Common Data

tube Ø

50 mm

flame length

max. 600 mm

igniter tube length L

360 - 5000 mm

gas inlet

1/2“, left or right

gas pressure

500 mbarg

air inlet

1“, may be rotated 4 times in steps of 90°

air pressure

≥10 mbar, depending on tube length

Yes! I am interested

Request Callback
Gas Fired Igniters
Ask For Price

Gas Fired Igniters

Get Price
Common Data

tube Ø

65 mm

flame length

max. 2000 mm

igniter tube length L

240 - 10000 mm

gas inlet

3/4“, below

gas pressure

1 mbarg

air inlet

1 1/2“, may be rotated 4 times in steps of 90°

air pressure

≥15 mbar, depending on tube length

Yes! I am interested

Request Callback
Gas Fired Igniters
Ask For Price

Gas Fired Igniters

Get Price
Common Data

tube Ø

90 mm

flame length

max. 4000 mm

igniter tube length L

240 - 10000 mm

gas inlet

2“, below

gas pressure

1 mbarg

air inlet

2“, may be rotated 4 times in steps of 90°

air pressure

≥15 mbar, depending on tube length

Yes! I am interested

Request Callback
Gas Igniters(45 Kw)
Ask For Price

Gas Igniters(45 Kw)

Get Price
Common Data

tube Ø

35 mm

flame length

max. 500 mm

igniter tube length L

240 - 10000 mm

gas inlet

1/2“, left or right

gas pressure

50 - 150 mbarg

air inlet

1“, may be rotated 4 times in steps of 90°

air pressure

≥15 mbar, depending on tube length

Yes! I am interested

Request Callback
Gas Igniters(2 Kw)
Ask For Price

Gas Igniters(2 Kw)

Get Price
Common Data

tube Ø

15 mm

flame length

max. 80 mm

igniter tube length L

120 – 2400 mm

gas inlet

1/4“

gas pressure

15 – 20 mbarg

air inlet

1/4“

air pressure

15 – 20 mbarg

Yes! I am interested

Request Callback
Gas Igniters(4 Kw)
Ask For Price

Gas Igniters(4 Kw)

Get Price
Common Data

tube Ø

25 mm

flame length

max. 100 mm

igniter tube length L

120 – 4000 mm

gas inlet

1/4“

gas pressure

15 – 20 mbarg

air inlet

3/8“

air pressure

15 – 20 mbarg

Transformer part (not ZGU)

ignition

5 kV

ambient temperature

-20°C up to +80°C

protection

IP 54

Yes! I am interested

Request Callback
Gas Igniters(120 Kw)
Ask For Price

Gas Igniters(120 Kw)

Get Price
Common Data

tube Ø

48 mm

flame length

max. 600 mm

igniter tube length L

240 - 10000 mm

gas inlet

1/2“, left or right

gas pressure

50 - 150 mbarg

air inlet

1“, may be rotated 4 times in steps of 90°

air pressure

≥15 mbar, depending on tube length

Yes! I am interested

Request Callback
Gas Igniters(250 Kw)
Ask For Price

Gas Igniters(250 Kw)

Get Price
Common Data

tube Ø

65 mm

flame length

max. 1200 mm

igniter tube length L

240 - 15000 mm

gas inlet

3/4“, above or below

gas pressure

50 - 150 mbarg

air inlet

1½“, may be rotated 4 times in steps of 90°

air pressure

≥10 mbar, depending on tube length

Yes! I am interested

Request Callback
Gas Igniters(1000 Kw)
Ask For Price

Gas Igniters(1000 Kw)

Get Price
Common Data

tube Ø

135 mm

flame length

max. 2000 mm

igniter tube length L

300 - 10000 mm

gas inlet

2“, above or below

gas pressure

50 - 150 mbarg

air inlet

DN 80 PN 6, may be rotated in steps of 90°

air pressure

≥5 mbar, depending on tube length

Yes! I am interested

Request Callback
Gas Igniters(2000 Kw)
Ask For Price

Gas Igniters(2000 Kw)

Get Price
Common Data

tube Ø

160 mm

flame length

max. 3000 mm

igniter tube length L

300 - 4000 mm

gas inlet

2“, above or below

gas pressure

50 - 150 mbarg

air inlet

DN 100 PN 6, may be rotated in steps of 90°

air pressure

≥5 mbar, depending on tube length

Yes! I am interested

Request Callback
Gas Igniters For Hazardous Area(45/120 Kw)
Ask For Price

Gas Igniters For Hazardous Area(45/120 Kw)

Get Price
Common Data

tube Ø

35 / 50 mm mm

igniter tube length L

240 - 5000 mm

gas inlet

1/2“, left or right

gas pressure

50 - 150 mbarg

air inlet

1“, may be rotated 4 times in steps of 90°

air pressure

≥10 mbar, depending on tube length

transformer part

for zone 2
pressure proof enclosure,
II3 G EEx nC IIC T5, tu max 60°C

ambient temperature

-20°C up to +60°C

Protection

IP 65

Yes! I am interested

Request Callback
Gas Igniters(250 Kw)
Ask For Price

Gas Igniters(250 Kw)

Get Price
Common Data

tube Ø

ZAPF 52 mm
ZA0F 74 mm
ZA1F 86 mm

flame length

depending on igniter size

igniter tube length L

800 - 5000 mm

gas pressure

50 - 150 mbarg

Yes! I am interested

Request Callback
Gas Igniters(600 Kw)
Ask For Price

Gas Igniters(600 Kw)

Get Price
Common Data

tube Ø

90 mm

flame length

max. 2000 mm

igniter tube length L

240 - 10000 mm

gas inlet

1“, above or below

gas pressure

50 - 150 mbarg

air inlet

2“, may be rotated 4 times in steps of 90°

air pressure

≥15 mbar, depending on tube length

Yes! I am interested

Request Callback
Self Aspirated Gas Igniters(20 Kw)
Ask For Price

Self Aspirated Gas Igniters(20 Kw)

Get Price
Common Data

tube Ø

35 mm

flame length

max. 300 mm

igniter tube length L

240 - 10000 mm

gas inlet

1/2“, left or right

gas pressure

0,5 - 2,5 barg

Transformer part

Yes! I am interested

Request Callback
Self Aspirated Gas Igniters(40 Kw)
Ask For Price

Self Aspirated Gas Igniters(40 Kw)

Get Price
Common Data

tube Ø

50 mm

flame length

max. 500 mm

igniter tube length L

240 - 10000 mm

gas inlet

1/2“, left or right

gas pressure

0,5 - 2,5 barg

Yes! I am interested

Reach Us

Gmap

DURAG INDIA INSTRUMENTATION PRIVATE LIMITED No. 27/30, 2nd Main Road, Industrial Town, Rajajinagar, Opp Sujatha Kalyan Mandap,
Bengaluru-560044, Karnataka, India

Nirmala ( Receptionist )
Send SMS
Send E-MAIL

Share Us:


We are here to Help You!
Go Mobile : Follow Us On :
Copyright © 1996-2018 IndiaMART InterMESH Ltd. All rights reserved.