The AC Power Monitor is a solid state Power Meter. The AC Power Monitor is based on Microcontroller, with a high degree of programmability.
|
AC Power Monitor | | The AC Power Monitor is a solid state Power Meter. The AC Power Monitor is based on Microcontroller, with a high degree of programmability. The Meter has been programmed to operate as an intelligent front end measuring and storing device & serial port connectivity qualifies model AC Power Meter. The Meter’s supplied preprogrammed for operation and can be directly installed. The Meter can be read manually or through a RTU using RS-485 MODBUS.
Features:
* LCD Display (2X16 Char) with Back Light * No External power is required (Draws power from the voltage signal Inputs) * Calibration: using front keys * Digital Input & Output * Isolated RS 485 (MODBUS-RTU Protocol) * Fully User Programmable * Fault log History & Fault Reset facility * Every Menu Settings are Password Protected * 3 phase 4 wire unbalanced load
Measured Parameters:
* Voltage (Ph - N & Ph - Ph RMS) * Unbalance Voltage measured (Ph - Ph Unbalance measured) * Current (Amps) * Frequency (R, Y, B) * Power Factor (Per Phase PF) * Active Power (Per Phase KWh) * Apparent Power (Per Phase KVA-Hr) * Active Energy (Per Phase KWh) * Main’s KWh * DG KWh * Run Hour (Total DG Run Hour)
Protection:
* Over Voltage Protection (Settable) * Under Voltage Protection (Settable) * Over Load Protection (Settable) * Under Load Protection (Settable) * Unbalance (Settable) * Over Frequency Protection (Settable) * Under Frequency Protection (Settable) * Total KW Protection (Settable) * Phase Failure Protection (Settable)
Enclosure:
* Mounting : Panel mounting * Position : Panel * Enclosure : 96 X 96 X 110 mm * Terminal : Screw ON Terminals
| 
 | | Send Enquiry | |
| Digital Panel Meter | 
 | We are also engaged in the sphere of manufacturing a wide range of Digital Panel Meter that are used in various applications such as Uninterrupted Power Supplies, Electrical Panels & Test benches and Genset Panels and Air conditioning & refrigeration Panels. These are able to work on temperature ranging from 5 to 60° C and available in different dimensions and weight.
Specifications:
| Aux. Supply | 1. 80 TO 280 V AC / DC 2. 48 VDC / 12 VDC As per product selection. | | Display | RED Bright seven segments, 4 Digit / 3 Digit 0.5", 0.8" segment size available. | | Indications | Set point Indication : RED LED Relay ON indication: GREEN LED ALARM indication : RED LED | | Dimensions | 96mm X 96mm X 70mm | | Panel Cut-out | 92mm X 92 mm | | Mounting | Clamp type. | | Weight | 200 gm TO 300 gm ( Depending on the product type) | | Output Contact Rating | 10 AMP. at 230 VAC ( C- NO - NC) | | Optional Features | Relay contact for Alarm, Inbuilt Buzzer, 0.8" display. | | Operating Temperature Range | -5 to 60° C. | | Relative Humidity | 95% | Applications:
- Uninterrupted Power Supplies
- Electrical Panels & Test benches
- Genset Panels
- Air conditioning & refrigeration Panels
- Motor Control Equipments
- Distribution Control panels
| | Send Enquiry |
Multi Functional Meters | | Multi Functional Meter displays phase voltages in the first row, apart from this, second row displays r-phase frequency & third row displays the ampere values of the three phases, in the scrolling pattern. According to the display, corresponding phase LED will be on.
Technical Specifications:
- Supply: 3 phase 415 v ac, 50 hz [r, y, b, n]
- Resolution: 1 v for voltage, 0.1 hz for frequency, 1a for current >=100 & 0. 1a for current <100
- Display: 3 digit 0. 5”, common cathode bright red 7 seg. LED display
- CT ratio: settable 30a/5a to 999a/5a. Default 50a/5a
- Frequency: frequency display for r-phase
- Password: separate password for setting CT ratio & current calibration (offset)
- Field Calibration: current calibration (offset) can be done at site
- Hour Counter: hour counter up to 65535.0 hrs (resolution 0.1 = 6 minutes)
- Cutout dimensions: 96 mm x 96 mm x 65mm
Area of applications:
Genset panels, Electrical Panels, Electrical Test Benches, Compressor Motors. | 
 | | Send Enquiry | |
| Voltage Monitor - VMR-3P | 
 | Protection of 3 Phase devices against Over voltage, Under voltage, Single Phasing, Reverse Phasing & Unbalance Supply are one of the major issues in electrical systems. For safe running of 3-phase devices, special protections that keep a continuous watch on supply conditions are very essential. The major cause of maximum load burn-out is overloading which occurs due to Unbalance Supply, Single Phasing & Reverse Phasing conditions. VMR-3P detects such Conditions & protect the load from burn out. 'PROTON's VMR-3P offer above protections along with 3 digit display showing R-Y,Y-B,B-R voltages in scanning mode with precise accuracy. LOW/HIGH voltage tripping to ensure trouble free running of 3-phase Loads.
Features:
- Voltage protection along with digital voltage readout
- Wide range of supply variation
- Unit will also work if any one phase is present
- Protection against Under voltage
- Indications for Low voltage, High Voltage, SPP & Relay ON
- Message Display for SPP, Reverse Phasing & Unbalance Faults
- Protection against Over voltage
- Phase unbalance protection
- Trip Delay for Under voltage & Unbalance is settable
- Reverse Phasing Protection can be able to bypass through settings
- Single Phasing & Reverse Phasing protection
- No separate auxiliary supply required
- All the set points setable by keys
- Hold feature: Press INC key in Running condition to observe particular supply voltage
Specification:
- Supply voltage: 3 Phase 415 VAC, 50 Hz (R, Y, B & N) (No auxiliary supply)
- Output Contacts: Two changeover (C-NO), Rating 5A at 230VAC
- Trip Time delay: Trip time less than 100msec for SPP, Reverse Phasing & Over Voltage
- Trip Time is settable for Under Voltage & Unbalance.
- On Delay: Selectable by keys from 1 to 60 sec
- Voltage trip setting:
- Lower Limit is 340 for under voltage (Resolution of 1 Volt)
- Upper Limit is 460 Volts for OV (resolution of 1 V)
- (Hysterisis between cut off & cut in is 10V)
- Reset Mode: Auto reset
- Operating Temperature range: -5 C to 60 deg. C
- Mounting: DIN rail
- Base mounting dimensions: 55 (W) x 65 (L) x 125 (D) mm
- Relative Humidity: 10 to 95%
| | Send Enquiry |
|

|