Control & Automation Products |
|
|
Digital Timers, Current Controllers, Digital Temperature Indicators, Temperature Controllers, Process Controllers, Flow indicator cum totalizer, Data Scanners and Data Loggers
|
 |  |  |  |  |

| Digital Programmable Timers Our Range Of Timers Include: - Single Channel Programmable Timer
- Single Channel Six Digit Programmable Timer
- Single Channel Six Digit Programmable Time Totaliser
- Programmable Cyclic Timer.
- Programmable Sequetial Timer.
- Digital Time Switch
|  |  |  |  |  |  |

| Dual Channel Bargraph Indicator Classic Features : - Maximum 2 analogue input with any combination.
- Universal input type for thermocouple J, K , R, S, T, RTD(PT-100), 4 - 20mA, 0 - 10V, please specify input while order.
- Automatic cold junction compensation for thermocouples.
- Automatic wirelength compensation for long wire RTD inputs.
- Very high accuracy 0.25%, With software linearization.
- Temperature sensor break, ‘oPEn’ indication.
- Under Range ‘undr’& over range ‘OuEr’indication for 4 to 20 mA & 0 - 10VDC linear input.
- Easy on-line field calibration by user by front keys.
- Reading offset facility to compensate the field error.
- Provision for square root extraction for flow measurement.
- Facility to bypass the facility for square root extraction.
- 101 Segment Bargraph for each input.
- Optional 4-20mA retransmission output.
- Two independent set points individual for each channels.
- Hysterisis : Programmable for relay output.
- Output - 1 NO/C/NC Relay contact rated 230 V/5Amp. for both relay 1 (ALARM 1) & relay 2 ( ALARM 2) for inputs.
- Programmable latch & non-latch facility for common relay & relay Indication.
- Optional RS-232 / RS-485 serial port with modbus RTU protocol.
- Optional on line Data Acquisition computer software.
- Optional Parallel port for direct printout on 80 column dot-matrix / printer without need of computer(PC).
Description :The TC-403B Bargraph Indicator is a part of TC series intelligent Microcontroller based Indicator instrument for realization of economic solution of process control problem It show process in and with bargraph to replace conventional analog indicating instrument all the parameters are programmable through front keypad. It is mostly used in: - Primary & auxiliary temperature & data monitoring of boiler.
- Iron & steel industries for soaking pits oxygen plate, smelter plant.
- Sugar industry for Pan alternation, dailer automation.
- Chemical & petrochemical industry.
Technical Specifications:- | Compensation : | Automatic cold junction compensation for thermocouples. Automatic wirelength compensation for long wire RTD inputs. | | * Display : | 4 digit seven segment L.E.D. Display of 8mm. height for each channel. | * Bargraph Display : | 101 Segment Bargraph (RED colour L.E.D) for each channel | | * Alarm : | AL1 & AL2 Alarm indication for each channel with H / L, H / VH, L / VL. | | * Output : | Four independent & isolated relay contacts in NO/C/NC. | | * Square root : | It has provision of Square root extraction of input signal for each. It has provision of by-passing the facility for square root extraction. | | * Hysterisis : | Selectable through keypad. | | * Power Supply : | 230VAC ±10% 50Hz or 110VAC ±10%, 50Hz | | * Mounting : | Panel Mounting, metal body | | * Dimension : | 72(W) X 144(H) X 370(D) in mm. | | * Cutout : | 68(W) X 138(H) in mm. | | * Weight : | 2Kg | |  |  |  |  |  |  |

| Energy Saver Energy Saver (Delta - Star Convertor) DP - - Programmable range of 25/5, 50/5, 100/5, 150/5,
- Automatic C.T ratio selector so that same unit can be used upto C.T ratio 250 / 5 Amp.
- Smooth and reliable change over to delta, when goes above set current.
- Compact size and easy to instal.
- “ADD ON” unit between existing star delta starter & motor.
- Advance microcontroller based technology, inherently more reliable and accurate.
- Direct digital display of current drawn by load.
- Built-in time totalizer for star running time to know saving
- Delay timer 1-99 second for delta to star change over.
- Star run indication on front.
- Used latest microcontroller based technology.
- Program setting by three soft membrane keys front panel.
- Built-in watch-dog circuit for fail safe operation.
- Delay timer 1-99 second for delta to star change over.
- Star run indication on front.
Technical Detail:-In any industries electrical motors accounts for 55% to 60% of the electrical energy consumption Induction motors operate efficiently as long as they are loaded upto 60% to 85% loading. When these motors are operated below 50% loading the efficiency and power factor is very low. During lightly loaded condition (less than 50% loading), it is preferable to run motors in star instead of delta which makes you reduce your electrical bill. Advantages :- - Voltage across winding reduces to 58% of rated voltage and line current reduces to 1/3rd3 Thus reduction in iron and copper losses, hence less power consumption, reduce power bills.
- Improvement in power factor and efficiency or no need of power factor correction capacitor.
- Energy saving from 5% to 35% depending on % loading of motor (no load to 50% loading. At 50% load minimum saving and at no load maximum saving).
- Decrease in line current which gives additional savings in cable losses and losses in switch gears.
- No need of changing motor to lower KW.
Application: - Under loaded equipment like pumps, blowers, agitators, ball and roll mills etc. or In process where load varies at different stages (3 phase machines only).
- Machine shop industries: Like lath M/C, power press, drill M/C, Boaring M/C, etc. (3 phase machine only).
- I/D fan, F/D fan.
- AHU blower fan etc.
|  |  |  |  |  |  |

| Data Scanners TC-800 : Classic Features:- - Maximum 8 analogue input with any combination.
- Universal input type for thermocouple J, K , R, S, T, RTD (PT- 100), 4 - 20mA, 0 - 10V, please specify input while order.
- Automatic cold junction compensation for thermocouples.
- Automatic wire length compensation for long wire RTD inputs.
- Very high accuracy 0.25%, With software linearization.
- Temperature sensor break, ‘oPEn’ indication.
- Under Range ‘undr’& over range ‘OuEr’ indication for 4 to 20 mA & 0 - 10VDC linear input.
- Easy on-line field calibration by user by front keys.
- Built in temperature reading in °C or F by user selectable.
- Individual channel SKIP, HOLD facility from front panel.
- Reading offset facility to compensate the field error.
- Field programmable channel scan time 1 to 59 seconds.
- Two independent set points individual for each channels with two common relay.
- Hysterisis : Programmable for relay output.
- Output - 1 NO/C/NC Relay contact rated 230 V/5Amp. for both relay 1 (ALARM 1) & relay 2 ( ALARM 2) common for all channels.
- Programmable latch & non-latch facility for common relay & relay Indication.
- Optional RS-232 / RS-485 serial port with modbus RTU protocol.
- Optional on line Data Acquisition computer software.
- Optional Parallel port for direct printout on 80 column dotmatrix / printer without need of computer(PC).
- Field programmable print interval 5 to 9999 seconds. Printers with real time clock for on line printing.
- Optional individual relay output can be given for each channel
Technical Detail:-
| Compensation : | Automatic Cold Junction Compensation for all thermocouples. | | Display : | 4 digits of 13 mm. height L.E.D for process value display 1 digit of 13mm. height L.E.D for channel number display. 8 L.E.Ds for Alarm Indication. AL1 L.E.D get ON, AL 2 L.E.D's get continous blink. | | Setting : | 5 feathers touch keys on front panel. | | Alarm : | 2 independent set points individual for each channels with 2 common relay output. | | Output : | 1 NO/C/NC Relay contact rated 230V/5A for relay1 (AL1) & relay2 (Al2). | | Port : | RS-232/RS-485 Serial port with Modbus output or parallel centronics port for 80 column computer printer for direct printout. | | Supply : | 230VAC A10%, OR 110VAC A10%, 50Hz. | | Mounting : | Panel mounting. | | Dimension : | 96(W) X 96(H) X 175(D) in mm. | | Cutout : | 92(W) X 92(H) in mm. | | Cabinet : | ABS plastic, white colour. | | Optional : | a) Datalog Data Acquisition windows based software for real time trending.. B ) Parallel port for direct printout on 80 column dot-matrix / printer without need of computer(PC) C) Individual relay O/P can be given for each channel or with grouping O/P. | | Weight : | 750 gram (approx.). | |  |  |  |  |  |  |

| Digital Programmable Controllers - Single set point 3 1/2 Digit On-Off Temperature Controller
- Single Set Point 3 1/2 Digit Time Proportional Temperature Controller
- Dual Set Point 3 1/2 Digit On-Off
- Dual Set Point 3 1/2 Digit Timer Proportional ( First Setpoint Only) Temperature Controller
- Digital Temperature Controllers Wirh Flameproof Housing
- Microprocessor Based Programmable Two Set Point On-Off Controller
|  |  |  |  |  |  |

| Universal Process Controller Classic Features :- - Universal input type for thermocouple J, K , R, S, T, RTD(PT-100), 4 - 20mA, 0 - 10V,
- Automatic cold junction compensation for thermocouples.
- Very high accuracy 0.25%, With software linearization.
- Temperature sensor break, ‘oPEn’ indication.
- Under Range ‘undr’& over range ‘OuEr’indication for 4 to 20 mA & 0 - 10VDC linear input.
- Easy on-line field calibration by user by front keys.
- Built in temperature reading in °C or F by user selectable.
- Reading offset facility to compensate the field error.
- Two independent set points individual for each channels with two common relay.
- Hysterisis : Programmable for relay output.
- Output - 1 NO/C/NC Relay contact rated 230 V/5Amp. for both relay 1 (ALARM 1) and relay 2 (ALARM 2) common for all channels.
- Programmable latch & non-latch facility for common relay & relay Indication.
- Optional RS-232 / RS-485 serial port with modbus RTU protocol.
- Optional on line Data Acquisition computer software.
- Optional Parallel port for direct printout on 80 column dot-matrix / printer without need of Computer.
Applications :- The TC-403L universal process controller is a pert of TC series intelligent microcontroller based indicator instrument for realization of economic solution of process control problem. It is mostly used in, - Heat treatment control system.
- Pharmaceutical validation, ISO Certification and validation.
- Online recording for Oven & BOD, Incubator, Humidity Chamber.
- Winding temperature of generators, bearings, motors, transformers.
- Heat treatment in furnace.
- Primary & auxiliary temperature scanning of boiler.
- Iron & steel industries for soaking pits oxygen plate, smelter plant.
- Sugar industry for Pan alternation, dailer automation, Chemical & petrochemical industry.
Technical Specifications :- | Compensation : | Automatic Cold Junction Compensation for all thermocouples. | | Display : | 4 digits of 13 mm. height L.E.D for process value display 1 digit of 13 mm. height L.E.D for channel number display. 2 L.E.Ds for Alarm Indication. A L1 & A L 2. | | Setting : | 5 feathers touch keys on front panel. | | Alarm : | 2 independent set points with 2 relay output. | | Output : | 1 NO/C/NC Relay contact rated 230V / 5A for relay1 (AL1) & relay2 (AL2). | | Port : | RS-232/RS-485 Serial port with Modbus output or parallel centronics port for 80 column computer printer for direct printout. | | Supply : | 230VAC A10%, OR 110VAC A10%, 50Hz. | | Mounting : | Panel mounting. | | Dimension : | 96(W) X 96(H) X 175(D) in mm. | | Cutout : | 92(W) X 92(H) in mm. | | Cabinet : | ABS plastic, Black colour. | | Optional : | a) Datalog Data Acquisition windows based software for real time trending.. b) Parallel port for direct printout on 80 column dot-matrix / printer | |  |  |  |  |  |  |

| Flow Totaliser Programmable Flow Totaliser :- - Used latest microcontroller based control technology.
- 0.01, 0.1, 1 resolution programmable rate.
- 6-digit 0-999999 count, for total, 0-5999 rate for full range w.r.t 4 to 20mA, 0 to 75mV, RTD.
- Two set point with bright L.E.D for RL1 & Rl2.
- Accept input form standard flow transmitter having output of 4 to 20mA or 0 to 1VDC.
- Display both flow rate & flow totalizer by press of a (+) key.
- Two bright L.E.Ds for RL1 & RL2 indication
- Front & remote reset facility for totalizer.
- Non-volatile battery backup to hold data in case of power failure.
- Built-in watch-dog circuit for fail safe operation.
- Program setting by three soft membrane keys on the front panel.
- Compact, Standard, din size & easy to install.
- Optional flameproof version is available on request.
Technical Specifications :- | Input : | Automatic Cold Junction Compensation for all thermocouples. | | Display : | 4 digits of 13 mm. height L.E.D for process value display 1 digit of 13 mm. height L.E.D for channel number display. 2 L.E.Ds for Alarm Indication. A L1 & A L 2. | | Setting : | 5 feathers touch keys on front panel. | | Alarm : | 2 independent set points with 2 relay output. | | Output : | 1 NO/C/NC Relay contact rated 230V / 5A for relay1 (AL1) & relay2 (AL2). | | Port : | RS-232/RS-485 Serial port with Modbus output or parallel centronics port for 80 column computer printer for direct printout. | | Supply : | 230VAC A10%, OR 110VAC A10%, 50Hz. | | Mounting : | Panel mounting. | | Dimension : | 96(W) X 96(H) X 175(D) in mm. | | Cutout : | 92(W) X 92(H) in mm. | | Cabinet : | ABS plastic, Black colour. | | Optional : | a) Datalog Data Acquisition windows based software for real time trending.. b) Parallel port for direct printout on 80 column dot-matrix / printer | |  |  |  |  |  |  |

| Data Loggers Classic Features:-
- Datastore capacity of 5000 reading of all eight channels.
- Built in memory saturation, scrolling around & on line printing.
- Maximum 8 analogue input with any combination.
- Universal input type for thermocouple J, K , R,S, T, RTD (PT-100), 4 - 20mA, 0 - 10V, please specify input while order.
- Automatic cold junction compensation for thermocouples.
- Automatic wire length compensation for long wire RTD inputs.
- Very high accuracy 0.25%, With software linearization.
- Temperature sensor break, ‘oPEn’ indication.
- Under Range ‘undr’ & over range ‘OuEr’indication for 4 to 20 mA & 0 - 10VDC linear input.
- Easy on-line field calibration by user by front keys.
- Built in temperature reading in °C or F by user selectable.
- Individual channel SKIP, HOLD facility from front panel.
- Reading offset facility to compensate the field error.
- Field programmable channel scan time 1 to 59 seconds.
- Two independent set points individual for each channels with two common relay.
- Hysterisis : Programmable for relay output.
- Output - 1 NO/C/NC Relay contact rated 230 V/5Amp. for both relay 1 (ALARM 1) & relay 2 (ALARM 2 ) common for all channels.
- Programmable latch & non-latch facility for common relay & relay Indication.
- Optional RS-232 / RS-485 serial port with modbus RTU protocol.
- Optional on line Data Acquisition computer software.
- Optional Parallel port for direct printout on 80 column dotmatrix printer without need of computer (PC).
- Field programmable print interval 5 to 9999 seconds. Printers with real time clock for on line printing.
- Optional individual relay output can be given for each channel.
Technical Specifications:- | Compensation : | Automatic Cold Junction Compensation for all thermocouples. | | Display : | 4 digits of 13 mm. height L.E.D for process value display. 1 digit of 13mm. height L.E.D for channel number display. 8 L.E.Ds for Alarm Indication. AL1 L.E.D get ON, AL 2 L.E.D's get continous blink. | | Memory : | Datastore capacity of 5000 readings for all channel (total 125KB memory). | | Setting : | 5 feathers touch keys on front panel. | | Alarms : | 2 independent set points individual for each channels with 2 common relay output. | | Output : | 1 NO / C / NC Relay contact rated 230V / 5A for relay1 (AL1) & relay2 (AL2). | | Port : | RS-232/RS-485 Serial port with Modbus output or parallel centronics port for 80 column computer printer for direct printout. | | Supply : | 230VAC A10%, OR 110VAC A10%, 50Hz | | Mounting : | Panel mounting | | Dimension : | 96(W) X 96(H) X 175(D) in mm. | | Cutout : | 92(W) X 92(H) in mm |
|  |
|