IndiaMART.com
Company Directory  > Plant & Machinery  > Instrumentation & Control Equipments  >
Share:

Power Machines India Limited

Noida, Uttar Pradesh

Year of Establishment: 2000
IndiaMART Member Since: 2008
Products [20]
Phone: +(91)-(120)-4036001

HOME

ABOUT US

PRODUCTS & SERVICES

CONTACT US

SEND ENQUIRY


Turbines



Francis Turbines

Francis Turbines
Francis turbines, output range to 720 MW, head range 18 to 700 m.

 
 

Kaplan Turbines

Kaplan Turbines
Kaplan turbines, output range to 300 MW, head  range 5 to 70 m.

 
 

Condensing Steam Turbine

Features:

  • Single-cylinder condensing steam turbine with three points of non-variable  steam extractions for regeneration.
  • Provision is made for an additional non-variable  steam extraction for station services.
  • The turbine is delivered skid-mounted and no dismantling is needed during erection. Turbine length is 7.6 m., required minimum height of the traveling crane main hook with reference to the turbine service floor is 7.5 m.
  • Electronic part of the turbine control and protection system is adapted to operate with  modern I&C System of the power unit.
  • It is possible to modify the turbine meeting  requirements of a  particular Customer.

 
 

Driving Turbines (0.235 - 17.5 MW)

Operate at a variable speed with a wide range of loads under variable inlet and outlet steam conditions. Condensing and back-pressure driving turbine are designed for direct drive of power unites pumps at Water Stations and Nuclear power plants with capacity range of 300, 500, 800 and 1000 MW and to drive compressor, and also for pumps installed at ammonia process lines; and for marine use as well.

 
 

Geothermal Steam Turbines

Geothermal steam turbines with output range 17.5 MW and 25 MW allow to use the steam and water of geothermal fields or to utilize the waste heat of industrial plants.

Technical Specifications:

Parameters К-17-5-Гео К-23-7-Гео
Rated output, kW 17500 23000
Rated rotor speed, rpm 3600 3600
Main steam conditions rated value:       
  • rated absolute steam pressure,  MPa
  • 0,56 0,7
  • dryness fraction
  • 0,995 0,995
    Absolute steam pressure downsteam turbine, kPa 8,9 11,2
    Steam flow rate, t/h 140 170
    Condenser type

    Water-cooled mixing

    Cooling water temperature,oC 33,5 (15-47) 33,5 (15-47)
  • nominal value (range)
  •    
    Oil system    
  • oil tank capacity, m3
  • 3,6 3,6
  • cooling surface of oil cooler, m2
  • 24 24
    Overall dimensions, m    
  • turbine weight, t
  • 29 29
  • turbo-generator weight, t
  • 113 120
  • condenser mass, t
  • 470 90
  • turbine foundation height, m
  • 1,4 4,7
  • height of crane hook above the machine-room floor, m
  • 7,6 13,5


     
     

    Thermal Clamping Turbines

    Features:

    • Single-cylinder turbines with controlled steam extraction for district heating or for industrial purpose.
    • Extracted steam pressure is controlled with rotary diaphragm installed in the extraction chamber.
    • Version T-25-3,4 features with two uncontrolled steam extractions for industrial purpose. Air-cooled condenser is used, but no regenerative feed water heating.
    • The turbine can be modified in design and regenerative system arrangement for needs of the particular Customer.
    • Provision is made for installing the turbines of this type on existing foundations of similar class turbines, in case of their replacement due to expired service life, making the most use of the existing building constructions.

    Technical Specifications:


    Parameters of the turbine Т-30-2,9 Т-25-3,4 П-30-2,9
    Rated/maximum output, MW 30/31 23/30 30/30,5
    Initial steam conditions:         
  • pressure, MPa
  • 2,9 3,4 2,9
  • temperature, 0C
  • 410 435 435
    Live steam rated flow, t/h 220 160 260
    Maximum heat-producing capacity of extraction for district heating, GJ/h 290 360  -
    Control range of pressure in extraction line for district heating, MPa 0,07-0,12 0,07-0,25  -
    Maximum flow rate of steam extracted for industrial purposes, t/h
  • upstream extraction
  • 60 25 150
  • downstream extraction
  • 60 50 150
    Maximum pressure in extraction line for industrial purposes, MPa: 
  • upstream extraction
  • 0,7 1,46 1,3
  • downstream extraction
  • 0,7 0,48 1,3
    Length of airfoil of last stage moving blade, mm 540 370 540


     
     

     

    Related Product Catalogs

    Sai System & Control
    Exporting, supplying and manufacturing of revolution per minute indicators such as voltage indicators, programmable indicators, led digital indicators, display indicators, power indicators and digital indicators.

    View more details

    Protocontrol Instruments India Pvt. Ltd.
    Engaged in supplying and manufacturing of control equipment such as calibration equipment, digital temperature controller, electric timer and temperature transmitters.

    View more details

    Prayosha Biomedical & Health Care
    Supplier and trader of control equipment, climate control system, climate control system s9, sleep therapy system, slimline tube, temperature control system and climate control equipment.

    View more details

    Suggested Companies


    Related Categories
    Search Suppliers
    CompanyProductsTrade Leads
    OR


    IndiaMARTCompaniesProductsTrade LeadsTendersTrade ShowsTravel
    © 1996-2012 IndiaMART InterMESH Limited. All rights reserved worldwide.