- Liquid Particle Counter LiQuilaz II Series
- TrackSense LyoPro Wireless Data Logger
- Liquid Particle Counter Ultra DI
- Liquid Particle Counter for USP 788 APSS-2000
- Lasair Pro Particle Counter
- Remote Particle Counter : IsoAir Pro
- 01 Micron Particle Counter Lasair III 110
- Deionized Water Particle Counter HSLIS-M50e
- Microbial Air Sampler MiniCapt Mobile
- Syringe Sampling System
- Remote Air Sampler MiniCapt
- Handheld Particle Counter Handilaz Mini II
- Viable Cleanroom Monitor BioCapt Impactor
- Airborne Particle Counter Lasair Pro
- TrackSense Pro Reader Station
- Wireless Data Loggers TrackSense
- Airnet II / IIs Particle Sensor (2 Channel)
- Temperature Calibrator
- Airnet II / IIs Remote Particle Sensors (2 Channels)
- Bioreset Vapour-Phase Hydrogen Peroxide (V-PHP) Generator
Contamination Control
Liquid Particle Counter LiQuilaz II Series
Get Latest Price
| Particle Counter Type | Liquid |
| Brand | Particle Measuring Systems |
| Usage/Application | Laboratory |
| Size | Dimensions (l, w, h) 12.75 x 4.25 x 4.5 in |
| Channels | User adjustable sizing |
| Sample Temperature | 32 - 302 DegreeF (0 - 150 DegreeC) |
| USP | 788-1788 compliance with the SLS sampler family |
The LiQuilaz® II liquid particle counter Series comes in a range of sizing sensitivities to meet your volumetric liquid particle counting needs. It provides high-precision analysis for most process chemicals, including hydrofluoric acid and hot corrosive chemicals up to 306 °F (152 °C). Liquilaz II S Series – sensitivity range: 0.2 – 20 µm
Liquilaz II E Series – sensitivity range: 1.5 – 125 µm
View Complete Details
| Power Supply | Battery Operated |
| Model Name/Number | TrackSense LyoPro |
| Accuracy | +- 0.3 DegreeC |
| Temperature Measuring Range | -62 to +62 DegreeC |
| Calibrated Temperature Range | -60 to +60 DegreeC |
| Usage/Application | Data Logger for Freeze Drying |
| Memory Capacity | 100.000 samples |
Ellab’s new TrackSense® LyoPro data loggers – the ultimate solution for lyophilization. LyoPro is designed to revolutionize the validation and monitoring of your critical freeze drying process. Whether this is for validating the process, temperature mapping the equipment or batch control.The LyoPro is a specially designed data logger for complete batch control and validation of the freeze drying processes. The tiny data logger fits perfectly within any lyophilization setup, as the various LoggerNests allow the device to match the size of any vial.LyoPro comes fitted with an 0.55 x 0.95 mm thermocouple sensor that ensures next to no impact on the sample during measurements, thereby providing highly valid data.Data integrity is at its finest with TrackSense LyoPro. The internal data logger memory constantly stores every sample, allowing the ValSuite software to provide a complete picture of the process, without you ever having to worry about gaps in data.
View Complete Details
Liquid Particle Counter Ultra DI
Get Latest Price
| Particle Counter Type | Liquid |
| Brand | Particle Measuring Systems |
| Usage/Application | Laboratory |
| Material | Stainless Steel |
| Model Name/Number | Ultra DI 20 |
| Sensitivity | Range: 20 - 100 nm |
| Application | Laboratory water sampling WFI and Purified Water testing |
The Ultra DI line of DI water particle counters from Particle Measuring Systems (PMS®) provides groundbreaking capabilities for monitoring the most demanding de-ionized and ultrapure water systems.
View Complete Details
Liquid Particle Counter for USP 788 APSS-2000
Get Latest Price
| Model Name/Number | APSS-2000 |
| Brand | Particle Measuring Systems |
| Usage/Application | Laboratory |
| Material | Chemical-resistant polycarbonate |
| Application | Pharmaceutical liquid particle batch sampling |
| Flow Rate | 20 ml/min |
The APSS-2000 Liquid Particle Counter for USP 788 sizes and counts suspended particulate matter in a wide range of liquids, including parenteral, to meet all current U.S., European and Japanese Pharmacopoeia standards. When it comes to particle monitoring quality control for liquid drug manufacturers, it’s important to meet regulations while minimizing waste.
Along with USP 788 for particles in liquids, the APSS-2000 Particle Counter has recipe functions that allow it to adapt to future regulatory changes, and its small sample volume minimizes the waste of expensive products.
The APSS-2000 Liquid Particle Counter includes an SLS-1000 Syringe Sampler, a LiQuilaz® E Series Light Obscuration Spectrometer and SamplerSight Pharma Software, allowing reports to meet 21 CFR 11 regulations for electronic records and signatures.
Additional Information:
- Item Code: APSS2000
View Complete Details
| Particle Counter Type | Air |
| Brand | Particle Measuring Systems |
| Usage/Application | Laboratory |
| Model | LASAIR Pro |
| Material | Chemical-resistant polycarbonate |
| Application | Laboratory |
| Flow Capacity Range | 100 LPM, 50 LPM, or 1 CFM |
| Iso Certified | ISO 14644 |
The Lasair Pro particle counter is the standard in cleanroom monitoring with its portability and high-accuracy ensuring cleanroom compliance. With real-time information at your fingertips, the Lasair Pro delivers accurate data that is easy to export and manage.
View Complete Details
Remote Particle Counter : IsoAir Pro
Get Latest Price
| Particle Counter Type | Air |
| Brand | Particle Measuring System |
| Usage/Application | Laboratory |
| Material | Stainless Steel |
| Air Flow | Flow rate 1CFM |
| Model Name/Number | IsoAir Pro |
| Application | Cleanroom monitoring |
Ensure Compliance Flow rate 1CFM Real-time Remote Particle Counter: IsoAir® Pro. Sensitivity range: 0.3 - 25.0 µm; 1.0 CFM (28.3 LPM) - Built-in vacuum, PoE, VHP resistant
View Complete Details
01 Micron Particle Counter Lasair III 110
Get Latest Price
| Particle Counter Type | laser diode-based |
| Brand | Particle Measuring Systems |
| Usage/Application | Laboratory |
| Material | Stainless Steel |
| Model Name/Number | Lasair III 110 |
| Application | Clean room certification for class 1 and 2 cleanrooms |
| Range | 0.1 to 5 microns |
Lasair III 110 mobile particle counter: 0.1 micron particle counter can be used as a mobile counter to localize the source of particles, making this an ideal tool for ISO-14644-1 clean room certification for class 1 and 2 cleanrooms. Lasair III 110 inline particle counter: 0.1 micron particle counter is perfect for critical locations where continuous, uninterrupted 0.1 micron monitoring is needed. Making this an ideal application for continuous clean room monitoring, process tool monitoring, and filter testing.
View Complete Details
Deionized Water Particle Counter HSLIS-M50e
Get Latest Price
| Particle Counter Type | Liquid |
| Brand | Particle Measuring Systems |
| Usage/Application | Laboratory |
| Flow Capacity Range | 100 ml/min +- 10% |
| Sensitivity | 0.05 - 0.2 nm |
| Application | Provides continuous, real-time monitoring of contamination levels in DI water and process chemicals. |
| Channels | 4 |
The HSLIS liquid Particle Counter provides continuous, real-time particle monitoring of contamination levels in corrosive liquids, including hydrogen fluoride (HF) and is included in Particle Measuring System’ (PMS) complete line of liquid particle counters.
View Complete Details
Microbial Air Sampler MiniCapt Mobile
Get Latest Price
| Model Name/Number | MiniCapt Mobile |
| Usage/Application | It is used in continuous microbial monitoring |
| Brand | Particle Measuring Systems |
| Automation Grade | Automatic |
| Ref. Standards | ISO 14698:2003 |
EU GMP Annex 1 continuous viable monitoring solution and ISO 14698:2003 compliant. Simple to use. False positives can be easily identified.
View Complete Details
Syringe Sampling System
Get Latest Price
| Brand | Particle Measuring Systems |
| Model Name/Number | SLS 1040 |
| Shape | Square |
| Usage/Application | Liquid particle sampling & Laboratory water sampling WFI and Purified Water testing |
| Automation Type | Automatic |
| Flow Rate | 5 ml/min |
| Digital | Yes |
| Particle Size Range | 40 to 125 nm |
| Minimum Particle Size | 20 nm |
The SLS Syringe Liquid Particle Sampler from Particle Measuring Systems uses a precision syringe and simple flow-path for delivering chemical samples from a sample vessel or chemical container, directly to the particle sensor. It is ideal for applications where precise, small-volume particle batch sampling is required, where the sampler device cannot contribute contamination to the chemical sample.
The system consists of a selectable syringe for either corrosive or non-corrosive liquids, a selectable particle counter for different sizing sensitivities, and batch-sampling software.
View Complete Details
Remote Air Sampler MiniCapt
Get Latest Price
| Material | Stainless Steel |
| Brand | Particle Measuring Systems |
| Automation Grade | Automatic |
| Application | Microbial air sampling in cleanrooms and associated controlled environments |
| Operating environment | Temperature: 32 - 104 DegreeF (0 - 40 DegreeC); Humidity: 10 - 90% RH |
| Power supply | Input: 100 - 240 VAC, 50/60 Hz, 1.5 A |
VHP-resistant, Annex 1 compliant, self-contained, remote microbial air sampler with installation flexibility.
View Complete Details
Handheld Particle Counter Handilaz Mini II
Get Latest Price
| Model Name/Number | Handilaz Mini II |
| Brand | Particle Measuring Systems |
| Usage/Application | Laboratory |
| Flow Capacity Range | 0.1CFM flow rate |
| Iso Certified | ISO 21501-4 Standard |
| Application | Cleanroom or clean devices monitorinng,Spot monitoring and troubleshooting |
Handheld paricle counter with 0.1CFM flow rate with size range of 0.2 to 10 microns with unlimited size channels with 10nm resolution. Best suitable for semiconductor, sdvanced srocessing and pharmaceutical applications. Integration of temperature and differential pressure into particle
measurement. Calibrated to ISO 21501-4 Standard.
View Complete Details
Viable Cleanroom Monitor BioCapt Impactor
Get Latest Price
| Model Name/Number | BioCapt Impactor |
| Brand | Particle Measuring Systems |
| Usage/Application | Laboratory |
| Material | Stainless Steel |
| Iso Certified | Accordance with ISO 14698-1 |
| Application | Facility monitoring system for clean areas |
The biocapt impactor active microbial air sampling atrium enables the capture of microbiologically viable particulates on a suitable media surface for later incubation and enumeration. The slits in the biocaptimpactor are precision cut to ensure laminar flow, thus maximizing collection efficiencies for viable particles in accordance with iso 14698-1. Biological efficiency is guaranteed by ensuring optimal impaction velocity and giving statistical control over false positive results. The biocaptimpactor can be used in dedicated facility monitoring system (fms) applications as a standalone microbial sample collection device or in portable microbial monitoring applications in conjunction with a sampling device, such as the minicapt™ portable microbial sampler.
Benefits:
- Highest validated physical and biological collection efficiencies per ISO 14698-1/Annex B
- 316L stainless steel atrium is autoclavable
- Optimal slit design ensures that microorganisms are undamaged during sampling
- Immediate and easy detection of false positives
- Microbial air sampling in cleanrooms and associated controlled environments
- USP 797 environmental viable airborn particle testing
- Bioburden monitoring of medical device manufacturing environments
- Microbial monitoring of aseptic manufacturing areas
- Microbiological monitoring of surgical suites or operating rooms
- Clean Room
- Pharmaceutical & Bulk Drugs
View Complete Details
Airborne Particle Counter Lasair Pro
Get Latest Price
| Model Name/Number | Lasair Pro |
| Brand | Particle Measuring Systems |
| Usage/Application | Laboratory |
| Features | 21 CFR Part 11 compliant audit trail with 20,000 recorded activities |
| Power | Rechargable lithium ion batteries for portable use |
| Ref. Standards | FDA 21 CFR Part 11 and EU GMP Annex 11 |
Advanced particle counter with full contamination control solution including clean area monitoring to meeting global standards for data integrity. Size range of 0.3 microns to 25microns with user-selectable channels in the range. Lasair Pro is 21 CFR Part 11 compliant with audit trail recorded activities. 100 users on each instrument. With unique NFC card capabilities, unlimited users can operate with unique credentials. Single can store up to 10,000 data storage capabilities with 1,000 configurable locations organized by area, room, and location hierarchy.
View Complete Details
TrackSense Pro Reader Station
Get Latest Price
| Operating Temperature | 5 to 50 DegreeC |
| Operating Voltage | 5V External Adapter 100-240V AC, 50-60 Hz or USB |
| Environmental | 0-90% RH, Non-Condensing |
| Reader / Logger Communication | Induction |
| PC Interface | USB / LAN Connection |
| Capacity | 1-4 loggers at a time |
Ellab's TrackSense Pro Multi Reader Station is designed & engineered for versatility and speed. The station connects to the PC via USB and includes four logger positions. Power is supplied directly from the PC while utilising the USB port, eliminating the need for an external power source. Starting up and reading of dataloggers can now be performed in seconds. 16 loggers can be started or read simultaneously, saving time, especially when 160 data loggers have to be started in one study.
View Complete Details
Wireless Data Loggers TrackSense
Get Latest Price
| Usage/Application | contamination monitoring and validation |
The TrackSense® wireless data loggers are the most complete validation solution available today. With a wide range of measuring parameters, Ellab’s data loggers are ideal for most applications.
View Complete Details
| Brand | Particle Measuring Systems |
| Usage/Application | Laboratory |
| Material | Chemical-resistant polycarbonate or stainless steel |
| Air Flow | Flow rate 1.0 CFM |
| Model Name/Number | Airnet II / IIs |
Airnet Remote Particle Sensors: 2 Channels. As part of a facility monitoring solution, the Airnet® II and IIs Particle Sensors from Particle Measuring Systems meet the specifications of ISO 21501-4 to measure the size and number of particles suspended in the air for real-time monitoring of defect-causing particles.2-channels model for the 0.5 and 5.0 μm size range, suitable for Pharmaceutical application1.0 CFM flow rate. Communication with Modbus TCP IP. Standard POE for communication & power requirements. Although, optional 4-20 mA output (Polycarbonate version only). Available in chemical-resistant polycarbonate (PC) or Stainless Steel 316L enclosure. Optional XR coating protects sensors against corrosive or oxidizing vapours in VHP sterilization processes with Airnet II XR models.
View Complete Details
| Accuracy | + or - 0.04% |
| Model Name/Number | RTC Series |
| Temperature Range | -100 to 700 DegreeC (-148 to 1292 DegreeF) |
| Brand | AMETEK Denmark A/S |
| Use | Pharmaceuticals, food processing, and industrial manufacturing |
| Test Methods | DLC (Dynamic Load Compensation) technology |
Our temperature equipment includes dry-block and liquid bath calibrators, temperature indicators, industrial sensors, and reference sensors that can be used together for a complete temperature calibration solution. Included are 6 series of temperature calibrators with more than 25 models and ranges from -100 to 1205°C, fully traceable thermometers, smart temperature sensors, hand-held temperature indicators, and a bench top temperature indicator.
- •Reference Temperature Calibrator
•Professional Temperature Calibrator
•Compact Temperature Calibrator
•Easy Temperature Calibrator
View Complete Details
Airnet II / IIs Remote Particle Sensors (2 Channels)
Get Latest Price
| Model Name/Number | Airnet II / IIs |
| Usage/Application | Facility monitoinrg system for clean areas |
| Brand | Particle Measuring System |
| Flow Rate | 1.0 CFM |
| Material | Chemical-resistant Polycarbonate (PC) or Stainless Steel |
| Sensitivity | 0.3 - 5.0 nm |
Airnet Remote Particle Sensors: 2 Channels. As part of a facility monitoring solution, the Airnet® II and IIs Particle Sensors from Particle Measuring Systems meet the specifications of ISO 21501-4 to measure the size and number of particles suspended in the air for real-time monitoring of defect-causing particles.
2 channels model for 0.5 and 5.0 μm size range, suitable for Pharmaceutical application
1.0 CFM flow rate. Communication with Modbus TCP IP. Standard POE for communication & power requirements. Although, optional 4-20 mA output (Polycarbonate version only). Available in chemical-resistant polycarbonate (PC) or Stainless Steel 316L enclosure. Optional XR coating protects sensors against corrosive or oxidizing vapours in VHP sterilization processes with Airnet II XR models.
View Complete Details
| Technology | Biodecontamination |
| Generator Type | Vapour-Phase Hydrogen Peroxide |
| Usage/Application | Bio decontamination |
| Grade Standard | Chemical Grade |
| Brand | Amira, Italy |
| Material | Stainless steel AISI 316 and ABS |
| Power supply | 230V / 50Hz o 110V / 60Hz |
| Max consumption | 1 kW |
Bioreset solutions are mainly used to remove the airborne and surface microbiological contamination in controlled or classified environments for pharmaceutical, biomedical, biotechnological, animal care and in any other environment where microbiological contamination is a concern.
Based on the equipment model:
· Treated Volume upto 650 M3· Tablet Wi-Fi onboard
· Remote operation with any device
· Downloadable cycle report via USB Port
View Complete Details
Explore more categories