Share:  

Vijay Kr. Sanjeev Kr. Electricals
Vijay Kr. Sanjeev Kr. Electricals




Home

About Us

Products

Contact Us

Enquiry

Home » Products » Switch Gear


Switch Gear

We are among the major manufacturers of low voltage Switchgear.  Providing top quality equipment and parts,Switchgear provides shop, field and engineering services for power distribution equipment, including maintenance, quality testing and disaster recovery. Our product ideally suited for proper/efficient utilization of standby generator used in multi-storied apartments, commercial complexes, etc

 



Accl


Accl

the power instability in developing countries along with the inefficient rationalized power distribution creates a need for the alternative source of power, to back up the utility supply. This further necessitates the automation, in the distribution system as the rate of power outage & low voltage output becomes predominantly high. Most of the residential & commercial processes are dependent on power supply & if the process of changeover is manual, this will not only create the hindrance in important activities but it may also damage the device or machine from human error during the changeover.
havells accl is a fully automatic high precision microcontroller based device having current limiting function providing on both generator supply & mains supply and is ideally suited for proper/efficient utilization of standby generator used in multi-storied apartments, commercial complexes, etc.

technical specifications
standard conformity : iec 60947-6 /iec 60947-3 / is 13947-3
no. Of poles : 1p+n
rated current (in) : 30a on mains,3-20a on generator
rated voltage (ue) : 240 vac
operational voltage : 80-300vac
restoring time : 10 sec
dielectric strength : 2. 0kv
utilization category : ac 21a (iec 60947-3) / ac 31b (iec 60947-6)
indication : mains, generator, load, overload
ambient temp. : -5 to +55°c
electrical life : 6000 operations
pollution degree : 2
conditional short : 3ka circuit breaking capacity
protection class : ip20
mounting : standard mounting rail (35x7. 5 mm)
mounting position : vertical /horizontal
terminal capacity mm² : 10
weight : 350 gms.

features
• microcontroller based din rail mountable automatic source changeover with neutral isolation
• inbuilt smps for low power consumption
• operational status indication through leds
• manual reset provision for restoring supply, when in sleep mode
• automatic generator on/off facility (on special demand)
• staggered terminal design with bottom wiring for better isolation between phase & neutral

Changeover Switch


Changeover Switch

MCB Changeover switch finds wide & varied application in industries as well as in domestic sphere for use in low voltage distribution circuits, wherever continuity of supply is necessary, for switching to an alternate source of supply from main supply and vise-versa.

They are switch disconnectors with independent manual operation, capable of making, carrying and breaking currents under normal circuit conditions, which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for a specified time.

Range :
25A & 40A

Execution :
Double Pole (2P)
Four Pole (4P)

Specification



Features:
Compact construction
Double break contacts
Silver Cadmium Oxide contact tips
Shrouded terminals
Front operation with three stable positions I-O-II
Centre position off
Easy snap on DIN Rail mounting
Can be mounted with other products viz. MCB, ELCB, Isolator in   Distribution Board

IS 13947 - 3 / IEC 60947 - 3

Residual Current Circuit Breaker


Residual Current Circuit Breaker

The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical device cause currents to flow through the wrong path (i.e., through the insulation) to the earth. This current is called 'Leakage Current'.

Earth Leakage is an electrical hazard and is responsible for electrical shocks and fire risk. Earth Leakage and its associated hazard can be prevented by residual current circuit breaker (RCCB), also popularly known as Earth Leakage Circuit Breaker (ELCB).

Range :
16A to 63A

30mA, 100mA, 300mA

Specification :


Execution :
Double Pole (2P)
Four Pole (4P)

Features :
Simple and Robust operating mechanism.
Rotary handle with ON/OFF indication
Dual termination for Bus Bar as well as cable connection
Advance Neutral.
Test Button for regular inspection.
Positive contact indication.

IEC 61008 - 1/IS 12640 - 1: 2000

 

 

Effect of Electric current through human body has been well researched and following chart summarizes the result.

Indicator Light


Indicator Light

Havells Indicators Lights is new addition to the product range and can be used in both building and indutrial installation, Indicator Lights are designed fot signaling the incoming supply.

Technical Specification :

Specification

IS 13947 (Part 5)

 

Contacts

Rated Operation Voltage

240vac

Rating Electrical Power

1.0 Watt

Frequency

50 Hz

Type of lamp socket

E-10 Thread

Terminal Capacity

10mm2

Light Indications

Colour

 

 

Light

Permanent

 

Source

Neon Lamp

Other Data

Mounting on DIN Rail

35mm width

 

Degree of Protection

IP20

 

Ambient Temprature

-5 to 55° C


Application :
Distribution Box
Three Phase Tier DB
Kiosks
Load Line DB
Meter Boxes
Testing Panels
Switch Boards
MIMIC Panels
Control Panels

Features :
Modular Design enables Indicator lamp replacement with lens of diffrent   variants.
Very simple installation and replacement of the Indicator Light by the   customer.
Easy mounting on DIN rail 35.5X7.5mm.
Long Lifetime.
Available in five diffrent colours: Red, Amber, Blue, Green, Clear

Isolator


Isolator

They are Switch Disconnectors with independent manual operation,capable of marketing,carrying and breaking currents under normal circuit conditions,which  may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for a specified time

 

Range:

40A-63A, 80A- 125A

 

Execution:

Single Pole (1P)
Double Pole (2P)
Three Pole (3P)
Four Pole (4P)
Four Pole (2 Module)

 

Specification:

 

IS 13947 - 3 / IEC 60947 - 3

 

 

Features:

low Watt Loss
Longer Eletrical Life
Wide Range
Value for Money
Low power consumption,thus cost effective & energy saving









Contact us

Mr. S. K. Aggarwal (Proprietor)
No. 1822-A/5, Bhagirath Palace, Chandini Chowk
New Delhi, Delhi - 110 006, India
Telephone:  +(91)-(11)-23874161/ 66301517



Home  |  About Us  |  Products  |   Media Gallery  |  Site Navigation  |  Contact Us  |  Enquiry

Member IndiaMART.com © Vijay Kr. Sanjeev Kr. Electricals. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry