The amalgamation of sound infrastructure and technical knowledge brings forth the wide range of high precision plano productslike industrial optical instruments, polished optical prisms, optical instruments, flat optical prisms. Our products are widely appreciated in domestic, as well as, in overseas marketplace. The wide spectrum of superior quality products is:
|
 |
Optical Prisms |
|
 |
|
|
 |
We are offering high quality optical prisms. Optical prisms are the blocks of optical material with flat and polished sides that are arranged in a precisely controlled angles to one another.
Technical Specification
| Prisms |
|
Standard |
Precision |
| |
Material |
BK-7/Fused Silica |
| Right Angle Prisms |
Dimensional Tolerance |
0.15 mm |
0.02 mm |
| Penta Prisms |
Surface Quality (Scratch & Dig) |
80-50 |
20-10 |
| Equilateral Prisms |
Surface Flatness@632.8nm |
l/2 |
l/10 |
| Dove
Prisms |
Angle Tolerance |
3 Min |
<5 secs |
| Amici Roof Prisms |
Bevel |
0.2 mm x 45° |
| Anamorphic Prisms |
Size Range |
5 mm --- 100 mm |
| Corner Cube Prisms |
Coatings |
Al+SiO/ SLARMgF2 |
| |
|
 |
 |  | |
 |
Optical Flats |
|
 |
|
|
 |
Optical flats are polished flat surfaced device used as references against which the flatness of an unknown surface may be compared.
Technical Specifications
| Material | BK-7/Fused Silica | | Surface Quality | 80-50 | | Surface Accuracy | l/4,l/6,l/10@632.8nm | | Second surface | l/2@632.8nm | | Angle Tolerance | <5 minutes | | Bevel | 0.3mm x 45° |
| Part No (Prefix A for Fused Silica) | Diameter (mm) | Thickness (mm) | | OF-25 | 25 | 10 | | OF-30 | 30 | 12 | | OF-50 | 50 | 15 | | OF-75 | 75 | 20 | | OF-100 | 100 | 25 | | OF-125 | 125 | 30 | | OF-150 | 150 | 35 |
- Accompanied by Flatness Inspection Report
- Cosmetic Defects: According to US MIL Std
- Supplied in Wooden Box
- Inspection carried out in Laser Fizeau Interferometer with 100 mm diameter Reference Flat (/20) traceable to NIST
- Evaluation of flatness conducted with Licenced Quick Fringe Software
Applications:
Inspection of flatness of Mechanical Seals, Pump Valves, Lapped Components
| |
|
 |
 |  | |
 |
Optical Parallels |
|
 |
|
|
 |
We offer high quality optical parallel for use in large capacity switches, routers and data transport equipment.
Technical Specifications
| Material | BK-7/Fused Silica(SuffixA) | | Dimensional Tolerance | ¡Ó0.15 mm | | Thickness Tolerance | ¡Ó0.01 mm | | Surface Quality | 80-50 | | Surface Accuracy | 0.2 microns | | Parallelism | 0.1 microns | | Bevel | 0.5mmx45¢X |
| Part No | BK-7/Fused Silica(SuffixA) | Thickness (mm) | | OP-01/ OP-01A | 30 mm | 12.000, 12.127, 12.250, 12.375 | | OP-02/ OP-02A | 50 mm | 25.000, 25.127, 25.250, 25.375 |
- Accompanied by Flatness Inspection Report
- Cosmetic Defects: According to US MIL Std
- Supplied in Wooden Box
- Inspection carried out in Laser Fizeau Interferometer with 100 mm diameter Reference Flat (Ü/20) traceable to NIST
- Evaluation of flatness conducted with Licenced Quick Fringe Software
- Parallelism Inspection by Haidenger Fringe method using special Software
Application
Inspection & Calibration of Flatness of Micrometer anvils.
| |
|
 |
 |  | |
 |
Laser Interferometer |
|
 |
|
|
 |
Avail from us, superior quality laser Inferometers for linear measurements.
Features
- Small size and low weight
- Easy beam alignment
- Easily transportable
- Simple operation
- High resolution
- High precision
- Low price
Applications
- Positioning of CNC and CMM
- Machine geometry Inspection
- Flatness Measurement
- Angular Positioning
- Ball Screw Inspection
- Servicing Application
Technical Specifications
| Measurement | Range | Resolution | Accuracy | | Distance | 0-30 m | 0,01 µ m(0,001 µm)* | 1,5 µm/m | | Velocity | 0-0,3 m/s (0,1 m/s) | 0.25 µ m/s | 0,1% | | Angular | 0-3600 arc sec | 0,04 arc sec | ±0,2% | | Straightness Measurement (with angular optics) | 0-12 m | 0.02 µm (for 100 mm base) | ± 1% | | Flatness *** | 0-12 m (± 3 mm) ± mm flatness measurement range) | 0,02 µm ( for 100 mm base) | ±1% | | Straightness measurement (with wollaston prism ) | 0-3 m | 0.01 m | ± 1% | | Squareness | ± 1000 arc sec | 0,03 arc sec | ±1% ± (1,5 arc sec) | | Rotary measurements | ±5° | 0,04 arc sec | ±0.2 % |
The maximum velocity for 0.001 µm resolution is 0.1 m/s, the 0-15 m range request, moody method and grid method.
| |
|
 |
 |  | |
 |
Fizeau Interferometer |
|
 |
|
|
 |
Flatness measurement interferometer set-ups such as this, are used for the metrology of surface flatness of plano elements such as mirrors, prisms, windows & lapped mechanical components. This is a non-contact measurement, unlike using Optical Flats by contact method, wherein the reference Optical Flat is damaged after constant usage.
The transmission/ reference flat serves as a reference which is compared with the test component.
The basic Interferometer has two operating modes Alignment Mode & View mode. In the Alignment mode, the integral tilt-table is adjusted to superimpose the images on the video monitor. View mode yields high contrast fringes.
From the fringe pattern, the flatness of the test component is evaluated.
Technical Specifications
| Orientation | Vertical | | Light Source | He-Ne Laser at 632.8nm - Imported | | Reference Flat Accuracy | l/10 with NIST Traceability | | Work Table (Tilt Table) Dimension | 8" x 8" | | Warm-up time | < 10 minutes | | Power | 220V,50Hz | | Weight | Approx 40 Kgs |
- Colour / Mon Video Monitor
- CCD Camera
- Selection Mode for rapid Alignment and Fringe viewing
| Model | Vertical Model | | LFI-100/V | 100 mm Vertical Model | | LFI-50/V | 50 mm Vertical Model |
Optional Accessories
Static Quick Fringe Analysis Software & Frame Grabber.
| |
|
 |
 |  | |
 |
Michelson Interferometer |
|
 |
|
|
 |
We offer Michelson Interferometer for optical interferometry.
Michelson Interferometer Setup
- Determination of wavelength
- Refractive index of transparency slide
- Precise comparing of wavelengths
- Refractive index of air
- White light fringes
- Interference fringes
- Equal thickness fringes
Fabry-Perot Interferometer Setup
- Multiple beam Interference
- Equal inclination fringes
Twyman-Green interferometer
- Demonstration of Twyman-Green interferometer
Combination of Michelson & Fabry Perot Interferometer is Universal Interferometer.
Combination of Michelson, Fabry Perot & Twyman Green Interferometer is precision interferometer.
| |
|
 |
 |  | |
 |
Autocollimator |
|
 |
|
|
 |
It is an optical instrument used for non-contact measurement of angles. They are used to align components & measure deflections in optical or mechanical systems. An autocollimator works by projecting an image on to target mirror, and measuring the deflection of returned image against a scale.
Educational Use
| Model | Resolution | | ACT-01S | 3.0 Secs | | ACT-02D | 1.0 Sec |
Industrial Use
| Model | Resolution | | ACT-03D | 1.0Sec | | ACT-04D | 0.5Secs | | ACT-05D | 0.2Secs |
List of Accessories
- Standard Reflector
- Custom Built Reflector
- Penta Prism Std/ Precision
- Optical Polygon Std/ Precision
- Metal Polygon
Application
- Calibration of Rotary Tables
- Calibration of Surface Plates
- Alignment of Machine Beds
- Straightness Inspection of Table Movements
- Measurement of Squareness & Parallelism of Machine Guideways
| |
|
 |
 |  | |
 |
Alignment Autocollimator |
|
 |
|
|
 |
We offer all types of alignment autocollimator. Serves as a Alignment Telescope and an Autocollimator. Used for alignments of various points along a reference line as well the orientation/ angular tilt in two axis.
Application Area
- Aerospace Industry
- Bore Alignment
- Gear Box Axis Alignment
- Ship Building Industry
- Roll Alignment
- Automotive Industry
- Die Casting Industry
- Machine Tool Industry
Linear Resolution: 10 Microns shift @ 1 meter distance Angular Resolution: 1 arc sec.
Prisms India provides complete solution in design and fabrication of target fixtures to suit wide range of applications.
| |
|
 |
 |  | |
 |
Monochromatic Light Source |
|
 |
|
|
 |
Wooden Frame with acrylic white sheet for diffused/ extended light of low pressure SOX Sodium Vapor lamp.
- Model MLS1: Optical Flat to be placed on top of the specimen or component under test for viewing the light band from top.
- Model MLS-2: Specimen or the component under test is placed on top of the Optical Flat. The Light Bands or the fringe patterns are viewed through the mirror placed underneath the optical flat.
Applications
Used as a light source for Inspection of flatness of Mechanical Seals, Pump Valves, Lapped Components with Optical Flats.
| |
|
 |
 |  | |
|