Water Cooled Liquid Chiller
 |
|
 |
We are manufacturing and supplying technically advanced water Cooled Liquid Chillers and air cooled liquid chillers which ensure accurate temperature controlling. These have hermetic reciprocating compressors and can provided with environmentally friendly gas (r134a, r407c etc.) on request. The features are as follows: - Ready to install
- Low power consumption
- Low maintenance cost
- Scroll compressors (optional)
- In built pump & stainless steel tank (min.250 ltrs)
- Castor wheels (optional)
These have following kinds of alarms:
- HP / LP
- Antifreeze
- Compressor & pump overload tank
- Water level
- Single phase
- Low water flow control
- Chilled water inlet temperature
- Chilled water outlet temperature
- Condenser inlet temperature
- Condenser outlet temperature
The specifications are as follows: | Model | Flow Rate LPM | Cooling Capacity | | Connected Power | Refrigerant | Dimensions | | | Chiller In/Out connections | Weight | | | | TR | KW | (kw) | | L | W | H | (mm) | (Kgs.) | | SCW-60 | 60 | 6 | 21 | 13 | R-22 | 2000 | 1100 | 1350 | 40 | 400 | | SCW-70 | 75 | 7.5 | 26 | 14 | R-22 | 2200 | 1200 | 1400 | 40 | 450 |
 | |  |
|
|
 |
|
 |
 |
Packed Liquid Chiller
We are offering to our clients, packed liquid chillers and air cooled liquid chillers which have generously sized air cooled condensers. Equipped with in built pump & stainless steel tank, these can be provided with environmentally friendly gas { r134a, r407c etc, ) on request. The salient features are as follows: - Easy to install
- Lowest power consumption
- Environmental friendly
- Low maintenance cost
- Accurate temperature controlling
- Hermetic compressors.
- Electronic temperature controller.
- Mains isolator.
- Castor wheels (optional).
The specifications are as follows:
| Model | Flow Rate LPM | Cooling Capacity | | Connected Power | Refrigerant | Dimensions | | | Chiller In/Out connections | Weight | | | | TR | KW | (kw) | | L | W | H | (mm) | (Kgs.) | | SCA-5 | 5 | 0.50 | 1.75 | 1.50 | R-22 | 650 | 720 | 1070 | 20 | 110 | | SCA-7 | 7 | 0.75 | 2.63 | 2.00 | R-22 | 650 | 720 | 1070 | 20 | 125 | | SCA-10 | 10 | 1.00 | 3.52 | 2.00 | R-22 | 850 | 720 | 1200 | 20 | 145 |
|
|
 |
|
 |
 |
Copper Chiller
 |
|
 |
We are engaged in manufacturing and supplying of copper chillers which are widely used in various industries like chemicals, pharmaceuticals, plastic and others. These are provided to our clients in the range of 1 to 125 TR and in multiples. Apart from these, we also market absorption and Centrifugal Chillers. Chiller packages from I to 40 TR are also offered In the Air cooled range. Brine units for minus temperatures are supplied mostly with open type compressors. These chillers are required whenever water is required at a temperature lower than 28 Deg.C. Our copper chillers have three circuits: Refrigeration Circuit: - The Freon Compressor, compresses the freon which is cooled in the condenser to form liquid, and sent through the Expansion valve in the chiller
- In the chiller the liquid freon takes away the heat from process return water and cools it and in turn evaporates to gas which is returned back to the Freon compressor and compressed.
Chilled Water Circuit: - Chilled water from the outlet of the chiller goes to the cold section of the hot well / cold well tank from where it is pumped by the secondary pump to the process machines where it picks up heat
- Hot water from the machine goes to hot section of hotwell/cold well rank which is again pumped by the primary pump to the chiller where it gets cooled and the cycle continues
- Some times the hot well/coldwell tank is not required and direct water is sent to the
- machine by a single pump which returns back to a mixing tank
Cooling water circuit: - Cooling water is pumped from the cooling tower to the condenser where freon is condensed due to the cooling effect by the condenser water which in turn gets heated and which is further cooled in the cooling tower and re-circulated
 | |  |
|
|
 |
|
 |
 |
Cooler Parts
 |
|
 |
We are offering to our clients various cooler parts that are manufactured as per the industrial standards. Our range of cooler parts includes Air cooled Condensers, Expansion waive, Chillers, Open Type Compressor Starter Panel, Hermetic Compressor, Water cooled condensers and motors. These parts are appreciated all over for their high efficiency and durability. The salient features of each part are given below:
Air-cooled Condensers: - Low Speed Condenser fan
- Low noise level
- Easy maintenance
- Low power consumption
- Buffer CFM capacity
- Compact and high efficiency tans
- Large Heat transfer area
- Better efficiency with special copper tubes.
Expansion waive: - Imported Sporlan / Alco make which controls Flow of freon Liquid to the chiller Constant refrigerant pressure for a stable chilled water temp, on full load condition is obtained by this unique refrigerant pressure, regulated expansion valve.
Motor: - IP-54, TEFC/ SPDP fan motor
- 4 Pole
- 1500 RPM
Open Type Compressor: - Automatic Capacity Control saves power stepping down compressor capacity. Positive Pressure Lubrication uses an over sized, manually reversible pump lo assure proper oiling of bearings and wear surfaces plus oil circulation in shall seal Chamber.
Hermetic Compressor: - Rugged Design
- Quiet Operation
- Phase 50 Hz, a1 2900 RPM
- Highest Reliability
- Internal Suspensions
- Oil level test
- Internal, Solid State self regulating crank case heater
- Better Liquid handling capacity
- Wide operating range
Water cooled condensers: - Non-ferrous tubes with integral fins provide exceptionally high heat transfer rates, it derives super efficiency from enhanced copper tubes geometry
- Bell mouths on tubes give very low water pressure drops.
- Large refrigerant storage capacity allows condensers to serve as a reservoir for holding liquid refrigerant when system is not in operation
- Tubes are pneumatically expanded into tube sheets thus permitting easy replacement from either ends
- Designed for refrigerant 22, 500, 502,134-A
Chillers: - Engineering in single, dual refrigerant circuit designs for different load conditions
- Specially designed finned tubing delivers superior heat exchange
- Internal battles, contoured and spaced to deliver optimum water turbulence and flow patterns
- Removable heads facilitating service.
- Mounting brackets and lifting lug are standard features.
- Cooling liquids other than water also feasible
- Suitable for Refrigerant 22, 500, 502 134A and other environmental friendly refrigerant.
- Efficient accumulator avoids risk of liquid refrigerant entering into the compressor
- Tank with SS internal and sturdy MS structure
- Specially designed primary pumps lo circulate chilled water from chiller to process.
Starter Panel: - Mounts starters for main motor, chilled water and condenser water pumps (also standbys) in this panel
- Sequential interlocking to ensure safe operation and proprietary system design with special instrumentation to safeguard all essential parts
 | |  |
|
|
 |
|
 |
 |
Annunciation Panel
We are engaged in manufacturing and supplying of various annunciation panels which are widely appreciated by our esteemed clients. These especially designed panels are provided to our clients with indicating lights and alarm. The specifications are as follows: | Device 1) High Pressure Cutout 2) Low Pressure Cutout 3) Oil Pressure Switch 4) Antifreeze Thermostat 5) Cooling Tower Pressure 6) Unloading Solenoid 7) Overload Relays | Function Trips compressor in case of excessive discharge pressure. Trips compressor in case of low suction pressure. Trips compressor in case of low oil pressure. Has to be reset after 45 sec. manually. Trips compressors in case of too low chilled water temperature. Trips compressor in case of low cooling water pressure. Preventing compressor from running on full capacity during starting, and thus avoids overloading of motor. Trips the compressor/pump when overloaded. |
|
|
 |
|
 |
 |
Special Engineering Services
 |
|
 |
We offer to our clients, special engineering services which are directed towards solving chilled water problems. Our professionals survey client’s needs and recommend the proper chilled and Condenser water piping system for maximum efficiency. We suggest our clients on the tonnage of the chilling plant required for their machines / Reactor Vessels, actual temperature to be maintained at exact pressures to be developed considering the pressure drops and line losses. Our services are meant for: Sizing of:
- Cooling Tower
- Secondary and Primary pumps
- Mixing Tank
- Heater. Energy savings
- Condenser and chilled water piping
Field Service:
- Our highly trained professionals provide our clients with preventive maintenance to meet any emergencies
Spare Parts:
- We have with us a large stock of genuine spare parts for equipment which avoids any possible costly delays
- The substitution by interior parts result in keeping old machines in good-as-new condition
Complete Repair Service:
- We can also repair or overhaul compressors by factory recommended methods by using only genuine parts
Complete Stock of Equipment:
- We have a complete stock of machines which can usually take care of any need is backed up by SUPERCHILLERS prompt factory shipment to assure time delivery
 | |  |
|
|
 |
|
 |