X
View Mobile Number83% Response Rate
Hi
terms privacy policy
Verifying...
1

Have a requirement?
Get Best Price

Hi
terms privacy policy
Verifying...
1

Have a requirement?
Get Best Price

BCH Auto Transformer Starter

Pioneers in the industry, we offer BCH Upto 800 HP Auto Transformer Starter from India.

  • BCH Upto 800 HP Auto Transformer Starter
  • BCH Upto 800 HP Auto Transformer Starter
  • BCH Upto 800 HP Auto Transformer Starter
  • BCH Upto 800 HP Auto Transformer Starter
  • BCH Upto 800 HP Auto Transformer Starter
  • BCH Upto 800 HP Auto Transformer Starter
  • BCH Upto 800 HP Auto Transformer Starter
BCH Upto 800 HP Auto Transformer Starter
Interested in this product?
Get Best Quote
BrandBCH
ConditionNew
Available PowerUpto 800HP
Standard Tappings50% , 65% and 80%
Auto Transformers TypeAir Cooled /Oil cooled

When a squirrel cage motor is started on full voltage Direct On Line, the electrical system experiences a current surge. The peak starting current can be as high as 6-8 times the rated current & this can cause a voltage dip in supply system. Also, the motor & driven equipment experiences a torque surge, which can cause serious mechanical problems,. In most cases, it is desirable to reduce these surges to safe levels, particularly for higher rating motors (>10HP)
The normal approach is to start the motor on reduced voltage & open-transition Star-Delta starting is most common. For this, the motor must have all leads (6 or 12) brought out to facilitate star/delta connection. Supply is applied to motor with stator winding star-connected. This gives the effect of reduced voltage (58%) on  the windings & the peak starting current is limited to 1.7-2.5 time rated. The peak starting torque is also limited to 0.25-0.4 times rated torque. When the motor speed is close to torque-equilibrium, the Star contactor is opened & Delta contactor is energised to connect the stator windings in Delta.
S-D starting can be used in applications where low starting torque is permissible. However, main problem comes during transition from star to delta. A high transient current is generated during transition, & care must be taken to prevent nuisance tripping of SCPD. In certain applications, equipment may be subjected to mechanical jerk also, leading to high wear & tear.An effective reduced voltage starting method is Auto Transformer Starter, which provides solution to transient problems & has other advantages over star-delta starting.

Features:
Range
  • 10 tank Processed bolted construction enclosure
  • Superior gasket,

Protection
  • Short Circuit (with MCCB or SDFU)
  • Overload and Single Phasing (with Overload relay)
  • Under voltage/Over Voltage /Single Phasing/Phase Reversal
  • Other protections available on request

Metering and Indication
  • Voltmeter with selector switch
  • Ammeter with selector switch
  • R,Y, B phase indication
  • Motor ON, OFF and Trip indication

Advantages of Auto-transformer Starter
  • Flexibility: Different voltage taps of auto-transformer allows adjustments for a range of starting current and  torque requirements. In applications like mixing, extruding or conveyor, such flexibility to alter starting parameters can be a definite advantage, because the besttapping can be selected during commissioning as per required starting torque. The standard taps are 50%, 65% and 80% of the full line voltage. Accordingly, the starting torque is 25%, 42% and 64%. Voltage applied to the motor may be increased in multiple steps also to achieve very smooth acceleration.
  • Smoothness: BCH ATS are closed transition type, an arrangement that maintains a continuous power supply to the motor during the transition from reduced to full voltage. This avoids the high transient switching current characteristic of open-transition type starters, & there in no danger of nuisance tripping of SCPD in case of ATS. Also, the transition is smooth & no mechanical jerk is forced on the equipment. This feature is particularlyuseful in applications like pumps, fans & compressors, where it helps to reduce wear & tear of equipment.
  • Performance: An ATS provides highest starting torque per ampere of line current drawn. So, it is best used where high torque is required to overcome the inertia of the load, & at the same time starting current must be limited to minimum.

View Complete Details

Yes, I am interested!
Tell us what you need, and we’ll help you get quotes
Tell us what you
need
Receive seller
details
Seal the deal
Pay with IndiaMART
Tell us what you need, and we’ll help you get quotes
terms privacy policy