X
Hi
terms privacy policy
Verifying...
1

Have a requirement?
Chat with us

Hi
terms privacy policy
Verifying...
1

Have a requirement?
Chat with us

Relays

Providing you the best range of Three Phase-Single CT, Three Phase 3 CT, Single Phase Single CT and HT Power Factor Controller with effective & timely delivery.

Interested in this product?
Get Best Quote

Three Phase-Single CT

Get Latest Price

Features
  • Micro controller based DSP logic for measurements

  • All measurements with Class 1 accuracy

  • Input sensing either through line-to-line voltage with a CT or individual phase with a CT

  • Programmable external PT ratio for HT sensing

  • Voltage, Load I, Cap I THD measurement

  • Various modes of Programming step kvar, Unequal, binary, un-equal, C-series, E-series

  • RS232 OR RS485 port with TAS/MODBUS/GSM protocol in front facia for data-downloading / MODBUS connectivity / GSM connectivity

  • Protections provided: - Over/Under Voltage, Over/Under Load, Over/Under Cap. Current/THD, Load Unbalance, over temperature, Out-of-Steps indication

View Complete Details

Yes, I am interested!

Interested in this product?
Get Best Quote

Three Phase 3 CT

Get Latest Price

Features
  • Suitable for three-phase sensing applications

  • Microcontroller based DSP logic for measurements

  • All measurements with Class 1 accuracy

  • Input sensing through line-to-line voltage with a CT. Programmable external PT ratio for HT sensing

  • Auto-synchronization capable of detecting wrong connections at CT terminals, even wrong CT polarity

  • Voltage, Load I, Cap I THD measurement with odd harmonic coefficient up to 15th harmonic (SPF-35)

  • Various modes of Programming step kvar, unequal, binary, C-series, E-series (SPF-35)

  • Protections provided: - Over/Under Voltage, Over/Under Load, Over/Under Cap. Current/THD, Load Unbalance, Over Temperature, Out-of-Steps indication

  • User-friendly PC software for data logging (Both) and GSM monitoring (SPF-35). Real Time Power Factor Correction Controllers (RTPFC) offers a complete solution for Automatic Power Factor Correction employing thyristor based switching of capacitors

  • RTPFC ensures Quick Response Time (of a few electrical cycles) enabling Real time Power factor correction in critical industrial conditions. It reduces Transmission Distribution (TD) losses, minimizes Peak or Maximum Demand (MD) in power consumption and maintains power factor close to unity (1.00)

View Complete Details

Yes, I am interested!

Interested in this product?
Get Best Quote

Single Phase Single CT

Get Latest Price

Features
  • Suitable for Single-phase sensing applications

  • Microcontroller based DSP logic for measurements

  • All measurements with Class 1 accuracy

  • Input sensing through line-to-line voltage with a CT. Programmable external PT ratio for HT sensing

  • Auto-synchronization capable of detecting wrong connections at CT terminals, even wrong CT polarity

  • Voltage, Load I, Cap I THD measurement with odd harmonic coefficient up to 15th harmonic (SPF-35)

  • Various modes of Programming step kvar, unequal, binary, C-series, E-series (SPF-35)

  • Protections provided: - Over/Under Voltage, Over/Under Load, Over/Under Cap. Current/THD, Load Unbalance, Over Temperature, Out-of-Steps indication

  • User-friendly PC software for data logging (Both) and GSM monitoring (SPF-35). Real Time Power Factor Correction Controllers (RTPFC) offers a complete solution for Automatic Power Factor Correction employing thyristor based switching of capacitors

  • RTPFC ensures Quick Response Time (of a few electrical cycles) enabling Real time Power factor correction in critical industrial conditions. It reduces Transmission Distribution (TD) losses, minimizes Peak or Maximum Demand (MD) in power consumption and maintains power factor close to unity (1.00)

View Complete Details

Yes, I am interested!

Interested in this product?
Get Best Quote

We offer the trouble free automated power factor control system at 11/33 kv. The system also protects the power factor from leading the desired value.

Depending on the load pattern the autorecloser automatically adjust the capacitor bank switching. The power factor can be controlled based on the desired value of current and power factor. The feedback at reclosure is provided by Current relay/APFC relay.

A current sensing relay is connected to CT which gives the feedback to the reclosure depending on the load variation. The reclosure in turn control the switching of the capacitor bank depending upon the desired value of the current.

An apfc relay is also provided in the system . this relay directly monitors the power factor and accordingly gives the feedback to the reclosure for controlling the power factor.If the pf is lagging the desired value ,then ht capacitors are automatically switched ON.

Features
  • Intelligent KVAR based switching

  • Friendly user interface

  • Easy to install

  • Available in 4 to 16 stages (available stages 4 ,6 ,8,12,,14,16)

  • Accuracy Class 1

  • Switching Program: Intelligent (Best fit )

  • HT CT sensing for HT applications

View Complete Details

Yes, I am interested!
Tell us what you need, and we’ll help you get quotes
Tell us what you
need
Receive seller
details
Seal the deal
Pay with IndiaMART
Tell us what you need, and we’ll help you get quotes
terms privacy policy