Testing Equipments And Services
|
Highly durable and reliable, our products are manufactured under complete supervision of expert technocrats and engineers. Developed with specification to details provided by clients, our product range includes:
|
| | High Voltage Power Source (Item Code : H-12-100) The
instrument is used to get the high voltage 0 to 12 KV/100mA as output
from the 230VAC input. This is provided with built-in SF6 gas filled standard capacitor and useful for both grounded as well as ungrounded
objects. Higher KV and current capacity power supply can be provided
as per the requirements of our clients. Features: (A)
Switch for three different types measurement: 1) UST - Ungrounded Specimen test - 3 combinations. This
mode is used when the object under test is not grounded. This test
provides most accurate results. 2) GST - Grounded Specimen test This
mode is used when the object under test is permanently grounded.
This test is used more often in outdoor installations & power
systems 3) GSTG - Grounded specimen test with guard. 3 combinations. This
mode is used for measuring the stray capacitances and separating
it from basic measurement in GST mode. (B) Indication:Two 3½ digit digital panel meters one for voltage indication
with 19.99 KV full scale and other for current indication. Safety
Features:
- Zero
start control
- Open Ground Indication Lamp with Double Grounded Connection
- External
Interlock
- HT
Cut-off/on Overload
- HT
On & Supply On Indication
- All Operating Controls at Earth Potential.
- Necessary Terminals & Sockets for connection to TD-1
Application
Areas:
- H.T.
& L.T. Power Capacitors
- Testing
of H.T Transformers
- Power
Systems
- Power
Cables
- High
Voltage
- Laboratories
- Generators
- Bushings
- Motors
Technical
Applications: Power
Required: 230 VAC ± 10%, 50 Hz Standard Capacitor: Standard
Capacitor is compressed SF6 gas filled type and is built into
HV Power Source. Capacitance: 100 pF ± 5%, actual value is indicated on capacitor. Tan: Less than 0.00001 Rated
Power: 1 KVA Max, 100mA Long Term Test
Voltage:
0 to 12 KV / 50 Hz | | Send Query |
| | Capacitance & Tan-Delta Testing Equipment (Item Code : TD-1) Electrical
properties of insulating systems change due to age and Continuous
electrical stress. By measuring electrical properties such as
Capacitance and Tan d regularly it is possible to ensure the
operational reliability of H.V. insulating systems and to avoid
costly 2 Capacitance & Tan-Delta Test System [Model :- TD-1 ]
breakdowns. PE Capacitance and Tan d test set comprises of C and Tan
d Test System Model TD-1, High Voltage Power Source Model H-12/100
with built in standard capacitor, and set of cables. The compact
design of the Bridge uses the principle of three winding differential
transformer on a high permeability u metal core. The Bridge is
contained in a sturdy metallic housing with u metal lining which
shields it from external electromagnetic & electrostatic
influences. Features:
- High
Sensitivity
- User
Friendly
- Accuracy
Application
Areas:
- High
Voltage Sub-Stations
- Operation
in Workshop
- Switch
Yards
- Factories
Interface
Suppression: C
& Tan d Test System has been specially protected with u metal
sheets to keep away from the effect of external interferences. This
makes the dimension exact in both inside as well as outside
applications particularly in Switch yards. Phase reversal switch
provided in the H.V. Power Supply effectively cancels
interference/pick up by the object under trial in energized
environment. For situation where the generation is extreme, and
cannot be cancelled by phase reversal switch a separate three level. Interface
suppression unit can also be given with separate C & Tan
d adjustments. Protection: The
bridge is provided with built in high voltage protection which
protects the bridge & operator against failure of test object or
standard capacitor. Technical
Specifications: Capacitance
Range:
1 pF to 0.1uF in three ranges with Cs=100pF Accuracy: 0.1 Factor: - ± 1 % of reading ± 1 to 2 x 10-4 1
Factor: - ± 1 % of reading ± 1 to 2 x 10-3 10
Factor: - ± 1 % of reading ± 1 to 2 x 10-2 Tan
d Range:
0.0001 to 11.1 in three ranges Accuracy: ± 0.2% Power
Supply: Dry Batteries, 9 V x 2 nos. Weight: LESS THAN 20 Kg. | | Send Query |
| | Oil Dissipation Factor Meter (Item Code : ODF-1) This set is designed for Tan Delta measurement of Insulating Oil by using
three terminal test cell with heating chamber. It gives Dielectric
constant and Tan Delta (in percentage) directly on digital meter. The
pressure voltage at which the measurements are to be made can be made
and set as desired. Power basis is continuously variable up to 600
VAC which gives a highest stress voltage of 300V/mm in POWER Three
terminal test cell. Features:
- Direct
readout of Dissipation Factor [Tan-Delta] in percentage.
- Sufficient
Power Supply
- No
tuning is necessary prior to every single reading.
- Results
in higher testing speed and even semiskilled operators can use the
equipment easily.
Technical
Specifications: Tan
Delta Range: 0 to 19.99% FSD with resolution of 0.01% TanD. Dielectric
Constant Range:
0.2 to 10 Test
Voltage:
0-600 VAC continuously variable or as ordered (Stress
voltage 300 V/mm) Indication: 3½
digit panel meter for tan d & 3½" taut band analogue
panel meter
for voltage and Null indication Power
Supply: 230 VAC ± 10%, 50 Hz (110V, 60 Hz on request) Warm
Up Time: 5 minutes Dimensions: 420 x 270 x 220 mm Weight: 7 Kg (approx.) | | Send Query |
| | Insulation Resistance Tester (For Oil Resistivity) (Item Code : IRT-500) These
sets have facility for checking insulation resistance in the range of
1 meg ohm to 10 million meg ohm after one minute of charging.
Intrinsic value of insulation resistance if required, even with
capacitive loads. Separate push button controls and visual indicators
for "Charge", and "Discharge" function are
ideally suited for rapid and safe testing of components in a factory. Maximum output current has been limited to safe value to eliminate
the risk of
serious shock to operators. The instruments are available in two models
as per specifications given overleaf. Features:
- Completely
solid state circuitry, hence drift free operation
- Fully
protected against all overload and short circuits
- Suitable
for testing ' EARTHED' Samples
- Tests
as per I. S. I. recommendations
- Push
Button Controls for rapid testing
- Suitable
for testing insulation liquids
- Wide
measurements range
- Guard
Terminal provided
Technical
Specifications: Overload
Protection: Fully
protected against wrong selection of breakdown of components under
test. Power
Supply: 230V
AC ± 15%, 50 Hz Single Phase Resistance
Range: 1
Meg to 10 Meg in 6 ranges Indication: 4¼
Taut Band Panel Meter D.C Voltages:
For Model IRT-500 :- 63V,
100V & 500V ± 2% For Model
IRT-1000:- 100V,
250V, 500V & 1KV ± 2% Warm
up time: One
minute Weight: Less
than 7 Kg Application
Areas:
- Ceramic
Capacitors
- Semi
Conductors
- Plastic
Capacitors
- Paper
Capacitors
- Transformers
- Connectors
- Insulators
- Switches
- Motors
| | Send Query |
| | Heating Chamber Heating
Chamber, (OHC) with Three Terminal Oil Cell, is designed to heat the insulating oil up to the elevated
temperature 0-150 º C in short time of 15-20 minutes. A
potentiometer is provided for setting of temperature at required
level. Heating chamber with oil cell for easier testing at required
temperature fitted with thermostat & protection device to prevent
shock hazards. Three Terminal oil cell is designed to test the
Dissipation Factor (Tan-Delta) & Resistivity of the insulating
oil. Technical
Specification of Oil Heating Chamber [OHC]: Temperature
Range: 0-150 º C Indication: 31/2 Digital Panel Meter Heating
Element: Heating Coil Power
Source: 230VAC / 50Hz Sensing
probe: PT100
Technical
Specifications of Three Terminal Oil Cell:
Made
up of: S.S. & Teflon Spacers Cell
Capacitance: 55 Pico-Farad / ± 1 pf Volume
(Oil): 45-50ml. Cell
Constant: 620 Nominal Electrode
Distance: 2 mm
| | Send Query |
| | Compressed Gas Standard Capacitor Compressed
Gas Standard Capacitor is a set capacitor used as Capacitance
standard in Bridge circuit for precision measurement of Capacitance
and Tan d of high voltage test objects.
The
electrodes are made of polished metal and enclosed in a suitable
cover for protection against dust and moisture. The compressed gas
capacitor is filled with Sulphur Hexafluoride (SF6) under moderate
pressure. Features:
- Negligible
dissipiation factor
Technical
Specifications: Accuracy
of Capacitance: 0.1% Operating
Frequency: 50Hz 10% Operating
Voltage: Up to 12 KV rms MODEL: Cs - 100 Capacitance: 100pf±5% Tan
d: <1 x 10 - 5 Temperature Co-efficient: <100 ppm Dielectric: SF6 Max.
Height: 370 mm Max
Diameter: 170 mm | | Send Query |
| | HV Capacitance & Tan-Delta Calibrator Decade This
decade is specially designed for cross-checking the HV Capacitance
& Tan-Delta Test System [Model TD-1] at 5KV. This decade
having one capacitance tap along with three different Tan-Delta
ranges.
| | Send Query |
| | RLA/Power Transformer Tester Capacitance & Tan-Delta Measurement:
A dielectric loss testing program provides several important benefits. Periodic tests performed during the service life of the equipment can indicate that the insulation is either aging normally or deteriorating rapidly. Diagnostic tests may disclose the location of a fault, or the reason for failure. Insulation Resistance and Polarization Index is the most widely practiced and accepted test in identifying dryness/wetness of paper insulation. The life of transformer is mainly based or is very sensitive to amount of moisture content in paper insulation. This test gives information on aging condition or status of the insulation, moisture content in paper and hence is a very important test for identifying residual life.
Dielectric Loss Measurement (DLM) is in an insulation system is the power dissipated by the insulation when subjected to an applied alternating voltage. A high loss may indicate problems in the insulation structure. Normal aging of an insulating material will cause dielectric loss to increase. Contamination of insulation by moisture or chemical substances may cause losses to be higher than normal. Physical damage from electrical stress or other outside forces also affects the level of losses.
Winding Resistance Measurements:
The test is most effective when compared with such measurements from similar transformers, or previous test results or factory test data. This gives vital information for identifying abnormalities like loose connections and even broken strands. Since it is done at various tap positions, it also identifies any issues with OLTC such as high resistance joints. When compared with readings taken from each phase to ground
Turns Ratio/Voltage Ratio:
When the transformer is on open circuit, which is usually the case during field service, voltage ratio and turns ratio is considered equal for all practical purposes. The turn’s ratio test which is determined for all the taps with the tap changer for deenergized operation at one specific location such as nominal position helps in identifying part of the winding that is faulty, such as due to inter-turn shorts. This also helps in identifying problems that can otherwise lead to reduced secondary output, increased losses or voltage regulation issues.
| | Send Query |
| | RLA/Testing of HT Motor/Generator Vibration & Phase Current Signature Analysis can be used to find out
following defects:
- Motor
Rotor eccentricity Motor Rotor Bar Cracks
- Misalignment
or Bend Shaft
- Motor
Rotor Bar looseness
- Foundation
defect / soft foot
- Electrical
defect in motor
- Mechanical
looseness
- Defective
belt drives
- Unbalance
in a Rotor
- Damaged
Bearings
- Gear
defects
- Resonance
Winding Resistance Measurements: The
test is most effective when compared with such measurements 10
RLA/Testing of H. T. Motor/Generator from similar motor/generator, or
previous test results or factory test data. It
gives the full information of abnormalities like loose connections,
broken strands etc. It even identify other issues like unbalance that
result in overheating & circulating events. Insulation Resistance Polarization Index [IR/PI]: Insulation
Resistance and Polarization Index is the most commonly Practiced and
accepted test in identifying dryness/wetness of paper insulation. The
life of motor/generator is mainly based or is very sensitive to
amount of moisture content in paper insulation. This test gives
information on aging condition or status of the insulation, moisture
content in paper and hence is a very important test for identifying
residual life. Dielectric Loss Measurement (Capacitance & Tan-Delta): A
high loss may indicate problems in the insulation structure. Normal
aging of an insulating material will cause dielectric loss to
increase. Contamination of insulation by moisture or chemical
substances may cause losses to be higher than normal. Physical damage
from electrical stress or other outside forces also affects the level
of losses. A dielectric loss testing program provides several
important benefits. Periodic tests performed during the service life
of the equipment can indicate that the insulation is either aging
normally or deteriorating rapidly. Diagnostic tests may disclose the
location of
a fault, or the reason for failure. | | Send Query |
| | 'X' Mer oil Testing (NABL Accredited Lab) We at Power Electronical are also engaged in manufacturing, maintenance & calibration services of insulation testing instruments. As well, by an experience we have entered in Transformer Oil Testing Services as per requirement of NABL - ISO / IEC-17025: 2005[E] & RLA of the Power Transformer.The Physical & Chemical test are carried out as per IS 1866:2000 and Dissolved Gas Analysis as per IS 9434:1992. For the sampling of oil from transformers mostly air tight Metal cylinders (Stainless Steel) can be used effectively. To obtain a representative sample, it is necessary to use the proper sampling technique. (IS 6855:2003). Application Areas:
| | Send Query |
| | On Site"Tan-Delta" Testing of EHV Objects Dissipation
Factor (Tan-Delta) is one of the most influential off-line
nondestructive diagnostic tool to check the state of solid insulation
of various high voltage equipment. Capacitance and Tan-Delta values
obtained on new insulation are treated as standard readings. Then by
measuring and comparing the periodical readings of the Capacitance
and Tan-Delta of the insulating material with the benchmark readings,
one can know the rate of deterioration of health of the insulation. By
calculation of the rate of deteoration we can:
- Repair
the insulation before actual flashover, saving high cost of
replacement of material which will reduce the inventory as well as
delay in procurement at the last minute.
- After
repair, quality of insulation can be checked before returning the
equipment to service.
- Predict
the future unexpected breakdown of the insulation of HV equipment.
- Plan
the maintenance schedule.
When
to check Capacitance & Tan-Delta:
- Frequency
of testing depends on environmental conditions. More humidity,
temperature, pollution would require frequent measurement of
Tan-Delta.
- In
service & will be depend on rate of change of Tan-Delta Vs
Voltage Vs Time (Month/ Year)
- Frequency
of testing depends on history of past failures on same machine.
- During
manufacturing process preferably at each stage.
| | Send Query |
| | Calibration of Measuring Instrument(Electro-Technical Field) We Provide Calibration services for Electro-Technical Field Instruments :
- Digital /Analouge Multimeter
- Digital / Analouge Earth Tester
- Digital / Analouge Insulation Resistance Tester
- High Voltage Tester
- Clamp on Meter
- High Voltage Probe
- Capacitance & Tan Delta
- Brake Down voltage Tester
- Temperature (0 to 150 Degree)