Fire Security Systems
We have for our clients a wide range of fire and security systems that are used in different industries. Further, our range is offered at competitive prices and delivered within the desired schedule time. Our range include:
|
|
Surveillance System
We offers the complete range of video surveillance system with closed circuit television (CCTV) cameras positioned in strategic locations. This is a system whereby we have a visual monitoring of different areas with add on sound features to get output on PC, TV or dedicated monitor. As per the requirements at site, we have to select different types of cameras and lenses. The visual display can also be recorded on time lapse VCR's and PC's which serves as an evidence for future analysis. Advanced systems also employ motion detection algorithms for automatic detection and recording thus incorporating intrusion detection with surveillance. The surveillance system consists of cameras, lenses, multiplexers, switchers, monitors, time lapse recorders & other accessories.
The cameras are connected through switchers and multiplexers to a bank of monitors in a central location. Selected areas in the field of view of the cameras can be viewed remotely from the central monitor. Cameras can be provided with pan tilt zoom units to allow the security staff to get a close up view of the area under surveillance. The video output can be recorded on to an external VCR or to a digital recording system. For medium and large installations, we provide surveillance system which works efficiently and economically. The enterprise building integrator provides a powerful facility of viewing live video image in the same screen as graphics on the PC monitor. This can be integrated with alarms in the system to provide the operator with a powerful tool to immediately view the affected area.
Security video can also be now sent across a local area network so that the system can be monitored remotely. For small and medium installations, we provide a wide range black & white, color cameras with suitable lenses and other peripherals. This product range is offered through a dedicated group within the company called ' total security solutions'.
 | |  |
|
|
Fire Extinguishers
We supply ISI mark fire extinguishers & also undertake refilling of the same. The types which we supply are ABC type, DCP type, water CO2 & CO2 type. Also we supply fire blankets & fire buckets. Fire hydrants are most commonly used water-based suppression systems for general fire fighting requirements. Automatic water sprinklers are used where quicker responses are required. Automatic gas-based systems are used to protect expensive industrial equipments. CO2 and FM200 are commonly used fire extinguishing gases. Larger applications also employ foam based suppressions techniques. Vedant Systems promotes the appropriate usage of these systems for greater risk coverage and minimum damages due to a hazard.
|
|
|
|
Rodent Repeller
Introducing the all new rodent repeller in advanced technology. This revolutionary pest control unit turns your office into a fortress against rodents. A high pressure transducer puts out an ultrasonic sound that is unmatched by other repellers. It utilizes the latest in ultrasonic technology. High pressure transducer emit a powerful ultrasonic sound that normal speakers can't. Unheard by humans or pets these sounds pond the ear drums of the small offensive critters called rodents. Much like a loud siren the sound intermittently attack the pests to drive them out. We uses a variable high frequency ultrasound (Above 20 kHz) so that pests do not get accustomed, the pest will leave the area being protected immediately or it will take as long as four to six weeks before these is a significant reduction in infestation. We transducer work silently, humans can't hear them so there is no discomfort. Human can't hear ultrasound but for rodent its like a loud police siren blasting all 24/7. It will drive them crazy. The panels are manufactured to the highest quality standards to meet the most stringent and diversed requirements. The panels are cost effective, reliable, easy to install & operate. This is supported by comprehensive documentation on commissioning, operating, maintenance & faultfinding. Features:
- Upto 15 transducers can be connected to main console.
- Transducers are looped in parallel thereby large reduction in cabling cost.
- Only two terminals for 15 transducers, easy to install and service.
- Self testing facility of transducers
- Wall mounted consoles
- Compacts elegant looks
- User friendly controls
 | |  |
|
|
Access Control System
We offers integrated and standalone access control system solutions for unmanned control of movement of employees and visitors.
- Access control system consists of card readers, door locks, cards and controllers. A variety of card reader technologies are supported which provides the flexibility to tailor the system to user's security needs. Card reader technologies include magnetic stripe, wiegand, proximity and biometric (like finger scan, face recognition, hand geometry etc.). For added security personal identification number (PIN) pads can be integrated with or located next to the card readers.
- For medium and large installations, Tata Honeywell's access control system provides variety of card readers, controllers and central operating workstation. The access control system database is used by security personnel to identify who is where, in case of emergencies like fire conditions etc. The access control system database can be used by human resources department for payroll and other purposes. The access control system database can be interfaced to building management systems for zone wise control of lighting and air conditioning equipment depending on the occupancy, to reduce energy wastage. Interfacing the access control system on LAN/WAN, central monitoring and single database of people working in multi- locational facilities is possible.
- For small and medium installations, we provide standalone access control system with proximity card readers, door control modules and controllers utilizing the power of LonWorks net working technology.
 | |  |
|
|
|
|
Fire Alarm System
Fire alarm system solution consists of detectors, devices, manual cell points, hooters, alarm panel, etc. These detectors & devices are located strategically across the area being protected and connected to a fire alarm panel. In the event of an outbreak of fire the following typical actions are performed by the system:
- Broadcast alarm tone, voice messages through emergency voice evacuation system
- Actuate dampers for smoke control
- Switch off AHUs to prevent spreading of smoke to adjacent areas
- Recall of elevators to zero level for assisting fire fighting personnel
- Intelligent analogue addressable fire alarm system provides individual addressing of each detector by the control panel to enable pinpointing of the fire source.Various types of detection technologies are available in the form of ionisation smoke detectors, photoelectric smoke detectors, heat detectors, multi sensing detectors, etc. Devices such as monitor modules, control modules and isolator modules are used to connect manual call points, isolators, etc. color graphic P.C. workstation with drop down menus and user-guided commands provides user friendly man-machine interface for monitoring, controlling and maintaining the system
- Conventional fire alarm system solutions are available for 4 and 8 zones. In addition to the main control unit the system is supplemented by the ability to add up to 3 remote keypads. Features such as built-in head removal monitoring, optional non-latch zones, class change inputs, zonal fire outputs and auxiliary supplies make the system ideal for most installations. With a 4 digit password, zones can be individually isolated or put into test mode with simple buttons
 | |  |
|
|
Video Capture Card
Our company is into supplying GV-900 video capture card for various industries like automobile, finance, I.T, civil, banking, residential companies and many more. This is a kind of computer expansion card which permits the computer to receive record video, television signals, playback video content. Along with this card we even provide 1/ 8 cams and 9/ 16 cams video audio cables. Following are the technical specifications of our products which ensure its technical efficiency:
Specifications:
| Input Type |
DB15 X 2 |
| Video Input(s) |
8,16 Cams |
| Audio Input(s) |
4 channels |
| Recording Rate |
240 fps(NTSC),200fps(PAL) |
| Display Rate |
240 fps(NTSC),200fps(PAL) |
| Video Resolution |
320x240, 640x240, 640x480, 640x480sw |
| Compression Format |
Wavelet, MPEG-4, GeoMPEG-4 |
| GV-DSP Support |
Yes |
| GV-A16 Support |
Yes |
| Dimension |
198mm x 104mm |
System Requirements:
| OS Supported |
Windows 2000 / Windows XP |
| CPU |
Pentium4-2.4GHz, 800 MHz FSB (minimum) |
| RAM |
2* 256 MB DDR-400 RAM (minimum) |
| HDD |
120GB (recommended) |
| VGA |
nVIDIA GeForceII MX 200 64MB |
 | |  |
|
|
|
|
Digital Video Recorder
A DVR which stands for digital video recorder (DVR) or personal video recorder (PVR) is a kind of device that records video in a digital format to a disk drive or any other kind of medium. The term involves stand-alone set-top boxes and software for personal computers enabling video capture and playback to and from disk. Along with our DVR, we provide 1/ 8 cams video audio cable and 9/ 16 cams video audio cable.
|
|
Clean Agent Systems
In response to the impending production phase out of halon fire extinguishants, we offers FM - 200 clean agents systems (Heptafluoropropane) as a replacement for Halon 1301 in applications requiring a clean, environmentally acceptable fire extinguishing agent, suitable for use in manned areas. It is a colourless gas at standard conditions. Through the use of properly designed equipment, FM-200 will mix well in a protected enclosure to provide a homogenous mixture in air. For fire suppression applications, FM-200 is super-pressurized to achieve rapid discharge into the protected environment. Technical specifications :
| Chemical Formula |
C3F7H |
| Ozone Depletion Potential |
0 |
| Molecular Weight |
170.03 |
| Extinguishing Concentration |
Cup 5.8% |
| Burner |
(% by volume) |
| Vapour Pressure at 21 |
68.8 psia |
How Fm-200 Works:
In order for a fire to be sustained, the three components fuel, oxygen and heat, must be present in sufficient quantities, and at sufficient levels. If one of the three elements is removed the fire will be suppressed. FM-200 works by physical action, the molecules absorb heat so that the temperature of the flame falls to a point below which it cannot propagate, and the fire is extinguished. The oxygen depleting effect is minimal as only small quantities of the gas are used. Introducing The Fm 200 Engineered Systems:
The combination of extinguishant and advanced system components offered by us is considered to be the ultimate gaseous system for a multitude of applications. These systems are individually designed for each customer's requirement utilizing an approved design manual and hydraulic calculations package.
- Individually tailored to meet exact requirements
- Efficient use of extinguishant
- Cost-effective use of pipe work, layout and materials
- Effective protection
 | |  |
|
|
|
 |
 |
 |
 |
 |