GE Healthcare ICU Ventilators
Power Source | 100 - 240 VAC / 47 - 63 Hz,12 VDC / 4.2 Ah (low tension) |
Weight | 14 Kg (Ventilator unit),25 Kg (Ventilator unit and trolley) |
Patient Age Group | Adults,Paediatric,Newborns |
Power Consumption | 50 Watt |
Temperature | +10 to +40 deg C (operating),-10 to +60 deg C (Storage) |
Relative Humidity | 30 - 95% non-condensing (Operating),less than 95% (Storage) |
Brand | Siare |
Dimension | 518 x 535 x 269 mm (Ventilator unit),555 x 1207 x 554 mm (Ventilator unit and trolley) |
Internal Battery | 2 batteries (Pb 12 Vdc - 1,3 Ah) |
Internal Battery Operation | 90 minutes max |
Optional External Battery Operation | 6 hours max |
Battery Recharging Time | About 8 hours |
External Electric Connections | 15 poles programming connector |
Siaretron 4000 lung ventilator is equipped with a TFT 12” colour monitor displaying the curves of pressure, flow, volume, the loops of breathing parameters, the trends and the ventilation parameters.
Siaretron 4000 lung ventilators is suitable for ventilation of adult, paediatric and neonatal patients. It is equipped with a flow and pressure trigger, it provides the most advanced volume controlled ventilation modalities VC/VAC, VC/VAC-BABY, pressure controlled ventilation modalities APCV (BILEVEL ST), APCV-TV, SIMV by Volume and by Pressure, Pressure supported modalities PSV (BILEVEL S), PSV-TV, CPAP SIGH, Non Invasive Ventilation (NIV), Drug Nebulizer and Manual Ventilation (MAN).
View Complete Details
Model | FALCO 202 Evo |
Weight | 5.5 Kg |
Cpap | From 3 to 50 cm H2O |
Temperature | From +10 to +40 deg C |
Relative Humidity | 30 - 95% non-condensing |
Brand | Siare |
Dimensions | 266 x 244 x 174 mm (W x H x D) |
Electric Power Supply | 100 to 240 AC / 47 to 63Hz |
Power | Max 150 Watt |
Battery Re Charging Time | About 24 hours |
Internal Battery Operation | Max 4 hours |
Internal Battery | Battery NiMh 12Vcc - 4.5 Ah |
IP Degree Of Protection | IP54 |
Falco 202 Evo is a lung ventilator conceived for use in emergency rooms, transport, intensive care units, and with patients affected by respiratory diseases and it is suitable for ventilation of adult, paediatric and neonatal (optional) patients. Falco 202 Evo is equipped with a flow generation system by turbine with separate cooling system granting higher quality and safety standards in patient ventilation. The Falco 202 Evo’s colour display shows the curves of pressure, flow, volume, loops of breathing parameters, trends and other ventilation parameters. The Falco 202 Evo is equipped with flow and pressure trigger, it provides the most advanced volume controlled ventilation modalities VC/VAC, VC/VAC- BABY, pressure controlled ventilation modalities APCV (BILEVEL ST), APCV- TV, SIMV by Volume and by Pressure, Pressure supported modalities PSV (BILEVEL S), PSV-TV, CPAP, SIGH, Non Invasive Ventilation (NIV), Drug Nebulizer and Manual Ventilation (MAN).
View Complete Details
Siare ICU Intensive Care Ventilator
Get Latest Price
Usage/Application | ICU |
Patient Age Group | Neonates to adults |
Type | Turbine-driven and gas-driven |
Warranty | 20,000 hours (turbine) |
Brand | Siare |
Footprint | 51.8 x 53.5 x 26.9 cm |
It is an advanced intensive care ventilator, designed to deliver long‑term respiratory support to a wide range of patients from neonates to adults. It is available in two versions – turbine-driven and gas-driven.
Features:
- Unique electromagnetic flow sensor to detect very low flows and handle a wide range of patients
- Integrated nebulizer that works on both O2 and normal air for enhanced drug delivery
- Advanced modes such as PSV-TV and APRV to supports patients with different complexities
- No preventive maintenance for up to 500 days, resulting in lower Total Cost of Ownership
- Advanced compressor that fits snugly inside the body of the machine
- Conveniently placed handle for better portability within the ICU
View Complete Details
Siare Falco Intensive Care and Transport Ventilator
Get Latest Price
Usage/Application | Hospital |
Brand | Siare |
Patient Age Group | Adult,Pediatric |
Display Type | TFT |
Display Size | 12 inch |
Battery Life | 4 to 8 hrs |
We are offering Siare Falco Intensive Care and Transport Ventilator to our clients.
View Complete Details
Product Details
Brand | Drager |
Model Name/Number | Savina |
Patient Age Group | Adult, Paediatric |
Tidal Volume | 0.05 to 2.0 L, BTPS |
Ventilation Mode | IPPV (CMV), IPPVAssist (CMVAssist), SIMV, SIMVASB (SIMV/PS), CPAP, CPAPASB (CPAP/PS), BIPAP1), (PCV+) (optional), BIPAP1)ASB (PCV+/PS) (optional) |
Respiratory Rate | 0 -150 bpm |
Additional Details
Power Supply | 100 V to 240 V, 50/60 Hz AC, 10 to 36 V DC |
Features
- Intuitive Operating System
- Scalable And Versatile Device
- Combine Fully-featured
- High-performance Ventilation With Infinity
- Acute Care System Integration
Application
- ICU, Critical Care And Transport
Clinical advancements in and out of the ICU
The Drager Savina is an advanced, high-quality ICU ventilator that offers excellent ventilation performance combined with easy operation. Designed for both adult and paediatric ventilation, the Savina provides advanced therapy at any acuity level.
Comprehensive safety concept
An integrated safety concept makes the Savina the natural choice for challenging environments, such as rural areas, earthquake zones or regions with erratic unreliable power grids. Its internal battery can bridge power failures of up to an hour, while an optional external battery can extend that range to 5 hours. Because air is supplied via an internal turbine, the Savina requires no external source of compressed air – perfect for settings with limited infrastructure or where frequent transports are necessary. Integrated safeguard sensors for minute volume, airway pressure and Oxygen concentration ensure enhanced patient safety.
Increased flexibility
The Savina gives you a full range of ventilation modes, both pressure- and volume-oriented, as well as pressure support, spontaneous breathing and non-invasive ventilation options. Built for adult and paediatric patients of all acuity levels, the Savina provides modern ventilation therapy for a very wide range of patients, situations and clinical settings.
Support the recovery process at every stage
The Savina’s AutoFlow feature brings the benefits of spontaneous breathing to volume-oriented modes. BIPAP1 combines pressure-oriented ventilation with spontaneous breathing at any time and at any pressure level. The Savina’s non-invasive ventilation capabilities are further enhanced by highly sensitive triggering and effective leak management systems. Together, these features can help you reduce ventilation times, promote the weaning process, avoid reintubation and reduce the rate of pulmonary complications related to intubation.
Simple and effective user interface
An intuitive user interface makes learning to use the Drager Savina easy. Simply select a parameter, change the parameter and confirm that change. Changes are visually supported on the high-resolution colour display. The Savina can also display your choice of static, dynamic, graphic or numeric real-time or trend data on an optional 12 inch colour touch screen.
View Complete Details
Product Details
Brand | GE |
Model Name/Number | Engstrom Carestation |
Patient Age Group | Adults, Pediatric Patients, Neonatal |
Tidal Volume | Neonatal: 2 to 350 ml, Adult/Pediatric: 20 to 2000 ml |
Ventilation Modes | VCV, PCV, PCV-VG, SIMV-VC, SIMV-PC, SIMV-PCVG (optional), APRV capable, BiLevel-VG (optional), NIV (optional), nCPAP, CPAP/PSV, VG-PS |
Respiratory Rate | Neonatal: 3 to 150 bpm for VCV, PCV, PCV-VG; 2 to 60 bpm for SIMV-VC, SIMV-PC, SIMV-PCVG Adult/Pediatric: 3 to 120 bpm for VCV, PCV, PCV-VG; 1 to 60 bpm for SIMV-VC, SIMV-PC, SIMV-PCVG |
Controls
Trigger | Flow trigger:- Neonatal: 0.2 to 1 L/min (increments of 0.05 L/min); Adult/Pediatric: 1 to 3 L/min (increments of 0.1 L/min), 3 to 9 L/min (increments of 0.5 L/min) Pressure trigger:- Adult/Pediatric: –10 to –3 cm H₂O (increments of 0.5 cm H₂O), –3 to –0.25 cm H₂O (increments of 0.25 cm H₂O) |
Flow | Neonatal: 0.2 to 30 L/min (0.004 to 0.5 L/sec), Pediatric: 2 to 90 L/min (0.04 to 1.5 L/sec), Adult: 2 to 160 L/min (0.04 to 2.6 L/sec) |
Maximum Peak Flow | 200 L/min |
Inspiratory/ Expiratory Ratio | Neonatal: 1:199 to 40:1 in BiLevel, Adult/Pediatric: 1:9 to 4:1 (ventilator setting), 1:79 to 60:1 in BiLevel |
Trigger Window | 0 to 80% of expiration time (increments of 5%) |
Bias Flow Rate | Neonatal: 2 to 15 L/min (increments of 0.5 L/min) for nCPAP; Adult/Pediatric: 2 to 10 L/min (increments of 0.5 L/min), 8 to 20 L/min for NIV (increments of 0.5 L/min) |
Settings
Inspiratory Pressure | 1 to 98 cm H₂O (increments of 1 cm H₂O) |
PEEP/CPAP | PEEP:- Neonatal: 2-15 cm H₂O (increments of 1 cm H₂O) in nCPAP Adult/Pediatric: Off, 1 to 50 cm H₂O (increments of 1 cm H₂O), 2-20 cm H₂O (increments of 1 cm H₂O) in NIV |
Inspiratory time | Neonatal: 0.1 to 10 sec, 0.1 to 1 sec (increments of 0.01), 1 to 4 sec (increments of 0.1), 4 to 10 sec (increments of 0.25) Adult/Pediatric: 0.25 to 15 sec, 0.25 to 1 sec (increments of 0.05), 1 to 4 sec (increments of 0.10), 4 to 15 sec (increments of 0.25) |
Expiratory time | Neonatal: 0.25 to 29.9 sec Invasive vent modes, Adult/Pediatric: 0.25 to 59.75 sec |
Monitoring
Peak Inspiratory Pressure | 7 to 100 cm H₂O (increments of 1 cm H₂O), 9-100 cm H₂O (increments of 1 cm H₂O) in NIV and nCPAP |
Ambient Conditions
Temperature (device) During Operation | 10° to 40°C |
Relative humidity During Operation | 15 to 95% RH Non-condensing |
Altitude | Operating range: –440 to 3565 m/500 to 800 mmHg, Storage range: –440 to 5860 m/375 to 800 mmHg |
Temperature During Storage & Transportation | –20° to 65°C |
Relative humidity During Storage & Transportation | 15 to 95% RH Non-condensing In accordance with IEC 68-2-3 |
Performance
Intermittent PEEP | High: 1 to 20 cm H₂O, Off |
Minute volume | Neonatal:- 0.01 to 10 L/min (low), 0.02 to 40 L/min (high) Adult/Pediatric:- 0.01 to 40 L/min (low), 0.4 to 99 L/min (high) |
Operating Data
Power Consumption | < 200 W |
Dimensions | 145 x 38 x 36 cm |
Weight | 31 kg (not including cart), 76 kg (including cart) |
Power Supply
Battery Type | Lead acid gel |
Alarm
Inspiratory O₂ concentration (FiO₂) | Adult/Pediatric:- 18 to 99% (low), 24 to 100%, Off (high) |
Airway Pressure | –20 to +120 cm H₂O |
Apnea alarm time | Neonatal:- 5 to 20 sec, Adult/Pediatric:- 10 to 60 sec |
Audible Alarm Volume Adjustable | 0, 10, 20 and 30 sec, Off |
High Inspiratory Pressure | 1 to 98 cm H₂O (increments of 1 cm H₂O) |
Low Inspiratory Pressure | Off, 1 to 50 cm H₂O (increments of 1 cm H₂O) |
High Respiratory Rate | Neonatal: 2 to 150/min, Off; Adult/Pediatric: 2 to 120/min, Off |
Circuit Leak | 10 to 90%, Off |
Escalating Alarms | High priority alarms escalate to a higher pitch if unattended for specified time |
Auto Limits | Alarm limits calculated on the current measured values for selected parameters |
Display Motion
Vertical Tilt | 160° in raised position, 60° in lowered position |
Height Adjustment | 23 cm / 9.1 inch |
Additional Details
Inspiratory Pressure Limit | 7 to 100 cm H₂O for VCV and SIMV-VC (increments of 1 cm H₂O) |
CO₂ production (VCO₂) | 50 to 1000 mL/min |
Rise time | 0 to 500 ms of inspiratory period for either flow or pressure depending on the mode selected. Active in VCV, PCV, PCV-VG, SIMV-VC, SIMV-PC, SIMV-PCVG, BiLevel-VG, NIV and BiLevel (increments of 50 ms) |
Features
- Simplified user interface
- Advanced ventilation
- Airway Resistance Compensation
- Built-in advanced nebulization system
- Multiple trolley configurations
Application
- Emergency Care & ICU
• Paramagnetic O₂ sensing
• Non-Invasive ventilation (Optional)
• Secure access to central stations
• Sophisticated power management control with battery backup
• Auxiliary pressure sensor
Integrated Ventilation and Monitoring
• INview Suite: SpiroDynamics and FRC INview
• Plug and play modules
• Patient Spirometry
• Gas monitoring with metabolics and energy expenditure
• Optional use of proximal Neo Flow Sensor with Neonatal ventilation
Exceptional Design
• Adaptable to your environment
• Flexible and moveable display
• Transferable module bay
• Quick-release expiratory valve
Aerogen Aeroneb Pro
• Operated in-line or independently for infants through adults
View Complete Details
Product Details
Brand | GE |
Model Name/Number | Versamed ivent 201 |
Patient Age Group | Adult, Pediatric |
Tidal Volume | 50 to 2000 ml |
Ventilation Modes | Assist control (A/C): Volume controlled, Pressure controlled; Synchronized intermittent mandatory ventilation (SIMV): Volume controlled, Pressure controlled; Continuous positive airway pressure (CPAP); Pressure support ventilation (PSV) |
Respiratory Rate | 1 to 80 bpm |
Controls
Flow | Adaptive Flow or 1 to 120 L/min; Spontaneous up to 180 L/min |
Synchronized Nebulizer | 5 to 240 min |
Settings
PEEP/CPAP | PEEP: 0 to 40 cm H₂O |
Inspiratory time | Adaptive I-Time or 0.2 to 3 sec |
Monitoring
Leakage | 0 to 100% |
Ambient Conditions
Temperature (device) During Operation | 0 to 50°C / 32 to 122°F |
Atmospheric pressure During Operation | 430 to 825 mm Hg (15,000 feet) |
Relative humidity During Operation | 15 to 95% at 30°C / 85°F |
Water/Dust Resistance | IP54 (splash proof) |
Temperature During Storage & Transportation | Without battery: -15 to +70°C / +5 to +158°F; With battery: -15 to +30°C / +5 to +86°F |
Vibration tested | IEC 68-2-6 and IEC 68-2-34, MIL-STD-810E |
Shock Compliance | IEC 68-2-27 (100 g), MIL-STD-810E |
Performance
Display unit size | 8.4 inch diagonal |
Operating Data
Internal battery | Sealed lead-acid 12 V (7.8 Ah) (rechargeable) |
Sound pressure level | 40 to 45 dBa at one meter |
Dimensions | 33 x 24 x 26 cm |
Weight | Overall Weight without battery: 8.3 kg; Overall weight with standard battery: 11.1 kg; Overall weight with optional extended internal battery: 12.6 kg |
Trigger sensitivity | 1 to 20 L/min flow sensitivity –0.5, to –20 cm H₂O pressure sensitivity |
Power Supply
AC/DC power pack | External AC: 100 to 240 V, 50 to 60 Hz, Max 1.6 A; External DC: 12 to 15 V, Max 8.5 A |
Operating time | Standard internal battery up to 2 hours depending on ventilatory parameters. Optional extended internal battery up to 4 hours depending on ventilatory parameters. Optional external battery up to 8 hours depending on ventilatory parameters |
Alarm
Inspiratory O₂ concentration (FiO₂) | 21 to 100% |
Apnea alarm time | 0 to 120 seconds |
Expiratory minute volume (MVe) | High/Low |
SpO₂ pulse | High / Low |
Additional Details
Supply pressure | High pressure supply: 40 to 75 psi (2.8 to 5.1 bar); Low pressure: Max 15 L/min or 0.5 psi |
Safety valve opening pressure | 80 cm H₂O |
Inspiratory Pressure Limit | 5 to 80 cm H₂O |
Standards | ASTM F1100-90, ASTM F1246-91, CSA C22.2 No. 601.1/601.2, IEC 60601-1, IEC 60601-1-2, EN 60601-2-12, EN 794-1/2/3, ISO 10651-1/2/3, UL 60601.1 |
PSV Pressure | 0 to 60 cm H₂O |
Esens | 10-90% |
Rise time | Mid/high/max/auto |
Features
- Apnea backup ventilation
- Adjustable rise time
- Closed loop flow & pressure controller
- Preset parameters by patient weight
Application
- Emergency Care & ICU
With its highly featured transport capability and rugged construction, the iVent201 takes ICU ventilation outside of the confines of the hospital. Optimized NIV and the Adaptive Bipap help caregivers maximize patient comfort and synchrony.
• Electrically powered, computer controlled ventilator
• Closed loop flow & pressure controller
• Adaptive Bi-Level (NIV)
• Adjustable rise time
• Easy Exhale
• Sigh breath
• 100% O₂ suction
Monitoring and Displayed Parameters
• Airway pressure (analog bar graph & numerical)
• Total breath rate
• I:E ratio
• Exhaled tidal volume
• Exhaled minute volume
• Peak flow
• Inspiratory time
• Electrical power source (AC/external DC/internal DC)
• Battery level
• Pressure, flow and volume Waveforms software package:Trending of monitored data (72 hours)
• Real-time pressure and flow waveforms
• Waveform history brows
• Respiratory mechanics (C, R, MAP, RR/Vt)SpO₂
• Pressure, flow and volume loops
View Complete Details
Product Details
Brand | GE |
Model Name/Number | Carescape R860 |
Patient Age Group | Adults, Pediatric Patients, Neonatal |
Tidal Volume | Adult: 100 to 2000 ml, Pediatric: 20 to 300 ml Neonatal: 2 to 50 ml |
Ventilation Modes | A/C VC, A/C PC, A/C PRVC, SIMV VC, SIMV PC, CPAP/PS, SBT, APRV, BiLevel, BiLevel VG, SIMV PRVC, VS, NIV, nCPAP |
Respiratory Rate | Neonatal: 3 to 150 bpm for A/C VC, A/C PC, A/C PRVC; 2 to 60 bpm for SIMV VC, SIMV PC, SIMV PRVC; Off, 1 to 30 bpm for nCPAP Adult/Pediatric: 3 to 120 bpm for A/C VC, A/C PC, A/C PRVC; 1 to 60 bpm for SIMV VC, SIMV PC, SIMV PRVC |
Controls
Trigger | Flow trigger:- Neonatal: 0.2 to 1 L/min (increments of 0.05 L/min), 1 to 3 L/min (increments of 0.1 L/min), 3 to 9 L/min (increments of 0.5 L/min); Adult/Pediatric: 1 to 3 L/min (increments of 0.1 L/min), 3 to 9 L/min (increments of 0.5 L/min) Pressure trigger:- Adult/Pediatric: –10 to –3 cm H₂O (increments of 0.5 cm H₂O), –3 to –0.25 cm H₂O (increments of 0.25 cm H₂O) |
Pressure Support | 0 to 60 cm H₂O for SIMV VC, SIMV PC, SIMV PRVC, BiLevel, BiLevel VG and CPAP/ PS (increments of 1 cm H₂O), 0 to 30 cm H₂O for NIV (increments of 1 cm H₂O) |
Flow | Neonatal: 0.2 to 30 L/min, Pediatric: 2 to 72 L/min, Adult: 2 to 160 L/min |
Maximum Peak Flow | Adult: 208 L/min; Pediatric: 100 L/min; Neonatal: 30 L/min |
Inspiratory/ Expiratory Ratio | Neonatal: 1:199 to 40:1 in BiLevel and APRV, Adult/Pediatric: 1:79 to 60:1 in BiLevel and APRV |
Trigger Window | 80% of expiration time |
Bias Flow Rate | Neonatal: 2 to 15 L/min (increments of 0.5 L/min) for nCPAP; Adult/Pediatric: 2 to 10 L/min (increments of 0.5 L/min), 8 to 20 L/min for NIV (increments of 0.5 L/min) |
Settings
Inspiratory Pressure | Neonatal: 1 to 25 cm H₂O (increments of 1 cm H₂O) in nCPAP; Adult/Pediatric: 1 to 98 cm H₂O (increments of 1 cm H₂O) |
PEEP/CPAP | PEEP:- Neonatal: 2-15 cm H₂O (increments of 1 cm H₂O) in nCPAP Adult/Pediatric: Off, 1 to 50 cm H₂O (increments of 1 cm H₂O), 2-20 cm H₂O (increments of 1 cm H₂O) in NIV |
Inspiratory time | Neonatal: 0.1 to 10 sec, 0.1 to 2 sec in nCPAP, 0.1 to 1 sec (increments of 0.01), 1 to 4 sec (increments of 0.1), 4 to 10 sec (increments of 0.25) Adult/Pediatric: 0.25 to 15 sec, 0.25 to 5 sec in NIV, 0.25 to 1 sec (increments of 0.05), 1 to 4 sec (increments of 0.1), 4 to 15 sec (increments of 0.25) |
Expiratory time | Neonatal: 0.25 to 29.9 sec Invasive vent modes, Adult/Pediatric: 0.25 to 59.75 sec |
Monitoring
Peak Inspiratory Pressure | 7 to 100 cm H₂O (increments of 1 cm H₂O), 9 to 100 cm H₂O (increments of 1 cm H₂O) in NIV and nCPAP |
Ambient Conditions
Temperature (device) During Operation | 10° to 40°C |
Relative humidity During Operation | 15 to 95% RH Non-condensing |
Altitude | Operating range: –400 to 3000 m/525 to 800 mmHg , Storage range: –400 to 5860 m/375 to 800 mmHg |
Temperature During Storage & Transportation | –20° to 60°C |
Relative humidity During Storage & Transportation | 15 to 75% RH Non-condensing |
Performance
Intermittent PEEP | High: 1 to 20 cm H2O, Off |
Minute volume | Low: 0.01 to 40 L/min, High: 0.02 to 99 L/min |
Operating Data
Power Consumption | < 200 VA |
Dimensions | 151.77 x 38 x 36 cm |
Weight | 31 kg (not including cart), 78 kg (including cart) |
Power Supply
Battery Type | Lead acid gel |
Alarm
Inspiratory O₂ concentration (FiO₂) | Low: 18 to 99%, High: 24 to 100%, Off |
Airway Pressure | –20 to +120 cm H₂O |
Apnea alarm time | 5 to 60 seconds |
Audible Alarm Volume Adjustable | 0, 10, 20 and 30 sec, Off |
High Inspiratory Pressure | 1 to 98 cm H₂O (increments of 1 cm H₂O) |
Low Inspiratory Pressure | Off, 1 to 50 cm H₂O (increments of 1 cm H₂O) |
High Respiratory Rate | 2 to 150/min, Off |
Circuit Leak | 10 to 90%, Off |
Escalating Alarms | High priority alarms escalate to a higher pitch if unattended for specified time |
Auto Limits | Alarm limits calculated on the current measured values for selected parameters |
Display Motion
Vertical Tilt | 162.1° in raised position, 47.6° in lowered position |
Height Adjustment | 24.95 cm / 9.8 inch |
Additional Details
Inspiratory Pressure Limit | 7 to 100 cm H₂O for A/C VC and SIMV VC (increments of 1 cm H₂O) |
CO₂ production (VCO₂) | 20 to 1000 mL/min |
Rise time | 0 to 500 ms of inspiratory period for pressure supported breaths only. Active in SIMV VC, SIMV PC, SIMV PRVC, CPAP/PS, BiLevel VG, BiLevel and VS (increments of 50 ms) |
Features
- Lung Protection Strategy
- Innovative user interface
- Menu-free navigation
- Measuring Functional Residual Capacity
Application
- Emergency Care & ICU
Featuring expert user tools and an innovative user interface, the Carescape R860 is inherently familiar the first time you use it.
Navigating past, present and future states of your ventilated patients is the foundation of the Carescape R860 user interface. From the center workspace view that highlights current patient status, you can swipe left to right to navigate from historical trends on the left (past) to Clinical Decision Support tools on the right (future). Your settings are recalled even as you navigate across workspaces.
By replacing menus with workspace views, the Carescape R860 has flattened the learning curve and unlocked ventilation capabilities by making them more accessible and easier to use.
View Complete Details