Products
Bearing Mounted Stationary Coil Clutch Electromagnetic clutch Dry operation Standard voltage is 24 v D.C. Other voltage 42 v, 90 v, 190 v available on request When electricity is not supplied , clutch remains disengaged . When electricity is supplied , clutch remains engaged Magnet coil is not rotating therefore slipring is not required Available torque 0.15 kg-m to 35 kg-m. Higher torque available on request Comparatively easy to installed because of bearing mounted design Single friction disc No residual torque in released condition Backlash free Compact design Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Direct Drive Clutch Electromagnetic clutch Dry operation Operating voltage is 24 v D.C or 110 v D.C. Other voltage available on request. When electricity is not supplied , clutch remains disengaged. When electricity is supplied , clutch remains engaged Magnet coil is rotating therefore slipring is used Available torque 1 kg-m to 1000 kg-m. Higher torque available on request Single friction disc No residual torque in released condition High heat dissipation capacity Worn out friction disc can be easily replaced Backlash free Simple maintenance We reserve our right to change specifications dimensions without prior notice
Your enquiry has been sent
Processing...
Double Clutch Two electromagnetic clutches in one housing Dry operation Standard voltage is 24 v D.C. Other voltage 42 v, 90 v, 190 v available on request When electricity is not supplied , that particular clutch remains disengaged. When electricity is supplied , that particular clutch remains engaged Magnet coil is not rotating therefore slipring is not required Available torque 0.5 kg-m to 10 kg-m. Higher torque available on request One friction disc for one clutch No residual torque in released condition Backlash free Compact design Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Electro Hydraulic Thrustor Load is moved by pressurized oil. Oil pressure is generated by induction motor placed inside oil tank Operating voltage is 415 v three phase 50 Hz Lifting capacity 8 kilogram to 185 kilogram Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Flame Proof Cover Specifications as per INDIAN STADARD IS and approved by CENTRAL MINING RESEARCH INSTITUTE OF INDIA , DHANBAD , ZARKHAND STATE. Used widely as FLAME PROOF ENCLOSURE for our other products e.g. SLDC brake , DAT series brake in fire explosion prone area. E.g coal mine, gas cracker unit , petroleum product refinery , gas fuel station Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Sakar External Mounting Brake Electromagnetic brake Dry operation Operating voltage is 24 v D.C . Other voltage available on request When electricity is not supplied, brake remains released. When electricity is supplied , brake remains applied Available torque 5 kg-m to 100 kg-m. Higher torque available on request Single friction disc Taper lock can be used for axial adjustment Backlash free Free from axial force Simple maintenance We reserve our right to change specifications dimensions without prior notice
Your enquiry has been sent
Processing...
Sakar Internal Mounting Brake Electromagnetic brake Dry operation Operating voltage is 24 v D.C . Other voltage available on request. When electricity is not supplied, brake remains released. When electricity is supplied , brake remains applied Available torque 5 kg-m to 100 kg-m. Higher torque available on request Single friction disc Taper lock can be used for axial adjustment Backlash free Free from axial force Simple maintenance We reserve our right to change specifications dimensions without prior notice
Your enquiry has been sent
Processing...
Sakar Series Stationary Coil Clutch Electromagnetic clutch Dry operation High heat dissipation capacity Taper lock is provided for axial easy axial adjustment Operating voltage is 24 v D.C. Other voltage available on request When electricity is not supplied, clutch remains disengaged. When electricity is supplied , clutch remains engaged Magnet coil is not rotating therefore slipring is not used Available torque 15 kg-m to 100 kg-m. Higher torque available on request Single friction disc No residual torque in released condition Backlash free Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Shoe Type Ac Brake Electromagnetic brake Operating voltage is 415 v two phase 50 Hz or 415 v three phase 50 Hz Failsafe type and released by electromagnetism Available torque 2 kg-m to 75 kg-m. Higher torque available on request Shoe type friction disc No residual torque in released condition Backlash free Free from axial force Simple maintenance We reserve our right to change specifications dimensions without prior notice. Dry Operation
Your enquiry has been sent
Processing...
Shoe Type Dc Brake Electromagnetic brake Dry operation Operating voltage is 24 v D.C or 110 v D.C. Other voltage available on request Failsafe type and released by electromagnetism Available torque 2 kg-m to 75 kg-m. Higher torque available on request Shoe type friction disc No residual torque in released condition Backlash free Free from axial force Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Stationary Coil Clutch Electromagnetic clutch Dry operation Standard voltage is 24 v D.C. Other voltage 42 v, 90 v, 190 v available on request When electricity is not supplied , clutch remains disengaged . When electricity is supplied , clutch remains engaged Magnet coil is not rotating therefore slipring is not required Available torque 0.15 kg-m to 35 kg-m. Higher torque available on request Single friction disc No residual torque in released condition Backlash free Compact design Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Vistar External Mounting Brake Electromagnetic brake Dry operation Operating voltage is 24 v D.C . Other voltage available on request. When electricity is not supplied, brake remains released. When electricity is supplied , brake remains applied Available torque 1 kg-m to 45 kg-m. Higher torque available on request Single friction disc High heat dissipation capacity Worn out friction disc can be easily replaced Backlash free Free from axial force Simple maintenance We reserve our right to change specifications dimensions without prior notice
Your enquiry has been sent
Processing...
Vistar Internal Mounting Brake Electromagnetic brake Dry operation Operating voltage is 24 v D.C . Other voltage available on request. When electricity is not supplied, brake remains released. When electricity is supplied , brake remains applied Available torque 3 kg-m to 1000 kg-m. Higher torque available on request Single friction disc High heat dissipation capacity Worn out friction disc can be easily replaced Backlash free Simple maintenance We reserve our right to change specifications dimensions without prior notice
Your enquiry has been sent
Processing...
Flange Mounting Motor Squirell cage induction motor. Operating voltage is 230 v single phase 50 Hz or 415 v three phase 50 Hz Continuous rating Totally enclosed fan cooled type Class of insulation E or F. Other class available on request. All dimensions are as per Indian Standard IS:2223 We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Foot Mounting Motor Squirell cage induction motor. Operating voltage is 230 v single phase 50 Hz or 415 v three phase 50 Hz Continuous rating Totally enclosed fan cooled type Class of insulation E or F. Other class available on request. All dimensions are as per Indian Standard IS:2223 We reserve our right to change specifications dimensions without prior notice
Your enquiry has been sent
Processing...
AC Brake Electromagnetic brake Dry Operation Operating voltage is 230 v single phase 50 Hz or 415 v two phase 50 Hz or 415 v three phase 50 Hz Failsafe type and released by electromagnetism Available torque 0.2 kg-m to 14 kg-m. Higher torque available on request Single friction disc e cept models having letter in theire name e.g DAT-150 has two friction discs and DAT-290 has three friction discs No residual torque in released condition Backlash free Free from a ial force Simple maintenance We reserve our right to change specifications / dimensions without prior notice.
Your enquiry has been sent
Processing...
Enclosed Type Clutch Brake Electromagnetic clutch brake combination Dry operation Operating voltage is 24 v D.C . Other voltage available on request Magnet coil is not rotating therefore slipring is not required Available torque 0.5 kg-m to 10 kg-m. Higher torque available on request Single friction disc Backlash free Compact design Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Flange Mounting Brakemotor Electromagnetic brake motor Motor is squirell cage induction motor. Brake power supply can be A.C or D.C There are many available combinations of brake. Kindly contact us for further details. Brake is Failsafe type and released by electromagnetism Backlash free All dimensions are as per Indian Standard IS:2223 We reserve our right to change specifications dimensions without prior notice
Your enquiry has been sent
Processing...
Foot Mounting Brakemotor Electromagnetic brake motor Motor is squirell cage induction motor. Brake power supply is A.C or D.C .There are many available combinations of brake motor. Kindly contact us for further details. Brake is Failsafe type and released by electromagnetism Backlash free All dimensions are as per Indian Standard IS:2223 We reserve our right to change specifications dimensions without prior notice
Your enquiry has been sent
Processing...
Open Type Clutch Brake Electromagnetic clutch brake combination Dry operation Operating voltage is 24 v D.C . Other voltage available on request Magnet coil is not rotating therefore slipring is not required Available torque 0.15 kg-m to 35 kg-m. Higher torque available on request Single friction disc Backlash free Compact design Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Vistar Series Open Type Clutch Brake Electromagnetic clutch brake combination Dry operation Operating voltage is 24 v D.C . Other voltage available on request. Magnet coil is rotating therefore slipring is used Available torque 1 kg-m to 45 kg-m. Higher torque available on request Single friction disc High heat dissipation capacity Worn out friction disc can be easily replaced Backlash free Free from axial force Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Dc Brake Electromagnetic brake Dry operation Standard voltage is 24 v D.C. Other voltage 42 v, 90 v, 190 v available on request. Failsafe type and released by electromagnetism Available torque 0.25 kg-m to 25 kg-m. Higher torque available on request Single friction disc No residual torque in released condition Backlash free Free from axial force Simple maintenance We reserve our right to change specifications dimensions without prior notice
Your enquiry has been sent
Processing...
Slip Ring Clutch Electromagnetic clutch Dry operation High heat dissipation capacity Taper lock is provided for easy axial adjustment Operating voltage is 24 v D.C. Other voltage available on request When electricity is not supplied , clutch remains disengaged . When electricity is supplied , clutch remains engaged Magnet coil is rotating therefore slipring is used Available torque 5 kg-m to 100 kg-m. Higher torque available on request Single friction disc No residual torque in released condition Backlash free Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...
Shoe Type Electro Hydraulic Thrustor Brake Brake is operated by pressurized oil Oil pressure is generated by induction motor placed inside oil tank Operating voltage is 415 v three phase 50 Hz Failsafe type Available torque 4 kg-m to 125 kg-m. Higher torque available on request Shoe type friction disc No residual torque in released condition Backlash free Free from axial force Simple maintenance We reserve our right to change specifications dimensions without prior notice.
Your enquiry has been sent
Processing...