 Showcase View all our products / services as a slide show. play now
 |
 |
Lift Inverters
|
We are engaged in manufacturing and supplying 3-Phase Lift Backup Systems or Lift Inverters that are designed and developed using latest and advanced technologies. These include Lift Inverter, Three Phase Lift Inverter – Lifton 5 KVA, Three Phase Lift Inverter – Lifton 10 KVA and Three Phase Lift Inverter – Lifton 100 KVA. The detailed description of our range of 3-Phase Lift Backup Systems or Lift Inverters is as follows:
|
View Enquiry Basket
| | Lift Inverter (Item Code : LIFTRON-Series) We offer Lift Inverter - LIFTRON Series that are known as Emergency Lift Operating System. These are offered with Pure Sinewave and 3 Phase Balanced & Unbalanced Load to meet the needs of the clients properly. These are designed using IGBT Based Technology for high inductive Load. Our Lift Inverter -LIFTRON Series are appreciated by the clients for Large Capacity and High Efficiency. The technical specifications for Liftron series are as follow: | Model | THREE-PHASE OUTPUT | | Rating | 6KVA to 100KVA | | AC Input | 415V + 15%, -20% Three Phase Input | | Frequency | 50Hz +/- 6% | | DC VOLTAGE | 72 VDC TO 360 VDC | | Charging Time | 12 Hours for 90% of Full Capacity | | Charger Type | Internal Controlled Rectifier Type | | INVERTER | IGBT, High Frequency PWM | | Technology | 400V / 415V AC Three Phase, Balanced | | Output Voltage | +/ - 1% for DC I/P Variation & O/P Load Variation | | Voltage Regulation | 50Hz + 0.5Hz | | Frequency | PWM Sine Wave | | Waveform | Less Than 3% | | Harmonic Distortion | >93% for 360 VDC | | Inverter Efficiency | >90% for 180 VDC | | Power Factor | 0.8 105% Continuously | | Overload | 300% for 60 sec | | Crest Factor | 4:1 | | Transient Response | +/- 4% Under Full Load Change and Corrected Within 60msec | | Phase Displacement | 120 Deg. +/- 1% | | Audible Noise | Less than 45 dB at 1 Meter | | | Add to Enquiry Basket |
| Three Phase Lift Inverter (Item Code : Lifton-5KVA) We offer Three Phase Lift Inverter - Lifton 5 KVA that are assured to have high quality standards. These are offered with metering using microprocessor based digital LCD meter for R, Y, B output voltages, output currents & frequency, DC voltage, battery and load percentage, last 5 backup time storage with no. of lift operation per backup. Our Three Phase Lift Inverter - Lifton 5 KVA are offered with protections from output overload & short circuit, output under & over voltage, DC under & over voltage input under & over voltage, single phasing & phase unbalance. Following are the technical specification and features of our Three Phase Lift Inverter - Lifton 5 KVA: Model: Lifton 05 - Rating: 5 KVA
- AC INPUT: 415 V + 15% -20% Three Phase Input
- Frequency: 50Hz ± 6%
- DC VOLTAGE: 72 V / 96 V / 180 VDC
- Charging Time: 12 Hours for 90% of full Capacity
- Charger Type: CVCC Internal Controlled Rectifier type
Inverter: - Technology: IGBT Double Conversion
- Output Voltage: 400 / 415V AC Three Phase
- Frequency: 50Hz ± 0.5Hz
- Waveform: PWM Sine wave
- Harmonic Distortion: Less than 3% on Linear Load
- Inverter Efficiency: > 90%
- Power Factor: 0.8
- Overload: 105% Continuous, 300% for 60 sec
- Crest Factor: 4:1
- Phase Displacement: 1200 ± 10
- Audible Noise: Less than 45 dB at 1 Meter
General: - Dimensions (L x W x H): 740 x 350 x 800 mm
- Humidity: Max 95%, Non-condensing
Indications & Alarms: - Mains on: Indication
- Inverter on: Indication
- DC Low: Indication & Alarm
- Fault: Indication & Alarm
- Output Overload: Indication & Alarm
Change-Over:
- Electro mechanical switch; Internal for single lift, External for Multiple Lifts
- Static Switch Bi-directional optional
| | | Add to Enquiry Basket |
| | Three Phase Lift Inverter - Lifton 10 KV We provide Three Phase Lift Inverter - Lifton 10 KVA that are designed and developed using quality raw material and latest technologies. These are offered with metering using microprocessor based digital LCD meter for R, Y, B output voltages, output currents & frequency, DC voltage, battery and load percentage, last 5 backup time storage with no. of lift operation per backup. Our Three Phase Lift Inverter - Lifton 10 KVA are offered with Protections against output overload & short circuit, output under & over voltage, DC under & over voltage input under & over voltage, single phasing & phase unbalance. Our range of Three Phase Lift Inverter - Lifton 10 KVA is offered with following technical specifications and features: Model: Lifton 10 - Rating: 10 KVA
- AC INPUT: 415V + 15% -20% Three Phase Input
- Frequency: 50Hz ± 6%
- DC Voltage: 180 VDC
- Charging Time: 12 Hours for 90% of full Capacity
- Charger Type: CVCC Internal Controlled Rectifier type
Inverter: - Technology: IGBT Double Conversion
- Output Voltage: 400 / 415V AC Three Phase
- Frequency: 50Hz ± 0.5Hz
- Waveform: PWM Sine wave
- Harmonic Distortion: Less than 3% on Linear Load
- Inverter Efficiency: > 90%
- Power Factor: 0.8
- Overload: 105% Continuous, 300% for 60 sec
- Crest Factor: 4:1
- Phase Displacement: 1200 ± 10
- Audible Noise: Less than 45 dB at 1 Meter
General: - Dimensions (L x W x H): 740 x 350 x 800 mm
- Humidity: Max 95%, Non-condensing
Indications & Alarms: - Mains on: Indication
- Inverter on: Indication
- DC Low: Indication & Alarm
- Fault: Indication & Alarm
- Output Overload: Indication & Alarm
Change-Over: - Electro mechanical switch; Internal for single lift, External for Multiple Lifts
- Static Switch Bi-directional optional
| | Add to Enquiry Basket |
| Three Phase Lift Inverter - Lifton 100 KVA We offer Three Phase Lift Inverter - Lifton 100 KVA that are designed and developed using latest and advanced technology. These are offered with protections from output overload & short circuit, output under & over voltage, dc under & over voltage input under & over voltage and single phasing & phase unbalance. Our Three Phase Lift Inverter – Lifton 100 KVA is offered with metering using Microprocessor based Digital LCD Meter. This is used for R, Y, B output voltages, output currents & frequency, DC voltage, battery and load percentage and last 5 backup time storage with no. of lift operation per backup. Following are the technical specification and features of our Three Phase Lift Inverter - Lifton 100 KVA: Model: Lifton 100 - Rating: 100 KVA
- AC Input: 415V + 15% -20% Three Phase Input
- Frequency: 50Hz ± 6%
- DC Voltage: 360 VDC
- Charging Time: 12 Hours for 90% of full Capacity
- Charger Type: CVCC Internal Controlled Rectifier type
Inverter: - Technology: IGBT Double Conversion
- Output Voltage: 400 / 415V AC Three Phase
- Frequency: 50Hz ± 0.5Hz
- Waveform: PWM Sine wave
- Harmonic Distortion: Less than 3% on Linear Load
- Inverter Efficiency: > 92%
- Power Factor: 0.8
- Overload: 105% Continuous, 300% for 60 sec
- Crest Factor: 4:1
- Phase Displacement: 1200 ± 10
- Audible Noise: Less than 45 dB at 1 Meter
General: - Dimensions (L x W x H): 1200 x 600 x 1350 mm
- Operating temperature: upto 500 degree C
- Humidity: Max 95%, Non-condensing
Indications & Alarms: - Mains on: Indication
- Inverter on: Indication
- DC Low: Indication & Alarm
- Fault: Indication & Alarm
- Output Overload: Indication & Alarm
Change-Over: - Electro mechanical switch; Internal for single lift, External for Multiple Lifts
- Static Switch Bi-directional optional
| | | Add to Enquiry Basket |
|
 |