1
Have a requirement?
Chat with us
1
Have a requirement?
Chat with us
VFD
Offering you a complete choice of products which include Delta VFD CT2000 Series 11 kW 380-480V, Delta VFD CT2000 Series 11kW 15HP 3-Phase 380-480V Textile Vector Control Flange Mount Drive VFD110CT43F00B and INVT Goodrive20-LA Series AC Drive, 0.4-22kW, 220V 3 Phase, V/F & Sensorless Vector Control, IP20.
Interested in this product?
Get Best Quote
Delta VFD CT2000 Series 11 kW 380-480V
Get Latest Price
| Series | CT2000 Series |
| Power Rating | 11 kW kW |
| Input Voltage | 380–480 V V |
| Input Phase | 3 Phase |
| Control Mode | FOC with PG, Sensorless Vector, TQC with PG, V/F Control, V/F Control with PG, Vector Control |
| Motor Power | 15 HP HP |
| Application | Textile |
| Communication | Modbus, RS485 |
| Brand | Delta |
| Frame Size | B |
| Cooling Method | Natural Cooling |
| EMC Filter | Optional |
| Supported Motor Type | Asynchronous Motor, Synchronous Motor |
| PLC Function | Built-in (10k steps) |
| Certifications | CE, GB/T12668-2, UL |
| DC Reactor | Optional |
| Braking Chopper | Built-in |
| Width | 200.0 mm mm |
| Height | 361.8 mm mm |
| Depth | 189.4 mm mm |
| Rated Output Current (Heavy Duty) | 17 A A |
| Rated Output Current (Normal Duty) | 24 A A |
| Output Frequency | 0.01-599.00 Hz Hz |
| Carrier Frequency | 2-15 kHz kHz |
| Overload Tolerance | Light duty: 120% of rated current for 1 minute per every 5 minutes; Heavy duty: 150% of rated current for 1 minute per every 5 minutes |
| Starting Torque | Reach up to 150% or above at 0.5Hz. Under FOC+PG mode, starting torque can reach 150% at OHz. |
| V/F Curve | 4 point adjustable V/F curve and square curve |
| Rated Output Capacity (kVA) | 18 kVA kVA |
| Input Current (Heavy Duty) | 19 A A |
| Input Current (Normal Duty) | 25 A A |
| Accel./Decel. Time | 0.00-600.00/0.0-6000.0 seconds |
| Dimension D1 | 83.2 mm |
| Dimension H1 | 336.8 mm |
| Dimension S1 | 8.5 mm |
| Dimension W1 | 173.0 mm |
| Dimension Ø1 | 22.2 mm |
| Dimension Ø2 | 34.0 mm |
| Dimension Ø3 | 43.8 mm |
| Fan Control | Version B: No Fan; Model VFD185CT43 And Above: PWM Control; Model VFD150CT43 And Below: ON/OFF Switch |
| Frequency Output Accuracy | Digital Command: ±0.01%, -10~+40°C, Analog Command: ±0.1%, 25±10°C |
| Frequency Setting Signal | +10V~-10V, 0~+10V, 4~20mA, 0~20mA, Pulse Input |
| Frequency Tolerance | 47-63 Hz Hz |
| Grounding Leakage Current Protection | Leakage Current Is Higher Than 50% Of Rated Current Of The AC Motor Drive |
| Main Control Function | Torque Control, Droop Control, Speed/Torque Control Switching, Feed Forward Control, Zero-Servo Control, Momentary Power Loss Ride Thru, Speed Search, Over-Torque Detection, Torque Limit, 17-Step Speed (Max), Accel/Decel Time Switch, S-Curve Accel/Decel, 3-Wire Sequence, Auto-Tuning (Rotational, Stationary), Dwell, Cooling Fan On/Off Switch, Slip Compensation, Torque Compensation, JOG Frequency, Frequency Upper/Lower Limit Settings, DC Injection Braking At Start/Stop, High Slip Braking, PID Control (With Sleep Function), Energy Saving Control, MODOBUS Communication (RS-485 RJ45, Max. 115.2 Kbps), Fault Restart, Parameter Copy |
| Motor Protection | Electronic Thermal Relay Protection |
| Operating Voltage Range | 323-528 Vac Vac |
| Over-Current Protection | Over-Current Protection For 200% Rated Current; Current Clamp 『Light Duty: 130-140%』;『Heavy Duty: 180-185%』 |
| Over-Temperature Protection | Built-In Temperature Sensor |
| Over-Voltage Protection | Drive Operation Stops When DC Bus Voltage Exceeds 820V |
| Output Frequency Resolution | Digital Command: 0.01Hz; Analog Command: 0.03*Max. Output Frequency / 60 Hz (±11 Bit) |
| Restart After Instantaneous Power Failure | Up To 20 Seconds (Parameter Setting) |
| Speed Response Ability | 5Hz (Vector Control Can Reach Up To 40Hz) |
| Stall Prevention | Stall Prevention During Acceleration, Deceleration And In Operation |
| Torque Accuracy At TQC Mode | ±5% |
| Torque Limit | Light Duty 130%, Heavy Duty 175% Torque Current. |
| Wind Speed At Carrier Frequency 2kHz | 3.5 m/s |
| Wind Speed At Default Carrier Frequency | 3.5 m/s |
Delta VFD CT2000 Series 11 kW 380-480V
View Complete Details
Yes, I am interested!
Delta VFD CT2000 Series 11kW 15HP 3-Phase 380-480V Textile Vector Control Flange Mount Drive VFD110CT43F00B
Get Latest Price
| Series | CT2000 Series |
| Power Rating | 11 kW |
| Input Voltage | 380–480 V |
| Input Phase | 3 Phase |
| Control Mode | V/F Control, Sensorless Vector, V/F Control with PG, FOC with PG, TQC with PG |
| Motor Power | 15 HP |
| Enclosure | Panel Mount |
| Application | Textile |
| Braking Type | Dynamic Braking |
| Communication | Modbus, RS485, Modbus RTU |
| Brand | Delta |
| Frame Size | B |
| Cooling Method | Natural Cooling |
| EMC Filter | Optional |
| Supported Motor Type | Asynchronous Motor |
| PLC Function | Built-in (10k steps) |
| Certifications | CE |
| DC Reactor | Optional |
| Braking Chopper | Built-in |
| Width | 200.0 mm |
| Height | 361.8 mm |
| Depth | 189.4 mm |
| Weight | 2.6 kg |
| Safety Standards | Safe Torque Off (STO) |
| Rated Output Current (Heavy Duty) | 17 A |
| Rated Output Current (Normal Duty) | 24 A |
| Output Frequency | 0.01-599.00 Hz |
| Carrier Frequency | 2-15 kHz |
| Overload Tolerance | Light duty: 120% of rated current for 1 minute per every 5 minutes; Heavy duty: 150% of rated current for 1 minute per every 5 minutes |
| Efficiency | 97.8% |
| Power Factor | >0.98 |
| Operating Temperature | -10~40 °C |
| Starting Torque | Reach up to 150% or above at 0.5Hz. Under FOC+PG mode, starting torque can reach 150% at 0Hz. |
| V/F Curve | 4 point adjustable V/F curve and square curve |
| Rated Output Current (Light Duty) | 3 A |
| Rated Output Current | 60 A |
| Rated Output Current (Super Heavy Duty) | 1.7 A |
| Rated Input Current | 24 A |
| Rated Output Capacity (kVA) | 19 kVA |
| Safe Torque Off (STO) | Yes |
| Rated Output Current (Constant Torque) | 17 A |
| Rated Output Current (Variable Torque) | 21 A |
| Input Current (Heavy Duty) | 19 A |
| Input Current (Normal Duty) | 25 A |
| Operating Voltage Range | 323-528 Vac |
| Frequency Tolerance | 47-63 Hz |
| Wind Speed At Carrier Frequency 2kHz | 3.5 m/s |
| Wind Speed At Default Carrier Frequency | 3.5 m/s |
| Speed Response Ability | 5 Hz (vector control can reach up to 40 Hz) |
| Torque Limit | Light duty 130%, Heavy duty 175% torque current. |
| Torque Accuracy At TQC Mode | ±5% |
| Frequency Output Accuracy | Digital command: ±0.01%, Analog command: ±0.1% |
| Output Frequency Resolution | Digital command: 0.01 Hz; Analog command: 0.03*max. output frequency / 60 Hz (±11 bit) |
| Frequency Setting Signal | +10V~-10V, 0~+10V, 4~20mA, 0~20mA, Pulse input |
| Accel./Decel. Time | 0.00-600.00/0.0-6000.0 seconds |
| Main Control Function | Torque control, Droop control, Speed/torque control switching, Feed forward control, Zero-servo control, Momentary power loss ride thru, Speed search, Over-torque detection, Torque limit, 17-step speed (max), Accel/decel time switch, S-curve accel/decel, 3-wire sequence, Auto-Tuning (rotational, stationary), Dwell, Cooling fan on/off switch, Slip compensation, Torque compensation, JOG frequency, Frequency upper/lower limit settings, DC injection braking at start/stop, High slip braking, PID control (with sleep function), Energy saving control, Fault restart, Parameter copy |
| Fan Control | Version B: no fan; Model VFD185CT43 and above: PWM control; Model VFD150CT43 and below: ON/OFF switch |
| Motor Protection | Electronic thermal relay protection |
| Over-Current Protection | Over-current protection for 200% rated current; current clamp Light duty: 130-140%; Heavy duty: 180-185% |
| Over-Voltage Protection | Drive operation stops when DC bus voltage exceeds 820V |
| Over-Temperature Protection | Built-in temperature sensor |
| Stall Prevention | Stall prevention during acceleration, deceleration and in operation |
| Restart After Instantaneous Power Failure | Up to 20 seconds (parameter setting) |
| Grounding Leakage Current Protection | Leakage current is higher than 50% of rated current of the AC motor drive |
| Dimension W1 | 173.0 mm |
| Dimension H1 | 336.8 mm |
| Dimension D1 | 83.2 mm |
| Dimension S1 | 8.5 mm |
| Dimension Ø1 | 22.2 mm |
| Dimension Ø2 | 34.0 mm |
| Dimension Ø3 | 43.8 mm |
Delta VFD CT2000 Series 11kW 15HP 3-Phase 380-480V Textile Vector Control Flange Mount Drive VFD110CT43F00B
View Complete Details
Yes, I am interested!
INVT Goodrive20-LA Series AC Drive, 0.4-22kW, 220V 3 Phase, V/F & Sensorless Vector Control, IP20
Get Latest Price
| Series | Goodrive20-LA |
| Power Rating | 0.4 kW, 0.75 kW, 1.5 kW, 2.2 kW, 3.7 kW, 5.5 kW, 7.5 kW, 11 kW, 15 kW, 22 kW |
| Input Voltage | 200–240 V |
| Input Phase | 3 Phase |
| Control Mode | V/F Control, Sensorless Vector |
| Enclosure | IP20 |
| Application | Textile Machinery, Food Machinery, Printing, Packaging, Ceramic Equipment, Woodworking, Pump, Fan, Conveyor |
| Braking Type | Built-in |
| Communication | Modbus RTU |
| Brand | INVT |
| Supported Motor Type | Asynchronous Motor |
| Mounting Type | Wall Mount, Rail Mount |
| Cooling Type | Forced Air Cooling |
| Ambient Temperature | -10 to 50°C |
| Overload Capability (G-Type/Heavy Load) | 150% for 60s, 180% for 10s, 200% for 1s |
| EMC Filter | Built-in C3 |
| Safety Function (STO) | Optional |
| Output Frequency | 0-400 Hz |
| Input Frequency | 47-63 Hz |
| Multifunction Terminal | 4 Inputs (S1~S4) |
| High Speed Pulse Input | 1 Input (HDI) |
| Analog Input (Voltage) | 2 Inputs (0~10V, -10~+10V or 0~20mA) |
| Relay Output | 2 Outputs |
| Open Collector Output | 1 Y terminal ON-OFF Output |
| Analog Output | 2 Outputs (0~10V or 0~20mA) |
| Keypad | LED 7-segment |
| Remote Cable | 2m, 3m, 5m, 10m (30m max) |
| Free Software | INVT Workshop |
| Ambient Humidity | Relative humidity 95% RH or below (without any dew formation) |
| Storage Temperature | -20 °C~65 C |
| Surrounding Environment | Non-corrosive gas, flammable gas, oil residue and dust in a indoor environment |
| Altitude | ≤ 1,000m above sea level (From 1,000m or more, voltage/output current derating by 1% for every 100m elevation; up to 4,000m) |
| Output Voltage (V) | 0~input voltage error <5% |
| Speed Ratio | 1:100 |
| Speed Control Accuracy | ±0.2% |
| Speed Fluctuation | ±0.3% |
| Torque Response | <20ms |
| Torque Control Accuracy | 10% |
| Starting Torque | 0.50Hz/150% |
| Frequency Setting | Digital setting, analog setting, pulse frequency setting, multi-step speed running setting, simple PLC setting, PID setting, MODBUS communication setting |
| Auto-adjustment of the Voltage | Keep constant voltage automatically with grid voltage transients |
| Fault Protection | Provides more than 30 fault protection functions: overcurrent, overvoltage, undervoltage, overheating, phase loss and overload, etc. |
| Restart after Rotating Speed Tracking | Smooth starting of the rotating motor |
| Analog Input | 1 (AI2) 0~10V/0~20mA and 1 (AI3) -10~10V |
| Digital Input | 4 common inputs, the maximum frequency: 1kHz; 1 high speed input, the maximum frequency: 50kHz |
| DC Reactor | ≥11kW standard built-in DC reactors |
| Braking Resistor | Optional |
INVT Goodrive20-LA Series AC Drive, 0.4-22kW, 220V 3 Phase, V/F & Sensorless Vector Control, IP20
View Complete Details
Yes, I am interested!
Tell us what you need, and we’ll help you get quotes
Tell us what you
need
need
Receive seller
details
details
Seal the deal
Pay with IndiaMART