| Display Type | Digital |
| Model Name/Number | MS-70 |
| Heating Technology | Halogen lamp |
| Installation Type | Benchtop |
| Brand | A&D |
| Data Memory Function Type | 100 |
| Weight | 70g |
| Dimension | 215(W) x 320(D) x 173(H) mm |
| Interface | RS-232C standard |
| Operating Temperature | 40 deg C, less than 85% RH |
| Moisture Content Display | 0.05 % (over 1 g),0.01% (over 5 g) |
| Model | MS-70 |
| Brand Name | A&D |
| Sample Pan Size | 85 mm |
| Max Sample Weight Capacity | 71 g |
| Weight Resolution | 0.0001 g |
| Display | Large VFD |
| Heating Mode | Standard/Quick/Step/Ramp |
| Drying Temperature | 30-200 deg C |
| Automation Grade | Semi Automatic |
| Calibration | Manual |
Ideal for :
Food moisture analyzer, pharma moisture analyzer, plastic moisture analyser, plastic & resin moisture analyzer, plastic granules moisture analyzer, oil moisture analyzer, liquid moisture analyzer.
- Low moisture content measurement.
- Fast and uniform heating with halogen lamp and innovative Secondary Radiation Assist (SRA) technology.
- Accuracy verification with Sodium Tartrate Dihydrate.
- High repeatability with the Super Hybrid Sensor (SHS) technology.
- Calibration function for heating temperature.
- Five different measurement programs
- Selectable heating patterns
- Translucent window enabling progress check
- Memory function for measurement conditions
- Large bright Vacuum Fluorescent Display
- GLP/GMP/GCP/ISO compliant output
- Quick reference card provided.
View Complete Details
MS-70 Moisture Analyzer for Pharmaceutical Applications Analyzers
₹ 2,91,000/PieceGet Latest Price
Product Brochure Watch Video
| Display Type | LCD |
| Model Name/Number | MX50, MS-70 |
| Heating Technology | Halogen lamp (Straight type,400 Watt max,5000 hours) |
| Brand | A&D |
| Operating Temperature | 5-40 deg C, less than 85% RH |
| Power | AC 100 V to 120 V (3A) or AC 200 V to 240 V (1.5 A),50/60 Hz,Approx 400 W |
| Weight | Approx 6 kg |
| Data Memory Function Type | 100 |
| Interface | RS-232C standard |
| Moisture Content Display | 0.05 % (over 1 g),0.01% (over 5 g) |
| Measurement Method | 400W straight halogen lamp heating system with SRA filter and SHS weighing technology |
| Max Sample Weight Capacity | 71 g |
| Weight Resolution | 0.0001 g |
| Drying Temperature | 30-200 deg C |
| Memory of Measurement Programs | 20 sets |
| Measurement Mode | Moisture content(Wet or Dry base) /Dry content/Ratio/Weight |
| Heating Mode | Standard/Quick/Step/Ramp |
| Display | Large VFD |
| Sample Pan Size | 85 mm |
| Dimension | 215(W) x 320(D) x 173(H) mm |
| Automation Grade | Semi Automatic |
| Calibration | Manual |
| Measurement Programs | Standard Mode/Automatic Mode/Quick Mode/Timer Mode/Manual Mode |
Ideal for :
Food moisture analyzer, pharma moisture analyzer, plastic moisture analyser, plastic & resin moisture analyzer, plastic granules moisture analyzer, oil moisture analyzer, liquid moisture analyzer.
- Low moisture content measurement.
- Fast and uniform heating with halogen lamp and innovative Secondary Radiation Assist (SRA) technology.
- Accuracy verification with Sodium Tartrate Dihydrate.
- High repeatability with the Super Hybrid Sensor (SHS) technology.
- Calibration function for heating temperature.
- Five different measurement programs
- Selectable heating patterns
- Translucent window enabling progress check
- Memory function for measurement conditions
- Large bright Vacuum Fluorescent Display
- GLP/GMP/GCP/ISO compliant output
- Quick reference card provided.
View Complete Details
| Display Type | Digital |
| Heating Technology | Halogen lamp |
| Installation Type | Benchtop |
| Brand | A&D |
| Power | AC 100V to 120V |
| Weight | 6 kg |
| Dimension | 215(W) x 320(D) x 173(H) mm |
| Interface | RS-232C standard |
| Operating Temperature | 40 deg C |
| Moisture Content Display | 0.01%/0.1% |
| Brand Name | A&D |
| Display | Large VFD |
| Model Number | MX-50 |
| Moisture Content Accuracy | 0.10% (Over 1g),0.02% (Over 5g) |
| Weight Resolution | 0.001g |
| Drying Temperature | 200 deg C |
| Sample Pan Size | 85mm |
| Data Memory Function | 100 |
| Max Sample Weight Capacity | 51g |
| Automation Grade | Semi Automatic |
| Calibration | Manual |
Moisture Analyzer for Pharmaceutical Applications
Moisture Analyzer for Pharmaceutical Applications
Moisture Analyzer for Pharmaceutical Applications
Moisture Analyzer for Pharmaceutical Applications
Moisture Analyzer for Pharmaceutical Applications
Features:
- Low moisture content measurement at 10 ppm (0.001%) readability.
- Fast and uniform heating with halogen lamp and innovative Secondary Radiation Assist (SRA) technology.
- Accuracy verification with Sodium Tartrate Dihydrate.
- High repeatability with the Super Hybrid Sensor (SHS) technology.
- Calibration function for heating temperature.
- Five different measurement programs
- Selectable heating patterns.
- Translucent window enabling progress check.
- Memory function for measurement conditions.
- Large bright Vacuum Fluorescent Display.
- GLP/GMP/GCP/ISO compliant output
- Quick reference card provided.
View Complete Details
Moisture Analyzers For Food & Pharma
₹ 1,49,000/PieceGet Latest Price
| Display Type | Digital |
| Heating Technology | Halogen |
| Installation Type | Benchtop |
| Calibration | Manual |
| Brand | A&D |
| Temperature Compensation | Manual |
| Maximum Capacity | 80 g |
| Temperature Range | 30-200 degree c |
| Analysis Type | Moisture |
| Automation Grade | Semi Automatic |
Features
- Low moisture content measurement at 10 ppm (0.001%) readability (MS-70)
- Fast and uniform heating with halogen lamp and innovative Secondary Radiation Assist (SRA) technology
- Accuracy verification with Sodium Tartrate Dihydrate (standard with MS-70, MX-50, and MF-50)
- High repeatability with the Super Hybrid Sensor (SHS) technology
- Calibration function for heating temperature (for MS-70 and MX-50 only)
- Five different measurement programs
- Selectable heating patterns
- Translucent window enabling progress check
- Memory function for measurement conditions
- Large bright Vacuum Fluorescent Display
- GLP/GMP/GCP/ISO compliant output
- Quick reference card provided
View Complete Details
| Display Type | Touch Screen |
| Heating Technology | Halogen |
| Automation Grade | Fully Automatic |
| Installation Type | Benchtop |
| Calibration | Automatic |
| Brand | A&D |
| Temperature Compensation | Automatic |
| Maximum Capacity | 80 g |
| Temperature Range | 30-200 degree c |
| Analysis Type | Moisture |
| MS-74A(T) / MX-53A(T) / MF-53A / ML-53A | ||||||||
| Heat-Drying Moisture Analyzers | ||||||||
|
||||||||
|
|
||||||||
|
||||||||
| Features | ||||||||
| Simple, safe, and chemical reagent-free heat-drying technology Six models available: From high-end touchscreen models (MS-74AT/MX-53AT) to cost-effective reverse backlit LCD models Optimum Temperature Search (RsTemp) for quickly identifying recommended drying temperature Powerful 400 W halogen lamp for high-speed heating Secondary Radiation Assist (SRA) for even heat distribution and lamp protection Super Hybrid Sensor (SHS) ensuring high precision and reproducibility Heater cover with a soft-close design for operational comfort Automatic tare/measurement start upon cover closure*1 Preheating function for result consistency Real-time display of moisture content and drying rate (%/min) Offset adjustment (up to ±9.999%*2) for result alignment Weighing mode to use the analyzer as a balance Thermal analysis mode (up to five drying stages)*1 Programmed measurement: Save up to 300 customized conditions (200 for the reverse backlit LCD models) Over 100 preset programs (examples) Level meter providing visual guidance for accurate sample placement Sample mass calculation tool for calculating required sample weight for accurate moisture measurement*1 Sample pretreatment guide for displaying pretreatment recommendations based on sample characteristics*1 Automatic determination of drying time in Timer mode for estimating optimal drying duration at three accuracy levels*1 Plastic measurement guide for supporting measurements of low-moisture samples (1% or less)*1 Comparator function for evaluating moisture content with HI/OK/LO thresholds User access control (UAC) with user rights management and password lock functions Automatic storage of up to 3,000 measurement results (200 for the reverse backlit LCD models) Comprehensive history recording (adjustment, operation, log-in/out histories) Daily-check and self-check functions for stable operation Measurement accuracy verification using a standard test sample (sodium tartrate dihydrate) Adjustment functions for both the weight sensor and the heater GLP/GMP/GCP/ISO compliant output to meet documentation requirements Built-in Help menu and FAQ*1 Support for eleven display languages*1: English, French, German, Italian, Dutch, Spanish, Portuguese, Russian, Korean, Chinese, or Japanese *1 Available for the MS-74AT/MX-53AT (touchscreen models) only *2 Precision depends on the model’s readability. |
||||||||
View Complete Details
| Power | AC 100 V to 120 V (3A) |
| Data Memory Function Type | 100 |
| Heating Technology | Halogen lamp |
| Weight | 6 kg |
| Dimension | 215(W) x 320(D) x 173(H) mm |
| Interface | RS-232C standard |
| Operating Temperature | 5-40 deg C, less than 85% RH |
| Moisture Content Display | 0.05 % (over 1 g),0.01% (over 5 g) |
| Model | MS-70 |
| Brand Name | A&D |
| Sample Pan Size | 85 mm |
| Max Sample Weight Capacity | 71 g |
| Weight Resolution | 0.0001 g |
| Display | Large VFD |
| Drying Temperature | 200 deg C |
| Measurement Programs | Standard Mode/Automatic Mode/Quick Mode/Timer Mode/Manual Mode |
Ideal for :
Food moisture analyzer, pharma moisture analyzer, plastic moisture analyser, plastic & resin moisture analyzer, plastic granules moisture analyzer, oil moisture analyzer, liquid moisture analyzer.
- Low moisture content measurement.
- Fast and uniform heating with halogen lamp and innovative Secondary Radiation Assist (SRA) technology.
- Accuracy verification with Sodium Tartrate Dihydrate.
- High repeatability with the Super Hybrid Sensor (SHS) technology.
- Calibration function for heating temperature.
- Five different measurement programs
- Selectable heating patterns
- Translucent window enabling progress check
- Memory function for measurement conditions
- Large bright Vacuum Fluorescent Display
- GLP/GMP/GCP/ISO compliant output
- Quick reference card provided.
View Complete Details
| Display Type | Digital |
| Model Name/Number | MX50 |
| Heating Technology | Halogen lamp (Straight type,400 Watt max,5000 hours) |
| Brand | A&D |
| Installation Type | Benchtop |
| Maximum Capacity | 50 g |
| Power | AC 100V to 120V (3A) or AC 200V to 240V (1.5A),50/60 Hz,Approx. 400W |
| Temperature Range | 30-200 degree c |
| Analysis Type | Moisture |
| Weight | Approx. 6kg |
| Interface | RS-232C standard |
| Operating Temperature | 5-40 deg C (41-104 deg F) less than 85%RH |
| Moisture Content Display | 0.01%/0.1% |
| Model Number | MX-50 |
| Measurement Method | 400W straight halogen lamp heating system with SRA filter and SHS weighing technology |
| Max Sample Weight Capacity | 51g |
| Weight Resolution | 0.001g |
| Drying Temperature | 50-200 deg C |
| Memory of Measurement Programs | 20 sets |
| Measurement Mode | Moisture content(Wet or Dry base) /Dry content/Ratio/Weight |
| Heating Mode | Standard/Quick/Step/Ramp |
| Display | Large VFD |
| Data Memory Function | 100 |
| Sample Pan Size | 85mm |
| Dimension | 215(W) x 320(D) x 173(H) mm |
| Moisture Content Accuracy | 0.10% (Over 1g),0.02% (Over 5g) |
| Automation Grade | Semi Automatic |
| Calibration | Manual |
| Measurement Programs | Standard Mode/Automatic Mode/Quick Mode/Timer Mode/Manual Mode |
Features:
- Low moisture content measurement at 10 ppm (0.001%) readability.
- Fast and uniform heating with halogen lamp and innovative Secondary Radiation Assist (SRA) technology.
- Accuracy verification with Sodium Tartrate Dihydrate.
- High repeatability with the Super Hybrid Sensor (SHS) technology.
- Calibration function for heating temperature.
- Five different measurement programs
- Selectable heating patterns.
- Translucent window enabling progress check.
- Memory function for measurement conditions.
- Large bright Vacuum Fluorescent Display.
- GLP/GMP/GCP/ISO compliant output
- Quick reference card provided.
View Complete Details
| Model No. | MF-50 |
| Measurement Method | 400 W straight halogen lamp heating system with SRA filter and SHS weighing technology |
| Maximum sample weight capacity | 51 g |
| Drying Temperature | 50 to 200 C Degree |
| Measurement Unit | Wet base / Dry base / Dry content / Ratio / Weight |
| Sample Pan Size | 85 mm |
Features
- Low moisture content measurement at 10 ppm (0.001%) readability (MS-70)
- Fast and uniform heating with halogen lamp and innovative Secondary Radiation Assist (SRA) technology
- Accuracy verification with Sodium Tartrate Dihydrate (standard with MS-70, MX-50, and MF-50)
- High repeatability with the Super Hybrid Sensor (SHS) technology
- Calibration function for heating temperature (for MS-70 and MX-50 only)
- Five different measurement programs
- Selectable heating patterns
- Translucent window enabling progress check
- Memory function for measurement conditions
- Large bright Vacuum Fluorescent Display
- GLP/GMP/GCP/ISO compliant output
- Quick reference card provided
View Complete Details
| Model Name/Number | MS-74A(T) / MX-53A(T) / MF-53A / ML-53A |
| Automation Grade | Automatic |
| Display Type | Digital |
| Language | English |
| Features |
| Simple, safe, and chemical reagent-free heat-drying technology Six models available: From high-end touchscreen models (MS-74AT/MX-53AT) to cost-effective reverse backlit LCD models Optimum Temperature Search (RsTemp) for quickly identifying recommended drying temperature Powerful 400 W halogen lamp for high-speed heating Secondary Radiation Assist (SRA) for even heat distribution and lamp protection Super Hybrid Sensor (SHS) ensuring high precision and reproducibility Heater cover with a soft-close design for operational comfort Automatic tare/measurement start upon cover closure*1 Preheating function for result consistency Real-time display of moisture content and drying rate (%/min) Offset adjustment (up to ±9.999%*2) for result alignment Weighing mode to use the analyzer as a balance Thermal analysis mode (up to five drying stages)*1 Programmed measurement: Save up to 300 customized conditions (200 for the reverse backlit LCD models) Over 100 preset programs (examples) Level meter providing visual guidance for accurate sample placement Sample mass calculation tool for calculating required sample weight for accurate moisture measurement*1 Sample pretreatment guide for displaying pretreatment recommendations based on sample characteristics*1 Automatic determination of drying time in Timer mode for estimating optimal drying duration at three accuracy levels*1 Plastic measurement guide for supporting measurements of low-moisture samples (1% or less)*1 Comparator function for evaluating moisture content with HI/OK/LO thresholds User access control (UAC) with user rights management and password lock functions Automatic storage of up to 3,000 measurement results (200 for the reverse backlit LCD models) Comprehensive history recording (adjustment, operation, log-in/out histories) Daily-check and self-check functions for stable operation Measurement accuracy verification using a standard test sample (sodium tartrate dihydrate) Adjustment functions for both the weight sensor and the heater GLP/GMP/GCP/ISO compliant output to meet documentation requirements Built-in Help menu and FAQ*1 Support for eleven display languages*1: English, French, German, Italian, Dutch, Spanish, Portuguese, Russian, Korean, Chinese, or Japanese *1 Available for the MS-74AT/MX-53AT (touchscreen models) only *2 Precision depends on the model’s readability. |
View Complete Details
| Display Type | Digital |
| Heating Technology | Halogen |
| Installation Type | Benchtop |
| Brand | A&D |
| Weight | 0.005 g |
| Model | ML-50 |
| Maximum sample weight capacity | 51 g |
| Drying Temperature | 50 to 200 C Degree |
| Sample Pan Size | 85 mm |
| Measurement Method | 400 W straight halogen lamp heating system with SRA filter and SHS weighing technology |
| Automation Grade | Semi Automatic |
| Calibration | Manual |
Features
- Low moisture content measurement at 10 ppm (0.001%) readability (MS-70)
- Fast and uniform heating with halogen lamp and innovative Secondary Radiation Assist (SRA) technology
- Accuracy verification with Sodium Tartrate Dihydrate (standard with MS-70, MX-50, and MF-50)
- High repeatability with the Super Hybrid Sensor (SHS) technology
- Calibration function for heating temperature (for MS-70 and MX-50 only)
- Five different measurement programs
- Selectable heating patterns
- Translucent window enabling progress check
- Memory function for measurement conditions
- Large bright Vacuum Fluorescent Display
- GLP/GMP/GCP/ISO compliant output
- Quick reference card provided
View Complete Details
- Developed and Managed by IndiaMART InterMESH Limited