Electronic Control Equipment
At S.P.Enterprises, we ensure that our control equipment are made of excellent raw material and are thoroughly checked. Because of our such attributes we have been able to become one most preferred companies in the industry. We are engaged in following products - electrical converter, electronic stabilizer, universal data logger, universal calibrator, DC power supply, power analyzer, sensor transmitter, circular chart recorder, ampere hour controller, PID temperature controller and temperature calibration system.
|

|  |
- Electrical isolation of input & output.
- Input: 0 to 10 Volt, 4 to 20 mA
- Output: 0 to 10 Volt, 4 to 20 mA
- Single/ dual outputs
- Din rail/wall mounting model
- Supply 110 to 260 Volt AC or 24 Volt DC ( optional)
|
Features:
- Auto / Manual operation with O/p Voltage Raise & Low push buttons.
- Miniature Potto set O/p voltage.
- Separate Load on/ Load off push button
- Fully solid state & single PCB design incorporating protections, Control.
- AC - Synchronous motor coupled with variance to facilitate high rate of voltage correction.
- Silent operation, construction convenient for easy serviceability.
- Proper ventilation with Instrument cooling fan & louvera.
- Cable entry through proper gland plate.
- Castors to facilitate easy transportation.
PROTECTIONS:
- Under/Over Voltage
- Over current trip, MCB / MCCB
- Surge Suppression.
- No Distortion in waveform / No-Effect of variation in I/p Supply, load P.F. on O/p Voitage setting.
Technical Specification -
| |
Single Phase |
Three Phase |
Unit |
| Capacity |
0.5 to 30 |
5 to 1000 |
KVA |
| Input |
175-270 |
340 - 465 Volts AC |
|
| Frequency |
47 |
52 |
Hz |
| Output |
230 |
415 |
Volts AC |
| O/p Regulation |
1 |
|
% |
| O/p Vollage Adjustment |
10 Volt of O/p Voltage |
|
Volts |
| Tripping Levels |
±15% of set O/p Voltage |
|
% |
| Rate of Conrection |
35V |
70 v |
V/ Sec |
| Metering |
Digital Voltmeters Ammeter |
| Operating Temp |
0 -50 |
|
C |
| Humidity |
95 |
&n |
|  |

|

|  |
Make SUNSUI
- 4½ Digit LCD dispaly
- Portable battery & mains operated
- Source & sink for mV, mA & RTD
- Pt-100 reading directory in terms of deg C
- Typical accuracy 0.1%
Ranges:
- mV: 0 to 199.9 Load 5
- mA max. mA: 0 to 25 mA Load 500 ??? at 20mA
- RTD: -100 to 400 deg C
Battery Low Indication:
- Test facility to confirm DPM & stabilized circuit
- Light weight & with carry bag
|
- Input: 0 to 75 mV from DC shunt.
- Range: 0 - 999999 totalizer counts, 0-500
A rate
- Size: 96(w)*48(H)*120(D) in mm.
96(W)*96(H)*120(D) in mm.
|  |

|

|  |
Micro Processor based PID Temperature Controller: MC2538, NIC 2838 PID AutoTuning, 14bitresolution O/P :Relay, SSR Drive, 4-20 mA, 3 point alarm with 19 alarm modes, NV RAM, Self diagnosis.
Input: Universal (T/C, RTD, mA, mV,0 to 10 V)
Optional : RS 232 / 485 Port, MODBUS ASCII or MODBUS RTU protocol, 2 Patterns of 8 segments each (i.e. ramp & soak) standard type with 1 Ramp and 1 Soak available.
Free range voltage: 85 VAC to 265 VAC
Size: 48 x 96 / 96 x 96
|

|  |
MODEL NO: NHP-BC240. Battery charger FOR ENGINE START APPLICATIONS 24V-10 AMPERES SUITABLE FOR CHARGING 24VOLTS 100/130/180AH BATTERIES - Input voltage : 170-270vac
- output Voltage :
- Float Mode: 26.2 V DC.
- Boost mode: 27.4 to 28 V DC
- Inrush Current: Limited by NTC thermister
- Charging current in boost mode: 10 amps
- Charging current in float mode: 0 to 3.5 amps
- Operating Temperature: 0 TO 50 DEG C
- Leakage current: <2 mA at 230 vac
- Vibration: 10-500 Hz 2G 10 min/1cycle 60 mins each along XYZ axis
- Protections:
- Input under voltage – cutoff level 140 VAC. Turn on voltage 160 VAC
- Input over voltage – 300 V AC units shuts off if voltage goes above this value
- Output over voltage ( Batt Charger included) – 29.5 V DC
- Output short circuit and overload – continuously protected
- Battery reverse polarity – protected both on line and off line
- Current drawn by charger from battery: Draws zero current from the battery under any circumstances
- Externally Induced Over voltage: Protected against output overvoltage caused by parallel connection of alternator etc
- Annunciation: Potential free NO /NC contact for charger On/ Fail indication
- Indication: Mains On, Float, Boost, and Battery Reverse
- Line Regulation: <1%
- Load regulation: <1%
- Ripple and noise: 150 mv p-p
- Input & Output: 2000V AC
- Input & Earth: 1500V AC
- Output & Earth: 1500V AC
- Dimensions: L*B*H - 190*155*75mm
- Mounting: Wall mounting type
- Weight: 1500gms
|  |
|
|
|