Flame Sensor D-Le 603, D-Le 603 Ex
Ask For Price

Flame Sensor D-Le 603, D-Le 603 Ex

Get Price

Flame sensor for the monitoring of gas, oil and coal flames, primarily in multi-burner furnces

Features

Self-monitoring and fail-safe in conjunction with a control unit/burner control

Flame sensors for every spectral range from UV to IR

Connection to the D-UG 120 control unit, D-UG 660 control unit as well as to the D-GF 150 burner control

Uniform output signal thus mutually interchangeable

Adjustable to different combustion technologies such as exhaust gas recirculation

Compliance to general safety regulations

ATEX approved (D-LE 603 Ex)

Applications

Power stations
Chemical industry
Refineries

Cement plants

Waste incinerators
Steam generators

Heating plants.

Yes! I am interested

Request Callback
Flame Sensor D-Le 103
Ask For Price

Flame Sensor D-Le 103

Get Price

Flame sensors for the monitoring of gas, oil and coal flames, primarily in single burner furnaces

Features

Self-monitoring and fail-safe in conjunction with a control unit/burner control

Flame sensors for every spectral range of flame monitoring from UV to IR

Connection to D-UG 120 and D-UG 660 conztol unit as well as D-GF 150 burner control

Uniform output signal thus mutually interchangeable

Compliance to general safety regulations

Applications

Power stations

Chemical industry

Refineries

Cement plants

Waste incinerators

Steam generators

Heating plants.

Yes! I am interested

Request Callback
Flame Sensor
Ask For Price

Flame Sensor

Get Price

System for flame monitoring:
D-LE 701 flame sensor
with rigid fibre optic system
D-LL 702

Features flame sensor




Self-monitoring and fail-safe flame sensor with a fibre-optic connection in conjunction with a control unit/burner control


Monitoring of gas, oil and coal flames


Connection to the D-UG 120, D-UG 660 control unit and the D-GF 150 burner control


Spectral range from UV to IR


Uniform output signal thus mutually interchangeable


Adjustable to different combustion technologies such as exhaust gas recirculation



Features of fibre optic system




Rigid fibre optic system


Separate design, flame sensor and fibre optic system are connected by fibre optic bundle protected by conduit system


Suitable for temperatures up to 350°C


Applications




Burners with difficult installation conditions for conventional flame sensors or on those whose environmental temperature near the sighting tube is too high

Power stations


Chemical industry


Refineries


Cement plants


Waste incinerators


Steam generators


Heating plants

Yes! I am interested

Request Callback
Flame Sensor With Optical System D-Le 703, D-Ll703/704
Ask For Price

Flame Sensor With Optical System D-Le 703, D-Ll703/704

Get Price

System for monitoring flames:
D-LE 703 flame sensor
with flexible fibre optic system
D-LL 703
with rigid fibre optic system
D-LL 704

Features of the flame sensor

Self-monitoring and fail-safe flame sensor with a fibre-optic connection in conjunction with a control unit/burner control

Monitoring of gas, oil and coal flames

Connection to the D-UG 120, D-UG 660 control unit and the D-GF 150 burner control

Spectral range from UV to IR

Uniform output signal thus mutually interchangeable

Uniform design, the flame sensors are mounted directly on the flame sensor

Adjustable to different combustion technologies such as exhaust gas recirculation

Features of the D-LL 703 fibre optic system

flexible fibre optic system

suitable for temperatures up to 350°C.

Features of the D-LL 704 fibre optic system

rigid fibre optic system

suitable for temperatures up to 350°C

Applications

Tilting burner (flexible system)
Burners with difficult installation conditions for conventional flame sensors or on those whose environmental temperature near the sighting tube is too high

Power stations

Chemical industry

Refineries

Cement plants

Waste incinerators

Steam generators

Heating plants.

Yes! I am interested

Request Callback
Flame Sensor D-Gt 800
Ask For Price

Flame Sensor D-Gt 800

Get Price

Flame sensor for the monitoring of gas, oil and coal flames, primarily in gas turbines or in particularly harsh environments

Features

Optionally available with air/water cooling

Deployable with high combustion chamber overpressure

High vibrational stability

D-GT 800

Conforms to general safety regulations

Self-monitoring and fail-safe in conjunction with a control unit/burner control

Connection to the D-UG 120, D-UG 660 control unit and the D-GF 150 burner control

Yes! I am interested

Reach Us

Gmap

Durag Group No. 27/30, 2nd Main Road, Industrial Town, Rajajinagar, Opp Sujatha Kalyan Mandap,
Bengaluru-560044, Karnataka, India

Nirmala ( Receptionist )
Send SMS
Send E-MAIL

Share Us:


We are here to Help You!
Go Mobile : Follow Us On :
Copyright © 1996-2018 IndiaMART InterMESH Ltd. All rights reserved.