Inspection Service
We are offering Inspection Service to our clients.
Interested in this product?
Get Best Quote
Fire Resistance Inspection Service
₹ 20,000/ ServiceGet Latest Price
Minimum Order Quantity: 1 Service
Inspection Service For | Equipment |
Inspection Interval | Yearly |
Inspection Method | Specific Instrumentation |
Usage/Application | Industrial |
Industry Type | Manufacturing |
Service Type | Fire Safety Audit Service |
Mode Of Report | Hard Copy |
Service Location | All Over the World |
Service Mode | Offline |
Service Duration | 15 - 30 days |
Eucert ICSPL provides fire resistance inspection services as per the following parameters:
- Standard ISO 834-8 specifies the procedures to be followed for determining the fire resistance of non-loadbearing vertical separating elements when exposed to heating on one face.
- Standard ISO 6944-2 establishes a method of test in which kitchen extract ducts are required to provide fire resistance. The requirements are intended to limit the spread of fire from the duct when a fire occurs within the duct and assesses the structural integrity of the duct when a fire occurs in the area surrounding the duct.
- Standard ISO 6944-1 specifies a method for determining the fire resistance of vertical and horizontal ventilation ducts under standardized fire conditions. The test examines the behavior of ducts exposed to fire from the outside (duct A) and fire inside the duct (duct B). It is intended that ISO 6944-1:2008 be used in conjunction with ISO 834-1
- Standard ISO 3008 used in conjunction with ISO 834-1, specifies a method for determining the fire resistance of door and shutter assemblies designed primarily for installation within openings incorporated in vertical separating elements, such as hinged and pivoted doors, horizontally sliding and vertically sliding doors, including articulated sliding doors and sectional doors, steel single-skin folding shutters (un-insulated), other sliding, folding doors, tilting doors, rolling shutter doors and removable panels in walls.
- This method can also be used to determine the fire resistance of non-loadbearing horizontal doors by analogy. However, these are not specifically addressed here and the field of direct application is not valid for horizontally oriented doors.
- Eucert Assessors/Inspectors/Auditors witness the Fire resistance in the above mentioned areas and produce an inspection report against the specified standards. The witness can take place in a lab facility or the manufacturer’s premises.
Additional Information:
- Item Code: 99
- Production Capacity: Any
- Delivery Time: Vary
View Complete Details
Yes, I am interested!
Interested in this product?
Get Best Quote
Type Of Security | Unarmed |
Requirement Type | Corporate |
Service Duration | 15 - 30 days |
Service Location | All Over the World |
Service Mode | Offline |
Electrical Installation Safety Inspection:
- Standard IEC 60364 specifies assessment of general characteristics of Low voltage installation in buildings for Protection against electric shock, Protection against thermal effects, Protection against overcurrent, Protection against voltage disturbances and electromagnetic disturbances.
- Standard IEC 60364-5 specifies best practices for Selection and erection of wiring, Isolation, switching and control,Earthing arrangements and protective conductors and Safety services.
- Standard IEC 60364-7 specifies requirements for special installations or locations such as rooms containing bath or shower, swimming pool, sauna heaters, restricted movement, medical installation, PV installation, communal facilities and work places.
Additional Information:
- Item Code: 045
- Production Capacity: Any
- Delivery Time: Vary
View Complete Details
Yes, I am interested!