Ventilator ICU
Tidal Volume | adult : 100 to 2000 ml,For Pediatric 20 to 300 ml |
Respiratory Rate | 1 to 100 RPM |
Brand | Mindray |
Model Name/Number | SV300 |
Usage/Application | ICU& PORTABLE |
Patient Age Group | Adult, Pediatrics |
- Compact yet powerful
- Adaptive
- Comprehensive
Equipped with functions that are usually found on intensive care ventilators, the SV300 comes with extensive ventilation modes and unique features that make it a top level ventilator.
- Simple
Thanks to the intuitive UI design of the SV300, each function is in logical order so that clinicians do not need to navigate a complex menu. In addition, both the valves and flow sensor support autoclaving. This safety concept is designed to meet the current clinical trends of protecting patients even under the most demanding conditions.
Additional Information:
- Item Code: SV300
View Complete Details
Mindray Synovent E5 Hospital Ventilator
Get Latest Price
Brand | Mindray |
Model Name/Number | Synovent E5 |
Patient Age Group | Adult, Pediatrics & Neonatal |
Tidal Volume | Adult : 100 to 2000 ml,For Pediatric 20 to 300 ml |
Ventilation Mode | V-A/C, P-A/C, V-SIMV, P-SIMV, Duolevel, CPAP, PSV, NIV, (APRV,PRVC options) |
Respiratory Rate | 1 to 150 bpm |
The SynoVent E5 ventilator is developed with features that can meet all your needs. It not only provides advanced ventilation modes and functionality for patients ranging from infant to adult, but also features a modern, easy-to-use interface to enhance the efficiency of your clinical workflow.
Thanks to the intuitive user interface, it allows quick and easy control over ventilator parameters and settings. The 12.1 inch screen can display up to 4 simultaneous waveforms or 2 loops. With a smartly designed user interface that combines a touch screen with direct access knobs, users can quickly learn to navigate the SynoVent E5 and put all of its features into clinical use.
E5 ventilator supports invasive, non-invasive ventilation and high flow O2 therapy, which can fulfill different clinical needs. It supports multiple advanced ventilation modes, such as Duolevel, APRV, PRVC and PRVC-SIMV. Mindray’s leading gas analysis technology can be integrated to enable EtCO2 monitoring.
The SynoVent E5 also ensures data continuity by connecting to Mindray patient monitors through the BeneLink and e-Gateway modules. In this way, the ventilation data can be transferred seamlessly to the HIS and CIS systems with ease.
The optional C3 compressor can be integrated to secure ventilation in an environment without central gas supply. The SynoVent E5 can also be configured for mounting on a trolley or a pendant to further adapt to different clinical scenarios.
View Complete Details
Brand | Mindray |
Model Name/Number | Synovent E3 |
Tidal Volume | Pediatric: 40~300 ml (increments of 1 ml),Adult:-100~2000 ml (increments of 10 ml) |
Features
The SynoVent E3 ventilator provides advanced ventilation modes and functionality, as well as a modern, easy-to-use interface to enhance the efficiency of your clinical workflow.
With intuitive user interface, it allows quick and easy control over ventilator parameters and settings. The 10.4 inch screen can display up to 3 simultaneous waveforms or 2 loops. With a modern user interface that combines a touch screen with direct access knobs, the user can quickly learn to navigate the SynoVent E3 and put all of its features into clinical use.
With support for invasive, non-invasive ventilation and high flow O2 therapy, the E3 can fulfill different clinical needs. It supports multiple advanced ventilation modes, such as Duolevel, APRV, PRVC and PRVC-SIMV. Mindray’s leading gas analysis technology can be integrated to enable EtCO2 monitoring.
The SynoVent E3 also ensures data continuity by connecting to Mindray patient monitors through the BeneLink and e-Gateway modules. In this way, the ventilation data can be transferred seamlessly to the HIS and CIS systems with ease.
The optional C3 compressor can be integrated to secure ventilation in an environment without central gas supply. The SynoVent E3 can also be configured for mounting on a trolley or a pendant to further adapt to different clinical scenarios.
View Complete Details
Product Details
Brand | Maquet |
Model Name/Number | Servo-i |
Patient Age Group | Adult, Infant |
Tidal Volume | Infant: 2-350 ml, Adult: 100-4000 ml |
Ventilation Mode | PC, VC, PRVC, PS/CPAP, VS, SIMV (VC) + PS, SIMV (PC) + PS, SIMV (PRVC) + PS, Bi-Vent/APRV |
Respiratory Rate | 1-160 bpm |
Additional Details
Operating Temperature | +10 to +40ºC |
Power Supply | 100 - 120 V AC ±10%, 50 - 60 Hz or 220 – 240 V AC ±10%, 50 - 60 Hz |
Display Size | 31 cm (12.1 inch) diagonal |
Display Type | TFT-LCD module |
Battery Back Up | At least 3 hours, when using six batteries |
Weight | Approximately 20 kg (Patient Unit 15 kg, User Interface 5 kg) |
Features
- Open Lung Tool & Heliox System
- Ensure maximum uptime
- Patient data at your fingertips
- Full monitoring capabilities
- On-screen diaphragm EMG
Application
- Emergency Care & ICU
A single ventilator to treat every patient, everywhere
Servo-i delivers a high level of clinical performance for a variety of situations and for all patients. This helps clinicians provide cost-effective care throughout the hospital.
Personalized Ventilation
Servo ventilators equipped with NAVA can display your patient's diaphragm activity on screen, so you can improve patient-ventilator synchrony and comfort. This can lead to reduced need for sedation, fewer complications and shorter weaning periods.
A complete spectrum of treatment opportunities
Servo-i features all the modes you would expect from an advanced ventilation system in one adaptable platform. It also presents a wide range of tools to help you stabilize your patient and wean them off the ventilator.
Stress Index
Stress Index can help the clinician detect and prevent harmful ventilatory patterns, such as barotrauma, i.e. overdistension of the airways and lungs.
Open Lung Tool
The Open Lung Tool makes it easier to assess recruitment efficacy. On-screen values, such as dynamic compliance, assists you during lung recruitment and PEEP titration.
Heliox
Heliox minimizes turbulence and improves CO2 elimination. Easing the work of breathing for patients from neonate to adult. It can be used in all modes of ventilation.
Automode
Automode helps your patients' transition into spontaneous breathing with less need for staff intervention. It is an interactive mode that switches between controlled and supported ventilation conditional to patient effort.
On-screen diaphragm EMG
The electrical activity of the diaphragm (Edi) shows you the patient's breathing effort, breath by breath. It helps you titrate sedation and identify the best level of support at all times and during any mode of ventilation.
NAVA and NIV NAVA
Neurally Adjusted Ventilatory Assist (NAVA) promotes lung protective spontaneous breathing with higher diaphragmatic efficiency, and fewer periods of over- and under-assist. This can help you reduce sedation with higher comfort scores and improved sleep quality.
MR Conditional
Servo-i MR provides continuity of care for critically ill patients throughout the MR process. Full trigger sensitivity and a range of ventilation options are available for use with all patient categories.
HBO Conditional
Servo-i HBO can provide ICU-quality ventilation in the hyperbaric chamber. It has full monitoring capabilities and delivers ventilation down to a depth of 30 meters. It is available for all patient categories.
Ensure maximum uptime
Optimizing your equipment's services is often an untapped opportunity to maximize productivity and reduce costs. Our Getinge Care service offering will ensure that your equipment always perform at peak levels allowing you to focus on what’s important - saving lives.
High quality consumables
We offer an extensive range of readily available consumables designed with patient safety and ease of use in mind- all to help secure your everyday operations.
Patient data at your fingertips
MSync helps you to connect your Servo fleet to your patient monitor, HIS or patient data management system (PDMS). Clinical and patient data is transferred in real time to support clinical decision-making.
View Complete Details
Product Details
Brand | Mindray |
Model Name/Number | SV300 |
Patient Age Group | Adult, Pediatrics |
Tidal Volume | For adult : 100 to 2000 ml, For Pediatric 20 to 300 ml |
Ventilation Mode | V-A/C, P-A/C, V-SIMV, P-SIMV, Duolevel, CPAP, PSV, APRV, PRVC, NIV |
Respiratory Rate | 1 to 100 RPM |
Additional Details
Weight | 10 kg |
Plateu (%) | OFF, 5% to 60% |
Peak airway pressure | 5 to 80 cm H2O |
SIMV Rate ,Cycle/min | 1 to 60 rpm |
Mounting type | Trolley |
I:E Ratio | 4:1 to 1:10 |
Touch screen | Angle adjustable 12.1 inch color TFT touch screen |
RSBI | 0-999/1/(L-min) |
Features
- ICU package options
- Extensive monitoring
- Volumetric CO2 measurement
- Weaning indicators
View Complete Details
Product Details
Brand | Mindray |
Model Name/Number | Synovent E3 |
Patient Age Group | Adult, Pediatrics & Neonatal |
Tidal Volume | For adult : 100 to 2000 ml, For Pediatric 40 to 300 ml |
Ventilation Mode | V-A/C, P-A/C, V-SIMV, P-SIMV, Duolevel, CPAP, PSV |
Respiratory Rate | 1 to 120 bpm |
Additional Details
Weight | 20 kg+ 27 kg trolley |
Peak airway pressure | 0 to 100 cm H2O |
SIMV Rate ,Cycle/min | 1 to 60 rpm |
Mounting type | Trolley + Compressor |
I:E Ratio | 4:1 to 1:10 |
Touch screen | 10.4 inch color active matrix TFT touch screen |
Features
- Individual lock of front casters
- Pressure sensor test
- Inspiratory hold
View Complete Details
Product Details
Brand | Mindray |
Model Name/Number | Synovent E5 |
Patient Age Group | Adult, Pediatrics & Neonatal |
Tidal Volume | For adult : 100 to 2000 ml, For Pediatric 20 to 300 ml |
Ventilation Mode | V-A/C, P-A/C, V-SIMV, P-SIMV, Duolevel, CPAP, PSV, NIV, (APRV,PRVC options) |
Respiratory Rate | 1 to 150 bpm |
Additional Details
Weight | 25 kg + 23 kg (trolley) |
Peak airway pressure | 0 to 100 cm H2O |
SIMV Rate ,Cycle/min | 1 to 60 rpm |
Mounting type | Trolley + Compressor |
I:E Ratio | 4:1 to 1:10 |
Touch screen | 12.1 inch color active matrix TFT touch screen (separable 180° rotation and 45° tilt ) |
Features
- Airway pressure too high/low
- Airway obstruction
- Sustained airway pressure
- Tube disconnected
- Power supply voltage error
View Complete Details
Product Details
Brand | GE |
Model Name/Number | Carescape R860 |
Patient Age Group | Adults, Pediatric Patients, Neonatal |
Tidal Volume | Adult: 100 to 2000 ml, Pediatric: 20 to 300 ml Neonatal: 2 to 50 ml |
Ventilation Modes | A/C VC, A/C PC, A/C PRVC, SIMV VC, SIMV PC, CPAP/PS, SBT, APRV, BiLevel, BiLevel VG, SIMV PRVC, VS, NIV, nCPAP |
Respiratory Rate | Neonatal: 3 to 150 bpm for A/C VC, A/C PC, A/C PRVC; 2 to 60 bpm for SIMV VC, SIMV PC, SIMV PRVC; Off, 1 to 30 bpm for nCPAP Adult/Pediatric: 3 to 120 bpm for A/C VC, A/C PC, A/C PRVC; 1 to 60 bpm for SIMV VC, SIMV PC, SIMV PRVC |
Controls
Trigger | Flow trigger:- Neonatal: 0.2 to 1 L/min (increments of 0.05 L/min), 1 to 3 L/min (increments of 0.1 L/min), 3 to 9 L/min (increments of 0.5 L/min); Adult/Pediatric: 1 to 3 L/min (increments of 0.1 L/min), 3 to 9 L/min (increments of 0.5 L/min) Pressure trigger:- Adult/Pediatric: –10 to –3 cm H₂O (increments of 0.5 cm H₂O), –3 to –0.25 cm H₂O (increments of 0.25 cm H₂O) |
Pressure Support | 0 to 60 cm H₂O for SIMV VC, SIMV PC, SIMV PRVC, BiLevel, BiLevel VG and CPAP/ PS (increments of 1 cm H₂O), 0 to 30 cm H₂O for NIV (increments of 1 cm H₂O) |
Flow | Neonatal: 0.2 to 30 L/min, Pediatric: 2 to 72 L/min, Adult: 2 to 160 L/min |
Maximum Peak Flow | Adult: 208 L/min; Pediatric: 100 L/min; Neonatal: 30 L/min |
Inspiratory/ Expiratory Ratio | Neonatal: 1:199 to 40:1 in BiLevel and APRV, Adult/Pediatric: 1:79 to 60:1 in BiLevel and APRV |
Trigger Window | 80% of expiration time |
Bias Flow Rate | Neonatal: 2 to 15 L/min (increments of 0.5 L/min) for nCPAP; Adult/Pediatric: 2 to 10 L/min (increments of 0.5 L/min), 8 to 20 L/min for NIV (increments of 0.5 L/min) |
Settings
Inspiratory Pressure | Neonatal: 1 to 25 cm H₂O (increments of 1 cm H₂O) in nCPAP; Adult/Pediatric: 1 to 98 cm H₂O (increments of 1 cm H₂O) |
PEEP/CPAP | PEEP:- Neonatal: 2-15 cm H₂O (increments of 1 cm H₂O) in nCPAP Adult/Pediatric: Off, 1 to 50 cm H₂O (increments of 1 cm H₂O), 2-20 cm H₂O (increments of 1 cm H₂O) in NIV |
Inspiratory time | Neonatal: 0.1 to 10 sec, 0.1 to 2 sec in nCPAP, 0.1 to 1 sec (increments of 0.01), 1 to 4 sec (increments of 0.1), 4 to 10 sec (increments of 0.25) Adult/Pediatric: 0.25 to 15 sec, 0.25 to 5 sec in NIV, 0.25 to 1 sec (increments of 0.05), 1 to 4 sec (increments of 0.1), 4 to 15 sec (increments of 0.25) |
Expiratory time | Neonatal: 0.25 to 29.9 sec Invasive vent modes, Adult/Pediatric: 0.25 to 59.75 sec |
Monitoring
Peak Inspiratory Pressure | 7 to 100 cm H₂O (increments of 1 cm H₂O), 9 to 100 cm H₂O (increments of 1 cm H₂O) in NIV and nCPAP |
Ambient Conditions
Temperature (device) During Operation | 10° to 40°C |
Relative humidity During Operation | 15 to 95% RH Non-condensing |
Altitude | Operating range: –400 to 3000 m/525 to 800 mmHg , Storage range: –400 to 5860 m/375 to 800 mmHg |
Temperature During Storage & Transportation | –20° to 60°C |
Relative humidity During Storage & Transportation | 15 to 75% RH Non-condensing |
Performance
Intermittent PEEP | High: 1 to 20 cm H2O, Off |
Minute volume | Low: 0.01 to 40 L/min, High: 0.02 to 99 L/min |
Operating Data
Power Consumption | < 200 VA |
Dimensions | 151.77 x 38 x 36 cm |
Weight | 31 kg (not including cart), 78 kg (including cart) |
Power Supply
Battery Type | Lead acid gel |
Alarm
Inspiratory O₂ concentration (FiO₂) | Low: 18 to 99%, High: 24 to 100%, Off |
Airway Pressure | –20 to +120 cm H₂O |
Apnea alarm time | 5 to 60 seconds |
Audible Alarm Volume Adjustable | 0, 10, 20 and 30 sec, Off |
High Inspiratory Pressure | 1 to 98 cm H₂O (increments of 1 cm H₂O) |
Low Inspiratory Pressure | Off, 1 to 50 cm H₂O (increments of 1 cm H₂O) |
High Respiratory Rate | 2 to 150/min, Off |
Circuit Leak | 10 to 90%, Off |
Escalating Alarms | High priority alarms escalate to a higher pitch if unattended for specified time |
Auto Limits | Alarm limits calculated on the current measured values for selected parameters |
Display Motion
Vertical Tilt | 162.1° in raised position, 47.6° in lowered position |
Height Adjustment | 24.95 cm / 9.8 inch |
Additional Details
Inspiratory Pressure Limit | 7 to 100 cm H₂O for A/C VC and SIMV VC (increments of 1 cm H₂O) |
CO₂ production (VCO₂) | 20 to 1000 mL/min |
Rise time | 0 to 500 ms of inspiratory period for pressure supported breaths only. Active in SIMV VC, SIMV PC, SIMV PRVC, CPAP/PS, BiLevel VG, BiLevel and VS (increments of 50 ms) |
Features
- Lung Protection Strategy
- Innovative user interface
- Menu-free navigation
- Measuring Functional Residual Capacity
Application
- Emergency Care & ICU
Featuring expert user tools and an innovative user interface, the Carescape R860 is inherently familiar the first time you use it.
Navigating past, present and future states of your ventilated patients is the foundation of the Carescape R860 user interface. From the center workspace view that highlights current patient status, you can swipe left to right to navigate from historical trends on the left (past) to Clinical Decision Support tools on the right (future). Your settings are recalled even as you navigate across workspaces.
By replacing menus with workspace views, the Carescape R860 has flattened the learning curve and unlocked ventilation capabilities by making them more accessible and easier to use.
View Complete Details
- Developed and Managed by IndiaMART InterMESH Limited