We specialize in offering an all-inclusive range of Synchronizing Relay. Our user friendly and easy to keep up Synchronizing Relays can be expanded as per the requirements due to their flexibility. Our Synchronizing Relays are integral with electrical governor system with the differences in voltage, frequency and phase angle set between grid and genset.



Load Balance Relay

Load Balance Relay

Load balance relays are used to balance sharing between two generators. The Master genset power consumed is measured and compared to the follower power consumed. Relay generated a raise speed signal when lost in follower is lower than master and similarly the lower speed signal when follower load is higher than master.


Center Frequency Relay Te 742

Center Frequency Relay Te 742

Teknika center frequency relay is used for matching frequency of 50 Hz. A preset 50 Hz is compared to incoming frequency and a high or a low signal is generated. The pulsed high or low signal can be used to increase or decrease the frequency of the generator. Frequency matching indication and raise lower indications are also available.


Frequency Balance Relay

Frequency Balance Relay

Teknika Frequency Balance relay is used for matching frequency of two generators and generating a high or low signal. The pulsed high or low signal can be used to increase or decrease the frequency of the generator. Frequency matching indication and raise lower signals are also available.


Check Synchronizing Relay

Check Synchronizing Relay

Teknika check synchronizing relay is used for manually paralleling of gensets by matching voltage, frequency and phase angle. Zero crossover can be detected manually. Check sync relay gives a breaker close indication.

Generator breakers are to be closed manually.



Auto Synchronizer Relay

Auto Synchronizer Relay

Teknika autosynchronizer relay is used for paralleling of gensets by matching voltage, frequency, phase angle and zero crossover, internal settings for speed of closure (fst, medium, slow) and breaker close timings. Relay gives a breaker close signal and locks itself out preventing further commands. Raise / lower signals for frequency and voltage can be used to increase / decrease genset speed and AVR output voltage. Upto four generators can be synchronized by building control logic to synchronize generators one by one.






 

Contact Us

Teknika Electronics
Deepak Sharma (Director)
A- 39, FF Complex, Okhla Estate
Delhi - 110020, India

Contact via E-mail

Contact via SMS


Home|Profile|Our Product Range|Site Navigation|Contact Us
Member IndiaMART.com © Teknika Electronics. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited