Three Phase-Single CT
Get Latest Price
Micro controller based DSP logic for measurements
All measurements with Class 1 accuracy
Input sensing either through line-to-line voltage with a CT or individual phase with a CT
Programmable external PT ratio for HT sensing
Voltage, Load I, Cap I THD measurement
Various modes of Programming step kvar, Unequal, binary, un-equal, C-series, E-series
RS232 OR RS485 port with TAS/MODBUS/GSM protocol in front facia for data-downloading / MODBUS connectivity / GSM connectivity
Protections provided: - Over/Under Voltage, Over/Under Load, Over/Under Cap. Current/THD, Load Unbalance, over temperature, Out-of-Steps indication
View Complete Details
Three Phase 3 CT
Get Latest Price
Suitable for three-phase sensing applications
Microcontroller based DSP logic for measurements
All measurements with Class 1 accuracy
Input sensing through line-to-line voltage with a CT. Programmable external PT ratio for HT sensing
Auto-synchronization capable of detecting wrong connections at CT terminals, even wrong CT polarity
Voltage, Load I, Cap I THD measurement with odd harmonic coefficient up to 15th harmonic (SPF-35)
Various modes of Programming step kvar, unequal, binary, C-series, E-series (SPF-35)
Protections provided: - Over/Under Voltage, Over/Under Load, Over/Under Cap. Current/THD, Load Unbalance, Over Temperature, Out-of-Steps indication
User-friendly PC software for data logging (Both) and GSM monitoring (SPF-35). Real Time Power Factor Correction Controllers (RTPFC) offers a complete solution for Automatic Power Factor Correction employing thyristor based switching of capacitors
RTPFC ensures Quick Response Time (of a few electrical cycles) enabling Real time Power factor correction in critical industrial conditions. It reduces Transmission Distribution (TD) losses, minimizes Peak or Maximum Demand (MD) in power consumption and maintains power factor close to unity (1.00)
View Complete Details
Single Phase Single CT
Get Latest Price
Suitable for Single-phase sensing applications
Microcontroller based DSP logic for measurements
All measurements with Class 1 accuracy
Input sensing through line-to-line voltage with a CT. Programmable external PT ratio for HT sensing
Auto-synchronization capable of detecting wrong connections at CT terminals, even wrong CT polarity
Voltage, Load I, Cap I THD measurement with odd harmonic coefficient up to 15th harmonic (SPF-35)
Various modes of Programming step kvar, unequal, binary, C-series, E-series (SPF-35)
Protections provided: - Over/Under Voltage, Over/Under Load, Over/Under Cap. Current/THD, Load Unbalance, Over Temperature, Out-of-Steps indication
User-friendly PC software for data logging (Both) and GSM monitoring (SPF-35). Real Time Power Factor Correction Controllers (RTPFC) offers a complete solution for Automatic Power Factor Correction employing thyristor based switching of capacitors
RTPFC ensures Quick Response Time (of a few electrical cycles) enabling Real time Power factor correction in critical industrial conditions. It reduces Transmission Distribution (TD) losses, minimizes Peak or Maximum Demand (MD) in power consumption and maintains power factor close to unity (1.00)
View Complete Details
HT Power Factor Controller
Get Latest Price
We offer the trouble free automated power factor control system at 11/33 kv. The system also protects the power factor from leading the desired value.
Depending on the load pattern the autorecloser automatically adjust the capacitor bank switching. The power factor can be controlled based on the desired value of current and power factor. The feedback at reclosure is provided by Current relay/APFC relay.
A current sensing relay is connected to CT which gives the feedback to the reclosure depending on the load variation. The reclosure in turn control the switching of the capacitor bank depending upon the desired value of the current.
An apfc relay is also provided in the system . this relay directly monitors the power factor and accordingly gives the feedback to the reclosure for controlling the power factor.If the pf is lagging the desired value ,then ht capacitors are automatically switched ON.
Intelligent KVAR based switching
Friendly user interface
Easy to install
Available in 4 to 16 stages (available stages 4 ,6 ,8,12,,14,16)
Accuracy Class 1
Switching Program: Intelligent (Best fit )
HT CT sensing for HT applications
View Complete Details