Creating a niche of Speciality Equipments such as Impulse Generator, Cable Fault Burning Unit, Loading Coil, Impulse Generator - 35 KV, Tracking Index, Digital Cable Fault Locator and many more items at its best, with utmost quality.


Impulse Generator

Impulse Generator

Application:

Impulse Voltage Generator is required for the application of Lightning Impulse Voltage of duration 1.2/ 50 µs between the capacitor terminals and body. The load capacitance will be of order of 1.0pF to 20nF (generally as per IS-13340-1993 and other relevant specifications)

Type Portable
Input Voltage 220 ±5% V Single Phase, 50Hz
Power 15 KJ
Impulse Voltage 300 kV Peak
Output Impulse Voltage according to IEC publication 60060 (latest version)
Wave shape 1.2/50 MS
Measuring, Display and print system Measurement of Impulse Voltage with a built in a capacitive divider, suitable oscilloscope, Laser printer to print the oscilloscope shall from the part of measuring system.
Divider Output Max. 10V at 300KV. The output of the divider shall be interface to a suitable storage. Oscilloscope/any display measuring system through a suitable attenuator along with printer. An additional GPIB/RS232 along with allied software system port shall be provided.
Efficiency Factor Worst use 90%
Charging Voltage Max. 300 kV
Polarity Positive & Negative-selectable with a switch
Impulse Capacitance Suitable capacitance for the generating capacity
Stored energy 15 KJ
Voltage Upto 100 KV
Accuracy ± 5%
Lightning Impulse Voltage Wave 1.2/50µs,
Accuracy Rise time Tail time ±30% ±20%
Specification IEC:60060

Cable Fault Burning Unit

We manufacture cable fault burning unit according to the clients needs and specification.

Capacity upto 100 kVA
Input 400/415 V 2 phases of 3 phase supply
Output 0-750/ 1500/ 3000/ 5000 V/ 10000V
Duty 5 minutes ON/OFF.

The unit is in two parts:

  1. Main Transformer
  2. Control Panel with Regulator

The Main Transformer will be step up type and will have OFF load tap changer for each voltage. Casted wheels shall be provided for ease of movement. The control Panel cum Regulating Transformer will have zero start interlocking with by-pass switch. It will have tripping on the primary side and also Ammeter, Multi range Voltmeter calibrated to indicate secondary voltage shall be provided. The unit can be used as High voltage tests upto 1000V. The unit will be designed for 5 minutes duty and will have sufficient capacity for burning fault. The Main HV Transformer and the Regulating Transformer will be oil cooled type.
Cable Fault Burning Unit
Impulse Generator

Impulse Generator

‘RE’ Impulse Generators operates under a control system, which charges the impulse generator by the  charging unit.

‘RE’ Impulse Generators operates under a control system, which charges the impulse generator by the  charging unit. Charging time and charging voltage can be selected. Once the selected charging voltage has been reached, a trigger pulse initiates the firing of the lowest spark-gap of the impulse generator. When all the spark-gaps fired all the stages are connected in series thus multiplying the charging voltage. The impulse voltage divider reduces he impulse voltage to a value that the measuring and recording instruments require.

MAIN COMPONENTS

  • Charging Rectifier
  • Impulse generator to generate lightning impulses
  • Control and measuring system.
  •  Divider.

ACCESSORIES

   
  •       Shunt  
  •       Chopping Gap / Multiple Chopping Gap.   
  •       Resistor set to generate switching impulses 250/2500.   
  •       Overshoot Compensation.   
  •       Measuring system.  
  •       Set to Generate impulse currents
Inductive Load Test Set

Inductive Load Test Set

RE’ 6kVA Inductive Load designed to testing single phase Meter Power Supply etc. 

RE’ 6kVA Inductive Load designed to testing single phase Meter Power Supply etc.    The unit shall be designed for working on 230/250V single phase 50Hz AC Supply having output voltage 0-600 V at 10 Amps.  The load is rated continuously for temperature rise test. The unit shall be complete with knob to control the current and power factor independently.

Variable Auto Transformers

Wherever voltage control is required, ‘RE’ Variacs makes it very simple by providing Toroidally wound Auto Transformer for variable voltage.

Wherever voltage control is required, ‘RE’ Variacs makes it very simple by providing Toroidally wound Auto Transformer for variable voltage. If you have not  yet used ‘RE’ Variacs you are missing some important benefits of using electric power.
 The maximum current that can be drawn depends on the size of the wire  used. The ‘RE’ Voltage regulators are manufactured from 2 A to 2000 A for Single and Three Phase.

Special Features

  •       Compact in Size.  
  •       Easy to operate.  
  •       Special Insulating Paper is used for transformer winding
  •       Guaranteed for one year against manufacturing defects.
  •       Efficient After Sales Service.

Variable Auto Transformers

Diode Test Bench

Diode Test Bench


Loading Coil

Loading Coil

Impulse Generator - 35 KV

Impulse Generator - 35 KV


Tracking Index

Tracking Index

Digital Cable Fault Locator

Digital Cable Fault Locator

 

Cable Fault Burning Unit

Send Enquiry


Resistive Load Bank

Resistive Load Bank

Inductive Load Bank

Inductive Load Bank


Inductive & Resistive Load Bank

Inductive & Resistive Load Bank

Kilo Volt Meters / Voltage Dividers

Kilo Volt Meters / Voltage Dividers


Contact us

Mr. Manish Arora (Director)
Offi:10/3, DLF Industrial Area, Moti Nagar
New Delhi, Delhi - 110 015, India
Telephone:  +(91)-(11)-43680100

Contact via E-mail

Contact via Mobile

Contact via SMS

Home | About Us | What We Offer | Site Navigation | Contact Us | Enquiry
Member IndiaMART.com © Rectifiers & Electronics. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry