Providing you the best range of Chromatography Data System - Single and Dual Channel, HPLC Column Heater, HPLC Filter Holder, Filter Membranes, Mooney Viscometer and On-line Solvent Degassing with effective & timely delivery.

Chromatography Data System - Single and Dual Channel
Interested in this product?
Get Best Quote

Description

  • This software can be connected to all chromatography system, such as GC, HPLC, CPC, IC, CE, and it can replace all traditional recorder and integrator as well.
  • It is compatible with Agilent, Hitachi, Jasco, Perkin-Elemr, Shimadzu, Thermo, Varian and Waters chromatography system.
  • The software has a dual-channel interface, which can receive signal whether directly from signal detector or simultaneously form both detectors.
  • It is a flexible and reliable data handling system designed according to GLP norm. It is better suitable for research or other manufacturing industry.

Features

  • Peak-ABC Chromatography Data Handling System is easy to operate because all you have to do is to learn the functions of these Six working tables. While the first two are for acquiring and processing a chromatogram, the remaining four are for identifying components; selecting an appropriate method of an analysis respectively.
  • All the elements of an analysis (e.g. the acquired data signal; the integrated chromatogram; the applied integration methods; to the calculated results) are centralized in one source document called Chromatogram file in compliance with GLP requirements.
  • These elements are intelligently structured within one screen comprising our unique Six working tables and a Chromatogram frame for your easy access and operation.
  • When acquiring a data signal, we apply our patented Noise Filtering Method so as to detect the weakest signal close to the Baseline noise.
  • When integrating a chromatogram, setting of parameters has been intelligently automated by the Default Integration. When applying Manual integration for post-acquisition processing, all you need to do is just make three clicks on the mouse within the very same screen.
  • When applying Quantitative analysis, you can conveniently choose from the whole range of Quantifying methods by making just one click.
  • For reporting, you can customize the report in Word or WordPad application to be inclusive of the chromatogram the various calculated statistics and the manually input external reference information.
  • Fully automated via One-stop processing with any Auto sampler.
  • Other features are Export to Excel, Chromatogram complier, Result table complier, Save/ Load Template, etc.
  • Hardware Specifications
  • Connect to computer by USB Port Digital Cable, connect to instrument by Signal cable
  • 24-bit high precision Analog/Digital conversion device
  • Input bipolar range: ±1.3V; ±4V
  • Input resistance: > 10M
  • Linearity: ±0.005% of full scale
  • Acquisition speed: Programmable at 1, 2, 5, 10, 20 Hz.
  • Max of 60Hz is available upon request before delivery
  • Integration sensitivity: 0.05μV•s
  • Consistency: ±0.005%
  • Minimum resolution: 1μV
  • Accuracy more than 22 bit at 60H
  • Equipped with a remote starter to be connected to analytical instrument or Auto sampler to receive the Start/Run signal

Computer Requirements

  • Intel Pentium 100MHz or better installed with Windows 95, 98, ME, NT, 2000, or XP
  • CD-ROM driver for installation of software
  • VGA graphics adapter (800 × 600 or higher resolution is recommended)
  • 16M of RAM (32M or higher is better)
  • 30MB free space on hard disk for software installation
  • Free COM/USB port for security keyLaboratory.

 

View Complete Details

Yes, I am interested!

HPLC Column Heater
Interested in this product?
Get Best Quote

HPLC Column Heater

Get Latest Price

This instrument is used to stably and precisely control the temperature of analysis thus sensitivity, separation of peaks, analysis time of the chromatography management can be improved to ensure the accuracy and reproducibility of sample results.

Features

  • Unified design allows the column flexible arrangement of horizontal or vertical setting.
  • Accurate temperature control and display: Two 4-digit LED display can ensure temperature control accuracy to ±0.1ºC.
  • Fast and easy column installation: Magnetic elements create easy opening and closing of the column heater cover.
  • Easy for observation: Transparent window allows clear view inside the HPLC column.
  • Safe anti-leaking design: A container placed under heating chamber can prevent liquid from leaking.
  • Flexible column placement: Provide stainless clamp holder inside heating chamber to make it easy for installing the column under heat.
  • Smooth pipe: Provide smooth connection between input and output ports to guarantee that liquid can pass through.
  • Stable column heater base: Provide additional large size base that can be mounted with column heater when required to stabilize the column heater.
  • Convenient sample inserting valve component kits that can be fixed at any height of the column heater.
ModelHPLC CH-300 (500) Column Heater
Temperature RangeRoom temperature to 100ºC
Max Temperature110ºC
Temperature Increment±0.1ºC
Temperature Control Accuracy±0.1ºC
Temperature Stability±0.1ºC
Display4-digit LED Actual Temperature Display (Red)
4-digit LED Set Temperature Display (Green)
Power Consumption125W (CH-300)
160W (CH-500)
External Dimensions (W × D × H)CH-300: 64mm × 105mm × 490mm
CH-500: 110mm × 105mm × 540mm
Column Dimensions (W × D × H)CH-300: 45mm × 33mm × 360mm
CH-500: 82mm × 33mm × 400mm

 



Additional Information:

  • Item Code: HPLCCh-300

View Complete Details

Yes, I am interested!

HPLC Filter Holder
Interested in this product?
Get Best Quote

HPLC Filter Holder

Get Latest Price

Widely used in gravimeter, microanalysis, colloid dispersion and bacteria-free experiments, this HPLC filter holder can filtrate and degas the mobile phase of HPLC analysis. Besides playing a critical role in lifetime extension of apparatus and HPLC column, the filter holder can enhance measurement accuracy.

The filtration bottles have high pressure endurance, fabulous interchange ability, and well-proportional wall. They are made according to international standard sizes so that they can match most products of foreign brands. In addition, the newly designed solvent pickup adaptor can filtrate or collect solvent directly from solvent bottle through film of filter. This new design makes the process of filtrating become easier and it can dramatically increase effectiveness and reduce air pollution.

Features

  • High-quality and hard-glass materials that can endure more than 200 temperature difference.
  • Elegantly made with well-proportional wall.
  • Good endurance of high pressure and fabulous interchange ability.
  • Made according to international standard sizes that can match most foreign brand products.
Packing List
FS-10, 20FS-01

Glass Funnel: 47mm, 300ml

Glass Funnel: 47mm, 300ml

Plug

Silicone Plug

Fritted Glass Support Base: 47mm

Aluminum Clamp: 47mm

Aluminum Clamp: 47mm

Fritted Glass Support Base: 47mm

Erlenmeyer Flask: 1000ml (FS-10), 2000ml (FS-20)

Glass Cover

 

Beaker

 

Teflon Base

 



Additional Information:

  • Item Code: FS10

View Complete Details

Yes, I am interested!

Filter Membranes
Interested in this product?
Get Best Quote

Filter Membranes

Get Latest Price

Description and Features

The membranes are made of hydrophilic and highly solvent resistant material. They are of high quality and can be applied in general and sterilization of aqueous and organic samples. These membranes have a variety of membrane types include :

  • Membranes of MCE
  • MCE membranes are all hydrophilic and low protein binding; usually used for general biological filtration, sterilization, and filtration of aqueous solutions.
  • Membranes of Nylon
  • Nylon membranes are hydrophilic and resistant to many solvents; generally used for filtration and clarification of aqueous or organic solutions.
  • Membranes of PVDF
  • PVDF (Polyvinylidene difluoride) membranes has advantages of low protein binding, solvent resistant; made of hydrophilic material used for HPLC sample filtration and general biological filtration.
  • Membranes of PTFE
  • PTFE membranes can be used to filter solvents and strong acids.  Although PTFE is inherently hydrophobic, it can be made hydrophilic by pre-wetting the membrane with methanol and then using with aqueous solutions.
Specifications
13mm Membrane
Cat No.Membrane TypePore Size (um)Diameter (mm)Qty/pkg
MJM2213MCE0.2213MM100
MJM4513MCE0.4513MM100
MNY2213Nylon0.2213MM100
MNY4513Nylon0.4513MM100
MPV2213PVDF0.2213MM100
MPV4513PVDF0.4513MM100
MPT2213PTFE0.2213MM100
MPT4513PTFE0.4513MM100

 

View Complete Details

Yes, I am interested!

Mooney Viscometer
Interested in this product?
Get Best Quote

Mooney Viscometer

Get Latest Price

Features

Mooney Viscometer is a shearing disk Viscometer, designed for accurate measurement of viscosity, scorch time and cure rates of the elastomers.

The instrument consists of flat, cylindrical disk, driven by a motor to rotate slowly and continuously in one direction. This disk is embedded into elastomer specimen which is confined in a heated die cavity maintained at specified temperature and kept closed by a specified force. As the disk rotates its experiences a shear strain. This resistance to rotation offered by the elastomer is shearing viscosity which is proportional to mean absolute viscosity of the specimen.

Normally a preheat period is given to the elastomer following which the disk starts to rotate. An initial high viscosity is recorded and then as the viscosity also decreases, to a minimum value Viscosity obtained with large rotor are approximately twice those of small rotor.

The viscosity is reported as under:

  • Method of sample preparation
  • Mooney viscosity number
  • Rotor size
  • Preheat time
  • Time interval to viscosity reading
  • Temperature of test

Typical test results are stated as under: 50ML(l+4)100C

Where,

  • 50M = Viscosity in mooney units
  • L = Large rotor (for small replace it with 'S')
  • l =Preheat time in minutes
  • 4 = Time in minutes after starting the motor at which the reading is taken
  • 100C = Test temperature

Features of Software and Hardware

  • Cromtech India will provide a unit on the Mooney Viscometer which will interface between computer and Mooney Viscometer
  • Delete Option (Stock, Batch No.)
  • Provision Quality Gates (pass/ fail criteria)
  • Statistical Analysis (Sigma, Range, Mean, Standard Deviation)
  • Output data Reports - VI, VM, ML(1+4), ML(1+8), T5, T35, T30, Stop Time, End Temp and Status, Cp, Cpk, Values (Bar Graph)
  • User Friendly Software Windows based
  • Temperature Graph will appear along with Mooney Graph
  • Huge Capacity of Data Storage and Retrieval
  • Color Printout
  • Flexible Testing timings
  • On line display of Mooney vs Time graph 
Technical Specifications
Mooney Measuring Range:0 to 200 MU.
Pre-Heat Time:0 to 10 minutes
Mooney measurements:Choice of 3 readings
Standards:According to ASTM D1646, ISO269
Rotor Size:Large and Small
Rotor Speed:2.0+0.02 r.p.m.
Drive Motor:Synchronuous geared motor.
Temperature:PT-100 Microprocessor Controlled.
Calibrated Range:50°C to 200°C Independent Upper and Lower Platen Control.
  
Temperature Control:Accuracy ±0.5°C
Torque Transducer:Reaction Torque Sensor. Four Arm temperature compensated semi-conducter strain guage bridge


 

 

 

 

 

 

 

View Complete Details

Yes, I am interested!

On-line Solvent Degassing
Interested in this product?
Get Best Quote

Description
This on-line solvent degassing equipment is installed between the mobile phase reservoir and HPLC pump. The mobile phase solvent enters the degasser entry through permeable membrane tube placed in a vacuum chamber. Because of the pressure difference of the wall of the permeable membrane tube, the dissolved gas continuously leaks out of the tube thus causing degassing for the mobile phase solvents. The degassed mobile phase is then moved to HPLC pump entrance through the gas-proof tube.

Specifications 
ModelOn-line Solvent Degassing
Number of channels2, 3, 4
Internal Volume/channel15ml
Maximum Flow Rate/channel10ml/min
Maximum Pressure/channel5psig
Dimensions (L × W × H)278mm × 86mm × 155mm
Power Requirement50/60Hz, 220V/110V
Weight (Kg)6 Kg

View Complete Details

Yes, I am interested!

Spectro Photo Meter - Atomic Absorption
Interested in this product?
Get Best Quote

Features

  • Innovated rich oxygen air-acetylene flame analysis technique
  • Integrated flame/graphite furnace atomization system, changeable with flame emission burner
  • Accurate fully automated control system
  • Reliable fully automatic graphite furnace analysis
  • Perfect safety protection measures
  • Advanced and reliable electronic design
  • Easy and practical analysis software

Comparison

Characteristic Mass of Some Elements using rich oxygen air-C2H2 flame and other flame methods

ElementWavelength (nm)Rich oxygen air–C 2 H2 flameN2O – C2H2 flameAir – C2 H2 flame
Ca422.70.0090.050.07
Yb378.80.0370.087.6
Eu459.40.1370.33.0
Al309.30.40.7 
Sr460.70.0160.10.15
Ba553.50.10.410.0
Mo313.30.150.40.8
W255.13.25.0 
Ga287.40.41.01.3
Sm429.72.928.5 
La550.137.235.0 
Sn224.60.83.050

 



Additional Information:

  • Item Code: WFX210

View Complete Details

Yes, I am interested!

Gas Chromatography
Interested in this product?
Get Best Quote

Gas Chromatography

Get Latest Price

Applications:

SP-3400 Gas Chromatograph, made according to international standards, its technical feature and index are in the world high level. The key components are imported from world famous suppliers. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology, scientific research, etc.

Column Oven
Operating temperatureambient to 420°C
Cooling time 250°C to 50°C in 5 min
Temperature programming rate0.1~50°C /min
Programmable oven with 4-ramp temperature control
Dual opening door at the back of column oven
Injector System
Operating temperature ambient to 420°C
Thermal conductivity detector (TCD)
Maximum Temperature 420°C
Sensitivity ≥ 12000mv*mL/mg (for butane)
Linear range 10
Current range 50 to 400mA
Filament Protection
If He or H carrier gas flow in the detector cell is cut off for 4 minutes, filament power will be shut off automatically
Flame Ionization detector (FID)
Maximum Temperature: 420°C
Minimum detectivity ≤1.3 x 10-¹² g/s (n-C16)
Linear range10
Flameout hint: Monitoring the status of GC continuously after being turned on.
Electron capture detector - ECD
Maximum Temperature 420°C
Minimum detectivity ≤0.1 pg/mL (y-666)
Linear range 10
Emission source 11mC63Ni
Flame Photometric detector-FPD
Maximum Temperature 420°C
Minimum detectivity [P] ≤1 x 10-¹² g/s (tributyl phosphate)
 [S] ≤1 x 10-¹° g/s (p-methyl sulphur phosphorous)
 
Linear range [P]:10 [S]:10³
Two air-hydrogen flames for large volume injection or trace sample injection analysis;
Single air-hydrogen flame sulphur sensitivity can be increased
Direct output for phosphorus or sulphur analysis
Square root output for sulphur analysis
Exposed light protection
When exposed light current is more than 12µA, high voltage will be cut off automatically



Additional Information:

  • Item Code: SP3400

View Complete Details

Yes, I am interested!

Gas Chromatography
Interested in this product?
Get Best Quote

Gas Chromatography

Get Latest Price

Column Oven
Operating temperatureambient to 400°C
Cooling time250°C to 50°C in 5 min
Temperature programming rate0.1~50°C /min
Programmable oven with 4-ramp temperature control
Dual opening door at the back of column oven
Injector System
Operating temperatureambient to 400°C
Thermal conductivity detector (TCD)
Maximum Temperature400°C
Sensitivity≥ 10000mv*mL/mg (for butane)
Linear range10
Current range50 to 400mA
Filament Protection
If He or H carrier gas flow in the detector cell is cut off for 4 minutes, filament power will be shut off automatically
Flame Ionization detector (FID)
Maximum Temperature400°C
Minimum detectivity≤ 5 x 10-¹² g/s (n-C16)
Linear range10
Flameout hint:monitoring the status of GC continuously after being turned on.
Electron capture detector - ECD
Maximum Temperature400°C
Minimum detectivity≤0.1 pg/mL (y-666)
Linear range10
Emission source11mC63Ni
Flame Photometric detector-FPD
Maximum Temperature400°C
Minimum detectivity:[P] ≤2 x 10-¹² g/s (tributyl phosphate)
[S] ≤2 x 10-¹° g/s (p-methyl sulphur phosphorous)
Linear range[P]:10 [S]:10³
Two air-hydrogen flamesFor large volume injection or trace sample injection analysis
Single air-hydrogen flame:sulphur sensitivity can be increased;
Direct outputfor phosphorus or sulphur analysis
Square root outputfor sulphur analysis
Exposed light protection
When exposed light current is more than 12µA, high voltage will be cut off automatically


Additional Information:

  • Item Code: SP3420A

View Complete Details

Yes, I am interested!

HPLC Column Heater
Interested in this product?
Get Best Quote

HPLC Column Heater

Get Latest Price

Features

  • Super-size column heater: Ambient size 145mm × 380mm × 110mm (W × H × D)
  • Three options of column height
  • A powerful fan that can speed up the heating process and make complete circulation of the heat.
  • Accurate temperature control and display: Microprocessor-controlled temperature device allows temperature accuracy to ±1ºC.
  • Easy installation with magnetic door frame.
  • Easy for observation: Transparent window is easy for monitoring the heating process.
  • Safe anti-leaking design: A container placed under heating chamber can prevent liquid from leaking
  • Smooth pipe: Provide smooth connection between input and output ports to guarantee that liquid can pass through.

Specfications

ModelHPLC CH-600 Column Heater
Temperature RangeRoom temperature to 75ºC
Max Temperature85ºC
Temperature Increment±1ºC
Temperature Control Accuracy±0.3ºC
Temperature Stability±0.2ºC
Display3-digit LED Actual Temperature Display (Red)
3-digit LED Set Temperature Display (Green)
Power Consumption300W
External Dimensions (W × D × H)185mm × 172mm × 530mm
Column Dimensions (W × D × H)145mm × 110mm × 380mm

 



Additional Information:

  • Item Code: CH600

View Complete Details

Yes, I am interested!

Peltier Temperature Control System To Uv Spectrometer
Interested in this product?
Get Best Quote

Features

The Peltier Temperature Control System is compatible to Cromtech make Single and Double Beam UV Spectro Photometer.

Specifications.

Temperature range10 °C ~ 80°C (room temperature)
Temperature accuracy0.1 °C
Sample position1
Cell available0.5cm 1cm, 2cm, 3cm, 4cm
Operating temperature5 °C ~ 35 °C
Relative Humidity< 85%
Power Supply100 ~ 240V, 50/60Hz
Power85W
Size (in mm)334 x 248 x 197
Net Weight7.2 Kgs

 

View Complete Details

Yes, I am interested!

IR Spectrometer
Interested in this product?
Get Best Quote

IR Spectrometer

Get Latest Price

Features

  • High Stability
  • High Accuracy and Reliability
  • Practical Analytical Software
  • Various Accessories
  • Liquid Sample Accessories
  • IR Microscope
  • Diffuse/Specular Reflectance Accessory
  • Horizontal ATR (Single-reflection and Multi-reflection) /Variable Angle ATR (30 0 – 60 0)
  • Accessory for Determination of Hydroxyl in IR Quartz
  • Accessory for Oxygen and Carbon in Silicon Crystal Determination
  • Sio 2 Power Dust Monitoring Accessory
  • Component Testing Accessory
  • Optic Fiber testing Accessory
  • Jewelry Inspection Accessory

Specifications

  • Spectral Range: 7800 to 400 cm-1
  • Resolution: Better than 0.85cm-1 (WQF-510, Better than 0.5cm-1 (WQF-520)
  • Wave number Precision: ± 0.01 cm-1
  • Scanning Speed: 0.2-2.5 cm-1/s, automatically optimized for detector type or manually adjustable for specific applications
  • Signal to Noise Ratio : Better than 15,000 : 1 (RMS value, at 2100cm-1 or 2100cm-1 – 2200cm-1, resolution : 4cm -1, detector : DTGS, 32 times data collection)
  • Beam Splitter: Ge coated KBr
  • Infrared Source: External, air-cooled, high efficiency Reflex sphere module
  • Detector: DTGS, MCT (optional)
  • Data System: Compatible computer
  • Software: FT – IR software contains all routines needed for Basic spectrometer operations.
  • IR Library: 11 IR libraries including
  • Dimensions: 63X52X24cm
  • Power        : AC : 220V/50HZ, 1000VA
  • Weight       : 20kg.


Additional Information:

  • Item Code: WQF510-520FT

View Complete Details

Yes, I am interested!

Optical Emission Spectrometer
Interested in this product?
Get Best Quote

Applications

WLD – 4C OPTICAL EMISSION SPECTROMETER can be widely used in the fields of casting, metallurgy, machine manufacturing, shipbuilding, automobile manufacturing, and chemical industry etc. It is a necessary instrument for on – the sport sample analysis in metallurgy plants and for metal material inspection in quality inspection labs etc.

Features

  • Various metal bases can be analyzed: ferrous metals of Fe, Co, Ni and Ti base, and non-ferrous metals of Cu, Al, Pb, Mg, Zn and Sn base.
  • Adopting the exciting source with high reproducibility and stability. The exciting frequency can be changed in the range of 150 – 600Hz to match the material to be analyzed and get the best analytical result.
  • Adopting highly integrated data collecting and controlling system with high automation.
  • High-speed analysis with high antijamming ability, good reproducibility and stability.
  • Reasonable design with more integrated construction.
  • Windows based software with easy and simple operation.
  • In-built data base allowing long-distance data transfer.
  • Quality control diagram can be established automatically for easy quality control and monitoring.
  • High vibration resistance ability. It’s not necessary to make vibration resistance base.
  • Partial thermostat system for fewer requirements to the environment.

Instrument Composition

  • Thermostat system
  • Spectroscope system
  • Vacuum system
  • Gas-filling system
  • Exciting source
  • Argon supply system
  • Measurement and control  system
  • Data Processing system

Technical Data

Exciting source:
  • Power Voltage: 50Hz, 220V ± 10%
  • Input Power: 1.0 kVA

Spectroscope:

  • Spectral range 175 – 450nm
  • Grating: 2400 L/mm concave grating in radius of 0.75m;
  • Blazed at 300 nm (1st order); Ruled Area: 30x50mm2;
  • Reciprocal Linear dispersion: 0.55nm/mm;
  • Entrance slit width: 20um
  • Exit slit width:  50/75um
  • Maximum number of channel:  36
  • Constant temperature  :  300 C ± 0.10C

Measurement and Control System

  • Measuring mode : sectional integration
  • Measuring reproducibility : RSD ≤ 0.2%
  • PMT high voltage power supply :   Voltage:- -1000v,
  • Stability : better than 0.5% (8h)
  • PMT high voltage adjustment : controlled by PC

Data Processing System

  • Industrial controlled built in PC LCD display.
  • Software:  under Windows Operating System.

Dimensions:

  • Main Unit : 1500(L) x 1000(D) x 1200 (H) mm
  • Area required  :  15-20 square meters
  • Weight  :  about 450kg

Laboratory Requirements:

  • Environment : temperature : 200C ± 50C ; relative humidity : < 70%
  • Purity of Argon gas  : 99.999%
  • Power supply : AC 380V ± 10% 50Hz 3KW, 3-phase, 4-line.
  • Ground Lead: An independent ground lead should be used for the spectrometer itself. Grounding wire resistance < 2 ohm.

 

 

 