We are a leading Distributor / Channel Partner of FMTU Diesel Generator Set (Rolls-Royce Solution), FMTU Diesel Generator Set(Rolls-Royce Solution), FMTU Diesel Generator Set (Rolls-Royce Solution), 650 KVA FMTU Diesel Generator (Rolls-Royce Solution) and 625 Kva Generators Fmtu A Rolls-Royce Solution from Bengaluru, India.

  • FMTU Diesel Generator Set (Rolls-Royce Solution)
  • FMTU Diesel Generator Set (Rolls-Royce Solution)
  • FMTU Diesel Generator Set (Rolls-Royce Solution)
  • FMTU Diesel Generator Set (Rolls-Royce Solution)
Interested in this product?
Get Best Quote
Power (kVA)500 kVA
Genset BrandMTU
Model NumberFM500
Phase3-Phase
Fuel Consumption (at 100% Load)105.0 Ltrs/ Hr
Fuel Tank Capacity990 Litre
Frequency50 Hz
Voltage415 V
Engine Type4-cycle
Engine Displacement17.5 Litre
Engine Bore122 mm
Engine Stroke150 mm
Compression Ratio17.5
Rated Speed1500 rpm
Engine GovernorECU 8 (G3 Class)
Nominal Power448 kWm
Air CleanerDry
Max. Fuel Flow5.7 Ltrs/min
Total Oil System60.5 Litre
Oil Change Quantity53 Litre
Total Coolant Capacity135 Litre
Engine Oil Pressure4.5 Bar
ControllerDSE 7320 MKII AMF Ready
Circuit Breaker4P, MCCB
Exhaust Flow1.56 m3 /s
Exhaust Temp after Turbo500 Degree Celsius
Exhaust Back Pressure85 mBar
Generator Type4Pole, Brushless
Insulation ClassH-class
EnclosureIP23 M
Voltage Regulation+- 0.25%
AVR TypeDigital
Winding Pitch2/3
Efficiency94.6%
Number Of Batteries2
Capacity2 x 105 Ah
Ambient Capacity Of Radiator45 Degree Celsius
Heat Rejection To Coolant216 kW
Combustion Air Flow0.57 m3 /s
Cooling Air Flow7.5 m3 /s
Dimension5800 x 2000 x 2200 mm
Weight7208 Kg

Features:
  • Fully authority CRDI engine with superior
  • fuel economy and Industry leading
  • average load factor
  • Silencer Placement inside enclosure
  • Digital Voltage & Frequency regulation
  • Remote monitoring & diagnosis
  • Major Service points on one side of the system
  • Longer maintenance interval 500 Hours or 2 Years
  • No schedule overhaul
  • Radiator, Engine & Alternator mounted
  • on single skid
  • Radiator with 45°C ambient temperature
  • Dry type air filter with restriction indicator
  • Integrated Fuel tank with 09 hours capacity
  • Fuel Cooler & Fuel pre filter with water Separator
  • AC Panel and DC Control Panel mounted inside enclosure

Definition as per ISO 8528-1 (PRP)
  • Prime power is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer.

Definition as per ISO 8528-1 (ESP)
  • Emergency standby power is defined as the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers.

View Complete Details

Yes, I am interested!

  • FMTU Diesel Generator Set(Rolls-Royce Solution)
  • FMTU Diesel Generator Set(Rolls-Royce Solution)
Interested in this product?
Get Best Quote
Power (kVA)450 kVA
Genset BrandMTU
Model NumberFM450
Phase3-Phase
Fuel Consumption (at 100% Load)91.50 Ltrs/ Hr
Frequency50 Hz
Voltage415 V
Type4-cycle
Engine Displacement17.5 Litres
Engine Bore122 mm
Engine Stroke150 mm
Engine Compression Ratio17.5
Rated Speed1500 rpm
Engine GovernorECU 8 (G3 Class)
Air CleanerDry
Generator Type4Pole, Brushless
Insulation ClassH-class
EnclosureIP23 M
Voltage Regulation+- 0.25%
AVR TypeDigital
Winding Pitch2/3
Efficiency94.6%
Total Oil System60.5 Litre
Oil Change Quantity53 Litre
Coolant Capacity135 Litre
Engine Oil Pressure4.5 Bar
ControllerDSE 7320 MKII AMF Ready
Circuit Breaker4P, MCCB
Exhaust Flow1.14 m3 /s
Exhaust Temp after Turbo549 Degree Celsius
Exhaust Back Pressure85 mBar
Number Of Batteries2
Capacity2 x 105 Ah
Ambient Capacity Of Radiator45 Degree Celsius
Heat Rejection To Coolant216 kW
Combustion Air Flow0.40 m3 /min
Cooling Air Flow7.5 m3 /min
Dimension5800 x 2000 x 2200 mm
Weight7208 Kg

Features:
  • Fully authority CRDI engine with superior
  • fuel economy and Industry leading average load factor
  • Silencer Placement inside enclosure
  • Digital Voltage & Frequency regulation
  • Remote monitoring & diagnosis
  • Major Service points on one side of the system
  • Longer maintenance interval 500 Hours or 2 Years
  • No schedule overhaul
  • Radiator, Engine & Alternator mounted on single skid
  • Radiator with 45°C ambient temperature
  • Dry type air filter with restriction indicator
  • Integrated Fuel tank with 09 hours capacity
  • Fuel Cooler & Fuel pre filter with water Separator
  • AC Panel and DC Control Panel mounted inside enclosure

Definition as per ISO 8528-1 (PRP)
  • Prime power is defined as being the maximum power which a generating set is capable of delivering continuously while supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer.

Definition as per ISO 8528-1 (ESP)
  • Emergency standby power is defined as the maximum power available during a variable electrical power sequence, under the state operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers.
Force MTU Benefit:
  • Global product design, single factory manufacturing product for the world
  • Best in class smallest foot print
  • Services of the future:
  • Service call request available on your
  • finger tip
  • Genset health monitoring through
  • mobile App and remote desktop
  • Remote diagnostic
  • 2 Years or 5000 Hours warranty on entire
  • Diesel Generator System

View Complete Details

Yes, I am interested!

Interested in this product?
Get Best Quote
Power (kVA)600 kVA
Genset BrandMTU
Model NumberFM600
Phase3-Phase
Fuel Tank Capacity900 Litre
Frequency50 Hz
Voltage415 V
Engine Type4-Cycle
Engine Displacement21 Litre
Engine Bore122 mm
Engine Stroke150 mm
Compression Ratio17.5
Rated Speed1500 rpm
Engine GovernorECU 8
Nominal Power524 kWm
Air CleanerDry
Max. Fuel Flow5.7 Litre/min
Total Oil System72.5 Litre
Oil Change Quantity54 Litre
Coolant Capacity140 Litre
Engine Oil Pressure4.5 Bar
ControllerDSE 7320 MKII
Circuit Breaker4P,Manual ACB
Exhaust Flow1.5 m3/s
Exhaust Temp after Turbo482 Degree Celsius
Exhaust Back Pressure85 mBar
Generator Type4 Pole Brushless
DutyPrime
Insulation ClassH-Class
BearingSingle
EnclosureIP23
Voltage Regulation+-0.5%
AVR TypeDigital
Winding Pitch2/3
Efficiency94.7%
Number of Batteries2
Capacity2 X 105 Ah
Ambient Capacity Of Radiator45 Degree Celsius
Heat Rejection To Coolant231 kW
Combustion Air Flow0.60 m3/s
Cooling Air Flow8 m3/s

Features:
  • Fully authority CRDI engine with superior
  • fuel economy and Industry leading average load factor
  • Silencer Placement inside enclosure
  • Digital Voltage & Frequency regulation
  • Remote monitoring & diagnosis
  • Major Service points on one side of the system
  • Longer maintenance interval 500 Hours or 2 Years
  • No schedule overhaul
  • Radiator, Engine & Alternator mounted on single skid
  • Radiator with 45°C ambient temperature
  • Dry type air filter with restriction indicator
  • Integrated Fuel tank with 09 hours capacity
  • Fuel Cooler & Fuel pre filter with water Separator
  • AC Panel and DC Control Panel mounted inside enclosure

Definition as per ISO 8528-1 (PRP)
  • Prime power is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer.

Definition as per ISO 8528-1 (ESP)
  • Emergency standby power is defined as the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers.

View Complete Details

Yes, I am interested!

Interested in this product?
Get Best Quote
Genset BrandMTU
Model NumberFM650
Type4-Cycle
Arrangement12V
Displacement21 L
Bore122 mm
Stroke150 mm
Compression Ratio17.5
Rated1500 rpm
Engine GovernorECU 8
Nominal Power576 kWm
Air CleanerDry
Max. Fuel Flow5.7 L/min
Fuel Tank Capacity:990 L
At 100% of Power Rating130.10 L/hr
At 75% of Power Rating100.00 L/hr
Total Oil System72.5 L
Engine Oil Change Quantity53 L
Total Coolant Capacity140 L
Engine Oil Pressure4.5 Bar
ControllerDSE 7320 MKII
Circuit Breaker4P,Manual ACB, 50kA
Exhaust Flow2.1 m3/s
Exhaust Temp After Turbo483 DegreeC
Exhaust Back Pressure85 mBar
DutyPrime
Generator Type4 Pole Brushless
Insulation ClassH-Class
BearingSingle
EnclosureIP23
Voltage Regulation+-0.5%
Exciting SystemMAUX Auxiliary
AVR TypeDigital
Winding Pitch2/3
Rated Speed1500
Rated Voltage415 v
Alternator Efficiency94.8%
Electric System volts DC24 v
Number of Batteries2
Capacity2 X 105 Ah
Ambient Capacity of Radiator:45 DegreeC
Pressure on rad0.2 kpa
Heat Rejection to Coolant255 kw
Aspirating0.8 m3/s
Cooling Air Flow:8 m3/s
Length6200 mm
Width2000 mm
Height2400 mm
Weight8580 kg

Special Features:
  • Fully authority CRDI engine with superior fuel economy and Industry leading average load factorSilencer Placement inside enclosure
  • Digital Voltage & Frequency regulation
  • Remote monitoring & diagnosis
  • Major Service points on one side of the system
  • Longer maintenance interval 500 Hoursor 2 Years
  • No schedule overhaul

Force MTU Benefit:
  • Global product design, single factory
  • manufacturing product for the world
  • Best in class smallest foot print
  • Services of the future
  • Service call request available on your finger tip
  • Genset health monitoring through mobile App and remote desktop
  • Remote diagnostic
  • 2 Years or 5000 Hours warranty on entire
  • Diesel Generator System

Standard Features:
  • Radiator, Engine & Alternator mounted on single skid
  • Radiator with 45°C ambient temperature
  • Dry type air filter with restriction indicator
  • Integrated Fuel tank with 09 hours capacity
  • Fuel Cooler & Fuel pre filter with water Separator
  • AC Panel and DC Control Panel mounted inside enclosure

View Complete Details

Yes, I am interested!

Interested in this product?
Get Best Quote

625 Kva Generators Fmtu A Rolls-Royce Solution

₹ 37,95,000/ SetGet Latest Price

Minimum Order Quantity: 1 Set

Power (kVA)500 kVA
Model NumberFM625
Engine MakeRolls-Royce
Phase3-Phase
Fuel Consumption (at 100% Load)122.50
Fuel Tank Capacity72.5
AMCAvailable
On-site ServiceAvailable
Dry Weight (Kg)8580 kg

Industrial Diesel Genrator from Rolls-Royce Brand.
Fully authority CRDI engine with superior fuel economy and Industry leading average load factor
  Silencer Placement inside enclosure
 Digital Voltage & Frequency regulation
 Remote monitoring & diagnosis
  Major Service points on one side of the system
 Longer maintenance interval 500 Hours or 2 Years
 No schedule overhaul

View Complete Details

Yes, I am interested!

Get in touch with us

Reach Us

Apollo Power Systems Private Limited31, 1st Floor, 1st Main Road, Chamarajpet, Bengaluru-560018, Karnataka, India

Sachit Srinivas (Director)

View Mobile Number14% Call Response Rate

Send SMS
Send Email
Send Payment
Leave a Message, we will call you back!
Send your enquiry to this supplier
terms privacy policy

We Accept Online Payments

All Rights Reserved (Terms of Use)