We offer different kinds of refrigeration and heating equipment that are have found very diverse application around different industries. These devices are made interactive through several indicators and audio visual displays. These are also provided with some safety guards to protect against mishaps. Some of the devices produced in this range are featured below:


Hot Air Oven
Hot Air Oven
We are specailized in mnaufacturing precision engineered hot air oven, which can be availed
as per specific requirement of client.

Specification


Work Space0.5 X 0.5 X 0.5 Mt to 2 X 2 X 2 Mt
Temp RangeAmbient + 10 to 200 Deg . C
Temp. Tolerance+/ - 1 Deg . C
Temp. ControlBy Digital Temp. Controller
Temp. SensorPT 100
Power230 / 440 VAC
ConstructionDouble wall type with:
Interior20 swg CRCA sheet with Aluminium Paint
Exterior20 swg CRCA sheet with powder coating
Insulation100 mm Glass wool
DoorFull front opening,double walled
GasketHeavy duty for leak proofness
Hinges & LocksHeavy duty
MountingTrolly mounting with castors

Request for more information and quotation


Laboratory Ovens
This oven is offered by us in different dimensions with thermostatic temperature control. Its inner chamber is made using mild steel and aluminium. It has a double wall construction with glass wool insulation. Our oven has an accuracy of + / - 3° C and a temperature range of 5° C to 200° C.
Following dimensions are provided by us:
INTERNAL DIMENSIONS HEATERS
  • 300 X 300 X 300 mm 500W

  • 300 X 300 X 450 mm 500W

  • 450 X 450 X 450 mm 1000W

  • 450 X 450 X 600 mm 1500W

  • 600 X 600 X 600 mm 2000W

Laboratory Ovens
Request for more information and quotation


Dry Heat Chambers
Dry Heat Chambers
We manufacture dry heat chambers. The systems provided in this heat chamber are described below:

1Work Space 0.5 x 0.5 x 0.5 mt to 1 x 1 x 1 mt
2Temp RangeAmbient + 10 to 100°C.
3Temp. Tolerance ± 1°C
4Temp. Control By Digital Temp. Controller
5Temp Sensor PT 100
6Power 230 /440 VAC


1. PID Controller.
2. Port holes of 25 mm dia for specimen wiring.
3. Chamber On Delay Timer.
4. Specimen trays.

Request for more information and quotation


Humidity Chamber
We manufacture Humidity Chambers. The systems provided in this Humidity Chamber are described below:

1Work Space 0.5 x 0.5 x 0.5 mt to 1 x 1 x 1 mt
2Temp Range+ 10 to 100°C.
3Temp. Tolerance ± 1°C
4Temp. Sensor PT 100
5Temp Control By Digital Temp. Controller for Dry & Wet Bulb
6Humidity 95±3% in temp. Range 25 to 60°C


1. PID Controller
2. Inspection window with two Pane Glass, Heater & Lamp
3. Port holes of 25 mm dia for specimen wiring
4. Chamber On Delay Timer
5. Specimen trays.
6. Electrical terminals through wall.

Humidity Chamber
Request for more information and quotation


Cold Chamber
Cold Chamber
We are engaged in manufacturing precision engineered cold chamber, which are widely used in various engineering based appplications.

Specification


Work Space0.5 X 0.5 X 0.5 Mt to 1X1 X 1Mt
Temp RangeAmbient to - 40 Deg .C
Temp. Tolerance+/-1 Deg. C
Temp. ControlBy Digital Temp. Controller
Temp. sensorPT 100
Power230 / 440VAC
ConstructionDouble wall type with
Interior20 swg stainless steel
Exterior20 swg CRCA sheet with powder coating
Insulation100 mm Glass wool
DoorFull front opening ,double walled
GasketHeavy duty for leak proofness
Hinges & LocksHeavy duty
MountingTrolly mounting with castors


Systems provided: Air circulation Systems :-Heavy duty maintenance free motor along with suitable Fan/Impeller is provided to maintain uniform Temp. in the work space.

Refrigeration System: A single / double stage refrigeration system has been provided
to pull down the work space temp. as desired. Hermetically sealed compressor of
suitable capacity with air cooled condenser &evaporator. Ozone friendly refrigerant is
used. The system will be mounted on the bottom of the chamber. The has been designed
for continuous & trouble free operation.

Optional features:
  • PID Controller
  • Inspection window with Two Pane Glass, Heater & Lamp.

  • Port holes of 25mm dia for specimen wiring.
  • Chamber On Delay Timer. 5.Specimen trays.

  • Electrical terminals through wall

Request for more information and quotation


Burn In Chamber
Our burn in chamber has found utility in different applications across various industries like rubber, automobile, electronic and glass etc. It is provided with interactive safety devices with MCB and audio visual indication. The systems provided in this Burn In Chamber are described below:


TD>230 /440 VAC
1Work Space 0.5 x 0.5 x 0.5 mt to 1 x 1 x 1 mt
2Temp RangeAmbient + 10 to 80°C.
3Temp. Tolerance ± 1°C
4Temp. Control By Digital Temp. Controller
5Temp Sensor PT 100
6Power


1. PID Controller.
2. Inspection window with two Pane Glass & Lamp.
3. Port holes of 25 mm dia for specimen wiring.
4. Chamber On Delay Timer.
5. Specimen trays.

Burn In Chamber
Request for more information and quotation


Water Chiller
Water Chiller
Range : 0.5 Tonnes to 5.0 Tonnes
Application : Die – Mould Chilling / Oil Chilling / Chemicals Chilling etc.
We are specailized in offering high quality Water Chiller, which compromises of stainless stell storage trank as well as refrigration systems, whuichg consists of hermetically sealed compressor with air condenser and static type evaporator. The entire unit is fabricated and housed in M.S Square pipe frame with CRC power-coated panels and locks, mounted on heavy duty castors for ease of mobility.

Controls and Protections:
  • Single Phase Preventor provided to avoid single phasing. (Only for 3 phase system)

  • L.P switch: switches OFF the compressor, in case of any low pressure develops in refrigeration system.

  • H.P. Switch: switches OFF the compressor, incase of any low pressure develops in refrigeration system.

  • Solenoid valve: Ensures fast equilisation of Refrigerant. ON
  • delay timer: To protect compressor from overloading during operation.

  • M.C.B"s : To protect entire unit / control circuit / water – pump.

  • Water-level controller: To ensure minimum water level.
  • Temperature Indicator controller: Display and control the set temperature.(Range ambient to 6°c)

  • Temperature Indicator: To monitor return water temperature.
  • Water filter: Filters the return water.

Request for more information and quotation