Sanket ElectricalsNashik, Maharashtra | Year of Establishment: 1965 |
PRODUCTS & SERVICES |
Earthing Electrodes (1)Electrical Engineering Consulting Services (7)Grounding Minerals (1)Licensing Services (1)Power Transformer (1)Tally Services (1)UPS, INVERORS & BATTERY (1)Virtual Marketing (6)Water Heater (1) | Earthing Electrodes
Earthing Electrodes![]() Earthing Electrodes/Chemical Earthing/Maintainance Free Electrodes We are offering earthing electrodes. Our range of earthing electrodes are available with following features: ASHLOK Safe Earthing Electrode - The major application for said product are Low/Medium/High/Extra High Voltage applications, Domestic, Industrial, Telecommunication, Sub station & Power Generating Stations, Equipment Body & Neutral Earthing, Sensitive Electrical/Electronic Machines, Lightning Arrestor, Diesel Generators, Etc. The Advantages & Benefits are
Scope of Supply A. Material Supply Safe Earthing Electrode: - Safe Earthing Electrode is normally available in 1 Mtrs., 2 Mtrs. & 3Mtrs length, which can be decided on the soil condition and load application. Back Fill Compound: - The quantity of BFC depends upon the soil condition. As per the standard practice, 1 Bag of 25 Kgs is Supplied with 1/2 Mtrs long electrode and 2 Bags with 3 Mtrs long electrode additional bag can be supplied if needed at Extra Cost with your prior intimation. Recommendation: - In case of very Hard / Rocky Soil it is recommended to increase the depth of the bore to about 5 Mtrs with an additional bag of BFC. This is just a suggestion as the practice mentioned above has encouraging results. Many Electrical Consultants are recommending the same. B. Installation Boring: - As a standard practice we need to take a bore of 150mm Dia. for installation. For this, one has to arrange boring rig mounted on truck chassis. Arranging the boring rig may take a couple of days depending on the availability. C. Civil Works: - We normally do not undertake civil works like construction of protective civil chambers of installed earth pits and connection of G.I. / Copper Strips to the electrode . However, this work can be carried out at an Extra cost . Precaution: - As soon as the electrode is installed, the uppermost portion of the electrode should be protected with protective chamber with cover so as to prevent any damage. |
| |||||||||||
| Companies | Products | Trade Leads | Tenders | Trade Shows | Travel |
© 1996-2012 IndiaMART InterMESH Limited. All rights reserved worldwide. |