LV SwitchGear Assembles
Automatic Mains Failure Panels (AMF) Assembly : Fixed / Draw-out Installation : Indoor / Outdoor Current rating : Upto 5000A Incomer device: : ACB / MCCB / CONTACTOR Outgoing : ACB / MCCB / SFU Other specs. : PLC Operator I Conventional Relay type Metering : A, V, KW, Kwh, KVAh, PF, Hz, Kwh meter Etc as per request. Optional : Battery charger with metering cabinet. Busbars : High Conductivity hard drawn copper bars. Tinned and with colour coded fire retardand sleeves. Enclosure : E.G sheet steel, Power coated to RAL 7032 1.5/ 2mm thick. (otherspecs. On request)
Your enquiry has been sent
Processing...
Automatic Power Factor Control Panel Assembly : Fixed Installation : Indoor Current rating : Upto 1000KVAr Incomer device: : ISOLATOR Outgoing : Capacitor banks backed up by HRC fuses controlled by microprocessor relay with capacitor duty contactors, NumberofCkts : upto 14 Busbars : Highcor,duccr w7) hard drawncopperbars. Tinned al"'d w',;t.h co c codedfire retardantsleeves. Enclosure : E.G sheet steel, Power coated to RAL 7032 1.5/ 2mm thick. (otherspecs. On request)
Your enquiry has been sent
Processing...
Metering Panels Assembly : Fixed Installation : Indoor Current rating : Upto2000A, 65kAfor 1 Sec Incomer device: : ACB / MCCB / SFU /ISOLATOR Outgoing : SFU/ MCCBthrough meter& cutout Metering : A, V, KW, Kwh, KVAh, PF, Hz etc As per request. Busbars : High conductivity hard drawn copper bars. Tinned and with colour coded fire retardant sleeves. Enclosure : E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specs. On request)
Your enquiry has been sent
Processing...
Motor Control Centers (MCC) Assembly : Fixed / Draw-out Installation : Indoor Current rating : Upto 5000A, 75kA for 1 Sec Incomer device: : ACB / MCCB / SFU /ISOLATOR Outgoing : ACB / MCCB / SFU Metering : A, V, KW, Kwh, KVAh, PF, Hz etc As per request. Busbars : High conductivity hard drawn copper bars. Tinned and with colour coded fire retardant sleeves. Enclosure : E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specs. On request)
Your enquiry has been sent
Processing...
Power Control Centers (PCC) Assembly : Fixed / Draw-out Installation : Indoor / Outdoor Current rating : Upto 5000A, 75kA for 1 Sec Incomer device: : ACB / MCCB / SFU /ISOLATOR Outgoing : ACB / MCCB / SFU Metering : A, V, KW, Kwh, KVAh, PF, Hz etc As per request. Busbars : High conductivity hard drawn copper bars. Tinned and with colour coded fire retardant sleeves. Enclosure : E.G sheet steel, powder coated to RAL 7032 1.5/ 2mm thick. (Other specs. On request)
Your enquiry has been sent
Processing...