We are a distinguished manufacturer and supplier, accredited with ISO 9001: 2000 certificate, offering an extensive assortment of Home UPS


Hi-Lite UPS
Large View

Hi-Lite UPS

Hot Product

Pure Sine Wave Output

UTL HI-LITE is a noiseless high frequency combo system. It is extremely light weight, 810 VA weighs only 2.5 Kg, yet has high computer compatibility. It is the safest and true combination of a ups and an inverter in one unit as it provides pure sine wave from no load to full load. Like our other combo products it is also powered by micro controller digital technology

 

Intelligent Charger

HI-LITE incorporates smart multilevel charging providing good battery health which yields in longer battery life with low battery maintenance. HI-LITE achieves full charging current from 100V ac input. It provides a constant boost charging current until the voltage of battery reaches 14.2V and then float current (very close to zero) maintains it above 13V. Thus float current (flowing for the longest period in all this process) is reduced to nearly zero, ultimately resulting in much enhanced battery life, keeping battery fully charged simultaneously. Now this is the HI-LITE Intelligence that makes an ordinary battery live long like a maintenance free costly battery.

 

Auto Overload Reseting

Empowered by a smart brain HI-LITE shuts down automatically if exposed to a load more then its specified limit. In wide range it keeps on beeping and sensing the load to switch itself on to find the load within its specified limit eliminating the manual resetting by the user. If the load is not reduced it will shut down itself after 8 such attempts and user will need to restart it manually. However in narrow range it will permanently shut itself off if exposed to excessive load and the user has to reset the HI-LITE manually after decreasing the load within its specified limit

 

Any Battery Option

HI-LITE has an Intelligent Feature to recognize any battery connected to it. May it be local ordinary battery, Branded/Automotive battery, Sealed Maintenance Free battery or Tubular battery, it auto adjusts its charging characteristics according to any battery you connect. So type no bar, go for any battery you like to buy

 

No Load Shut Down

HI-LITE has this smart feature of no load shutdown, that saves the precious battery back-up for you. If there is no load on HI-LITE and AC mains is absent, it will shut itself off. It will automatically restart itself on, when you apply some load over it. This is a user configurable feature.

 

Configurable Charging Modes

HI-LITE has customer configurable charging modes. In areas where power cut is longer than 8 hours, high charging mode should be configured. Normal charging mode, which is set by default, always enhances the battery life. Customer can switch into these modes as and when required.

 

Soft Touch Switch

 

HI-LITE has soft touch switch, which is very easy to use. With this switch, all the configurations including ON,OFF,Reset & Mode Changes can be done. This switch, mounted in front, enables to feel you no going back for anything.

Combo UPS
Large View

Combo UPS

Micro Digital Technology:

UTL COMBO UPS is powered by micro controller digital technology. It was possible through only this technology that all the appliances including Tube lights, Fans & Computer can run altogether which eliminates the need of two equipments for similar applications , at your home or office. So, it is an Inverter built in a UP

Battery Health for longer life:

Battery is fed a constant boost charging current until the voltage of each Battery reaches 14.2 V and then float current (very close to zero) maintains it above 12.9 V. Thus float current ( flowing for the longest period in all this process) is reduced to nearly zero, ultimately resulting in much enhanced battery life, while keeping it fully charged simultaneously.

 

Any Battery Option:

After a period of time some Batteries do not go beyond 13.5 V while charging. Normally, in this case Battery are over charged by normal Inverters. UTL COMBO UPS declares the Battery is charged, in this conditions, and maintains it on float voltage level. This way, user has option of installing any Battery with UTL COMBO UPS. It also provides the option of battery equalizing.

 

Auto Overload Re-setting:

UTL COMBO UPS shuts down automatically if exposed to excessive load and keeps on beeping & sensing the load to switch itself on to find the load within the specified limits, eliminating the need of manual resetting by the user. If the load is not reduced UTL COMBO UPS will shutdown after 15 such attempts and user will need to restart it manually.

 

Best regulated output:

UTL COMBO UPS has regulated output voltage & frequency from no load to full load under all conditions of battery. Frequency is crystal controlled accurate 50 Hz under all conditions.

 

Technical Features:


 

Narrow Range

Wide Range

MAINS LOW CUTT OFF

185V

95V

MAINS HIGH CUTT OFF

260 V

295 V

CHARGING IN SYSTEM OFF

150 V - 295 V

150 V - 295 V

CHARGING IN SYSTEM ON

185 V - 250 V

150 V - 295 V

OVERLOAD RESET

MANUAL

AUTO

CHANGEOVER TIME

3m Sec

3 m Sec

OUTPUT VOLTAGE

220 +/- 8% V, 50.0 Hz AC

OVERLOAD CAPACITY

110% Cont., 300% for 30 mS.

BATTERY CHARGING RATE

Const. Curr. 7% of Batt. Capacity

AUDIO ALARM

Buzzer for Overload & Low Battery

EFFICIENCY

85% Typical

Sine Wave Home UPS
Large View
Download

Sine Wave Home UPS

Pure Sine Wave Output

UTL S-20 HOME UPS, is powered by micro controller digital technology. You can run all the appliances altogether including Tube lights, Fans & Computer which eliminates the need of two equipments for similar applications, at your home or office.

Battery Health for longer life

Battery is fed different charging currents varying according to battery voltage, charging current needed to maintain the battery voltage and time base, as shown in graph below. Trickle current (flowing for the longest period in all this process) is reduced to nearly zero, ultimately resulting in much enhanced battery life, while keeping it fully charged simultaneously.

Any Battery Option

After a period of time some Batteries do not go beyond 13.5 V while charging. Normally, in this case Battery are over charged by normal Inverters. UTL Hoodi...Back-up declares the Battery is charged, in this conditions, and maintains it on float voltage level. This way, user has option of installing any Battery with UTL Hoodi...Back-up. It also provides the option of battery equalizing.

Auto Overload Re-setting

UTL S-20 HOME UPS, shuts down automatically if exposed to exercise load and keeps on beeping & sensing the load to switch itself on to find the load within the specified limits, eliminating the need of manual resetting by the user. If the load is not reduced UTL S-20 HOME UPS will shutdown after 15 such attempts and user will need to restart it manually.

Best Regulated Output

UTL S-20 HOME UPS has regulated output voltage & frequency from no load to full load under all conditions of battery. Frequency is crystal controlled accurate 50 Hz under all conditions.

Sine Wave Combo UPS
Large View

Sine Wave Combo UPS

Pure Sine Wave Output

UTL Hoodi...Back-up is safest combination of UPS, Inverter and Voltage Stabilizer as it provides Pure Sine Wave Output. It is powered by micro controller digital technology. You can run all appliances altogether including Tube lights, Fans & Computer which eliminates the need of two equipments for similar applications, at your home or office.

 

Battery Health

for longer life Battery is fed a constant boost charging current until the voltage of each Battery reaches 14.2 V and then float current (very close to zero) maintains it above 12.9 V. Thus float current ( flowing for the longest period in all this process) is reduced to nearly zero, ultimately resulting in much enhanced battery life, while keeping it fully charged simultaneously.

 

Any Battery Option

After a period of time some Batteries do not go beyond 13.5 V while charging. Normally, in this case Battery are over charged by normal Inverters. UTL Hoodi...Back-up declares the Battery is charged, in this conditions, and maintains it on float voltage level. This way, user has option of installing any Battery with UTL Hoodi...Back-up. It also provides the option of battery equalising.

 

Auto Overload Re-setting

UTL Hoodi...Back-up shuts down automatically if exposed to excessive load and keeps on beeping & sensing the load to switch itself on to find the load within the specified limits, eliminating the need of manual resetting by the user. If the load is not reduced UTL Hoodi...Back-up will shutdown after 8 such attempts and user will need to restart it manually.

 

Built In Stabilizer

 

UTL Hoodi...Back-up has built in Voltage Stabilizer. It will work in both UPS & Inverter Mode. This means that no extra stabilizer is needed for input AC regulation. And charging Current will be full even if the input AC mains drops to 100V, if connected load is with in specified capacity. More importantly, this feature is user configurable. User can enable or disable it as it suits.

 

Applications

UTL Hoodi...Back-up can safely and ideally operate all appliances like Fans, Bulbs, Tube Lights, Stereos, Televisions, VCRs, Photo-Coppiers, EPABX, Intercoms, Electronic Type-writters, Water Coolers, Bio-medical Instruments and any gadget which requires 220 Volt 50 Hz AC Sine Wave supply. Special needs can be met on demand.

Contact us

Mr. Parveen Kumar Gupta (Manager)
No. 8, Community Centre, Lawrence Road, Industrial Area
Delhi - 110 035, India
Telephone:  +(91)-(11)-65805761/ 65025131

Contact via E-mail

Contact via Mobile

Contact via SMS

Home | Profile | Products | Site Navigation | Contact Us | Enquiry
Member IndiaMART.com © UPS Inverter Dot Com. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited