Biotech Instruments
With the support of adept workforce, we design and develop wide assortment of industry standard biotech instruments. These are offered in various technical specifications and designs to meet the specific requirements of our client. Our UV-VIS spectrophotometer finds application in determination of nutrients including N, P, K, S, Ca and others and organic components present in plants and agricultural soil. Our precision engineered flame photometer efficiently measures the concentration of alkali & alkali earth metals in geological & agricultural soil testing, food & beverage testing and others.
Wide range of instruments offered by us includes:
|
View Enquiry Basket
Atomic Absorption Spectrophotometer We are one of the leading manufacturers and exporters of highly efficient atomic absorption spectrophotometer. These are offered to our clients with customized solution as per their technical specification. Modes of operations of the instrument include absorbance, concentration, standard addition & emission. The range is stringently checked by our quality team prior to its dispatch at client end.
Features of atomic absorption spectrophotometer include:
Microprocessor based, user friendly, menu driven, with printer interface
Optional PC Compatibility with RS 232C Interface and MS Windows® based Software for data acquisition, processing, storage, retrieval & interpretation of data
Continuous source background correction
Quick change and easy alignment of hollow cathode lamps with standby warm-up facility
Precise vertical, lateral and rotational alignment of Titanium Burner
Optimal parameters storable in built-in memory
Self diagnostic
Specifications:
| Spectral | | Range | 190 to 900 nm | | Accuracy | ± 0.5 nm | | Bandwidth | 0.15 to 3.0 nm variable in steps of 0.15 nm | | Photometric | | Range | 0 to 2 Abs | | Accuracy | ± 0.01 Abs at 1 Abs | | Integration Time | 0.04 to 99 Sec | | Light Source | Hollow Cathode Lamp (HCL)* | | Background correction | Deuterium Lamp (D2)* | | Burner | Titanium Construction Premix, Laminar flow, 100 mm | | Fuel | Acetylene (C2H2) | | Oxidant | Air/Nitrous Oxide (N2O) | | Flow Control | Integral gas control system with panel flow meters | | Nebulizer | Pneumatic, with 90% Platinum, & 10% Iridium alloy Capillary* | | Sample Feed Rate | 3 to 8 mL/min (Adjustable) | | Monochromator | Czerny Turner 300 mm with 1200 lines/mm Holographic diffraction grating & Hard coated optics | | Slits | Bilateral continuously variable of 0.15 to 3.0nm spectral bandwidth | | Detector | Wide Range Photomultiplier tube (PMT) | | Readout | 24x2 Dot matrix LCD panel with backlight of 2.70 x 5.5mm character size | | Power Supply | | HC Lamp | 0 to 30 mA, modulated | | D2 | 15 to 300 mA, modulated | | PMT | -200 to -1000 V | | Power requirement | 230 V ± 10%, 50 Hz, 1 , Max. 200 VA | |  | Add to Enquiry Basket |  |
Flame Photometer  | Our flame photometer is globally appreciated for its features including dimensionally accurate, compact designs, easy operation and heat resistant. The instrument is developed using grade raw material and technology. It is available to our clients in customized packaging ensuring scratch free flame photometer dispatched at client end.
Features:
Dual Channel
Concentric Non-corrosible Nebulizer
Mixing Chamber designed for stable flame
Flame System: Stainless Steel round burner with LPG as Fuel & Air as Asoxidant and stainless steel needle type regulator
Narrow Band interference Filters
Small quantity of sample needed
Applications:
It finds applications for measurement of Concentration of Alkali & Alkali earth metals (Sodium, Potassium, Calcium & Lithium) in geological & agricultural soil testing, pollution monitoring & control, food & beverage testing and cement. In addition, it is also used to measure the concentration of the alkali and alkali metals in coal, chemicals, ash, fuel & greases, crude oil, glass, acids, pharmaceutical and other industries. |  | Add to Enquiry Basket |
Brookfield Viscometers With our industrial experience gained in a decade, we develop high performing brookfield viscometers. These are designed and fabricated in compliance with the global standard. In addition, it is also offered as per the technical specifications provided by our clients. It finds application for measurement of viscosity at high shear rates. It uses less than 2 ml of sample and thus helps in avoiding excess cleaning and material costs. Other features of our brookfield viscometers include following:
LCD display of viscosity in Poise or Pascal-seconds
Automatic viscosity range calibration and cone gap positioning make the viscometer easy to use
Set the viscometer to take a reading at different timed intervals to ensure accuracy of results with thixotropic fluids. |  | Add to Enquiry Basket |  |
Electrophoresis Unit  | We specialize in designing and manufacturing precision engineered horizontal gel electrophoresis unit. Backed by our proficient team, we develop the unit as per the industry standard. It is specially designed for analysis of 10 samples and 1 marker. A gel-casting tray of size 110mm x 90 mm along with an 11 well comb are provided the horizontal unit. Other accessories including a safety lid and electrical connectors are also offered with it. |  | Add to Enquiry Basket |
UV-Vis Spectrophotometer Our company offers wide range of UV-VIS spectrophotometer which is fabricated in conformity with international standard. The collection is also designed and developed in accordance with the client specifications and requirements. It finds application in laboratories, research institutes, textile & leather industry and many others.
Following are the features of our compact UV-VIS spectrophotometer:
Microcontroller based
High Signal to Noise ratio
Stable single beam optics
Push button selection of % T, Abs & Conc.
Compact, Modular & ergonomically designed
Simple selection of four position sample holder
Accommodates cuvettes of upto 40mm path length
Its applications are in determination of
Nutrients like N, P, K, S, Ca, Mg, Zn, Cu, B, Mo etc., in Agricultural soil, plants and others
Organic components in Plants and Biological matter
Glucose, fructose, carbohydrates, proteins etc, in foods
Edible dyes alcohols etc., in beverages
Purity of constituents in pharmaceuticals
Toxic elements Cd, Pb, Hg etc., in effluents
Constituents in compositions used in metallurgy, fertilizer, pesticide, chemical,
petrochemical, steel, cement, glass & other industries.
Specifications:
| Spectral | | | Range | 190 to 1000 nm | | Bandwidth | 2 nm | | Accuracy | ± 0.5 nm | | Repeatability | ± 0.2 nm | | Readout | 4 digit 7 segment LED Display of 12.7 mm height | | Readability | 0.1 nm | | Photometric | | | Range | 0 to 2 Abs | | Accuracy | ± 0.005 Abs. at 1.0 Abs ± 0.010 Abs. at 1.5 Abs | | Repetability | ± 0.002 Abs. at 1.0 Abs | | Stability | ± 0.003 Abs/hr. after 2 hr. warm up | | Stray light | < 0.1% T at 302 nm | | Readout of Abs., %T & C | 3½ digit 7 segment LED Display of 12.7 mm height | | Readability | ± 1 Count | | Light Sources | Deuterium(D2) & Tungsten (W) Halogen Lamps | | Monochromator | Czerny Turner with High resolution 1200 lines/mm Holographic Grating | | Detector | Wide range Photo Diode | | Power Requirement | 230 V ± 10%, 50 Hz, 1 ,Max. 150 VA | |  | Add to Enquiry Basket |  |
Colorimeter  | We specialize in designing and manufacturing precision engineered colorimeter in compliance with industry standard. The instrument is also developed as per the client specifications and requirements. It is highly in demand in laboratories, clinics and pharmaceutical industry for determining concentration of constituents in medical institute, textile industry and others. It also finds application in food, beverage & water analysis. In addition, it is also used in analytical & agricultural chemistry and metallurgy.
Features:
Stable, Direct Readout of Absorbance
Compact & Easy to operate
Rugged, Sturdy & Reliable
Thumb Wheel Selection of Filters
Pre-focused Light Source
Long Life Photo Diode Detector
Only 1 ml of Sample need
Usable for Disposable cells
Specifications:
| Photometric | | Range | -0.1 to 1.99 Abs | | Repeatability | ± 0.01 Abs | | Stability | ± 0.01 Abs in 8 h | | Light Source | Tungsten Lamp | | Filters (8) | Peak Transmission at 450, 470, 490, 520, 540, 570, 600 & 670 nm | | Shutter | To prevent the detector from continuous exposure to light | | Detector | Photo diode | | Readout | 2½ Digit 7 segment LED display of 12.7mm height | | Power Requirement | 230 V ± 10%, 50 Hz, 1 , Max. 20VA | | Physical Dimensions | | Size (WxDxH) in mm | 270 x 180 x 110 | | Weight in Kg. | Approx. 3.0 | | Accessories Supplied | | With Instrument | Matched 3 mL test tubes, holder for 10mm path length glass cuvettes disposable cells | | At Extra cost | Glass cuvettes & disposable cells | |  | Add to Enquiry Basket |
HPLC System Our HPLC System is precisely engineered in conformity with global standard. It is widely acknowledged for dimensionally accurate, compact designs, easy operation and heat resistant. Our collection finds wide application in laboratory, research institute and many others.
Isocratic Pump
Following are the technical specifications of isocratic pump:
Flow: 0. 01-10mL/min / 0.001-9.999
Max. Pressure: 40MPa
Dual Piston designed with main and auxiliary pump heads connected in series
Intuitive operating using simple keypad allows easy chose functions as follow:
Flow rate
Maximal flow rate PURGE (for priming and washing)
Low pressure
High pressure limit
Pulsation compensation on-off
Pressure unit (PSI,Mpa or bar)
Control mode (by keypadm RS 232 or using voltage)
Display brightness
Possibility to use this pump by high pressure gradient mode, where are two three or four unit controlled from PC using RS232 or voltage
UV-VIS Variable Wave Detector
Our highly efficient UV-VIS variable wave detector is precisely engineered as per the industry standard. Following are specifications of the detector:
Detector Wavelength Range : 190-600 nm (Optional:600-800nm)
Noise Level: +/-0.3 x 10-5 AU
It may be used for analytical chromatography as well as preparative chromatography
Reference and sample signals available for detector diagnostics as well as information on lamp operating hours
Out put signal is both digital and analogue
It is possible to control the unit using the keypad or an RS232 interface
D2 lamp in a special socket that enables easy changing
Wavelength can be programmatically changed
Automatic Wavelength Calibration. |  | Add to Enquiry Basket |  |
Potentiometers  | Our company offers compact designed potentiometers to our clients. Fabricated in compliance with the international standard, the range is globally accepted for its high performance. Our assortment is used for potentiometeric measurements. Results of the instrument are displayed by light emitting diodes (LED) in milli volts on a direct digital readout.
Specifications:
| Range | 0 to+ 1999.9mV | | Resolution | 1 mV | | Repeatability | + 1 mV | | Accuracy | + 1 mV +digit | | Input Impedancy | 10 ohms | | Operating Temperature | 10 to 50oC | | Display | 3 1/2 Digit 0.5 seven segment LED display Indication | | Power | 230V + 10%AC, 50Hz | | Dimensions | 76 x 275 x 170 mm. | | Weight | 2 Kg (approx.) | | Standard Accessories | | Electrode | 2 Nos. | | Dust Cover | 1 No. | | Electrode Stand | 1 No. | | Manual | 1 No | |  | Add to Enquiry Basket |
Dissolution Tester Our tablet dissolution test apparatus is developed from grade raw material. With the support of our proficient team, the apparatus is designed and manufactured as per the USP Standard. Featured with defect free structure, dimensionally accurate and light in weight, the apparatus is widely accepted by our reputed clients. It efficiently works for single tests of capsules or tablets. |  | Add to Enquiry Basket |  |
Tablet Hardness Tester  | We specialize in designing and developing precision engineered tablet hardness tester. Our tester can be fitted on either bench or tablet ling machine. It is offered with various precision engineered components including engineered Dial Gauge, Aluminium Body and others. Follow pointer records force on Dial Gauge while main pointer goes back to zero.
Specifications:
Capacity 0-200 Newtrons
Accuracy + 5 Newtrons |  | Add to Enquiry Basket |
Digital Turbidity Meters Our digital turbidity meters are globally known for giving reliable and accurate results. The digital turbidity meter is fitted with 3 ½ digit LED Display which can measure upto 1000 JTU. It finds applications in sewage and drinking water testing. Our collection is acknowledged for defect free structure, dimensionally accurate and light in weight.
Measurement:
| Range | 0 to 200 JTU 0 to 1000 JTU 2 Ranges | 0 to 20.00 NTU 0 to 200.00 NTU 2 Ranges | | Resolution | 1 JTU | 0.1, 1 NTU | | Accuracy | +3% FS + 1 digit | +2% FS + 1 digit | | Sample System | 30 mm clear glass tube | 30 mm clear glass tube | | Light Source | 6.8 V, Tungsten Lamp | 6.8 V, Tungsten Lamp | | Detector | Photodiode | Photodiode | | Display | 3 1/2 digit LED display | 3 1/2 digit LED display | | Power | 220V+ 10% AC 50 Hz | 220V+ 10% AC 50 Hz | | Size (LxBxH) | 305 x 305 x 165 mm | 305 x 305 x 165 mm | | Weight | 4 kg (approx.) | 4 kg (approx.) | | Accessories | Test Tube Set, Operation Manual & Dustcover | | Other Models | Analog Nephelometer Battery cum Mains Operated also Available | | Product Range | Photo Colorimeters, Spectrophotometers, Digital pH Meters, Conductivity/TDS Meters, Turbidity Meters, Digital D.O. Meters, Water & Soil Analysis Kits | |  | Add to Enquiry Basket |  |
Moisture Titrator  | We design and fabricate precision engineered Karl Fischer moisture titrator. Available in various specifications, the titrator can be customized in accordance with client requirements. Featured with compact designs, easy operation and efficiency, our assortment has received wide accolade in diverse industries.
Specifications of our most advanced Karl Fischer moisture titrator are tabulated below:
| Range | 0.1mg - 500mgH2O, 10ppm - 100%H2O | | Burette | Capacity 10mL x 2 Precision ±0.015mL | | Display | 30 digits x 7 lines LCD with back light | | External I/O | 1. Printer 2. Balance 3. Computer via RS232C | | Output | H2O, concentration, dialogue messages | | Ambient condition | 5 - 35°C, less than 85%RH | | Power | 100 -120/200-240V AC, 50/60 Hz | | Power consumption | 35W | | Dimension | Main: 288(W) x 468(D) x 629(H) mm Stirrer: 120(W) x 225(D) x 320(H) mm Solvent change unit: 240(W) x 170(D) x 405(H) mm | | Weight | 13.5kg | |  | Add to Enquiry Basket |
Water & Soil Analysis Kit We specialize in designing and fabricating superior quality water and soil analysis kit. It is made available to our clients with 3 ½ digit LCD Display. Our efficient kits are mains cum battery operated. It gives accurate result for soil and water analysis. Some of the salient features of our range:
Measures pH, mV, Conductivity
TDS, DO, Temperature & Turbidity
Housed in VIP Briefcase
Measurements:
| Model pH | Range | SI - 60 | SI - 61 | SI - 62 | | 0 to 14pH | 0 to 14pH | 0 to 14pH | | Temp. Comp. | 0oC (Manual) | 0oC (Manual) | 0oC (Manual) | | Resolution | 0.01pH | 0.01pH | 0.01pH | | Accuracy | +0.01 pH | +0.01 pH | +0.01 pH | | O.R.P./mV | Range | N.A. | 0 to + 1999 mV | 0 to + 1999 mV | | Resolution | 0.01pH | N.A. | 1 mV | | Accuracy | N.A. | + 1 mV + 1 digit | + 1 mV + 1 digit | | Conductivity | Range | 1 | 5 | 5 | | Cell Constant | 0.4 - 1.5 Adj | 0.4 - 1.5 Adj | 0.4 - 1.5 Adj | | Resolution | 0.1 Micro mhos | 0.1 Micro mhos | 0.1 Micro mhos | | Accuracy | + 0.5% FS | + 0.5% FS | + 0.5% FS | | Temperature | Range | 0o - 100oC | 0o - 100oC | 0o - 100oC | | Resolution | 0.1oC | 0.1oC | 0.1oC | | Accuracy | +0.1oC + digit | +0.1oC + digit | +0.1oC + digit | | T.D.S. | Range | 1 | 5 | 5 | | Cell Constant | 0.4 - 1.5 Adj | 0.4 - 1.5 Adj | 0.4 - 1.5 Adj | | Resolution | 0.1ppm | 0.1ppm | 0.1ppm | | Accuracy | +5% FSD | +5% FSD | +5% FSD | | D.O. | Range | 0-20 ppm | 0-20 ppm | N.A. | | Temp. Comp. | 0.1 ppm | 0.1 ppm | N.A. | | Resolution | +0.3 ppm | +0.3 ppm | N.A. | | Accuracy | 5o to 50o (Manual) | 5o to 50o (Manual) | N.A. | | Turbidity | Range | 0-1000 NTU/JTU | N.A. | N.A. | | Resolution | 1 NTU/JTU | N.A. | N.A. | | Display | Selenium Photocell | 3 1/2 digit LCD display | | Power Suppy | 6.8v, 300mA | 1.5V x 6 Dry Cells or 230V + 10% 50 Hz | | Accessories | 230v + 10% and In-built Battery | pH Combination Electrode, Conductivity / TDS Cell, DO Probe, Temp Probe, Standard Solution, D.O. Memberanes, Cell Container & Instruction Manual | | Product Range | Photo Colorimeters, Spectrophotometers, Digital pH Meters, Conductivity/TDS Meters, Turbidity Meters, Digital D.O. Meters, Water & Soil Analysis Kits | |  | Add to Enquiry Basket |  |
BOD Test Kit  | Biochemical Oxygen Demand (BOD) test aims to determine the concentration of oxidizable and biodegradable organic compounds in water. The test most often runs for a five day period. Its widest application is in measuring waste loading of treatment plants, and in evaluating the efficiency of treatment processes. CheckLight scientific development team has developed a unique technology for determination of BOD in water in only 3-4 hours.
Features -CheckLight BOD Test :
Principle-
The tested water sample is pre-hydrolysed with acid and exposed to the bacteria. The obtained level of luminescence reflects the concentration of utilizable organic carbon compounds in water.
Bioassay -
Freeze-dried luminous bacteria.
Fast -
Results are obtained within 3-4 hours.
Sensitive -
A vast range of organic compounds can be detected at a wide concentration range.
User-friendly -
Minimal lab experience is necessary. A simple three-step procedure. Only 1mL of sample is necessary to run the assay, making collection, storage and disposal of sample material easy and cheap.
Equipment -
CheckLight luminometer, pipettor, tips.
Reliable -
Good correlation was obtained against the standard BOD test for a given water source.
Cost effective -
Low price encourages more frequent monitoring of treatment plant efficiency and allows rapid response to changing conditions. |  | Add to Enquiry Basket |
|
What We Offer

|