Showcase
View all our products / services as a slide show.
 |
 |
Our company is engaged in offering a wide collection of Hardness Testers to our valued clients. These Testers are made under the able guidance of our experts and they made these products with regular quality checks and are lab tested for maintaining the accuracy and quality of these products. These Testers are available in reasonable rates. The category includes:- - Metal Hardness Tester
- Surface Hardness Tester
- Hardness Tester Equipment
- Hardness Scales
|
| Metal Hardness TesterItem Code: TH-160 Being the eminent manufacturer, exporter and supplier of Hardness Testers, now offering a wide range of Metal Hardness Tester to our valued clients. These Testers are fabricated with high grade metals and these metals are procured from the reliable vendors in the market. These Testers are well tested by our experts who are totally experienced in this field. We provide quality products in affordable rates. The features of these are:- - Superior quality
- High efficiency
- Easy maintenance
Specifications:
| Hardness scale | HL, HRC, HRB, HV, HB, HS | | Memory | 240-1000 groups (Impacf times: 32-1) | | Measuring range | See next page | | Tensile strength U.T.S. range | 374-2652 fvlPa | | Accuracy | ± 6HLD (760 ± 30HLD) error of displayed value 6HLD (760 ± 30HLD) repeatability of displayed value | | Statistics function | Average / Max / Min value calculation, limits setting and alarm | | Standard Impact Device | D | | Optional Impact Devices | DC/DUC/D+15/G (see page 8) | | Max. Work piece Hardness | 996HV(For Impact Devices D/DC/DL/D+15/C) 646HB(For Impact Device G) | | Min. Radius of Workpiece (convex/concave] | Rmin = 50mm (with support ring Rmin= 10mm) | | Min. Workpiece weight | 2~5kg on stable support 0.05~2kg with compact coupling | | Min. Workpiece thickness | 5mm (Impact Device D/DC/DL/D+15) 1mm (Impact Device C) 10mm (Impact Device G) | | Mm. thickness of hardened Surface | 0.8mm | | Power | Rechargeable Li Battery, pile for TH160 | | Continuous Working time | About I00h (no printing and backlight) | | Charging time | 2.5-4 hours | | Operating temperature | 0~40'C | | Relative humidity | < 90% | | Overall dimensions | 230 x 90 x 46.5mm | | Weight | 420g (including Impact Device and printer) | |
Surface Hardness TesterItem Code: TH-130 Surface Hardness Testers are one of the demanded products of our company. We have dedicated and experienced team of professionals, who never compromises in the quality of the product and they conduct regular quality check sessions at each level of manufacturing process in order to provide effective and faultless products to our valued clients. These Testers are available in superior quality. The features of these are:- - High functionality
- Easy to use
- Requires low maintenance
Specifications:
| Standard Impact Device | D integrated | | Hardness scales | HLD, HB, HRC, HRB, HRA, HV, HS | | Measuring range / materials | See table above | | Accuracy | ± 6HLD(760 ± 30HLD) | | Memory | 99 average readings | | Output | RS232 to printer | | Min. Surface Roughness of Workpiece | 1.6 p m ( Ra) | | Max. Work piece Hardness | 900HLD | | Min. radius of Workpiece (convex/concave) | Rmin = 50mm( with support ring Rmin= 10mm) | | Min. Workpiece weight | 2~5kg on stable support 0.05~2kg with compact coupling | | Min. Workpiece thickness coupled | 5mm | | Min. Thickness of hardened layers | 0.8mm | | Indentation depth | Impact Devices data (See page 8) | | Continuous working time | 8h | | Power | Rechargeable Li-Polymer batteries | | Operating temperature | 0-40'C | | Overall dimensions | 155 x 24 x 55mm | | Weight | 180 g | | |
| Hardness Tester EquipmentItem Code: TH-134 Apart from these, we are also engaged in offering an extensive collection of hardness Tester equipments to our esteemed clients. These products are mainly used for testing the hardness of the equipment in an effective manner. These equipments are run with the use of electricity and consume low electricity. We also provide customized solutions as per the customer requirement. The features of these are:- - Highly demanded
- Durable
- Safe packaging
Specifications:
| Standard Impact device | DL integrated | | Hardness scales | HLDL.HB. HRC. HRB, HV, HS | | Measuring range / materials | See table above | | Accuracy | ±12HLDL | | Memory | 99 average readings | | Output | RS232 to printer | | Mim. Surface Roughness of Workpiece | 1.6 M m(Ra) Diameter = 2.8mm | | Needle front section of DL-device | Length = 50mm | | Max. Workpiece hardness | 950HLDL | | Min radius of Workpiece (convex/concave) | Rmin= 10mm | | Min. Workpiece weight | 2~5kg on stable support 0.05-2kg with compact coupling | | Min Workpiece. thickness coupled | 5mm | | Min. thickness of hardened layer | 0.8mm | | Indentation depth | Impact devices data (see page 8) | | Continuous Working time | 8h | | Power | rechargeable NiMH battery | | Operating temperature | 0-40'C | | Overall dimensions | 210X24X 55mm | |
Hardness ScalesItem Code: TH-170 Being the leading manufacturer, exporter and supplier of testing equipments, we are engaged in offering a wide collection of Hardness Scales to our esteemed clients. Our R&D Department is so much careful and conducts regular quality sessions at different level of manufacturing process in order to provide effective and faultless products to our valued clients. The features of these are:- - Reliable
- Easy to use
- Require low maintenance
Specifications:
| Standard Impact Device | D integrated | | Hardness scales | HLD, HB, HRC, HRB, HV, HS | | Measuring range / materials | See table above | | Measuring derection | 360° | | Accuracy | ± 6HLD(760 ± 30HLD) ± 10HI_D(530 + 40HLD) | | Memory | 270 average readings in 9 group files | | Output | USB2.0 | | Min. Surface Roughness of Workpiece | 1.6 u m(Ra] | | Max. Workpiece Hardness | 955HV | | Min. radius of Workpiece (convex/concave) | Rmin = 50mm {with support ring Rmin= 10mm) | | Min, workpiece weight | 2~5kg on stable support 0.05~2kg with compact coupling | | Min. Workpiece thickness coupled | 5mm | | Min. Thickness of hardened layers | 0.8mm | | Indentation depth | Impact Device data (see page 8) | | Continuous working time | 150h (without backlight) | | POWer | AAA 1.5V batteries (2pcs) | | Operating temperature | 0--40C | | Overall dimensions | 155mm x 55mm X 25mm | | Weight | About 166 g | | |
|