Our organization is involved in manufacturing and exporting a wide range of Radiant Warmers. These are elegantly designed and attached with I.V stand. To monitor the reaction of the babies it can be easily attached to the PC using RS-232 Connector. In this product the electronic humidity and oxygen are perfectly controlled by the effective control system. We can find its application widely in the maternity sections.
|
 
| | Infant Radiant WarmerSST range of TIANA warmers allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures .Immediately after birth the new born baby experiences some degree of thermal instability as it comes from the mother’s womb which has stable environment , to the cooler environment of the delivery room, Tiana range of warmers promise error free , comfortable and secure treatment of the new born. Control Panel: - SST Infant Warmers are designed to provide advance warming capabilities while using one touch operations to simplify procedures.
- Advance microprocessor controlled system with self check on the electronic circuitry skin / air / manual control.
- Digital display of baby temperature / air temperature . Soft touch display of control temperature.
- Manual / servo two function control modes provide the clinician more flexibility while optimizing the thermal environment.
- In addition the skin / Air temperature is larger than the other set temperature display.
- Skin temperature can be converted from degree C to degree F by the push of a button.
Baby Bed: - Fixed
- The spacious baby bed incorporates easily drop down sides for maximum access to the patient.
- Soft cushion mattress for the comfort of the little patient.
Alarms: The control panel is also the heart of the system for a completely integrated alarm system with both audible and visual indicators in the event of probe fail: - Skin high
- Skin low
- Power fail
- Heater fail
Manual Mode: - Facility to converting the warmer from servo mode to manual mode for non-stop working.
- In Manual mode warmer will start from 40% heat and can be increased upto 99% according to usage.
Heater Assembly: - The heater assembly located above the center of the support structure consists of radiant heater and reflector with inbuilt halogen examination lamp for assessment of infant color .
- Reflector : stainless steel.
- CE marked German make ceramic 650 watts heater or quartz crystal heater available as per the choice of the customer .
- Heater can be swiveled for Xray procedures.
Supplementary Attachments: - Lower Shelves.
- Three Drawer system to store consumables.
- Side tray.
- Pole for Syringe Pump or Infusion Pump.
- Stainless steel IV stand.
Halogen Bulb: - 12VOLTS ,50 WATT
- Bright light for the proper assessment of the new born infant.
- The Model Does Not Come With LCD And Apgar Timer.
Technical Specification: Electrical Specification: - Power supply 200V/50Htz
- Heater Power 650Watts
- Fuse 5 Amp
|
 
| | Open Care SystemSST range of TIANA warmers allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures .Immediately after birth the new born baby experiences some degree of thermal instability as it comes from the mother’s womb which has stable environment , to the cooler environment of the delivery room Tiana range of warmers promise error free , comfortable and secure treatment of the new born .
Control Panel: - A big LCD is provided for more specific information and visualization of the heater power in manual and servo modes .
- SST Infant Warmers are designed to provide advance warming capabilities while using one touch operations to simplify procedures.
- Advance microprocessor controlled system with self check on the electronic circuitry skin / air / manual control.
- Digital display of baby temperature / air temperature . Soft touch display of control temperature .
- Manual / servo two function control modes provide the clinician more flexibility while optimizing the thermal environment .
- In addition the skin / Air temperature is larger than the other set temperature display .
- Skin temperature can be converted from degree C to degree F by the push of a button.
Baby Bed: - Fixed.
- The spacious baby bed incorporates easily drop down sides for maximum access to the patient.
- Soft cushion mattress for the comfort of the little patient .
Alarms : The control panel is also the heart of the system for a completely integrated alarm system with both audible and visual indicators in the event of : - Probe fail
- Skin high
- Skin low
- Power fail
- Heater fail
Manual Mode: - The heater assembly located above the center of the support structure consists of radiant heater and reflector with inbuilt halogen examination lamp for assessment of infant color .
- Reflector : stainless steel
- CE marked German make ceramic 650 watts heater or quartz crystal heater available as per the choice of the customer .
- Heater can be swiveled for X ray procedures .
Supplementary Attachments :
- Lower Shelves
- Three Drawer system to store consumables
- Side tray
- Pole for Syringe Pump or Infusion Pump
- Stainless steel IV stand
Halogen Bulb: - 12volts ,50 Watt
- Bright light for the proper assessment of the new born infant .
- The Model Does Not Come With LCD , Apgar Timer And Baby Bassinet.
Technical Specification: Electrical Specification: - Power supply 200V/50Htz
- Heater Power 650Watts
- Fuse 5 Amp
|
 
| | Microprocessor Based Controller - The digital, microprocessor-based controller comes standard with a full spectrum of features.
- The Tiana Open care System comes complete with automatic manual and baby (Servo) modes.
- Two function control models provide the clinician more flexibility while optimizing the thermal environment.
- Skin temperature display is larger then other set temperature display
- Skin temperature display can be converted from °C to °F by the push of a buttom.
- A full complement of alarm provides safety and convenience, with both audible and visual indicators in the event of:
High Temp. / Low Temp. :
- Set High / Set Low
- Probe Failure
- Power Failure
- The system automatically starts the heating from 40% in manual mode and the same can be changed through settings upto 99%.
- The High & Low temp. alarm settings can be adjusted according to the patient condition.
- The Radiant Warmer features an independent ambient temperature probe which maximizes the heating efficiency across the range of operating temperature.
- A big LCD is provided for more specific information & visualization of the heater power in manual and servo modes.
- The system automatically converts from servo mode to manual mode in case of probe failure thus providing non stop working of the unit.
- The spacious baby bed incorporates easily drop down sided for maximum access to the patient
Heater Assembly: The heater assembly located above the center of the support structure consists of an integral examination light and a 650 Watts heating system for quick warming and even distribution of heat on the baby bed. The First Breath:
- The open care system combines virtually all the technologies, which a caregiver may need for resuscitation.
- The neonate can be supplied with a constant oxygen flow through the oxygen humidifier when connected to an oxygen cylinder (optional).
- The motorized slow suction can be used with a simple flip of a switch
- A digital apgar timer is standard, which signals when 1, 5 and 10 minutes have collapsed.
Technical Specification: - Height 1924mm
- Length 884mm
- Width 858mm
Electrical Specification: - Power supply 200V/50Htz
- Heater Power 650Watts
- Fuse 5 Amp
- IEC COMPLIANT
|
 
| | Restohealth Microprocessor ControllerWhat is restohealth: restohealth is a unique system that can deliver high flows of air or oxygen ranging from 1 to 15 lpm. Clinical studies have proven the usefulness of high flow of gases when warmed at body temperature and humidified up to 99 to 100% relative humidity and delivered through nasal cannula. importance of heat and humidity :
- heat and humidity prevents airway water loss, airway cooling, thickened secretions, nasal irritation & bleeding.
- before restohealth bubble humidifiers were used to deliver high humidity in above applications.
- the restohealth allows delivery of breathing gases heated to body temperature & at nearly 100% relative humidity by nasal cannula without drying or cooling the airways, which was not possible in the conventional bubble humidifiers.
advantages of restohealth:
- the gas delivered by restohealth contains up to 55 mg/h2o per liter (depending upon the temperature setting). Clinical studies have proven that high water vapour is effective in mobilizing thickened airway secretions.
- breathing warm & humidified gases from restohealth is an effective method of core rewarming especially post surgery or after cold exposure.
- warm humid gases have been found to inhibit the nasal response to allergy. Water vapour at 410 c is as effective as aerosol therapy in reducing allergic rhinitis symptoms.
- restohealth can deliver high flows of warm & humid gases via nasal cannula which greatly improves patient’s comfort as compared to gases delivered via face mask.
- the effect of heat & humidity optimize the use of nasal cannula thus helps the practitioner to use higher flows which other wise is not possible.
- provides the user to use higher flows without adverse effects & patient’s discomfort that includes nasal drying, bleeding & septal breakdown.
- higher flow provides numerous clinical advantages.
- in nicu, using restohealth helps the doctor to easily feed, hold & care of patient which otherwise would not be possible due to interference.
|
 
| | Radiant WarmerTiana–D comes covered with ABS moulded plastic cover featuring an independent ambient temperature probe which maximizes the heating efficiency across the range of operating temperatures .