IndiaMART.com
Company Directory  > Scientific Instruments & Supplies  > Testing Equipment & Machines  >
Share:

Telecom Consultants & Construction Co.

New Delhi, Delhi

Year of Establishment: 1987
IndiaMART Member Since: 2006
Products [63], Latest Offers [8]
Phone: +(91)-(11)-64627691

HOME

ABOUT US

PRODUCTS & SERVICES

LATEST OFFERS

CONTACT US

SEND ENQUIRY


Products & Services

Advance Line Detector (1)

Automatic Line Tester (1)

Cable Burn Down Instrument (1)

Cable Fault Locator (6)

Cable Identification Instrument (1)

Cable Route Tracer (2)

Civil Construction Work (2)

Digital Storage Osciloscope (2)

Exchange Parameter Monitor (1)

Gepon Products (3)

Insulation Tester, Earth Resistance Tester, Arc Reflaction Filter Model (3)

Intelligent Line Tester With LCD Display (1)

Intelligent Telephone Analyser (1)

Line Phase Detector (1)

Our Products (21)

Portable Line Tester (1)

Sheath Fault Locator (1)

Surge Wave Receiver (1)

Surge Wave Tester (2)

Telecom Services (9)

Telephone Analyser (1)

Water Leak Detector (1)


About Us


Sitemap

Our Products

Our product range includes :


33/4a Digital Multimeter Vc97

33/4a Digital Multimeter Vc97

Features :

Streamline Holster Design.

Large LCD Display for Clear Reading.

Metallic Screen Board with Stronger Antimagnetic and Antiinterference from External E/M Field.

Full Function Protection, Anti-high Voltage Circuit Design.

Auto power off.

New type battery case design. It's easy to change battery.

 

TECHNICAL SPECIFICATIONS

DC Voltage

400mV / 4V / 40V / 400V / 1000V (±0.5%).

AC Voltage

400mV / 4V / 40V / 400V / 750V (±0.5%).

Resistance

400Q / 4kQ / 40kQ / 400kQ / 4MQ / 40MQ (±1.0%).

Capacitance

4nF / 40nF / 400nF / 4uF / 40uF / 200uF( ±2.5%).

Frequency

100 / 1000 / 10k / 100k / 1M / 30MHz (±0.5%).

Temperature

-40°C to 1000°C ±(0.8% +4).

Special Functions

Diode Test.

Transistor Test.

Continuity Buzzer.

Low Battery Indication.

Auto Power Off.

Function Protection.

Shock Proof Protection.

Relative value measurment.

Frequency / Duty Cycle measuring -0.1 - 99.9%.

Input Impedance

10M.

Sampling Rate

3 times/s.

AC Frequency Response

40 - 400 Hz.

Operation Way

Auto Range.

Max. Display

3999.

LCD size

65 x 35 mm.

Weight

320g. Approx. (including battery).

Dimension

190 x 88.5 x 27.5 mm.

Standard Accessories

Test Leads, Instruction Manual, TP01 Temperature, Probe (vc97).

 

 


 
 

Advance Line Detector Model

Advance line Detector Model
First time in India the UNIQUE ADVANCE LINE DETECTOR ( model TCC - 2008 ) has been specially designed by  System the location of fault of multipair underground cable on single button click it display the result on the fault in meters on 16 digit LCD Display with crystal base Accuracy of ± 1% and operate on built in rechargeable batteries. It is very Portable, light weight and user friendly to field start working.

 
 

Automatic Line Tester

Automatic Line Tester
Specifications

Test automatically one by one all parameters of sub's line from MDF.
Tests, Compares & then display's exact condition of the line by GO/ON-GO LED.
Digital Display of
(a) Foreign Potential (AC/DC)
(b) Cross Insulation
(c) Leak of earth (A to E & B to E)
(d) Line Capacitance
(f) Loop Resistance
Simultaneous Digital display of
(a) Dial Speed in IPS
(b) Dial ratio in %
(c) Digit Count
New Line tone test
GO/ON-GO TEST facility
Tests all types of push button telephones both pulse and DTMF types
Ring and Speech test
Rugged Compact and Moulded ABS body
Easy Operation and Minimal controls.

Parameter Range GO/ON-GO Limits
Foreign Potential (AC/DC) 0-99 Volts > 10 Volts NO-GO
Insulation Resistance with  respect to earth 0 - 2.5 Ohm  (in Two range) > 1 M Ohm GO
Cross Insulation 0 - 2.5 M Ohm > 1 M Ohm GO
Line Capacitance 0 - 9.9 MFD 0.5 - 5.0 MFD GO
Loop Resistance (With push button telephone) 0 - 2.5 Ohm > 1200 Ohm - Go
Dial Speed M-B Ratio 3-30 IPS 10-90% 9-11 IPS GO 60-72% GO
New Line Tone 1000 Hx + 5%  
Operating Voltage Ringing AC 230 V 5%, 50 Hz,  5 watt, 75 Vrms, 50 Hz  
Operating Temp Humidity 0-50 Degree C 20 - 80% w/o condensation  
Weight Dimension 3 Kg. 22 (L) x 23 (W) x 11.5 (H) cms  
Accessories Pair of Test leads,  Operation manual  



 
 

Cable Drums

Cable Drums

Cable Drums

LOCOMP

HV Output cable: 6 sq mm co-axial flexible, 6 kV DC

Mains cable: 1.5 sq. mm 250 V AC, 3 Core PVC Flexible cable

Earth cable: 10 sq. mm single core PVC Flexible cable

Note : Cable drums can be supplied as per customer requirement


 
 

Digital Intelligent Broad Brand Line Tester

Digital Intelligent Broad Brand Line Tester
Digital Intelligent  Broad Brand Line Tester HTS-20010

Automatic Test It test a line completely even in the presence of foreign potential up to 10 volts.
Testing Time It test automatically one by one all line parameters within 10 seconds only
New Line Tone Test It provides 800 c/s +/- 10% tone for both pair Identification
Display of results It display results on 16 characters LCD display with built-in intelligence.
Measurement range of Line Parameters It test & displays on LCD extra value of Foreign potential (AC/DC) upto100 V Cross Insulation up to 3 M ohms Leak to earth upto3 M ohms Line capacitance up to 9.9 MFD Loop resistance upto3 K ohms
Dial Test It test & displays all the digits dialed from both tone & Pulse telephones
Ring & Speech Test It provide for ring & Speech test.
 Controls & Keys  Only soft keys are used to eliminate mechanical features
 Ringing  75V rms, 50 Hz
 Operating Voltage AC 230 V+/- 5%, 50 Hz, 5 Watt
Weight  3 Kg. Approx
Accessories Pair of test lead, operation manual  
It takes only 10 seconds to test a line even with foreign potential up to 10 volts & displays test results intelligently on LCD display
It comes with one year free comprehensive maintenance
Replacement of cards and spare parts only.

 
 

HT Cable Fault Locating System

HT Cable Fault Locating System

Reliable and cost-effective instrument for pre-location & pin-pointing cable faults

HICOMP 16 compact module comprises of minimum configuration of high voltage cable fault locating instruments, mounted on a robust trolley.

 

The system offers the following:

 

Portable cable fault locator: for pre-location of bault distance using TDR method HV surge tester for pinpoint location of flash over faults Surge Receiver with ground microphone: for pinpointing fault by acoustic method Insulation tester for IR measurement of the cable under test

HV, mains supply and earth cable drums Storage cabinet

 

High Voltage Surge Tester SWT 16

HICOMP

Specifications

Power Supply

230VAC + 10% 50 Hz

Output Ranges

0-4,8,16kV

Energy Output

500 Joules at each Range (Optional 1000Joules)

Indication

Analog Moving Coil Meter for kV Indication

Protection

1) Variac Zero inter Lock

 

2) Out put Plug inter Lock

 

3) HV Switch inter Lock

 

4) Over Heat Protection

Impulse sequence

Single impulse, 1.5,3, or6Second Intervals

Dimensions

450 (L)x310(W)x580 (H)mm

Weight

57Kg

 


 
 

HV Surge Tester Fault Locating Instrument

HV Surge Tester Fault Locating Instrument

Reliable and cost-effective instrument for pre-location & pin-pointing cable faults

Occurrence of cable fault can not be avoided due to many factors. Long outage of a cable from service results in heavy loss of revenue to the power distribution company production loss to industries as well as unpleasant condition to general public.

 

Pre-location

SWT 32 has built-in current coupler that can be used to get the fault distance measurement carried out on a suitable TDR on Impulse Current Mode. It can also be coupled to other instrument compliments such as Arc Reflection Filter to get reliable results of the fault distance.

 

Pin-Point Location

Surges of high energy are applied to the fault at the set voltage and time interval for pin-pointing the exact spot on the cable length.

 

Single Impulse and repetitive surges

The instrument has single impulse mode, by which a single shot of surges is applied to the fault for ascertaining the level off ault breaking.

This mode is also necessary for pre-location tests to be carried out with other instrument compliments. Repetitive timings of 1.5, 3 and 6 second intervals are suitable for pin-pointing the fault.

 

Safety controls

SWT 32 employs safety controls for personnel and instrument safety. Variac zero, HV switch interlock, output cable plug interlock, instant earth discharge of internal capacitor bank and the cable under test at the time of switching off/tripping offer absolutely safe operational condition.

 

Customer service

All instruments have been designed based on safety, capability, field application, ruggedness and ease of operations. We try to offer the best possible solutions for the job.

 

Specifications

SWT 32

Power Supply

220/240VAC + 10% 50/60 Hz

Output Ranges

0-8,16,32 kV

Energy Output

1000 Joules (Optional 2000Joules) Full Energy at each Range

Impulse Sequence

Single Impulse, 1.5,3,6 Sec. Intervals

Indication

Analog Moving Coil Meter for kV Indication

Protection

1) Variac Zero inter Lock

 

2) Output Plug inter Lock

Dimensions

540 (L) x 435 (W) x 750 (H) mm incl. Caster wheels

 

Receiver to be used with Surge Tester

Surge Wave Receiver SLE 90 with Ground Microphone & Headphone

 

 

 


 
 

High Precision Lcr Meter

High Precision Lcr Meter
Aplab High Precision LCR Meter Models 4100 and 4200 are high class digital LCR meter for applications in component measurements, in R&D and in production activities. A large 240 x 120 dot matrix LCD with back light is used for better contrast and visibility. Measurements are always accompanied with supplement factors such as R/Q, C/D, C/R & L/Q. 100 sets of measurement set up memory allow sharing of multiple testing conditions. Windows based proprietary software is provided optionally for PC communication through RS232C Interface.

Features
  • Test Frequency : 12Hz ~ 200KHz.
  • Continuously Variable Frequencies.
  • 0.05% High Measurement Accuracy.
  • 100 Sets Memory for Save / Recall of Settings.
  • R/Q, C/D, C/R, L/Q Test Modes.
  • Absolute value, DValue and D%Measurement Display.
  • 240 x 128 dot Matrix LCD Display.
  • Simultaneously Display Test Condition and Test Result
  • Optional Interface : RS-232C (Including LCRViewer Software..
Technical Specifications

Blank
MODELS 4100 4200
TEST FREQUENCY 12Hz to100kHz (503 steps). 12Hz to 200KHz (504 steps).
BASIC ACCURACY

R, L, C, Z 0.05% (Basic). 0.05% (Basic).
D, Q 0.0005 (Basic). 0.0005 (Basic).
Ø 0.03º. 0.03º.
TEST SPEEDS Slow 896 msec, Medium 286 msec, Fast 135 msec.
TEST SIGNAL LEVELS 5mV to 1.275V at 200KHz > 100mV
DC BIAS Int. 2V, Ext. 30V DC, <200mA.
MEASUREMENT PARAMETERS Ls/Lp, Cs/Cp, Rs/Rp, D, Q, ESR, EPR, Z, Ø.
MEASUREMENT MODES R/Q, C/D, C/R, L/Q, Z/Ø, L/R.
DISPLAY RANGE
PRIMARY DISPLAY
Inductance (L) 0.00001 mH - 99999 H.
Capacitance (C) 0.00001 pF - 99995 µF.
Resistance (R) 0.00001 W - 99999 K
Absolute Impedance (Z) 0.00001 W - 99999 KW.
SECONDARY DISPLAY (4 Digits)
Dissipation Factor (D) (with C) 0.0001 - 9999.
Quality Factor (Q) (with L or R) 0.0001 - 9999.
Ø (Phase Angle of Impedance) 180ºC to ±180ºC.
ESR 0.0001? - 9999K
EPR 0.001? - 9999K
Interface Standard RS232C.
D (in ppm) (with C) 1 ppm - 9999 ppm.
Q (in ppm) (with L or R) 1 ppm - 9999 ppm.
MEASUREMENT DISPLAY Value, D% & D.
A% 0.00001% - 99999%.
EQUIVALENT CIRCUIT



 
 

High Voltage Test Instruments

High Voltage Test Instruments

High Voltage Test Instruments

Reliable and cost effective instrument for high pressure testing

 

Features

HVG

Easy to perform HIPOT test.

Comprehensive safety features.

Continuously adjustable output voltage.

Selectable current ranges.

Built in auto discharge in case of mains power failure or instrument switch off.

Timer provision to switch off the instrument automatically after the preset period.

 

Application

HVG

FUNCTION

Dielectric testing of cables and installations with DC or AC / DC (optionally).

Pre-location of faults having high resistance nature, by using Voltage transient / decay method.

 

OPERATION

Connect the cable / device to HV test instrument with all safety precautions, especially reliable safety earth connection.

Increase the output voltage gradually to avoid heavy in rush current to the cable / Device under test.

Maintain the prescribed voltage for given period of time. The leakage current indication will give the dielectric strength of the insulation.

Apply AC Voltage to specifically advised devices only such as bus-bar insulators etc.

High pot testers are successfully used for pre-locating high resistance faults where surge / arc reflection methods fail to give results. This method is know as voltage coupler / Decay method.


 
 

Intelligent Line Tester

Intelligent Line Tester

Automatic Test It test a line completely even in the presence of foreign potential upto 10 volts.

Testing Time It test automatically one by one all line parameters within 10 seconds only.

New Line Tone Test It provides 800 c/s +/- 10% tone for both pair Identification.

Display of results It display results on 16 characters LCD display with built-in intelligence.

Complete testing of Sub's Line & Telephone from MDF.

It takes only 10 seconds to test a line even with foreign potential upto 10 volts & displays test results intelligently on LCD display.

It comes with one year free comprehensive maintenance.

Ideally suitable for medium to large telephone exchanges.

Ring & Speech Test

 

It provide for ring & Speech test.

Controls & Keys 

 

Only soft keys areused to eliminate meachanical reatures.

Ringing 

 

75V rms, 50 Hz

Operating Voltage

 

AC 230 V+/- 5%, 50 Hz, 5 Watt

Weight 

 

3 Kg. Approx

Dimentions

 

25 (L) x 26 (B) x 15 (H) cms

Accessories

 

Pair of test lead, operation mannual

 

Features

Complete testing of Sub's Line & Telephone from MDF

It takes only 10 seconds to test a line even with foreign potential upto 10 volts & displays test results intelligently on LCD display.

It comes with one year free comprehensive maintenance

 


 
 

LT Cable Fault Locating System

LT Cable Fault Locating System

Reliable and cost-effective instrument for pre-location & pin-pointing cable faults

LOCOMP compact module comprises of minimum configuration of low voltage cable fault locating instruments, mounted on a robust trolley.

The system offers the following:

 

Portable cable fault locator: for pre-location offault distance using TDR method LV surge tester for pinpoint location of flash over faults Surge Receiver with ground microphone: for pinpointing fault by acoustic method Insulation tester for IR measurement of the cable under test

 

HV, mains supply and earth cable drums Storage cabinet

 

Low Voltage Surge Tester SWT 4

LOCOMP

Specifications

Power Supply

230VAC + 10% 50 Hz

Output Ranges

0-2, 4kV

Energy Output

500 Joules at each Range

Indication

Analog Moving Coil Meter for kV Indication

Protection

1) Variac Zero inter Lock

 

2) Out put Plug inter Lock

 

3) HV Switch inter Lock

 

4) Over Heat Protection

Impulse sequence

Single impulse, 1.5,3, or 6 Second Intervals

Dimensions

450 (L)x300 (W)x455 (H)mm

Weight

44Kg

 


 
 

LV Surge Tester Fault Locating Instrument

LV Surge Tester Fault Locating Instrument

Reliable and cost-effective instrument for pre-location & pin-pointing cable faults

Occurrence of cable fault can not be avoided due to many factors. Long outage of a cable from service results in heavy loss of revenue to the power distribution company production loss to industries as well as unpleasant condition to general public.

This requires an efficient instrument capable of locating the fault in minimum possible time and restoring the supply. SWT 4 is a powerful instrument to pre-locate the fault distance and exactly locate the fault point in a short time. It offers 500J energy on 2, and 4 KV ranges, that allows its use on LT networks effectively.

 

Pre-location

SWT 4 has built-in current coupler that can be used to get the fault distance measurement carried out on a suitable TDR on Impulse Current Mode. It can also be coupled to other instrument compliments such as Arc Reflection Filter to get reliable results of the fault distance.

 

Pin-Point Location

Surges of high energy are applied to the fault at the set voltage and time interval for pin-pointing the exact spot on the cable length.

These surges create noise and vibrations at the fault site. The intensity of the noise and vibrations get attenuated during their travel to the ground surface. A ground micro­phone and a sensitive surge wave receiver SLE 90, carried on the route of the cable on the pre-located area pin-point the exact spot of the fault in minimum time.

 

Single Impulse and repetitive surges

The instrument has single impulse mode, by which a single shot of surges is applied to the fault for ascertaining the level offault breaking.

This mode is also necessary for pre-location tests to be carried out with other instrument compliments. Repetitive timings of 4 and 8 second intervals are suitable for pin-pointing the fault.

 

Safety controls

SWT 4 employs safety controls for personnel and instrument safety. Variac zero, HV switch interlock, output cable plug interlock, instant earth discharge of internal capacitor bank and the cable under test at the time of switching off/tripping offer absolutely safe operational condition. Tripping with indication and non operation of the instrument due to over heat condition caused due to any problem, safeguards the instrument for any damage. This safety control resets automatically after cooling down to normal condition.

 

Customer service

All instruments have been designed based on safety, capability, field application, ruggedness and ease of operations. We try to offer the best possible solutions for the job. We not only offer our after sales services to the customers through our branches / authorized agents, but also offer training to the working staff of the customer under specialized training programs.

 


 
 

Portable Cable Fault Locator

Portable Cable Fault Locator
Compact and lightweight cable fault locator TFL 5 is most suitable for field application. It uses state of the art digital
technology for precise location of faults in underground metallic cables. It is a menu driven microprocessor based Time
Domain Reflectometer (TDR), which can locate open or short circuit faults on any type of metallic cables. The advanced
circuitry utilizes high-speed sampling of 500 Ms/s for better resolution of echograms.
The instrument incorporates a unique feature of automatic placement of measuring cursor at fault point. This makes it
totally user friendly and any operator having minimal knowledge can successfully locate the fault.

Features
  • Very small size, easily portable light weight, Palm-held ABS plastic housing
  • Easy to use Menu driven operation
  • Automatic and manual measurement modes by cursor
  • Data storage of test settings for quick recall
  • Data storage of up to 20 Test results
  • Printout facility with Ext. Printer or a PC via RS 232 Serial port
  • Use of high speed Micro-controller
  • Use of high resolution back-lit LCD Display
  • Very low power requirement with built in Lithium-Ion rechargeable batteries Capable of
  •  giving 8-10 hrs. of uninterrupted working
  • Built in battery charger
  • Improved minimum and maximum fault location range
  • Tests any type of telecom, coaxial, network or power cables
  • Automatic / Manual settings for VOP for different types of cables
  • Zoom for detailed examination around fault point
  • Self check facility
  • Auto shut down under idle running condition
  • Low-Battery Indication
Operation

The cable fault locator TFL 5 is a portable field instrument working on Time Domain Reflectometry (TDR) principle, using
advanced digital technology. It is designed to locate faults in any type of metallic cables, such as unloaded
telecommunication or power, network or co-axial cables. It sends a pulse of energy on the cable that propagates towards the
far end. This pulse returns to the sending end from the point of mismatch of impedance. The transmitted and reflected
pulses simultaneously appear on the LCD screen as an echogram and a measuring cursor is automatically set to the point
of fault. The location of the measuring cursor computes the fault distance from the sending end. However, in case of
complex fault, the cursor can be set manually at the fault point.
The velocity factor (VOP) is automatically set for the type of cable selected through the menu.
However, it can be set manually by getting the reflection on a known length of same type of cable.
The active echogram of a faulty pair/core can be compared with the healthy one stored in one of the memory locations. The
data of echograms can be downloaded to a PC through the RS 232 port.
TFL 5 can typically locate open and short circuit faults. It can also be used for other faults such as series and shunt, split
pairs and ingress of moisture faults. It can also indicate locations of cable joints.


 
 

Portable Line Tester

Portable Line Tester
  • Test all line parameters automatically by pressing a single key

  • GO/NO-GO indication with audible alarm for:

    • Foreign potential

    • Low cross insulation

    • Short on line

    • Full earth

  • Test termination of push button telephone instruments

  • Single key operation

  • Operates on ordinary battery (4 Cells)

  • Auto power shut to conserve battery

  • Hi-tech micro processor based design

  • Portable, light weight and sturdy

  • Accessories

    • pair of test lead and operation manual.


 
 

SWR For Pinpoint Location

SWR For Pinpoint Location

Specifications

Acoustic Channel

: Broad band filter 70 - 3000 Hz.

Magnetic Channel

: 9820 Hz ^10Hz bandwidth filter.

Indication

: Dual LCD bargraph display to indicate the levels of acoustic and

 

magnetic channels and to check battery status.

Grain

: More than 96 dB for both the channels.

Input Impendence

: 500 Ohm for ground microphone.

Output Impendence

: 500 Ohm for headphone.

Current Supply

: 1.5VX8AAsizebatteries.

Operating Time

: Morethan 12 hrs. Continuous.

Weight

: 1.5 kg. with batteries.

Dimensions (mm)

: 240 (L)x80(H) x190(D)mm

Operating Temperature

: -10degCto50degC

Storage Temperature

: -15degCto55degC

Standard accessories

: Ground microphone MIC - S, Headphone AH1

 


 
 

Soft Discharge Rod

Soft Discharge Rod

Soft Discharge Rod

Reliable and cost effective Soft discharge rods

Damped discharge of the cable/ Device Under Test (DUT), through suitable resistor.

Range: 11kV-100kV working for maximum capacity discharge up to 6 microfarad.

Robust housing of reinforced fibre glass having protection ring

and rubberised handle for proper grip.

Supplied with cushioned soft carrying case to withstand

severe transport jerks and shocks.

Each rod is provided with 10sq. mm, 5 mtr flexible cable having

heavy duty brass clamp for earth connection.

 

Customer Service

All instruments have been designed based on safety, capability, field application, ruggedness and ease of operations.

We try to offer the best possible solutions for the job.

We not only offer our after sales services to the customers through our branches / authorized agents, but also give training to the working staff of the customers under specialized training programs.

 

Specifications

SDR

Model

Damping Resistor

Max. Capacity discharge

Max. Working voltage (kV)

Dimensions

Weight

SDR-1/11kV

10KOhm

6 MFD

11 kV

,032 mm x(L)750 mm

1.65 Kg

SDR-1/35kV

10KOhm

6 MFD

35 kV

JZf32mm x(L) 960 mm

2.2Kg

SDR-1/100 kV

20KOhm

10 MFD

100 kV

#32mm x(L) 1800 mm

4.5Kg

 



 
 

Specifications Of Cable Route Tracer

Specifications of Cable Route Tracer

Specifications

Audio Frequency Generator - AFG 200

Output

5-25-50 - 100 -200 Watts selectable.

Output Frequencies

480 Hz -1.45 kHz - 9.82 kHz selectable. (All frequencies quartz-controlled)

Matching

Matching ofthe Output impedance ofthe connected cable is carried out in the

 

range 0.5...1000 Ohms.

Indication

Meter Indication of - relative transmitted power and matching

Current Supply

Mains connection 230 V 10% AC50Hz

Dimensions (mm)

411 (L)x160 (H) x400 (D)

Weight

20Kg.

 

Audio Frequency Receiver - AFR 4 with active filter circuit

Receiving Frequencies

a. Passive:50or60Hz b. Active : 480 Hz, 1450 Hz, 9820 Hz.

Gain

100...7000 Hz greater than 90 dB

Indication

LCD bar - graph display with scale illumination for:

 

a. Signal strength b. Battery status.

Dimensions(mm)

240 (L)x110(H)x155(D)

Weight

1.6 Kgs with batteries.

 

Universal Search Coil -SC4

Receiving Frequencies

(50 Hz - 480 Hz) -1.45 kHz - 9.82 kHz switchable

Axis of coil

Can be swivelled 45 deg. / 90 deg.

Dimensions(mm)

470x80x207

Weight

1.05 Kg (approx)

 

 


 
 

Specifications Of High Voltage Test Instruments

Specifications of High Voltage Test Instruments

High Voltage Test Instruments

Power Supply

230V/240VAC,50-60 Hz

Output Voltage

Continuously variable

Output Current

selectable by rotary switch

Output voltage indication

Analog / Digital Meter in kV

Range of models

 

Sr.

Model

DC

AC (Optional)

Dimensions

Weight

No.

 

Rated Voltage Rated Current

Rated Voltage

Rated Current

(LxWxH) mm

(kg)

 

 

(kV)

(mA)

(kV)

(mA)

 

 

01

HVG 40

40

20

-

-

B

32 kg

02

HVG 50

50

10

30

10

a+c

80 kg

 

DIMENSIONS

a = Control Unit

525x 250x310 mm

b= Single Unit

555x 285x515 mm

c = HV Unit

750x 710x750 mm

 

 

 

 


 
 

Specifications Of Sheath Fault Tester

Specifications of Sheath Fault Tester

Specifications

SFL 1

Sheath Fault Tester

Power Supply

230V/240VAC,50-60 Hz600VAMAX.

Test Voltage

0 - 2.5 kV 200 mA max

 

0-5kV 100mA max

Pulse ratio (Pin-pointing)

1:3s, 1:6 s (On-Offtime ratio)

Sheath drop indication

4.5 digit DPM 0-1.9999 V indication

Fault Distance Calculator

Display: 16x2 Character backlit LCD

 

Memory storage: 3 volatile memories

DPM power supply

6V1.5 AH rechargeable battery with external battery charger

Dimensions

450(L)x266 (W)x370 (H)mm

Weight

29 Kg approx

 

Sheath Fault Receiver EFL 1

Sensitive galvanometer with six stage amplification

Power Supply

8x1.5V alkaline AA size batteries

Dimensions

235 (L)X132 (W) X127 (H) mm

Weight

1.8 Kg.

 

Probes

Length

1000 mm

Weight

1.5Kg

Detatchable in two parts for ease of transport


 
 

Telephone Analyzer

Telephone Analyzer

Telephone Analyzer

  • Complete Dial Tests

  • Simultaneous display of

  • Dial Speed in IPS

  • Dial Ratio in %

  • Digit Count

  • IDP in MS in electronic telephones

  • Digit test for all digits in live & isolated modes.

  • GO/NO-GO test facility 

  • Total Telephone Tests

  • Receivers Test

  • Tranmiter Test

  • Ring Test

  • Hook Switch test

  • Dial Test

  • Digital display of Bell condenser

  • Continuty test

  • Test all types of telephones - Rotary & Push button types.


 
 

Water Leak Detector

Water Leak Detector


WLD 90

Water escaping at the leak spot strikes the surrounding soil, generating sound waves that propagate up to ground surface. These waves are received by the ground microphone when it is placed in the vicinity ofthe leak spot. Receiver amplifier connected to it enables the operator to hear the leak noise through headphones and signal level is displayed through an indicator to locate the leak spot accurately. There are several factors, such as pressure in the pipeline, type of leak (small or big puncture, failure of gasket or joint) that govern the sound wave frequency. Therefore the receiver amplifier should have selective filters for all type of leak noises.

 

Operation

WLD 90

Before commencing the operation, check and note down the pipeline material, diameter and pressure. The conductivity of sound waves and their propagation characteristics depend on the material of the pipeline (Fig. 2) Ground microphone MIC is kept on the ground surface, at marked route of the pipeline. The volume is set to middle position for comfortable audio signal received at headphones.

Sensitivity is selected to give full scale deflection by small noises such as tapping the ground. Initially broad band filter E (120-1800 Hz) is selected for preliminary search. The ground microphone should be placed on the route of the pipeline at an interval of 1 m distance.

 

Accessories

WLD 90

1. Ground Microphone MIC

2. Headphone

3. Stick

4. Carrying case

 

Specifications

WLD 90

Frequency Selector

Six positions A(240 Hz), B(400 Hz), C(650 Hz), D (1100 Hz), E (1800 Hz), F (3000 Hz)

Microphone

MIC Ground Microphone

Display

LCD Bar graph to display level of leak sound.

Mute switch

To disconnect Headphones from amplifier

Battery

Nominal Voltage 12VDC Type 8xAAtype Alkaline batteries

Operating Temperature

-10degCto 50 degC

Storage Temperature

-15degCto55degC

Dimensions

175(W)x75(H)x205 (D)mm

Weight

Net 1 (kg.)

 

Other associated equipment recommended Pipe route locator Model PL 8

for exact alignment of pipe line.


 
 

 

Related Product Catalogs

Sheetal Corporation
Supplying torque tester, digital torque testers, slip torque testers, electronic torque testers, voltage testers, compact voltage tester, hand operated voltage testers, digital voltage tester and double pole voltage tester.

View more details

Rangani Engineering Private Limited, Rajkot
Established in 1988 we are a leading manufacturer of hydro test machine, testing machines and hydro testing machine for testing valves from India.

View more details

Sunshine Instruments
We are exporter & trader of ph testers, testing equipment, gravity meter, analytical instruments, analytical instruments, digital measuring instruments etc.

View more details

Suggested Companies


Related Categories
Search Suppliers
CompanyProductsTrade Leads
OR


IndiaMARTCompaniesProductsTrade LeadsTendersTrade ShowsTravel
© 1996-2012 IndiaMART InterMESH Limited. All rights reserved worldwide.