future plans
against the adequacy of specification of equipment, cables etc. we recommend
electrical system audit as per Indian standard. As per our safety audit we cover the following:
- The
safety of electrical system equipment and cables etc. and reliability of
distribution system
- The
human safety during operation, maintenance and also general use
- Audit
of fire fighting system
According to our energy audit we offer the following
services:
- Audit of
System design for low losses
- Audit
of load balancing / cable loading
- Energy
bill audit, establishing the demand requirement and suggesting for
reducing the energy cost
We are capable of achieving our audit and consultancy
through following methodology:
- Discussion
with electrical department
- Physical
Inspection of site and its distribution system
- Verification
of design document with site layout or actual system
- Analysis
of data
- Submission
of final Report with Recommendation
- Discussion
To offer excellent audit to our clients we have experienced
professionals who take care of the whole process. Send Business Enquiry |  
  | CALANDER TIMER / TIME SWITCH APPLICATION: 1- Street Light Control 2- Building Automation 3- School bell ringing 4- Remote control of devices with the use of “ Master Application “ supplied on demand. 5- Factory light control for Saving energy Functioning: 1- Single Relay output 5 amps. 2- Relay can be programmed in a. Daily repeat mode: number of times on /off to be repeated every day b. Weekly repeat mode: number of times on/off on Monday, Tuesday, Wednesday, Thursday, Friday, Saturday & Sunday. Each day may be programmed differently. Finally the sequence shall be repeated from Monday to Sunday. c. Yearly repeat Mode: The whole year may be programmed for switching on/off. Max six set of on/off operation per day. The sequence shall be repeated every year. It takes care of leap year by repeating the 28 Feb events on 29 Feb. Through Software a person can control the devices in manual mode also. Communication: RS-485 2 wire System. Protocol: MODBUS RTU Software for monitoring and Control: One can attach number of calendar timers and control them individually through PC / Server. The control over internet may also be enabled. Data / status of timers can be obtained through software. The device id / mode / timing of operation can also be modified by the person with administrator login. This software is supplied at an extra cost. Address: we offer addresses free of cost on demand if someone wants to use it with their own software. Send Business Enquiry | |  
  | Dimmable Electronic Ballast Item Code: DEB01 Power consumption of ballast is negligible.
| Technical Specification
|
| 1
| Suitable for
| 1 no. 36 W , T-8 , FTL
| 2
| Power consumption at full load with 36 W tube
| 38 W at 230V , 50 Hz, 1 phase,
| 3
| Power Factor
| 99% at full load , above 95% above 25% load,
| 4
| Current harmonics THD
| Negligible , less than 1%
| 5
| Dimming Range
| 100% power to 10% power
| 6
| Power consumption with 36 W tube
| Reduces with dimming , dimming upto 10% of power level is possible
| Energy Saving upto 50% is possible. typically the payback is 6 to 12 months. Send Business Enquiry |  
|
 

|
 |