Level Measurement

Offering you a complete choice of products which include ELIXIR Liquid Level Switch, Solid Level Measurement Switch, Vibrating Rod Level Switch, Pipe Fork Vibrating Fork Level Switch, Capacitance Level Switch and Capacitance Level Sensor.

ELIXIR Liquid Level Switch
Interested in this product?
Get Best Quote
Elixir is a microprocessor based liquid level switch which consumes low power and can be used for liquids up to 10000 cP and is suitable up to temperature limits of 200°C. This single-point liquid indicator is extremely compact making it suitable for constricted places.

Elixir level switch uses the RISC Core micro-controller technology which makes it reliable & more accurate for level detection of any liquid or slurry (even highly viscous up to 10,000 cP). The instrument has an adjustable switching delay for covered and uncovered conditions. The electronics is integral with the fork and can be mounted in different ways such as top or side mounting. If the use is in hazardous area, you could choose the Flame proof version. You also have the flexibility of choosing the insertion length.

Applications:

You can use Elixir for level detection of all types of liquids in storage tanks, mixing tanks and pipe lines having temperature up to 200°C and viscosity up to 10,000 cP and density greater than 0.7 gm/cc. Elixir is suitable for most of the applications, where traditional float switches were previously used and for liquids, which are sticky, corrosive, agitated, splashing and foaming.

Where is it used:

Elixir has well used in the edible oil, food, pesticides, power, pharmaceutical, chemicals, dairy, distelleries, sugar, detergent, minerals, textile, water and many other industries and their utilities.

Principle:

A specially shaped tuning fork is kept vibrating by piezo-electric elements at a set frequency. The frequency of the vibrating fork changes when the tines are immersed in the liquid. The change in the frequency is detected and used for switching a relay. The output contacts of the relay can in turn be used for annunciation or control.

Technical Data

Evaluation Unit

HousingCast aluminum weather-proof and Flameproof suitable for mounting in hazardous area Gas group IIA, IIB & IIC as per IS-2148
Cable Entries2 Nos.
Mains19 to 260 V AC, 50/60 Hz & 11 to 55 VDC
OutputOne set (1 SPDT) of potential free change over contacts rated at 6A 230V AC & 6A 25 VDC for non-inductive load. (DPDT OPTIONAL)
Time DelayAdjustable from 1 to 20 second for probe covered & uncovered condition.
IndicationRed LED for alarm and Green LED for normal condition.
Power Consumption5 VA approx.
Response Time1 second. approx.
Operating Temp.-20ºC to +60ºC
Fail-Safe ModeHigh or Low field selectable.

Probe

Tuning ForkStainless steel 316
Mounting1" or 1½" BSP screwed (flanged mounting on request). 1½" BSP for high temperature version.
ExtensionStainless steel pipe.
Probe LengthMin. 128 mm, max. 3500 mm.
Operating-20º C to + 80º C.
TemperatureStandard models (high temp. models up to 200º C are also available.)
ViscosityUp to 10000 cP.
DensityGreater than 0.7gm/cc.

View Complete Details

Yes, I am interested!

Solid Level Measurement Switch
Interested in this product?
Get Best Quote

This tuning fork level switch from Sapcon Instruments, known as the SLM series, is best suited for you if your operational unit involves level limit detection of

  • Fine grained free flowing solids including very low density and pneumatically conveyed media, powders, plastic chips, cement, sand, sugar, food grains
  • For detecting level of granular solid material submerged in liquids of low viscosity, like sand, gravel, plastic chips under water.
  • For applications requiring the processing of different type of material in the same vessel.

Features (SLM Series)

The SLM series tuning fork level detector has no moving parts and requires no calibration. The High/Low selection feature is available as a standard feature unlike the instruments from other manufacturers. The SLM level switch is insensitive to material build-up and isn't affected by the electrical properties of the service material.

Principle of Operation:

A top or side mounted, stainless steel made tuning fork is kept in mechanical vibration at the resonance frequency by piezo ceramic elements. When the service material covers the tines of the tuning fork, vibrations are damped. This is sensed electronically and processed signal is used to energize a relay whose contacts in turn are used for annunciation or control. Two basic type of constructional arrangements are available. One, where the electronics is separated from the fork, the other has them integrated. You can choose from: Mounting arrangement of your choice (screwed or flanged type).

 

Microprocessor based compact level detector for Solids:

The Sapcon Humming Bird is a compact solids level switch.  

Technical Data:

Evaluation Unit:

HousingCast Aluminum, weather proof, back panel (wall mounting) / Integral.
Cable Entry3 No. / 2 No.
Max. Amb. Temp-20º C to +60º C.
Power Consumption5 VA approx.
Mains Voltage230 V or 110 V AC (-15% to +10%), 50/60 Hz; 24 V AC/DC; 90 to 260 V AC universal power supply
Relay OutputOne/two set (s) of potential free change over contacts rated at 230V AC 6A, 50 Hz for non-inductive load.
Fail Safe Mode Max. or Min. field selectable.
IndicationRed LED for alarm, Green LED for normal.
Response Time2 to 5 second
Switching Delay forAdjustable from 2 to 20 second for probe covered and un-covered condition.
Interconnection Cablea) Remote version 2-core independent screen.
b) Split version 3-core unscreened.
Standard Evaluation Unit
Overall Dim.180 x 180 x 85 mm
Weight2.5 Kg.

Model SelectionSLM.... Series Solids Level Switch:

Tuning ForkStainless steel 316
Mounting1½” screwed or 2" flanged.
Frequency85 Hz Std. (approximately)
Vessel Temp.-20º C to + 80º C.
Length150 to 3500 mm.
ExtensionPipe (Gl or SS).

View Complete Details

Yes, I am interested!

Vibrating Rod Level Switch
Interested in this product?
Get Best Quote
The Sapcon Vibrating Rod level switch "Vibrosonde" (SLP Series) is a vibration based switch for single point control. The instrument has an adjustable switching delay for covered and uncovered conditions. The electronics is available with integral as well as seperate with the rod and can be mounted in different ways such as wall/back panel mounting for remote version and directly on hopper wall incase of integral mounting. If the use is in hazardous area, you could choose the flame proof version. You also have the flexibility of choosing the insertion length.

The Vibrosonde (SLP... Series) is single cylindrical vibrating rod with no adjustment, no moving parts, no affected by moisture contents and electrical properties of process material.

 

Applications:

High and Low level limit control of free flowing powders and granules such as cement, flour, detergent, plastic granules.

Where is it used

Vibrosonde (SLP… series) level switches are successfully used in processing plants for High and Low level limit control of free flowing powders and granules such as cement, flour, detergent, plastic granules.

 

Principle:


A specially shaped tuning rod (vibrating rod) is kept in mechanical vibration at resonance frequency by piezo-electric elements. When the service material covers the rod probe, vibrations are damped which is sensed electronically and processed signal is used for switching. The output contacts of the relay can in turn be used for annunciation or control.

 

Technical Data:

Evaluation Unit

HousingCast aluminum, weather-proof stoving enamel painted, suitable for back panel/wall and integral with rod
Cable Entry3 No. / 2 No.
Mains110 or 230 V AC (-15% to +10% ) 50 Hz ; 240 V AC/DC; 90 to 260 V AC universal power supply.
Relay OutputOne/two set (s) of potential free change over contacts rated at 6A 230V AC, 50Hz for non-inductive load.
Time DelayAdjustable from 1 to 20 second for probe covered & uncovered condition.
IndicationRed LED for alarm and Green LED for normal condition.
Power Consumption5 VA approx.
Response Time1 second. approx.
Operating Temp.-20ºC to +60ºC
Fail-Safe ModeHigh or Low field selectable.

Probe

Tuning Rod
Stainless steel 316
Mounting1½" BSP screwed (flanged mounting on request). 2" ASA 10 mm thick Flange (Standard)
ExtensionStainless steel pipe.
Probe LengthMin. 250 mm, max. 3000 mm.
Operating-20º C to + 80º C.
TemperatureStandard models (amb temp. models up to 80º C are available.)
 DensityGreater than 0.7gm/cc.

View Complete Details

Yes, I am interested!

Pipe Fork Vibrating Fork Level Switch
Interested in this product?
Get Best Quote
Pipe Fork is a compact level switch suitable for all kinds of fluids and is used in tanks, containers and pipelines. Pipe fork is used in all types of fluids having viscosity up to 10,000 cP & densities greater than or equal to 0.7 gm. /cc.

Pipe Fork is a Vibrating Fork Type Level Limit Switch:

  • Power Supply

    10-35 VDC

  • Compact Instrument Size

    Less Inventory

  • Service Friendly plug in commotion
  • Output

    Open collector PNP
    LED Indication

  • Temperature Durability

    Standard Model up to 80°C

  • Operational safety, reliability
Principle

Pipe frok works on the principle of continuous vibration of the fork at its natural frequency by piezo electric element. Contact of material with the fork tips change the frequency causing the relay to change state, when the tines are free the fork builds up the vibration causing the relay the to revert to its previous state.

Mechanical Specification
HousingSS 316
MountingScrew 3/4" BSP/NPT
Fork Length40 mm
Cable EntryPG 11 Quick on
DimensionRefer Drawing/Customer Support
Electrical Specification
SwitchingLED Indication
IndicationRed: Alarm, Green: Normal
Input Supply10-35 VDC
OutputSwitching- Open collector PNP
Temperature0°C to 80°C
Fail SafeField Selectable
(Min: Failsafe Low, Max: Failsafe High)
Measuring Frequency1.4 KHZ
Application
  • Pharmaceutical
  • Chemicals
  • Pesticides
  • Edible Oil
  • Packaging
  • Food
  • Bulk Drugs
Why Sapcon:
  • Prompt and quick delivery
  • Customization and new technology
  • Complete range of instruments
  • Price Flexibility and interaction with management
  • Higher Safety and fewer down times

View Complete Details

Yes, I am interested!

Capacitance Level Switch
Interested in this product?
Get Best Quote

Capacitance Level Switch

Get Latest Price

The SLC... series level limit switch is used to accurately detect and measure fine/coarse solids and bulk solids. SLC... series can be used for level measurement of liquids that are non-sticky, corrosive or non-corrosive for switching conveyors off, indicating empty tank condition, preventing pumps for running dry.


The SLC... series capacitance level switch has been used by many of our clients successfully in the Cement, Plastic, Power, Food, Chemicals, Fertilizer, Sugar, Detergent and many other industries.

SLC... series consists of an evaluation unit, an electronic insert and a probe. The probe can be mounted form the top or side of the vessel. The probe system comprises of a sense electrode which is insulated from the metallic tank by means of a suitable insulator.

An accurate measurement of this change results in an indirect measurement of the material level in the tank. The electronic insert measures the change of capacitance accurately by using the Radio Frequency (R.F.) technique. This capacitance change is converted into a DC voltage variation, which is then transmitted to the evaluation unit via a 3-core unscreened cable for further processing.

 

Salient Features:


You can calibrate the level evaluation unit far away from the probe. This level switch uses an ordinary 3-core cable for interconnecting the electronic insert with the evaluation unit. A variety of built in multi-point evaluation units is available to reduce the number of discrete controllers; thereby reducing the overall cost of monitoring and measurement. The fail-safe high/low selection feature is available as a standard in SLC.... This systems is economical to install and you can even have it in circular enclosures for your specific requirements.

Technical Data 

Evaluation Unit

HousingCast Aluminum, Weather proof, back panel/wall mounting
Cable Entries3 Nos. / 2 Nos.
Max. Amb. Temp.- 20º C to + 60º C.
Power Consumption5 VA approx.
Mains Voltage230 V or 110 V AC (-15% to +10%), 50 Hz; 24 V AC/DC; 90 to 260 V AC universal power supply. (to be specified while ordering).
Relay OutputOne/two sets of potential free change over contacts rated at 230V AC 6A, 50 Hz for non-inductive loads per set point.
Fail-Safe ModeMax. or Min. Field selectable.
IndicationRed LED for alarm, Green LED for normal, Yellow LED for system fault.
Response Time0.2 Second
Switching DelayAdjustable from 0.5 to 20 Second. for probe covered or uncovered condition.
Connection to Electronic Insert3 - core unscreened cable.
Initial Capacitance0 to 290 pf. in 3 overlapping ranges.
(For single point switching)
0 to 1200 pf. in 3 overlapping ranges.
(For pump control & multi point switching)
Switching Hysteresis0.5 pF. typical. (For independent switching) & Continuously adjustable over the entire range. (For pump control switching)

 

Probe:

A wide variety of probes with different mounting connections is available to suit various process applications.

View Complete Details

Yes, I am interested!

Capacitance Level Sensor
Interested in this product?
Get Best Quote

Capacitance Level Sensor

Get Latest Price

We call this series the “Intelligent Capacitance Level switch series”. And we do so because MP-SLC has a microprocessor that checks the complete system (including itself) before validating a signal. You will see a flashing green LED that serves as heartbeat to indicate a healthy system. In the case of a system fault ,which may result due to incorrect wiring, open or short sensor connection, inadequate probe insulation improper grounding or electronic insert failure, the heartbeat stops fault LED glows, display indicates “E---“ and the relay contacts revert to their fail-safe condition.

The MP-SLC level switch is a highly reliable liquid and solids level indicator. A two wire Pulse Frequency Modulation (PFM) is used for interference-free signal transmission between probe and evaluation unit. Complete system is checked before each measurement and the system has a provision for auto-compensation for temperature drift in the vicinity of a pre-amplifier.

The MP-SLC... series exhibits a high degree programmability. Important functions such as operating mode (independent/pump control), delayed switching for probe covered/uncovered conditions, fail safe high/low, switching sensitivity, switching delay and set point calibration are programmable via a keypad.

Technical Data

Evaluation Unit

HousingCast aluminium, Weather-proof Stoving enamel painted, suitable for back panel/wall mounting.
Cable Entries3 Nos. of ½” BSP
Mains Voltage110 V or 230 V AC (-10 to +10%) 50 Hz (as specified in order).
Power Consumption5 VA approx.
Initial Capacitance Adjustment30 pF to 280 pF in two selectable ranges.
Indication2½ digit, 0.5 inch Red LED display; 2 inch display is also available in separate housing
Operating Temperature-20o C to +60o C
Utilizable Capacitance Variation10 pF to 4500 pF in three selectable ranges.
Accuracy± 2% of the F.S.D.
Outputs0 -100% digital display 0/4 -20 mA into RL max. 400 Ohms and 0 -5 V
DC for RL >25 KW for remote indicators and recorders.
Dimensions185 mm x 185 mm x 85 mm
Weight2.3 Kg (approx.)

 

Electronic Insert - LCD 312

HousingPlastic with electronics potted in epoxy resin.
Supply20 V DC max. 10 mA. derived from Evaluation Unit.
Measuring Frequency33 K Hz (approx.)
Operating Temperature-20o C to + 60o C.

 

Probe

HousingCast Aluminium , SS, FRP-coated, HDPE.
MountingFlanged or Screwed as per requirement.
Length
150 mm to 3000 mm in Rod, Greater than 3000 mm in Rope.
InsulationPart or full PVC, PTFE, Ceramic (Part only) depending on service temperature of 80o C, 200o C or 400o C respectively.

 

Reference probe is required, when the tank is non-metallic. Grounding tube is required, when the liquid is turbulent or tank shape is curved.

View Complete Details

Yes, I am interested!

Capacitance Continuous Level Indicator
Interested in this product?
Get Best Quote

Dependability, strength, durability, ruggedness are the keywords when it comes to the use of level instruments for continuous monitoring in difficult environment conditions. The ILC... series stands up to the requirements of a tough continuous level detector and offers the following benefits:

  • Level is displayed on a built-in Digital Panel Meter having 0.5 inch high digits for better visibility.
  • Standard output signal of 0-5 V DC and 4-20 mA DC proportional to 0-100% level change available for remote indicators and recorders.
  • "In Situ" range selection and calibration possible from evaluation unit. Probe head accessibility not required.
  • Measuring system has no moving parts so does not suffer any mechanical wear and tear and hence is maintenance free.
  • Economical to install, since ordinary 3-core cable is used for interconnection.
  • Flame-proof probe suitable for hazardous areas as per IS-2148 for group IIA and IIB is available.
As far as the service material is concerned, the ILC indicator can be used with conductive or non-conductive liquids, powdered or grained materials of homogeneous composition having stable dielectric constant. Our clients in the Oil, Food, Water treatment, Diesel, Chemicals etc. industries have used the ILC level indicator to their satisfaction.

Technical Data
 

Evaluation Unit

Housing Cast Aluminium, Weather proof, back panel/wall mounting
Cable Entry 3 Nos. / 2 Nos.
Max. Amb. Temp. -20o C to + 60o C.
Power Consumption 5 VA approx.
Mains Voltage 230 V or 110 V AC (-15% to +10%), 50 Hz; 24 V AC/DC;
90 to 260 V AC universal power supply. (to be specified while ordering).
Relay Output One/two set (s) of potential free c/o contacts rated at 230V AC 6A, 50 Hz for non-inductive load per set point.
Fail-Safe Mode Max. or Min. Field selectable.
Indication Red LED for alarm, Green LED for normal, Yellow LED for system fault.
Response Time 0.2 Second
Switching Delay for Adjustable from 0.5 to 20 Second. for probe covered or uncovered condition.
Connection to Electronic Insert 3 - core unscreened cable.
Initial Capacitance 0 to 290 pf. in 3 overlapping ranges. (For single point switching)
0 to 1200 pf. in 3 overlapping ranges.(For pump control & multi point switching)
Switching Hysteresis0.5 pF. typical. (For independent switching) & Continuously adjustable over the entire range. (For pump control switching)

 

Electronic Insert - LDC 311

Housing Plastic, potted in epoxy resin.
Frequency 500 kHz. (approximately).
Ambient Temp. -20o C to 80o C.
Supply Voltage 15 V derived from evaluation unit.
Output Signal 3 to 12 V DC.

 

Probe

A wide variety of probes with different mounting connections is available to suit various process applications. We offer specially designed ceramic insulated rod/rope probes suitable for operating temperatures max up to 600o C.

View Complete Details

Yes, I am interested!

Translite Fuel Level Sensor
Interested in this product?
Get Best Quote
Sapcon Instruments offers the TRANSlite family of fuel level sensor instruments which use the capacitance technology for accurate fuel and oil level measurement in process plants. TheTRANSlite indicators have no moving parts and can be ideally used in extreme plant conditions of high temperature and pressure.

 

The TRANSlite level sensor range supports a power supply within DC automation is available from 11 to 55 VDC, addressing the need for 12V, 24V and 48V industrial supply options.4-20mA Current Loop is galvanically isolated (4 Wire) and PLC, SCADA compatible.4-20mA Current Loop can supply up to 1000 Ohm series load with 24VDC supply. This means 4-20mA signal can be carried to longer distance. The ease of calibration ensures user friendliness: “Just let it know the fuellevel for 4mA and 20mA, rest it will take care of.” Following are the options for you to choose from:

 

TRANSlite Fuel Level Sensor - It is composed of the specially developed Capacitance change gaging circuit. TRANSlite uses a fast RISC based processor which is the best in its class for evaluating fuel level using capacitance. The capacitance is formed by the sense rod and the metallic container wall. For non-metallic and/or non-uniform shaped containers, a metallic stilling well is provided. The amount of capacitance is proportional to the level of material between the sense rod and metallic wall of stilling container.

 

TRANS~lite Fuel Level Sensor - The best affordable liquid fuel level measuring solution for high temperature conditions. Its key feature is the ease of calibration which is not commonly available in this range of fuel level transmitters. TRANS~lite allows electronic-less measurement of level up-to 5 meters distance between the probe and the electronics.

 

TRANS2lite Fuel Level Sensor is a microcontroller based 2 wire capacitance fuel level sensor. TRANS2lite has temperature compensated electronics that provide a stable output. This fuel level sensor allows calibration in steps of 10% from 0 to 100% eliminating the need for rigorous emptying filling calibration.

 

Best in the Industry

 
Fast delivery on request, cost effectiveness and low power consumption make this level sensor a cut above the rest. All in all, TRANSlite is a complete “value for your money” level measurement device and if your system has a SCADA or PLC interface, TRANSlite is your best buy.

 

FUEL Level Sensor Customization

TRANSlite instruments can be custom designed to your specification requirements. The sensors have no moving parts and are extremely accurate. They can be designed to fit within the tightest of space envelopes and withstand the most acute work environments.

View Complete Details

Yes, I am interested!

Level Transmitter
Interested in this product?
Get Best Quote

Level Transmitter

Get Latest Price

The MPILC series is a microprocessor based level transmitter designed to withstand the acute environment conditions and give you accurate detection of service material level in your process unit. This continuous level transmitter can be used for any solid or liquid that has a homogenous composition and a stable dielectric value.

The MPILC system has a microprocessor which checks the complete system and itself before validating the signal. A flashing green LED serves as heartbeat to indicate a healthy system. In the event of occurrence of a system fault such as incorrect wiring, open or short sensor connection, failure of probe insulation, improper grounding or electronic insert failure, the heartbeat stops, fault LED glows, display indicates “Err--“ and the relay contacts revert to their fail-safe condition.

The MPILC continuous level transmitter system uses a two-wire Pulse Frequency Modulation (PFM) for interference-free signal transmission between probe and evaluation unit.

Technical Data

Evaluation Unit

HousingCast Aluminium Whether-proof Stoving Enamel painted, suitable for back,panel/wall mounting.
Cable Entries3 Nos. ½” BSP/NPT
Operating Temperature–20 to +60º C
Mains90 -260 V AC / 50 - 60 Hz.
24V DC
Power Consumption3.5 VA approx.
Measuring range10 pF to 4500 pF
Offset30 pF to 280pF
IndicationPercentage display from – 50% to +150% on multipurpose 5 Digit 0.5” LED display (2” display also available in separate housing)
Accuracy+/- 2% of the measuring range
Programmingvia 5 push button keys
Analog Output4 -20 mA galvanicaly isolated output with two wire capability
Load ResistanceRL (Max) = 1 KΩ
Galvanic Isolated18 to 22 V (Safe RL (Max) = 800 Ω for on board supply
Relay output3 potential free relays, (rated at 6A,230V,AC, 50Hz for non-inductive load), for three point level switching Independent/pump control switching. Time delay programmable up to 99 sec.
DimensionsOverall 185X185X85mm

 

PRE-AMPLIFIER (Electronic Insert) LDC - 117:

HousingPlastic with electronics potted epoxy resin, mounted in probe head.
Potting-20º C to 80º C. 12 V at 17 mA max. derived from evaluation unit only.
Operating Temperature-20º C to +80º C
Supply18V DC at 10mA (approx) derived from evaluation unit
Measuring Frequency50 -250 KHz

 

Level Transmitter - Probe

Probe HeadCast Al. weather-proof.
MountingFlange or Screwed as per requirement
Length :150 mm to 3000 mm in Rod Probe, greater than 3000 mm in Rope
InsulationPart or Full PVC, PTFE, Ceramic (Part Only) depending on service temperature of 80º C, 200º C or 400º C respectively.

Note :

- Reference probe is required, when the tank is nonmetallic

- Grounding tube is required, when the liquid is turbulent or tank shape is curved

- Two core screened cable required for interconnection (Up to 1Km, user's scope)

View Complete Details

Yes, I am interested!

Admittance type Level Switch
Interested in this product?
Get Best Quote

Intelligent and Self Checking

SAPCON 'ADMiRE' is a high-end RISC core microcontroller based level sensing limit switch, based on admittance principle. With it's specially developed algorithm it tracks the material trend continuously. In associaion with its 3-element probe utilizing the driven shield principle, it compensates for material build-up and thus It is immune to material build-up to a much larger extent. Simple push button type - hassle-free - calibration renders the unit installation and comissioning much easier. Failsafe selection and Cover/Uncover delays are settable any time while the device is in use. Available output options are PNP-NO and SPDT change-over relay. Power options are 10 to 55 VDC for PNP/NO and 85 to 265 VAC 50/60Hz for SPDT changeover type. SPDT with AC operation is also available in Flameproof enclosure.

 

Application

Sapcon 'ADMiRE' is ideal for use in constricted places due to its compact size and short insertion length. It can be used for detecting level in vessels containing granular solids , powders ; liquids and slurries. It can be used in dusty plant environment.

 

System Description

The sense and ground element of the probe form the electrodes of a capacitor with the service material as the dielectric. When the probe is not covered, the dielectric is that of air, whereas when covered, it is that of the service material. A change in the physical level of the material causes a change in the dielectric media between the two electrodes, thus causing a change in the measured capacitance. 

 

Technical Data

Evaluation Unit

Power supply10 -55V DC (optional 85 to 265 VAC 50/60Hz)
Outputs PNP-NO (optional SPDT potential free relay output)
Max. Load current Non-Latching 120mA for PNP-NO
Indication B-Color LED Red: Alarm, Green : Normal
Fail-safe mode Minimum or Maximum (Field Selectable)
Switching delay Covered / Uncovered configurable from 1 to 20 seconds
Housing Cast aluminium weather-proof (Optional Flame-proof)
Cable entry 1 no. ½” BSP
Sensor mounting <1” BSP / NPT
Probe Insertion length minimum 100 mm
Weight ~1.300 Kg

View Complete Details

Yes, I am interested!

COATEn-DURE Admittance Level Limit Switch
Interested in this product?
Get Best Quote
Coat EnDure is a compact level switch suitable for sticky solids and pastes. The device has been designed specially for packaging plans, where materials have a tendency to stick on the probe. Coat EnDure is an improvement over traditional pricing of admittance. The ring type probe has alternating active and inactive regions, which help the controller to calculate the extant of coating on the probe. In effect the device is able to identify the differential coating between sense and the shield by measuring their individual capacitances. As the coating immunity is controlled by the onboard micro-controller, the extent of coating immunity can be set easily.

Mechanical Specification
  • Housing Pressure Die Cast
  • Mounting Screw 1” BSP/NPT 9 (minimum)
  • Flange Available as per Specification
  • Cable Entry 2X1/2” BSP/NPT or PG 13.5
  • Dimension Refer Drawing /Customer Support
Electrical Specification
  • Switching Bi-color LED
  • Indication Red: Alarm, Green: Normal
  • Input supply 11-55 VCD/90-265 VAC
  • Current 50mA max. At 18 VCD with load
  • Consumption
  • Output Analog- 8/16mA
  • Switching- Relay /PNP
  • Relay Type- SPDT/DPDT
  • Temperature 0°C to 70°C
  • Fail Safe Field Selectable
  • (Min: Failsafe Low, Max: Failsafe High)
  • Delay Setting Covered and Uncovered 2-20 sec.

Application

  • Solids
  • Powder
  • Pastes
  • Packaging industry
NOTE- For non Conductive material
Why Sapcon
  • Prompt and quick delivery
  • Customization and new technology
  • Complete range of instruments
  • Price flexibility and interaction with management

View Complete Details

Yes, I am interested!

Admittance Level Limit Switch SLA Series
Interested in this product?
Get Best Quote
SLA series is an admittance based level switch series with RF signal transmission between probe and evaluation unit via a co-axial cable with drain wire having driven shield arrangement to eliminate cable capacitance and drift due to change of cable capacitance with temperature. You can install the evaluation unit even far from the probe. The calibration controls are available in the evaluation unit.

The SLA Series switch can be efficiently used to reduce the inventory as the same evaluation unit can be field configured either for High or Low level fail-safe detection. The SLA series Ignores build-up of service material between probe, the vessel walls and the coating. SLA uses 3-Electrode technique with driven shield arrangement to achieve high degree of immunity.

The measuring system for this level detection tool consists of an evaluation unit and an immune-coat probe that could be mounted either from the top or side of the vessel. The probe comprises sense and shield electrodes electrically isolated from the metallic tank by means of suitable insulators. The sense electrode of the switch and the vessel wall serve as the two electrodes of a capacitor with the service material as the dielectric. A change in material level causes a change in dielectric, which in turn causes a change in admittance of this tank capacitor.

Technical Data  

Electronic Insert - ICA 3000

HousingPlastic , potted in epoxy resin.
Measuring Frequency~ 500 KHz.
Ambient Temp.-20º C to + 80º C.
Supply Voltage15 V derived from evaluation unit.
Output Signal3 to 12 V DC.

Evaluation Unit

HousingCast Aluminum, Weather proof, back panel/wall mounting
Cable Entries3 Nos.
Max. Amb. Temp.- 20º C to + 60º C.
Power Consumption5 VA approx.
Mains Voltage230 V or 110 V AC (-15% to +10%), 50 Hz; 24 V AC/DC 90 to 260 V AC universal power supply (to be specified while ordering).
Relay OutputOne/two sets of potential free change over contacts rated at 230V AC 6A, 50 Hz for non-inductive loads per set point.
Fail-Safe ModeMax. or Min. Field selectable. Indication Red LED for alarm, Green LED for normal, Yellow LED for system fault.
Indication (switching)Red LED for alarm, Green LED for normal.
Response Time0.2 Second
Switching Delay
322/622/
822/922
Adjustable from 0.5 to 20 Second. for probe covered or uncovered.
Connection to Probe Insert3 - core unscreened cable.
Initial Capacitance
SLA 122/222
322/622/822
SLA 522/722/922

0 to 290 pf. in 3 overlapping ranges.

0 to 1200 pf. in 3 overlapping ranges.
Switching /Hysteresis
SLA 122/222/
322/622/822
SLA 522/722/922

0.5 pf. typical.

Continuously adjustable over the entire range.

View Complete Details

Yes, I am interested!

Float Type Level Limit Switch
Interested in this product?
Get Best Quote

The processed signal is used to energize or de-energize a relay whose output contacts are available for annunciation or control.

An accurate measurement of this change affords an indirect measure of the level of material in the tank. The evaluation unit measures the change of admittance accurately by using radio frequency (R.F.) technique coupled with coat immunizing circuitry.

Many process industries viz. cement, power, steel, food, chemicals, fertilizer, sugar, detergent etc. have been using the SLA series of level switch for reliably measuring and self checking the level of service material which may include fine or coarse solids of low dielectric constant that have a tendency to stick.

A wide variety of probes with different mounting connections is available to suit various applications. We offer specially designed ceramic insulated rod / rope probe suitable for operating temperatures up to 600° C max.

Note : Bar display is recommended for longer distance between probe and evaluation unit and for materials having tendency to absorb moisture.

 

Technical Data  

Electronic Insert - ICA 3000

HousingPlastic , potted in epoxy resin.
Measuring Frequency~ 500 KHz.
Ambient Temp.-20º C to + 80º C.
Supply Voltage15 V derived from evaluation unit.
Output Signal3 to 12 V DC.

Evaluation Unit

HousingCast Aluminum, Weather proof, back panel/wall mounting
Cable Entries3 Nos.
Max. Amb. Temp.- 20º C to + 60º C.
Power Consumption5 VA approx.
Mains Voltage230 V or 110 V AC (-15% to +10%), 50 Hz; 24 V AC/DC 90 to 260 V AC universal power supply (to be specified while ordering).
Relay OutputOne/two sets of potential free change over contacts rated at 230V AC 6A, 50 Hz for non-inductive loads per set point.
Fail-Safe ModeMax. or Min. Field selectable. Indication Red LED for alarm, Green LED for normal, Yellow LED for system fault.
Indication (switching)Red LED for alarm, Green LED for normal.
Response Time0.2 Second
Switching Delay
322/622/
822/922
Adjustable from 0.5 to 20 Second. for probe covered or uncovered.
Connection to Probe Insert3 - core unscreened cable.
Initial Capacitance
SLA 122/222
322/622/822
SLA 522/722/922

0 to 290 pf. in 3 overlapping ranges.

0 to 1200 pf. in 3 overlapping ranges.
Switching /Hysteresis
SLA 122/222/
322/622/822
SLA 522/722/922

0.5 pf. typical.

Continuously adjustable over the entire range.

View Complete Details

Yes, I am interested!

RF Admittance Level Switch
Interested in this product?
Get Best Quote
SLA...M series is an admittance based level switch with RF signal transmission between probe and evaluation unit via a co-axial cable with drain wire having driven shield arrangement to eliminate cable capacitance and drift due to change of cable capacitance with temperature. You can install the evaluation unit even far from the probe. The calibration controls are available in the evaluation unit. A special ten LED dot display/bar display simplifies calibration and indicates material trend in vicinity of the point level.

The SLA...M Seriesswitch can be efficiently used to reduce the inventory as the same evaluation unit can be field configured either for High or Low level fail-safe detection. The SLA...M series Ignores build-up of service material between probe, the vessel walls and the coating. The level limit switch uses 3-Electrode technique with driven shield arrangement to achieve high degree of immunity.

The measuring system for this level limit detection tool consists of an evaluation unit and an immune-coat probe that could be mounted either from the top or side of the vessel. The probe comprises sense and shield electrodes electrically isolated from the metallic tank by means of suitable insulators. The sense electrode of the switch and the vessel wall serve as the two electrodes of a capacitor with the service material as the dielectric. A change in material level causes a change in dielectric, which in turn causes a change in admittance of this tank capacitor.

The processed signal is used to energize or de-energize a relay whose output contacts are available for annunciation or control.

 

Technical Data  

Evaluation Unit

HousingCast Aluminum, weather proof, back panel / wall mounting.
Cable Entries3 No. / 2 No.
Max. Amb. Temp.-20º C to + 60º C.
Power Consumption5 VA approx.
Mains Voltage230 V or 110 V AC (-15% to +10%), 50 Hz; 24 V AC/DC 90 to 260 V AC universal power supply (to be specified while ordering).
Relay OutputOne/two set (s) of potential free change over contacts rated at 230V AC 6A, 50 Hz for non-inductive loads.
Fail-Safe ModeMax. or Min. field selectable.
Indication (switching)Red LED for alarm, Green LED for normal.
Indication (sensitivity)10 step LED dot / bar display
Response Time0.2 second typical.
Switching DelayAdjustable from 0.5 to 20 second for probe covered or uncovered.
Connection to ProbeVia co-axial screened cable with drain wire.
Switching Hysteresis0.2 pF. typical.

 

Probe

A wide variety of probes with different mounting connections is available to suit various applications. We offer specially designed ceramic insulated rod / rope probe suitable for operating temperatures up to 6000 C max.

View Complete Details

Yes, I am interested!

Intelligent Admittance Level Limit Switch
Interested in this product?
Get Best Quote

Highly Reliable

Two-wire Pulse Frequency Modulation (PFM) is used for interference-free signal transmission between probe and evaluation unit. Complete system is checked before each measurement. Auto compensation for temperature drift in the vicinity of pre-amplifier.

Ignores Build-Up

Special three-element probe and immunocoat circuitry enables the system to ignore coating on the probe, build-up from wall and suspended dust particles, but reacts only to a true level.

 

Automatic Switch Point Optimisation

Application

Level control of solids, liquids and slurries of conductive/Non-conductive, sticky/non-sticky material requiring extreme safety and high degree of reliability in industries such as cement, food, chemical and petrochemical, effluent treatment, cosmetics.

Technical Data

Evaluation Unit

Housing Cast aluminium, Weather-proof, Stoving enamel painted, suitable for back panel / wall mounting.
Cable Entry 3 Nos. of ½” BSP /NPT /NG20
Ambient Temperature 20º C to + 60º C.
Mains 110/230 V AC (-10 to +10%) 50 Hz (as specified in order).
Power Consumption 5 VA approx.
Indication (Switching)Red LED for each level alarm, red LED for fault alarm, flashing green LED as heart-beat for healthy condition.
Indication (calibration)LCD, one digit for mode field and two digits for data field.
Response Time 0.2 Second. Typical.
Swtiching Delay Programmable upto 99 Second. For probe covered/ uncovered condition for each set point.
Connection to 2-core ordinary cable,
Electronic Insert having max. resistance of 25 W per core.
Initial capacitance20 to 1200 pF.
Switching Hysterisis Approx. 0.5 pF at initial
(single point operation)Capacitance of 30 pF.
Switching Hysterisis Programmable over
(Two point pump control) entire setting range.
Build-up CompensationApprox. 0 - 99 steps
Relay Output One set of potential free change over contacts per channel rated at 6A 230 V AC, 50Hz for non- inductive load.
Fail-Safe ModeHigh or Low field programmable for both channels.
Weight 2.5 Kgs approx.
Overall dimensions180 x 180 x 85 cm

 

Electronic Insert

Housing Plastic with electronics potted in epoxy resin.
Measuring Frequency 20º C to 80º C. 12 V at 17 mA max. derived from evaluation unit only.

 

Probes

Housing Cast Aluminium, SS, FRP-coated, HDPE.
Mounting Flanged or Screwed as per requirement.
Electrode Element Special 3-element Probe Sense, Shield and Ground.
Length 150mm to 3000 mm in Rod, Greater than 3000 mm in Rope.
Insulation Part or full PVC, PTFE, Ceramic (Part only) depending on service temperature of 80º C, 200º C or 400º C respectively.

 

Reference probe is required, when the tank is non-metallic. Grounding tube is required, when the liquid is turbulent or tank shape is curved.

View Complete Details

Yes, I am interested!

SLW Water Level Sensor
Interested in this product?
Get Best Quote

SLW Water Level Sensor

Get Latest Price

The SLW series is capable of liquid level monitoring and measurement in in tanks, reservoirs, and in harsh environment conditions. The sensor is economical to install as no special cable is required for signal transmission. This water level sensor is conducive for liquids that have a conductivity of equal to or more than 25m Siemens. The level probe and the evaluation unit can be connected using a long cable. The AC is provided on the probe for preventing electrode deterioration.

You can choose from among a variety of level control and installation systems such as

  • Two point sensors for independent switching and automatic control of pump.
  • Four point switching with two pump control logic.
  • Three point switching: two for pump control logic and one independent point with or without a settable delay (for probe covered or uncovered).
  • A variety of probes is available for your specific process.

SLW Water Level Sensor Applications

The SLW... series water level switches work to maintain a constant water level avoiding material wastage in your process plant. Common applications include switching pumps on and off to avoid overflow, dry running and indicating water level in an empty tank to avoid wear and tear and production stoppage. Customers in the Food, Power, Chemicals, Sugar, Detergent, Steel, Minerals and Textile industry have used the SLW..

 

SLW Water Level Sensor - Operating Principle:

A low AC voltage is applied between the probe electrode and the tank wall (or reference electrode in case of insulated tank). When the water/liquid comes in contact with the electrode tip, a conductive path is established between the sense electrode and the tank wall/reference electrode.

Water Level Sensor Technical Data  

SLW Water Level Sensor Evaluation Unit

Housing Cast aluminium, Weather-proof Stoving enamel painted suitable for back panel/wall mounting.
Cable Entries 3 Nos. of 1/2 “ BSP
Mains 110 or 230 V AC (-15 to + 10%) 50 Hz (as specified in order).
Relay Output One set of potential free change over contacts rated at 6A 230 V AC, 50Hz for non-inductive load.
Power Consumption5 VA approx.
Fail-Safe Mode High or Low field selectable.
Response Time 0.5 second
Switching Delay 0.5 to 20 seconds for probe covered and uncovered condition
Maximum Sensitivity 25 Micro Siemens
Operating mode (A) Single point switching.

(B) Two-point switching with pump control logic.
Indication Red LED for Alarm, Green LED for Normal.
Mounting 1½” BSP Screwed or Flanged mounting.
Operating Temp. -20º C to + 60º C.
Weight ~2 Kg.

 

Water Level Sensor - Level Probe

Voltage 12 V AC (across probe & tank wall/ grounding electrode)
Current <4 mA (between probe & tank wall/grounding electrode through liquid)
Operating Temp. Up to 80º C (Standard model)
Up to 200º C (Optional)

View Complete Details

Yes, I am interested!

Loh Loss of Head Indicator
Interested in this product?
Get Best Quote
Sapcon LOH (loss of head indicator) is a perfect solution of measuring differential level in open channels and is widely used in water treatment plants and filter stations. The LOH series instruments are RISC Processor based capacitance type Continuous Level Indicators with built in three point switching.

Salient Features:


- Latest RISC core microcontroller technology.

- Measured level is displayed continuously from -50% to 150%.

- Multipurpose 5 digit seven segment LED display for best resolution and better viewing from distance.

- Two wire pulse coded digital communication from sensor to evaluation unit.

- 4-20mA loop can handle 700 Ohm loop resistance with internal isolated supply.

- Three independent potential free relays providing flexibility of selecting three independent switch points.

 

Principle of Operation:


The loop resistance can be 1K Ohm for External DC Supply of 24 Volts. In an application, the measuring electrode (sense probe) and the container wall (ground or reference probe) form a capacitor. The amount of capacitance of this capacitor is governed by the dielectric constant of the material between the two electrodes (sense probe & metallic container wall or reference probe or ground).

Evaluation Unit

Housing Cast Aluminum, Weather Proof, Stoving Enamel Painted. Suitable for back panel / wall mounting.
Cable Entries 3 Nos. of / BSP/NPT
Operating Ambient Temperature -20°C to +60°C
Power supply Universal Mains 90 to 265 VAC, 50/60Hz and 24VDC (@ 3 Watt)
Sensor to Evaluation Unit Cable 2-Core; resistance per core not to exceed 30 Ohms. Use of shielded twisted pair cables is recommended for long runs of cable. Cable lengths of 1000 meters are thus supported with grounded cable shields.
Utilizable span 10 to 4500 PF
Zero% Range 30pf to 250pf
100% Range 10pf to 4500pf (Difference from Zero %)
Outputs Current 4 to 20mA. 3 Potential Free relays with One set of Potential Free Change Over Contact per Relay.
Contact Ratings 6 Amp @ 230VAC 50/60 Hz for non-inductive loads.
Indication Continuous -50% to 150% digitally on 1 ” Seven Segment Display
Switching 5 mm Red LEDs’ for Alarm Indication.
Switching Hysterisis 1% in Single Point Switching, 1 to 98% selectable in Pump Control.

Field Selectable through interactive relay configuration menu.
2.3 Kg Approx.N
- LDC117, LCDM 111
potted with epoxy resin.
16VDC @ 5mA derived from Sensor Communication Interface of Evaluation Unit.
250Khz to 20Khz. Reverse Frequency Measurement.
20 C to +60 C
10 counts per pF
Digitally Encoded Current (5mA-8mA) Pulse.

 

Probe:

Probe Head : Cast Aluminum weather proof Mounting Flanged or screwed as per requirement standard Length 750 to 1500 mm Rigid, with grounding tube as reference and still-well. Insulation Full PTFE

NB: 


1) Reference probe required for non metallic tanks / weirs.

2) Grounding tube required for turbulent liquids.

3) 2-core shielded cable required for electronic insert to Evaluation unit interconnection up to 1 km. (users’ scope).

View Complete Details

Yes, I am interested!

ROF Flow Indicator
Interested in this product?
Get Best Quote

ROF Flow Indicator

Get Latest Price

The MPROF Rate of Flow indicator is a capacitance based solution for reliable detection of rate of flow of liquids in an open channel. The level change is measured using the capacitance principle and converted to rate of flow utilizing the appropriate formula. The MPROF system has an interactive user interface offering you to choose from any of the below mentioned hydraulic devices:

Cipoletti

Fully Contracted Rectangular Standard Suppressed Rectangular OR 90° Notch Triangular Weir or Custom K & N Factor Entry Once you choose the hydraulic device of your choice, calculations of the flow rate are automatically done by the built-in microcontroller and the value displayed in percentage (%), cusecs or custom units as per choice. The system can display the level in % or in millimeters, if so desired

Salient Features:

Microprocessor based system for higher degree reliability and stable operation in noisy environment due to intelligent digital communication between the electronic insert and the evaluation unit.

- All parameters programmable via Five keys and Five multipurpose LED displays. No potentiometer settings required.
- Galvanically isolated 4 to 20ma output proportional to either level or flow.
- Three relays for programming three levels / flow independently or as per pump- control logic.
 

Principle Of Operation:

When the liquid flows through a Hydraulic measuring device (Weir), the level of the liquid is directly proportional to the rate of flow. By knowing the constants of the Weir.

Technical Data:

Evaluation Unit

Housing Cast aluminum, weather proof, stoving enamel painted, suitable for back panel/wall mounting
Cable Entry 3 Nos. ½” BSP / NPT
Tolerable ambient temp -20°C to +60°C
Power supply 90 to 260V AC 50Hz, and 24V DC
Power consumption 3.5VA (approx.)
Utilizable span 10 to 4500 PF
Zero setting range 30 to 280 PF
Indication range 50% to 150% on multipurpose 5 digit 0.5” LED
Accuracy +/- 1% FSD
Switching Hysterisis 1% in single point switching and 1 to 98% selectable in 2 point Pump control logic.
Programming interface5 Push Button Keys
Analog output 4 to 20 ma galvanically isolated into Max 1K Ohm load for 24V DC user supply. Max 800 Ohm for internal isolated supply of 18 to 22 V DC.
Output 3 sets of potential free change over contacts rated at 6A, 230V, AC, 50Hz for non-inductive loads
Switching delay Programmable up to 99 sec.
Fail-safe High/Low field programmable
Dimensions 180 x 180 x 85 mm

 

PRE-AMPLIFIER (electronic insert) LDC117

Housing Plastic with electronics potted, mounted in Probe Head
Operating Temp. - 20 to +80 deg. C
Supply 18 V DC at 8ma (approx.) derived from evaluation unit
Measuring Frequency 250Hz to 20 KHz reverse frequency measurement

 

View Complete Details

Yes, I am interested!
4.0/5★★★★★★★★★★

Reviewed by 1 Users

5 star0

4 star1

3 star0

2 star0

1 star0

Most Relevant Reviews

R

Rajesh Kumar | Skytech Electricals| Gurgaon, Haryana

★★★★★ ★★★★★

10-September-20

Tell us what you need, and we’ll help you get quotes
Tell us what you
need
Receive seller
details
Seal the deal
Pay with IndiaMART
Tell us what you need, and we’ll help you get quotes
I agree to the terms and privacy policy