- 50 kVA FG Wilson Diesel Generator, 3 Phase
- 62.5 kVA FG Wilson Diesel Generator, 3 Phase
- 82.5 kVA FG Wilson Diesel Generator, 3 Phase
- 100 kVA FG Wilson Diesel Generator, 3 Phase
- 125 kVA FG Wilson Diesel Generator, 3 Phase
- 160 kVA FG Wilson Diesel Generator, 3 Phase
- 180 kVA FG Wilson Diesel Generator, 3 Phase
- 200 kVA FG Wilson Diesel Generator, 3 Phase
- 250 kVA FG Wilson Diesel Generator, 3 Phase
FG Wilson Diesel Generator
| Power (kVA) | 50 kVA |
| Genset Brand | FG Wilson |
| Model Number | FB50-2 |
| Phase | 3 Phase |
| Fuel Consumption (at 100% Load) | 11.74 Ltr/hr |
| Dry Weight (Kg) | 1700 |
| Frequency | 50 Hz |
| Rated Speed | 1500 RPM |
| Engine Model | FBD3-3.4D1 |
| Bore X Stroke | 107 X 126 mm |
| Fuel Tank Capacity | 200 Ltr |
| Compression Ratio | 17.5 / 1 |
| Displacement | 3.4 L |
| Lube Oil Capacity Approx | 6.5 L |
| Lube Oil Specification | 15W40 CH4 |
| Current | 69.6 Amps |
| Ip Rating | IP23 |
| Canopy Length | 3200 mm |
| Canopy Width | 1162 mm |
| Canopy Height | 1939 mm |
| Fuel System / Type | Mechanical / HSD |
| Cooling System Capacity | 14 L |
| Governing | Mechanical A2 |
| Number of Cylinders | 3 |
| Excitation System | Brushless |
| Number of Bearings | 1 |
| Voltage Regulation | +/- 1% |
| Insulation Class | Class H |
| Emission Compliance | CPCB II |
| Aspiration | TC |
Key Features:
- Designed exclusively for Indian conditions with good load acceptance.
- More fuel efficient and less vibration.
- Low maintenance cost.
- Low operating cost.
- High safeties and protections.
Generator Set Options
- WH - Coolant Heater
- PBCB - Static Battery Charger
- AH1 - Alternator Space Heater
- KWH - kWH with CT's
- ELCB - ELCB & Earth Fault Relays
- GE5 - Electronic Engine
Control Panel Options
- STDP - Standard Control Panel
- AMFB - AMF Panel with Double Breaker
- AMFS - AMF Panel with Single Breaker
- ATSM - Auto Start Panel with Manual Breaker Closing
View Complete Details
| Fuel Consumption (at 100% Load) | 14.12 Ltr/hr |
| Phase | 3 Phase |
| Model Number | FB62.5-2 |
| Genset Brand | FG Wilson |
| Power (kVA) | 62.5 kVA |
| Cooling System | Liquid Cooled |
| Frequency | 50 Hz |
| Dry Weight (Kg) | 1750 |
| Aspiration | TC-IC |
| Bore X Stroke | 107 X 126 mm |
| Fuel Tank Capacity | 200 Ltr |
| Displacement | 3.4 L |
| Engine Model | FBD3-3.4D2 |
| Compression Ratio | 17.5 / 1 |
| Lube Oil Capacity Approx | 6.5 L |
| Speed | 1500 RPM |
| Lube Oil Specification | 15W40 CH4 |
| Current | 87 Amps |
| Ip Rating | IP23 |
| Canopy Length | 3200 mm |
| Canopy Width | 1162 mm |
| Canopy Height | 1939 mm |
| Fuel System / Type | Mechanical / HSD |
| Cooling System Capacity | 14 L |
| Governing | Mechanical A2 |
| No of Cylinders | 3 |
| Excitation System | Brushless |
| No. of Bearings | 1 |
| Voltage Regulation | +/- 1% |
| Insulation Class | Class H |
Unique Features:
- Water in fuel sensor.
- Automatic belt tensioner.
- Hydraulic lash adjuster.
- Fuel theft alarm- 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Remote controlled monitoring through RS485 Port - 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Weather resistant, robust, reliable with the best quality enclosure in its segment.
- Compact design, light weight
- Genuine parts and service support
- Environmental friendly - Clean and Green.
Generator Set Options:
- WH - Coolant Heater
- PBCB - Static Battery Charger
- AH1 - Alternator Space Heater
- KWH - kWH with CT's
- ELCB - ELCB & Earth Fault Relays
- GE5 - Electronic Engine
Control Panel Options:
- TDP - Standard Control Panel
- AMFB - AMF Panel with Double Breaker
- AMFS - AMF Panel with Single Breaker
- ATSM - Auto Start Panel with Manual Breaker Closing
View Complete Details
| Power (kVA) | 82.5 kVA |
| Genset Brand | FG Wilson |
| Model Number | FB82.5-2 |
| Phase | 3 Phase |
| Fuel Consumption (at 100% Load) | 18.8 Ltr/hr |
| Dry Weight (Kg) | 1800 |
| Frequency | 50 Hz |
| Engine Model | FBD3-3.4D3 |
| Bore X Stroke | 107 X 126 mm |
| Fuel Tank Capacity | 200 Ltr |
| Compression Ratio | 17.5 / 1 |
| Displacement | 3.4 L |
| Lube Oil Capacity Approx | 6.5 L |
| Lube Oil Specification | 15W40 CH4 |
| Current | 114.8 Amps |
| Ip Rating | IP23 |
| Rpm | 1500 RPM |
| Canopy Length | 3200 mm |
| Canopy Width | 1162 mm |
| Canopy Height | 1939 mm |
| Fuel System / Type | Mechanical / HSD |
| Cooling System Capacity | 16 L |
| Governing | Mechanical A2 |
| No of Cylinders | 3 |
| Excitation System | Brushless |
| No. of Bearings | 1 |
| Voltage Regulation | +/- 1% |
| Insulation Class | Class H |
| Emission Compliance | CPCB II |
| Aspiration | TC-IC |
Key Features:
- Designed exclusively for Indian conditions with good load acceptance.
- More fuel efficient and less vibration.
- Low maintenance cost.
- Low operating cost.
- High safeties and protections.
Generator Set Options
- WH - Coolant Heater
- PBCB - Static Battery Charger
- AH1 - Alternator Space Heater
- KWH - kWH with CT's
- ELCB - ELCB & Earth Fault Relays
- GE5 - Electronic Engine
Control Panel Options
- STDP - Standard Control Panel
- AMFB - AMF Panel with Double Breaker
- AMFS - AMF Panel with Single Breaker
- ATSM - Auto Start Panel with Manual Breaker Closing
View Complete Details
| Brand | FG Wilson |
| Fuel Consumption (at 100% Load) | 21.3 Ltr/hr |
| Phase | 3 Phase |
| Model Number | FB100-2 |
| Genset Brand | FG Wilson |
| Power (kVA) | 100 kVA |
| Frequency | 50 Hz |
| Dry Weight (Kg) | 2200 |
| Engine Model | FBD4-4.5D1 |
| Bore X Stroke | 107 X 126 mm |
| Fuel Tank Capacity | 300 Ltr |
| Compression Ratio | 17.5/1 |
| Displacement | 4.5 L |
| Lube Oil Capacity Approx | 8.5 L |
| Lube Oil Specification | 15W40 CH4 |
| Current | 139 Amps |
| Ip Rating | IP23 |
| Rpm | 1500 RPM |
| No. of Bearings | 1 |
| Voltage Regulation | +/- 1% |
| Canopy Height | 2074 mm |
| Fuel System / Type | Mechanical / HSD |
| Cooling System Capacity | 17 L |
| Canopy Length | 3626 mm |
| Aspiration | TC-IC |
| Governing | Mechanical A2 |
| Excitation System | Brushless |
| Insulation Class | Class H |
| No of Cylinders | 4 |
| Emission Compliance | CPCB II |
| Canopy Width | 1126 mm |
Meets latest India CPCBII as per G.S.R 771(E) dated 11/12/2013 and its further amendments.
Unique Features:
- Water in fuel sensor.
- Automatic belt tensioner.
- Hydeaulic lash adjuster.
- Fuel theft alarm- 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Remote controlled monitoring through RS485 Port - 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Weather resistant, robust, reliable with the best quality enclosure in its segment.
- Compact design, light weight
- Genuine parts and service support
- Environmental friendly - Clean and Green.
Key Features:
· Designed exclusively for Indian conditions with good load acceptance.
· More fuel efficient and less vibration.
· Low maintenance cost.
· Low operating cost.
· High safeties and protections.
Generator Set Options
· WH - Coolant Heater
· PBCB - Static Battery Charger
· AH1 - Alternator Space Heater
· KWH - kWH with CT's
· ELCB - ELCB & Earth Fault Relays
· GE5 - Electronic Engine
Control Panel Options
· STDP - Standard Control Panel
· AMFB - AMF Panel with Double Breaker
· AMFS - AMF Panel with Single Breaker
· ATSM - Auto Start Panel with Manual Breaker Closing
View Complete Details
| Power (kVA) | 125 kVA |
| Genset Brand | FG Wilson |
| Model Number | FB125-2 |
| Phase | 3 Phase |
| Fuel Consumption (at 100% Load) | 26.43 Ltr/hr |
| Cooling System | Liquid Cooled |
| Dry Weight (Kg) | 2200 |
| Frequency | 50 Hz |
| Aspiration | TC-IC |
| Bore X Stroke | 107 X 126 mm |
| Fuel Tank Capacity | 300 Ltr |
| Displacement | 4.5 L |
| Engine Model | FBD4-4.5D2 |
| Compression Ratio | 17.5 / 1 |
| Lube Oil Capacity Approx | 8.5 L |
| Speed | 1500 RPM |
| Lube Oil Specification | 15W40 CH4 |
| Current | 174 Amps |
| Canopy Length | 3600 mm |
| Canopy Width | 1126 mm |
| Canopy Height | 2074 mm |
| Fuel System / Type | Mechanical / HSD |
| Cooling System Capacity | 17 L |
| Governing | Mechanical A2 Class |
| No of Cylinders | 4 |
| Excitation System | Brushless |
| No. of Bearings | 1 |
| Voltage Regulation | +/- 1% |
| Insulation Class | Class H |
Unique Features:
- Water in fuel sensor.
- Automatic belt tensioner.
- Hydraulic lash adjuster.
- Fuel theft alarm- 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Remote controlled monitoring through RS485 Port - 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Weather resistant, robust, reliable with the best quality enclosure in its segment.
- Compact design, light weight
- Genuine parts and service support
- Environmental friendly - Clean and Green.
Generator Set Options:
- WH - Coolant Heater
- PBCB - Static Battery Charger
- AH1 - Alternator Space Heater
- KWH - kWH with CT's
- ELCB - ELCB & Earth Fault Relays
- GE5 - Electronic Engine
Control Panel Options:
- STDP - Standard Control Panel
- AMFB - AMF Panel with Double Breaker
- AMFS - AMF Panel with Single Breaker
- ATSM - Auto Start Panel with Manual Breaker Closing
View Complete Details
| Power (kVA) | 160 kVA |
| Genset Brand | FG Wilson |
| Model Number | FB160-2 |
| Phase | 3 Phase |
| Fuel Consumption (at 100% Load) | 33.81 Ltr/hr |
| Dry Weight (Kg) | 2950 |
| Frequency | 50 Hz |
| Rated Speed | 1500 RPM |
| Engine Model | FBD6-6.8D1 |
| Bore X Stroke | 107 X 126 mm |
| Fuel Tank Capacity | 300 Ltr |
| Compression Ratio | 17.5 / 1 |
| Displacement | 6.8 L |
| Lube Oil Capacity Approx | 11.5 L |
| Lube Oil Specification | 15W40 CH4 |
| Current | 222.4 Amps |
| Ip Rating | IP23 |
| Canopy Length | 4550 mm |
| Canopy Width | 1460 mm |
| Canopy Height | 2130 mm |
| Fuel System / Type | Mechanical / HSD |
| Cooling System Capacity | 22 L |
| Governing | Mechanical A2 |
| No of Cylinders | 6 |
| Excitation System | Brushless |
| No. of Bearings | 1 |
| Voltage Regulation | +/- 1% |
| Insulation Class | Class H |
| Emission Compliance | CPCBII |
| Aspiration | TC-IC |
Key Features:
- Designed exclusively for Indian conditions with good load acceptance.
- More fuel efficient and less vibration.
- Low maintenance cost.
- Low operating cost.
- High safeties and protections.
Generator Set Options:
- WH - Coolant Heater
- PBCB - Static Battery Charger
- AH1 - Alternator Space Heater
- KWH - kWH with CT's
- ELCB - ELCB & Earth Fault Relays
- GE5 - Electronic Engine
Control Panel Options:
- STDP - Standard Control Panel
- AMFB - AMF Panel with Double Breaker
- AMFS - AMF Panel with Single Breaker
- ATSM - Auto Start Panel with Manual Breaker Closing
- SYNC - Synchronising Panel 1
View Complete Details
| Power (kVA) | 180 kVA |
| Genset Brand | FG Wilson |
| Model Number | FB180-2 |
| Phase | 3 Phase |
| Fuel Consumption (at 100% Load) | 38.08 Ltr/hr |
| Dry Weight (Kg) | 3000 |
| Frequency | 50 Hz |
| Engine Model | FBD6-6.8D2 |
| Bore X Stroke | 107 X 126 mm |
| Fuel Tank Capacity | 300 Ltr |
| Compression Ratio | 17.5 / 1 |
| Displacement | 6.8 L |
| Lube Oil Capacity Approx | 11.5 L |
| Lube Oil Specification | 15W40 CH4 |
| Current | 250.4 Amps |
| Ip Rating | IP23 |
| Rpm | 1500 RPM |
| Canopy Length | 4550 mm |
| Canopy Width | 1460 mm |
| Canopy Height | 2130 mm |
| Fuel System / Type | Mechanical / HSD |
| Cooling System Capacity | 22 L |
| Governing | Mechanical A2 |
| No of Cylinders | 6 |
| Excitation System | Brushless |
| No. of Bearings | 1 |
| Voltage Regulation | +/- 1% |
| Insulation Class | Class H |
| Aspiration | TC-IC |
| Emission Compliance | CPCB II |
Unique Features:
- Water in fuel sensor.
- Automatic belt tensioner.
- Hydraulic lash adjuster.
- Fuel theft alarm- 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Remote controlled monitoring through RS485 Port - 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Weather resistant, robust, reliable with the best quality enclosure in its segment.
- Compact design, light weight
- Genuine parts and service support
- Environmental friendly - Clean and Green.
Key Features:
· Designed exclusively for Indian conditions with good load acceptance.
· More fuel efficient and less vibration.
· Low maintenance cost.
· Low operating cost.
· High safeties and protections.
Generator Set Options
· WH - Coolant Heater
· PBCB - Static Battery Charger
· AH1 - Alternator Space Heater
· KWH - kWH with CT's
· ELCB - ELCB & Earth Fault Relays
· GE5 - Electronic Engine
Control Panel Options
· STDP - Standard Control Panel
· AMFB - AMF Panel with Double Breaker
· AMFS - AMF Panel with Single Breaker
· ATSM - Auto Start Panel with Manual Breaker Closing
View Complete Details
| Power (kVA) | 200 kVA |
| Genset Brand | FG Wilson |
| Model Number | FB200-2 |
| Phase | 3 Phase |
| Fuel Consumption (at 100% Load) | 45.9 Ltr/hr |
| Dry Weight (Kg) | 3050 |
| Frequency | 50 Hz |
| Engine Model | FBD6-6.8D3 |
| Fuel Tank Capacity | 300 Ltr |
| Compression Ratio | 17.5 / 1 |
| Displacement | 6.8 L |
| Lube Oil Capacity Approx | 11.5 L |
| Lube Oil Specification | 15W40 CH4 |
| Bore And Stroke | 107 / 126 mm |
| Current | 278.2 Amps |
| Ip Rating | IP23 |
| Rpm | 1500 RPM |
| Canopy Length | 4550 mm |
| Canopy Width | 1460 mm |
| Canopy Height | 2130 mm |
| Fuel System / Type | Mechanical / HSD |
| Cooling System Capacity | 27 L |
| Governing | Mechanical A2 |
| No of Cylinders | 6 |
| Excitation System | Brushless |
| No. of Bearings | 1 |
| Voltage Regulation | +/- 1% |
| Insulation Class | Class H |
| Aspiration | TC-IC |
| Emission Compliance | CPCB II |
Unique Features:
- Water in fuel sensor.
- Automatic belt tensioner.
- Hydraulic lash adjuster.
- Fuel theft alarm- 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Remote controlled monitoring through RS485 Port - 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Weather resistant, robust, reliable with the best quality enclosure in its segment.
- Compact design, light weight
- Genuine parts and service support
- Environmental friendly - Clean and Green.
Key Features:
· Designed exclusively for Indian conditions with good load acceptance.
· More fuel efficient and less vibration.
· Low maintenance cost.
· Low operating cost.
· High safeties and protections.
Generator Set Options
· WH - Coolant Heater
· PBCB - Static Battery Charger
· AH1 - Alternator Space Heater
· KWH - kWH with CT's
· ELCB - ELCB & Earth Fault Relays
· GE5 - Electronic Engine
Control Panel Options
· STDP - Standard Control Panel
· AMFB - AMF Panel with Double Breaker
· AMFS - AMF Panel with Single Breaker
· ATSM - Auto Start Panel with Manual Breaker Closing
View Complete Details
| Power (kVA) | 250 kVA |
| Genset Brand | FG Wilson |
| Model Number | FB250-2 |
| Phase | 3 Phase |
| Fuel Consumption (at 100% Load) | 55.3 Ltr/hr |
| Fuel Tank Capacity | 375 Ltr |
| Dry Weight (Kg) | 2890 |
| Frequency | 50 Hz |
Unique Features:
- Water in fuel sensor.
- Automatic belt tensioner.
- Hydraulic lash adjuster.
- Fuel theft alarm- 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Remote controlled monitoring through RS485 Port - 10 kVA - 37.5 kVA (optional) and 50 kVA - 200 kVA (standard).
- Weather resistant, robust, reliable with the best quality enclosure in its segment.
- Compact design, light weight
- Genuine parts and service support
- Environmental friendly - Clean and Green.
Generator Set Options:
- WH - Coolant Heater
- PBCB - Static Battery Charger
- AH1 - Alternator Space Heater
- KWH - kWH with CT's
- ELCB - ELCB & Earth Fault Relays
- GE5 - Electronic Engine
Control Panel Options:
- TDP - Standard Control Panel
- AMFB - AMF Panel with Double Breaker
- AMFS - AMF Panel with Single Breaker
- ATSM - Auto Start Panel with Manual Breaker Closing
View Complete Details
- Developed and Managed by IndiaMART InterMESH Limited