Products & Services
- Lasair III Particle Counter
- Remote Particle Counter IsoAir Pro Plus
- Liquid Particle Counter for USP 788 APSS-2000
- Viable Cleanroom Monitor BioCapt Impactor
- Deionized Water Particle Counter HSLIS-M50e
- Liquid Particle Counter LiQuilaz II S Series
- Liquid Particle Counter Ultra DI 20
- Microbial Air Sampler MiniCapt Mobile
- 01 Micron Particle Counter Lasair III 110
- Airborne Particle Counter Lasair Pro
- Handheld Particle Counter Handilaz Mini II
- Remote Air Sampler MiniCapt
- Syringe Sampling System
- Airnet II Particle Sensor (4 Channel)
- Airnet II / IIs Remote Particle Sensors (2 Channels)
Particle Counting
Usage/Application | Laboratory |
Material | Chemical-resistant polycarbonate |
Brand | Particle Measuring Systems |
Model | LASAIR III |
Application | Laboratory |
Flow Capacity Range | 100 LPM, 50 LPM, or 1 CFM |
Iso Certified | ISO 14644-1:2015 compliant |
Cleanroom particle counter meets the requirements of ISO 14644-1:2015, EU GMP Annex 1 and ISO 21501-4.
The Lasair® III Cleanroom Particle Counter is designed with your unique needs in mind. It sets the standard for portable aerosol particle counters in highly regulated environments, so you can make sure your environment is clean.
It can be used for both remote and mobile routine cleanroom monitoring. We know the requirements and we’ve done the calculations for you; cleanroom certification results are available through a local printout, downloadable via USB in a secure format, or through the use of external software packages, such as DataAnalyst, FacilityNet or FacilityNet Pharma Software.
View Complete Details
Remote Particle Counter IsoAir Pro Plus
Get Latest Price
Usage/Application | Laboratory |
Material | Stainless Steel |
Air Flow | Flow rate 1CFM |
Model Name/Number | IsoAir Pro-Plus |
Brand | Particle Measuring System |
Application | Cleanroom monitoring, Trend analysis, Statistical process control, Isolator particle counting |
Ensure Compliance Flow rate 1CFM Real-time particle monitoring gives quick notification 0.5 and 5.0 micron channels for GMP compliance Proven technology provides reliable and accurate data Identify breakdowns in critical zone protection Increase Productivity Low-cost solution for multi-location monitoring Alarm paging system allows immediate response to particle events Interfaces with optional Pharmaceutical or Facility Net software for comprehensive management of cleanroom conditions Validation documentation available Cost Effective Compact, complete particle monitor is easy to install, even within isolators Stainless steel isokinetic sample probe and cap easy to clean/wipe down Rugged, chemical-resistant, easy-to disinfect enclosure Passivated 316 stainless steel surface has well-defined microbial control characteristics Diode laser reduces maintenance requirements Special XR coating option protects sensor against corrosive or oxidizing vapors May extend your cleanroom classification period.
View Complete Details
Liquid Particle Counter for USP 788 APSS-2000
Get Latest Price
Brand | Particle Measuring Systems |
Usage/Application | Laboratory |
Material | Chemical-resistant polycarbonate |
Model Name/Number | APSS-2000 |
Application | Pharmaceutical liquid particle batch sampling |
Flow Rate | 20 ml/min |
The APSS-2000 Liquid Particle Counter for USP 788 sizes and counts suspended particulate matter in a wide range of liquids, including parenteral, to meet all current U.S., European and Japanese Pharmacopoeia standards. When it comes to particle monitoring quality control for liquid drug manufacturers, it’s important to meet regulations while minimizing waste.
Along with USP 788 for particles in liquids, the APSS-2000 Particle Counter has recipe functions that allow it to adapt to future regulatory changes, and its small sample volume minimizes the waste of expensive products.
The APSS-2000 Liquid Particle Counter includes an SLS-1000 Syringe Sampler, a LiQuilaz® E Series Light Obscuration Spectrometer and SamplerSight Pharma Software, allowing reports to meet 21 CFR 11 regulations for electronic records and signatures.
Additional Information:
- Item Code: APSS2000
View Complete Details
Viable Cleanroom Monitor BioCapt Impactor
Get Latest Price
Brand | Particle Measuring Systems |
Usage/Application | Laboratory |
Material | Stainless Steel |
Model Name/Number | BioCapt Impactor |
Iso Certified | Accordance with ISO 14698-1 |
Application | Facility monitoring system for clean areas |
The biocapt impactor active microbial air sampling atrium enables the capture of microbiologically viable particulates on a suitable media surface for later incubation and enumeration. The slits in the biocaptimpactor are precision cut to ensure laminar flow, thus maximizing collection efficiencies for viable particles in accordance with iso 14698-1. Biological efficiency is guaranteed by ensuring optimal impaction velocity and giving statistical control over false positive results. The biocaptimpactor can be used in dedicated facility monitoring system (fms) applications as a standalone microbial sample collection device or in portable microbial monitoring applications in conjunction with a sampling device, such as the minicapt™ portable microbial sampler.
Benefits:
- Highest validated physical and biological collection efficiencies per ISO 14698-1/Annex B
- 316L stainless steel atrium is autoclavable
- Optimal slit design ensures that microorganisms are undamaged during sampling
- Immediate and easy detection of false positives
- Microbial air sampling in cleanrooms and associated controlled environments
- USP 797 environmental viable airborn particle testing
- Bioburden monitoring of medical device manufacturing environments
- Microbial monitoring of aseptic manufacturing areas
- Microbiological monitoring of surgical suites or operating rooms
- Clean Room
- Pharmaceutical & Bulk Drugs
View Complete Details
Deionized Water Particle Counter HSLIS-M50e
Get Latest Price
Brand | Particle Measuring Systems |
Usage/Application | Laboratory |
Flow Capacity Range | 100 ml/min +- 10% |
Sensitivity | 0.05 - 0.2 nm |
Application | Provides continuous, real-time monitoring of contamination levels in DI water and process chemicals. |
Channels | 4 |
Deionized Water Particle Counter with Sensitivity range: 0.05 - 0.2 µm
The HSLIS Deionized Water Particle Counter makes it easy to always understand the characteristics of your working fluid. The combination of high sensitivity and low cost makes it ideal when large numbers of sensors and/or long-term trending are required. Integration of the HSLIS Liquid Particle Counter into Particle Measuring Systems’ Facility Net Software provides an economical way to monitor multiple flow systems and provide dedicated local display and control capabilities.
View Complete Details
Liquid Particle Counter LiQuilaz II S Series
Get Latest Price
Brand | Particle Measuring Systems |
Usage/Application | Laboratory |
Size | Dimensions (l, w, h) 12.75 x 4.25 x 4.5 in |
Channels | User adjustable from 1 to 15 |
Maximum concentration* | 10,000 particles/ml |
Sample Temperature | 32 - 302 DegreeF (0 - 150 DegreeC) |
Available in Models S02, S03, S05
LiQuilaz® II optical liquid particle counter is a volumetric monitor with a variety of sizing sensitivities as low as 0.2 µm. It provides high precision analysis for most process chemicals, including hydrofluoric acid and hot corrosive chemicals up to 306 °F (152 °C).
A unique solution in the comprehensive line of liquid particle counters, the LiQuilaz II particle counter by Particle Measuring Systems provides the same levels of accuracy, reliability and repeatability that customers have received from our instruments for many years. LiQuilaz II liquid particle counter features both RS-485 and Ethernet network communications.
Volumetric particle counting offers the highest precision possible by measuring 100% sample volumes (up to 80 ml/min) so that short sampling intervals can be utilized without sacrificing statistical significance.
View Complete Details
Liquid Particle Counter Ultra DI 20
Get Latest Price
Brand | Particle Measuring Systems |
Usage/Application | Laboratory |
Material | Stainless Steel |
Model Name/Number | Ultra DI 20 |
Sensitivity | Range: 20 - 100 nm |
Application | Laboratory water sampling WFI and Purified Water testing |
From the wordld leader for sensitivity (Range: 20 - 100 nm), ultrapure water systems, the Ultra DI® 20 Liquid Particle Counter from Particle Measuring Systems PMS quickly obtains statistically meaningful data and will count and size contaminants as small as 20 nm. Consistency helps you get more out of your data, even if the instrument moves, so you have more control over your process. The Ultra DI 20 Liquid Particle Counter has a low zero count, large sample volume and high counting efficiency that provides unsurpassed particle detection. Improved sensitivity allows you to detect process variations more quickly with 20 nm polystyrene latex (PSL) and 9 nm gold (Au).
View Complete Details
Microbial Air Sampler MiniCapt Mobile
Get Latest Price
Model Name/Number | MiniCapt Mobile |
Usage/Application | It is used in environment monitoring in clean room |
Brand | Particle Measuring Systems |
Automation Grade | Automatic |
Sensitivity | 1 cfu |
Ref. Standards | ISO 14698-1 |
Makes the job Easier-TheMiniCapt mobile microbial air sampler simplifies the job of microbial airsampling by applying modern data management capabilities that save time andreduce operator error in air sampling data. Reduced Errors with theintutive user interface that is icon driven with multiple levels Doesn’t Contaminate thecleanroom through the use of a unique HEPA filtered exhaust Flexibility of using onesampler for multiple sampling applications including monitoring compressed gas,remote isolator sampling & the ability to connect to the BioCapt False Positiveidentification can reduce investigation cost through the use of the BioCaptradial slit design
View Complete Details
01 Micron Particle Counter Lasair III 110
Get Latest Price
Brand | Particle Measuring Systems |
Usage/Application | Laboratory |
Material | Stainless Steel |
Model Name/Number | Lasair III 110 |
Application | Best instrument for portable uses like process gas monitoring with a High-Pressure Diffuser |
Range | 0.1 to 5 microns |
0.1-micron particle counter with eight user-selectable channels in the range of 0.1 to 5 microns. The best available mode in the market for ISO 1, ISO 2 types of a clean environment with optional high-efficiency exhaust filter for ISO Cleanroom Class 1-2. The best instrument for portable uses like process gas monitoring with a High-Pressure Diffuser. 1000 internal data storage with IR touch screen interface & can operate with gloves.
View Complete Details
Airborne Particle Counter Lasair Pro
Get Latest Price
Brand | Particle Measuring Systems |
Usage/Application | Laboratory |
Model Name/Number | Lasair Pro |
Features | 21 CFR Part 11 compliant audit trail with 20,000 recorded activities |
Power | Rechargable lithium ion batteries for portable use |
Ref. Standards | FDA 21 CFR Part 11 and EU GMP Annex 11 |
Advanced particle counter with full contamination control solution including clean area monitoring to meeting global standards for data integrity. Size range of 0.3 microns to 25microns with user-selectable channels in the range. Lasair Pro is 21 CFR Part 11 compliant with audit trail recorded activities. 100 users on each instrument. With unique NFC card capabilities, unlimited users can operate with unique credentials. Single can store up to 10,000 data storage capabilities with 1,000 configurable locations organized by area, room, and location hierarchy.
View Complete Details
Handheld Particle Counter Handilaz Mini II
Get Latest Price
Usage/Application | Laboratory |
Model Name/Number | Handilaz Mini II |
Brand | Particle Measuring Systems |
Flow Capacity Range | 0.1CFM flow rate |
Iso Certified | ISO 21501-4 Standard |
Application | Cleanroom or clean devices monitorinng,Spot monitoring and troubleshooting |
Handheld paricle counter with 0.1CFM flow rate with size range of 0.2 to 10 microns with unlimited size channels with 10nm resolution. Best suitable for semiconductor, sdvanced srocessing and pharmaceutical applications. Integration of temperature and differential pressure into particle
measurement. Calibrated to ISO 21501-4 Standard.
View Complete Details
Remote Air Sampler MiniCapt
Get Latest Price
Material | Stainless Steel |
Brand | Particle Measuring Systems |
Automation Grade | Automatic |
Application | Microbial air sampling in cleanrooms and associated controlled environments |
Operating environment | Temperature: 32 - 104 DegreeF (0 - 40 DegreeC); Humidity: 10 - 90% RH |
Power supply | Input: 100 - 240 VAC, 50/60 Hz, 1.5 A |
Most suitable remote air sampler for collection of microbial contaminations, with sensitivity range: 1 cfu. Designed in line with expectations as per ISO 14698. With HEPA-filtered exhaust to avoid cleanroom contamination after sampling by sampling device itself.
The impactor head inlets are precision engineered to ensure laminar flow, thus optimizing collection and biological collection efficiency in accordance with ISO 14698-1
Ideally suited for aseptic environments as part of a facility monitoring system, the MiniCapt® Remote Microbial Air Sampler from Particle Measuring Systems (PMS) simplifies the job of microbial air sampling by applying modern data management capabilities that save time and reduce operator error in air sampling data. The MiniCapt Viable Microbial Sampler uses a unique HEPA-filtered exhaust so it doesn’t contaminate the cleanroom. With a small footprint, the MiniCapt Microbial Sampler can operate virtually anywhere, without a house vacuum. Because the MiniCapt Microbial Sampler is software automated, you don’t have to gown up to control it. The pump won’t contaminate your environment, so you can set it up to monitor particles and microbials in the same location–and then forget about it. It’s also easy to clean, works with all Particle Measuring Systems’ software.
View Complete Details
Syringe Sampling System
Get Latest Price
Brand | Particle Measuring Systems |
Model Name/Number | SLS 1040 |
Shape | Square |
Usage/Application | Liquid particle sampling & Laboratory water sampling WFI and Purified Water testing |
Automation Type | Automatic |
Flow Rate | 5 ml/min |
Digital | Yes |
Particle Size Range | 40 to 125 nm |
Minimum Particle Size | 20 nm |
The SLS Syringe Liquid Particle Sampler from Particle Measuring Systems uses a precision syringe and simple flow-path for delivering chemical samples from a sample vessel or chemical container, directly to the particle sensor. It is ideal for applications where precise, small-volume particle batch sampling is required, where the sampler device cannot contribute contamination to the chemical sample.
The system consists of a selectable syringe for either corrosive or non-corrosive liquids, a selectable particle counter for different sizing sensitivities, and batch-sampling software.
View Complete Details
Airnet II Particle Sensor (4 Channel)
Get Latest Price
Brand | Particle Measuring Systems |
Usage/Application | Laboratory |
Material | Chemical-resistant polycarbonate |
Air Flow | Flow rate 0.1 or 1.0 CFM |
Model Name/Number | Airnet II |
Sensitivity | 0.2 - 10.0 nm |
Sensitivity range: 0.2 - 10.0 µm
The Airnet® II 4 Channel Particle Sensor meets the specifications of ISO 21501-4 to measure the size and number of particles suspended in the air for real-time monitoring of defect-causing particles. A simple and cost-effective way to monitor your cleanroom, the Airnet II Particle Sensor provides unparalleled performance with data transmission capabilities for remote monitoring. Versatile power options combined with an ultra-small footprint makes the Airnet II Particle Sensor easy to install right where you need it.
The unit can be configured to accept distributed power from an in-house system or power over ethernet (PoE).
Avilable in 4 channels out of conbinations of 0.2, 0.3, 0.5, 1.0, 5.0, and 10.0 μm size range. Flow rate is either 0.1 or 1.0 CFM for specific model.
Interfaces with object linking and embedding (OLE) for process control (OPC) communications, Modbus communications and optional 4-20 mA output
Chemical-resistant polycarbonate (PC) enclosure.
View Complete Details
Airnet II / IIs Remote Particle Sensors (2 Channels)
Get Latest Price
Model Name/Number | Airnet II / IIs |
Usage/Application | Facility monitoinrg system for clean areas |
Brand | Particle Measuring System |
Flow Rate | 1.0 CFM |
Material | Chemical-resistant Polycarbonate (PC) or Stainless Steel |
Sensitivity | 0.3 - 5.0 nm |
Airnet Remote Particle Sensors: 2 Channels. As part of a facility monitoring solution, the Airnet® II and IIs Particle Sensors from Particle Measuring Systems meet the specifications of ISO 21501-4 to measure the size and number of particles suspended in the air for real-time monitoring of defect-causing particles.
2 channels model for 0.5 and 5.0 μm size range, suitable for Pharmaceutical application
1.0 CFM flow rate. Communication with Modbus TCP IP. Standard POE for communication & power requirements. Although, optional 4-20 mA output (Polycarbonate version only). Available in chemical-resistant polycarbonate (PC) or Stainless Steel 316L enclosure. Optional XR coating protects sensors against corrosive or oxidizing vapours in VHP sterilization processes with Airnet II XR models.
View Complete Details
Explore more categories
- Developed and Managed by IndiaMART InterMESH Limited