We offer a wide range of circuit starters and breakers as well as soft starters that are available in both standardized and customized designs. Our product quality is continuously enhanced to deliver dependable and fault free products on time every time.
Our products are manufactured, using superior quality raw material to ensure the durability and efficient functioning of our range. Our range include:
 |
|
|
 |
|
| Soft Starters Our
range of soft starters is a general purpose AC motor soft starter
industrial package. It provides a complete and effective AC motor
starting and protection solution with it's GPH starters built for
ruggedness and reliability. These are designed for simple and fast
installation and start-up, requiring only input power and output
motor connections. The use of superior quality raw material makes the
entire range more desirable. Applications:
- Pumps
- Fans
/ Blowers
- Conveyors
- Compressors
- Agitators
- Crushers
- Saws
Features:
- 5
- 150HP at 230V and 10 - 300HP at 460V
- Wall
mount enclosure suitable for dusty, wet or outdoor applications
- Circuit
breaker with door mounted operator provides built-in short circuit
protection and input power disconnect
- Automatic
bypass contactor
- Fused
Control Power Transformer (CPT)
- Start
and Stop Pushbuttons and Run and Fault Pilot Lights on the front
cover
- Terminals
for 2 or 3 wire remote Start/Stop
- Keypad
with protective cover mounted on enclosure door
- All
parameter changes are through the cover-mounted keypad.
- Dust
and water stay out of the enclosure.
- Monitoring
of current, voltage, kVA and kW can be done from the outside.
- AC3
rated bypass contactor and motor overload relay is standard on 5 -
30HP / 230V and 10 - 75HP / 460V
Optional
Features:
- Keypad
mounted inside enclosure
- No
circuit breaker
- Legs
for free standing enclosure
- AC3
rated bypass contactor with motor overload relay
- 575V
units are available.
| |
 |
|
|
|
 |
|
|
 |
|
| Stator Rotor Starters We manufacture Oil Immersed Stator-Rotor Starters that are designed for use on Voltages up to 550 Volts. H.P. 330 HP. These starters comprise of separate Stator Controlling OCB and Rotor Controller mounted on the same base frame made of galvanized steel making it durable and efficient in working. We offer these at very affordable prices. Operating Mechanism :
- Is interlocked with Rotor Controller and the OCB cannot be switched ON until and unless the full external resistances are inserted in the circuit
- The Rotor Controller and OCB are connected strictly as per the circuit diagram
- The OCB is closed by putting the handle to "ON" position
- The push button provided with the Rotor Controllers is kept pressed till the resistance cutting "wheel" of the Rotor Controller is rotated to full "ON" position.
Contacts :
- The Stator Controlling OCB's are provided with heavy type copper contacts to ensure a trouble free life
- The contacts are made from hard drawn electrolytic copper strips
- Each unit is provided with two sets of contacts : arcing contact and main contact
- The arcing contacts make before and break after the main contacts, thus confining burning to the arcing contacts
- The main contact scarcely calls for replacement where as the arcing contact can be replaced very easily
Protection:
- Overload Protection - is of magnetic type with oil dash pot time lag arrangement in all three phases.
- Under Voltage Protection - is provided by a closing type solenoid coil.
Accessories:
- Are generally provided with incoming and outgoing cable entry plates
- Cable boxes for paper insulated cables, fully interlocked isolator and ammeter can also be provided, on request
Rotor Controller:
- Is designed to comply with latest IS for use in Rotor Circuit of A.C. Slipring Motor
- Adequately rated resistance wires are selected as per the current at various steps and are robust in design
- The Rotor resistance is based on the Rotor Volts and Rotor Amps of the Motor
- The cutting off resistances are achieved by the rotation of CAM operated "wheel" and this provides smooth starting of the motor.
Special Features:Foolproof interlocks are provided in the Starter as per the following :
- The Motor can be started only when full Rotor resistance is in the Rotor Circuit. Otherwise the Stator controlling OCB will not close.
- The motor cannot be left running with rotor resistance in the circuit. If by any chance the rotor resistance is left in the circuit the starter will trip no sooner the push button on the rotor controller is released.
| |
 |
|
|
|
 |
|
|
|
 |
|
 |
Automatic Star Delta Starters We supply our top quality automatic air break star delta starters type CSD/A for starting of squirrel cage induction motors. These comply to BSS 775 and BSS 587 and are suitable for 40 starts per hour. The product is offered at reasonable prices. Construction:
- Totally enclosed, in a deep-drawn sheet metal casing, wall mounting type, suitably gasketted to make it dust proof
- The entire starter assembly (which is mounted on a steel plate) can be taken out of the casing by removing four screws only.
- Maintenance is facilitated by taking the interior out for repair while a spare interior can be inserted.
Rating:
- The automatic star delta starters are ideal for controlling motors upto 40 HP at 400/440 volts or 500/550 volts
- Adjustable Timer is incorporated for automatic changeover from Star to Delta.
Protection:
- Are provided with magnetic type overload releases with an adjustable oil dashpot time lag device on all the three phases
- The magnetic overload device, which works on the magnetic principle of current, is totally independent of the ambient temperature, provides a positive and direct protection to the motor
- Non-aging properties inherent to the magnetic overload device ensures the same protection to the motor even after years of service
- Can also be fitted with thermal type bi-metallic overload releases with temperature compensation devices
- The overload device is of the Hand-Resetting type which is an essential feature where remote control is required.
- The under voltage protection is inherent
Control:
- Start and Stop/Reset Push Buttons are provided on the front cover
- Remote control terminals are also provided for remote operation by means of limit switch, float switch, pressure switch or a separate push button unit.
Isolator:
- A rotary type triple pole air break isolating switch can be provided on starters, the operation of which is interlocked with the lid of the starter
- Ensures that the starter lid cannot be opened till the isolator is in the OFF position.
Cable arrangements:
- Units are provided with entries for conduit connections
- Sealing boxes can be provided for underground paper-insulated cables.
Earthing:
- Double earthing terminals are provided.
Timer:
- Special current activated change-over Timer ensures transition from Star to Delta at approximately the rated current of the motor only, irrespective of the transition time which depends on the drive
- This leads to no wear on the contacts due to transition kicks.
| | |
 |
|
|
|
|
 |
|
|
 |
|
| Star Delta Starters & Circuit Breakers We
offer star delta starters
and circuit breakers type SMSD-50/SMSD-200 that are designed for use on Voltages
up to 550V. The starters and breakers are designed in both
standardized as well as per client's specifications. The use of
high-grade raw material further ensure world- class products. Rating:
- Star-delta
— 225 H.P.
- Direct-on-line
— 150 H.P. on request
- Circuit
Breaker — 400 amps.
Construction:
- Main
body and the oil tank of sheet metal
- Enclosure
is both moisture and dust proof
Operating
Mechanism:
- Have
a standard 'fixed' handle but can be provided with free handle as
well
- Free
handle is a standard feature with circuit breakers.
Contacts:
- Are
provided with heavy type copper contacts made from hard drawn
electrolytic copper sections to provide trouble free life
Protection:
- Overload
protection - is of magnetic direct acting type with adjustable oil dashpot time
lag arrangement
- Provides
positive protection against single phasing being connected in phase
circuit.
- Under
voltage protection- is provided by a closing type solenoid coil.
Accessories:
- Are
provided with incoming and outgoing cable entry plates
- Cable
boxes for paper insulated cables, fully interlocked isolator,
ammeter, voltmeters, earth leakage relay, bus bars, single phasing
preventer, remote stop provision, floor stands, etc., can also be
provided on request
- Starter
& OCB are supplied without 1st Filling of oil.
| |
 |
|
|
|
 |
|
|
|
 |
|
 |
Automatic Combined Stator We
supply fully automatic combined stator and rotor starters type PRS that
comprise of an air break contactor with over current and under
voltage protection for the stator and set of accelerating contactor
along with automatic timing devices. These enable the motor to run
up-to the speed in a pre-determined time. These are manufactured to
conform to IS : 13947 Part-1 section 4 quality standards and are normally
suitable for 15 operations per hour. Contactor: Air break contractor confirming AC III Timers: Electronic timers to adjust no of steps and time delays. Overload
Relay:
- Can
be provided with either electro-magnetic oil dash pot time lag over
current release or bimetallic type thermal relays
- Give
the necessary inverse time characteristics for protecting the
connected equipment
Resistance
unit:
- Can
be either of nichrome round or fiat strip or cast stainless steel
grids
- Stainless
steel grids are given for units above 100 HP
- Wire
wound resistances are supplied fro lower HP
Controls:
- Start,
Stop and Reset push buttons, are provided on the front cover
- Terminals
are also provided for remote operation by outside signals.
Isolator:
- Can
be fitted quick make and quick break isolators
- Its
operation can be interlocked with the front cover.
Instruments
and Cable Arrangements:
- Provision
is made for mounting metering instruments
- Blank
gland plates are provided for fixing cable glands
Rating:
- Standard
ratings are up 40 HP to 400 HP at 415V and 2000 HP at 6.6KV
- Specific
details regarding rotor volts and rotor currents should be supplied
with the inquiries.
| | |
 |
|
|
|
|
 |
|
|
 |
|
| Power Distribution Panel We offer a wide range of power
distribution panels. These are used to distribute direct current
power from one supply to other devices. The main task of power
distribution panel is to monitor and protect DC Systems. Our power distribution panels are used as:
- Shorted output device
- Heater current indication
- Loop break alarms
| |
 |
|
|
|
 |
|
|
 |
|
| Capacitor Control Panel We offer highly customized & effective capacitor control panels. Our capacitor control panel are widely used in various industrial unit. Our panel came with a power circuit consisting of contractor, MCB and fuses.
Product Information
We selected the field of energy conservation or energy saving, witch is a need of the time and is receiving attention from the governments and from private sectors as well. Out of various various electrical fields this area is one part , is a subject of our expertise and experience.
Power factor is the ratio between true power and apparent power, Thus, P.F. = KWH / KVAH Here, KWH is an abbreviation for Kilo Watt Hour or Unit. KVAH is an abbreviation of Kilo Volt Ampere Hour.
This ratio is normally a fraction figure but ideally should be 1.0 (Unity) or as close to unity as possible. This ratio is called power factor. Any value of power factor near to unity is called good P.F. and similarly below 0.92 is assumed as poor power factor.
Power Factor - The power factor of any power consuming centre depends upon three types of loads being used in present day industries. To explain, normally there are three kinds of loads present in any industry, individually or in combination.
Resistive load: Under this condition the P.F. is always 1.0, i.e. unity. This is an ideal situation. This is achieved with loads like resistive heaters, filament lamps etc.
For disadvantages of maintaining poor P.F., Click the image to see the description
| |
 |
|
|
|
 |
|
|
 |
|
| Variables Frequency Drives We
offer a range of variable frequency drives that are available in 6
control modes and are offered at competitive prices. These drives
accomplish part load control by varying electric motor speed,
significantly reducing energy waste. Features: Available
in 6 Control Modes:
- V/f
variable torque control
- V/f
constant torque control
- Sensor
less vector control
- Closed-loop
vector control
- Sensor
less PM motor control
- Closed-loop
PM motor control
Are
Environment-friendly:
- Optional
built-in EMC filter (up to 30kW at 400V series, 5.5kW at 200V
series.)
- Optional
built-in DC reactor (37kW at 400V series, 22kW at 200V series,and
above)
- RoHS
Directive compliant
- Selectable
Soft-sounds
- High-efficiency
operation
- Dioxin-free
plastic cases
Available
in Global Design:
- UL, CUL and CE compliant
- Field
bus interfaces (Modbus, Profibus-DP, DeviceNet, CANopen, CCJJnk)
- LED
display as standard
- Multi-language
LCD monitor as option
Other Features:
- User-programmable
built-in PLC
- Application-specific
features
- Multi-pump
control
- PID
control
- Traverse
control for fibre machines
- Spinning
ring frame
- Energy
optimizer
- Elevator
program
| |
 |
|
|
|