PVC Insulated Cables
We offer a wide assortment of PVC insulated cables, which are used in permanent power equipment as well as lighting installations. These cables have been appreciated for their High conductor temperature and high insulation capacity.
View Enquiry Basket
Flexible Single Core Cables  Our range of single core cables are used for battery cables, transmission of low voltage signals, electric motors, D. C. power transformers, panel boards and others. These are fabricated with high quality raw material to ensure maximum efficiency and performance.
| Area in Sq mm | Conductor Construction No. Wire/ mm | Conduction Dia in mm | Max DC ResistanceOhm/ Km at 20 Degree C | Insulation Thickness in mm Nominal | Cables Dia (Approx.) | Current Rating in Amp | | 0.5 | 16/0.20 | 0.94 | 39 | 0.6 | 2.2 | 4 | | 0.75 | 24/0.20 | 1.2 | 26 | 0.6 | 2.5 | 7 | | 1 | 32/0.20 | 1.34 | 19.5 | 0.6 | 2.6 | 12 | | 1.5 | 30/0.25 | 1.64 | 13.3 | 0.6 | 2.9 | 15 | | 2.5 | 50/0.25 | 2.08 | 7.98 | 0.7 | 3.5 | 20 | | 4 | 56/0.30 | 2.61 | 4.95 | 0.8 | 4.3 | 27 | | 6 | 84/0.30 | 3.5 | 3.3 | 0.8 | 5.3 | 35 | | 10 | 140/0.30 | 4.6 | 1.91 | 1 | 6.7 | 46 | | 16 | 101/0.45 | 6 | 1.21 | 1 | 8.2 | 62 | | 25 | 158/0.45 | 7.6 | 0.78 | 1.2 | 10 | 80 | | 35 | 220/0.45 | 8.7 | 0.554 | 1.2 | 11.3 | 102 | | 50 | 315/0.45 | 10.6 | 0.386 | 1.4 | 13.5 | 138 | | 70 | 440/0.45 | 12.3 | 0.272 | 1.4 | 15.5 | 214 | |  |
Add to Enquiry Basket
Flexible Multi Core Cables  We are providing a range of flexible multi core cable which is used for electric power supply, modern electrical appliances equipment and others. These are durable and available in various thickness and sizes to suit the varied requirements of the clients.
| 6 | 10 | 16 | 25 | 35 | | | | Construction No. of Wire/ mm | | 84/0.30 | 140/0.30 | 101/0.45 | 158/0.45 | 220/0.45 | | Cond. Dia. In mm | | 3.5 | 4.6 | 6 | 7.6 | 8.7 | | Max. DC resistance Ohm/ km at 20 Degree C | | 3.3 | 1.91 | 1.21 | 0.78 | 0.554 | | Insulation thickness nominal mm | | 0.8 | 1 | 1 | 1.2 | 1.2 | | Core Dia mm | | 5.1 | 6.6 | 8 | 10 | 11.1 | | Sheath Thickness in mm Nominal | 2 Core | 1.15 | 1.4 | 1.4 | 2 | 2 | | | 3 Core | 1.15 | 1.4 | 1.4 | 2 | 2 | | | 4 Core | 1.4 | 1.4 | 1.4 | 2 | 2 | | Overall Thickness in mm approx. | 2 Core | 12.6 | 16 | 18.8 | 24 | 26.3 | | | 3 Core | 13.4 | 17 | 20.1 | 25.6 | | | | 4 Core | 15.2 | 18.8 | 22.2 | 28.2 | | | Current Rating Amp. | | 33 | 45 | 60 | 75 | | |  |
Add to Enquiry Basket
Solid & Stranded Cables  We also supply a range of solid and stranded cables which are used for fixed wiring, house / domestic wiring / project & industrial plants and others. Further, these are also used for fixed wiring, house/ domestic wiring/ Project & Industrial Plants and others.
Specifications:- Standards: as per ISI-694 & B.S. 2004 standard
- House service wires as per IS-694/90, with ISI mark
- Raw Material: "poly Flex" Single Core solid & stranded bright annealed copper conductor PVC sheathed wires 650/ 1100 volt grade
| Area in Sq. mm | Strands mm | Insulation Thickness mm | Overall Diameter mm | Insulation Thickness mm | Sheath Thicknessmm | Overall Diameter mm | Resistance at 20 Degree C Ohm/ Km) | Current Rating Amps. | | 1 | 01/01/12 | 0.7 | 2.6 | 0.6 | 0.8 | 4.15 | 18.1 | 11 | | 1.5 | 01/01/38 | 0.7 | 2.9 | 0.6 | 0.8 | 4.4 | 12.1 | 13 | | 2.5 | 01/01/78 | 0.8 | 3.5 | 0.7 | 0.8 | 5 | 7.41 | 20 | | 2.5 | 03/01/04 | 0.8 | 3.9 | 0.7 | 0.8 | 5.1 | 7.41 | 20 | | 4 | 01/02/24 | 0.8 | 4 | 0.8 | 0.9 | 5.85 | 4.61 | 26 | | 4 | 7/0.85 | 0.8 | 4.2 | 0.8 | 0.9 | 5.9 | 4.61 | 26 | | 6 | 01/02/76 | 0.8 | 4.5 | 0.8 | 0.9 | 6.4 | 3.08 | 35 | | 6 | 07/01/04 | 0.8 | 5 | 0.8 | 0.9 | 6.65 | 3.08 | 35 | | 10 | 07/01/35 | 1 | 6.2 | 1 | 0.9 | 8.05 | 1.83 | 45 | |  |
Add to Enquiry Basket
PVC FRLS Cables  We also offer PVC FRLS cable, which are flame retardant low smoke electrical wires. These are manufactured using electrolytic grade copper to ensure superior conductivity.
Due to fire resistant quality, these cables are ideal for concealed and conduit wiring in multi-storeyed buildings such as hotels, banks, hospitals, commercial & residential complexes and others.
Characteristics:- Flame Retardance low smoke emission
- Low Acid Gas Emission
- Designed as per IS/1554 (Part I)
- Over and above these standard tests, FRLS cables and its components are put to a series of special tests to fulfill the need of improved performance characteristics.
Physical Testing- Flammability Test
- Chimney Test for Class F3 as per Swedish Standards SS 424 1475
Applications:- High-rise buildings
- Data processing centers
- Hospitals
- Theaters
- Hotels
- Schools
- Warehouses
- Industrial complexes
- Power
- Stations
- Underground railways
- Oil platforms
- Areas where safety of personnel and protection of equipment is absolutely vital
Features:- Made from bare annealed copper wire with purity of 99.97%
- Low conductor resistance
- Lower heating and saves the power consumption
- The FRLS Insulation used in this cables are mfg with special grade of formula, which are free from acidic gas
- Flame retardant
- Low smoke emission
- Low halogen acid emission
Advantages:- Resists burning to a large extent
- High ignition point
- Does not emit smoke
- Almost 100% visibility
- Non toxic and no poisonous
- Negligible smoke
- Clear visibility
- Much slower propagation of flames is.
|  |
Add to Enquiry Basket
Fire Retardant Cable  We offer superior performance oriented fire retardant cables, which comes with a compound named propylene filled inside them that ensure high effectiveness of the cables. These are manufactured as per defined industry standards to offer high level of satisfaction to our clients.
Application:- These cables are mainly used in commercial wires & highly voltage fluctuation areas like electricity board
Features:- Prevent the conversion of an electric spark in to a fire
- Simultaneously the PVC formula stop fire structure along with wiring
|  |
Add to Enquiry Basket
Zero Halogen Free Flame Retardant Cables  Our range of Zero Halogen Free Flame Retardant (ZHFR) Wire is widely used for building wiring and has been widely appreciated among our clients. These are recommended especially in a situation where high degree of safety of personnel and equipment are obligatory like hotels, theaters, hospitals, high-rise buildings, commercial complexes, centrally A.C offices, residential properties and others.
Features:- Non-toxic smoke house wires for building wiring
- Uninterrupted power
- Enabled with alarm circuits, exit lights, lifts & other emergency circuits
- Electrical properties
- High thermal stress resistance
- Excellent mechanical properties
- Good flame retarding ability
- Low smoke formation and long term reliability
- ZERO HALOGEN Insulation provides better flame retardant properties then HR & FRLS
- Zero Halogen required >300°C temperature to catch fire (with 1%0xygen).
|  |