We offer different Electrical Panels..
|
 |
We are offering Annuciator. Our Alarm Annunciator is as per following specification :
Annuciator Model Features
| Sl. |
PSS 400 |
PSS 500> |
PSS 401 |
PSS 350 |
|
PSS 351 |
PSS 352 |
PSS 353 |
PSS 400 |
| 1. |
System Content |
ANN |
ANN |
ANN |
ANN |
ANN |
ANN |
ANN |
ANN |
| 2. |
Overall dim |
96 X 96 X 150 |
260 X 145 |
220 X 170 |
220 X 170 |
220 X 170 |
170 X 220 |
170 X 220 |
285 x 140 |
| 3. |
Cutout |
92 X 92mm |
230 X 145 |
205 X 155 |
205 X 155 |
205 X 155 |
155 X 205 |
155 X 205 |
285 X 140 |
| 4. |
Window Size |
30 X 40mm |
25 X 60 |
45 X45 |
45 X45 |
45 X45 |
45 X45 |
45 X45 |
45 X45 |
| 5. |
No. of Windows |
14W |
6 -8 W |
9 - 10W |
1 - 8W |
1 -12W |
1 - 12V |
1 -8WV |
1 - 20W |
|
 |
Product Description
The series current transformer CT can be applied to test, control, display and record the running of the equipment against the damage in the AC circuit with the running of the electrical equipment, and to protect the equipment against the damage in the AC circuit with the rated voltage below 600V and the frequency of 50/60Hz. The products can be also applied to from a complete set of mine transformer. |
 |
Our Current Converter Unit are as per following specifications:
Annex.A :Features of Various Model of RTT - 3000
| Sl. |
Features |
CCUPT 203 |
CCUO 201 |
CCUT 202 |
| 1. |
Application |
Measurement of Winding Temperature |
Measurement of Top Oil Temerature |
Incication of operating Tap no. of transformer fitted with OLTD |
| 2. |
System Contents |
Sensor with PT- 100 insert & heater Shunt resistor unit Current Converter Unit (CCU) |
Sensor with PT -100 insert Current Converter Unit (CCU) |
Current Converter Unit (CCU) |
| 3. |
Mounting |
Rail Mounting |
Rail Mounting |
Rail Mounting |
| 4. |
Temperature Range |
0 - 150 deg. c However temp. range can be set up to -50 deg to 400 deg. C if required |
0 - 150 deg. c However temp. range can be set up to -50 deg to 400 deg. C if required |
N.A |
| 5. |
Auxiliary Supply |
90 - 260 V ac/dc |
90 - 260 V ac/dc |
90 - 260 V ac/dc |
| 6. |
Output |
Two outputs 4 - 20 mA at 500 mA at 500 Ohm burden each |
Two outputs 4 - 20 mA at 500 mA at 500 Ohm burden each |
Two outputs 4 - 20 mA at 500 mA at 500 Ohm burden each |
|
 |
Our Electronic Hooter are as per following specification.
Features
High Audio Output : 90 to 125 dB
Single supply : 12V AC/DC, 24V AC/DC, 48V AC/DC,
110 VAC, 230 VAC
or Univeral Supply : 24 - 240 V AC/DC
Din standard (96 X 96 X 65 mm) Panel / Wall mounting.
Cut-out 92 (W) X 92 (H) mm
Tone & Volume Adjustable
Custom Models with multiple tones / Musical tones |
Automatic Power Factor Control
|
 |
Our Automatic Power Factor Control are as per following specification :
PF Target Power Factor (1.70 to 1.00)
PF Cap / Ind : Lagging /Leading Target Power Factor.
Dead band : Dead band for target Power Factor (0.00 t0 0.30). Corr. Delay : Capacitor - switching delay (1 to 250).
Ct Rating 1A / 5A : Current rating for the current transformer/ (select 1 AMP if the CT input is received through the select 5Amp if the CT input is received through the R5 pin of the power connector).
Ct Ratio : turns ratio for the current transformer (1 to 200)
Program No : Program No. ( 1 to 33) (refer the program no. chart).
CB1 KVAr : KVAr rating of the first Capacitor Bank connected (0.5 to 99.5 KVAr)
Change password : Change password (0000 to 9999)
Enter Password : Enter Password (0000 to 9999)
Wrong Password : Incorrect Password.
ONLINE MODE MESSAGES :
OverVtg : Over Volatage.
UnderVtg : Under Voltage
UnderCurr : Under Current
OvercComp : Over Compensation
UnderComp : Under Compensation
Ct. conn : Incorrect CT Connetion |
|

What We Offer Electrical Panels Alarm Annunciator Current Transformer (CT) Current Converter Unit Electronic Hooter Automatic Power Factor Control Voltage Regulators Digital Indicators
|