Have a requirement?
Get Best Price
Have a requirement?
Get Best Price
Our Products
- Hach EZ Series Fluoride Analysers
- Hach EZ Series Manganese Analysers
- Hach EZ Series Mercury Analysers
- Hach EZ Series Nitrate Analysers
- Hach EZ Series Phosphate Analysers
- Hach EZ Series TOC Analysers
- Hach EZ Series Total Nitrogen Analysers
- Hach EZ Series Toxicity Analysers
- Hach EZ Series Chlorine Analysers
- Hach EZ Series Cyanide Analysers
- Hach EZ Series Hardness Analysers
- Hach EZ Series Hydrogen Peroxide Analysers
- Hach EZ Series Iron Analysers
- Hach EZ Series Lead Analysers
- Hach EZ Series Nitrite Analysers
- Hach EZ Series Phenol Analysers
- Hach EZ Series Sample Preconditioning Analyzers
- Hach EZ Series Silica Analysers
- Hach EZ Series Sulphate Analysers
- Hach EZ Series Sulphide Analysers
- Hach EZ Series Total Phosphorus Analysers
- Hach EZ Series Volatile Fatty Acids Analysers
- Hach EZ Series Copper Analysers
- Hach EZ Series Color Analysers
- Hach EZ Series Chromium Analysers
- Hach EZ Series Chloride Analysers
- Hach EZ Series Cadmium Analysers
- Hach EZ Series COD Analysers
- Hach EZ Series Boron Analysers
- Hach EZ Series Arsenic Analysers
- Hach EZ Series Ammonium Analysers
- Hach EZ Series Aluminium Analysers
- Hach EZ Series Alkalinity Analysers
- Hach EZ Series ATP Analysers
- Hach EZ Series Zinc Analysers
Hach EZ Analyzers
Brand | Hach |
Alarm | 1x malfunctioning,4x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Automatic Cleaning | Yes |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 5 minutes |
Demineralised Water | For rinsing |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Interferences | Metal ions like aluminium > 72 mg/L,calcium > 108 mg/L and iron > 150 mg/L. Fats,oil,proteins,su |
Lower Limit of Detection (LOD) | less than equal to 0.1 mg/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Fluoride |
Power | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 1 - 10 mg/L F- Optional: 0.25 - 2.5 mg/L F- 0.5 - 5 mg/L F- |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online ion-selective Fluoride measurements in industrial and environmental applications
ISE technology for optimal analytical performanceWith limited maintenance requirements and reduced reagent consumption, the EZ3000 Series are the ideal choice for a wide range of water monitoring applications where ion-selective electrodes are the preferred analytical technique. Outstanding precision and stability is guaranteed by the temperaturecontrolled measurement.
Direct, discontinuous ISE method
Contrary to separate electrodes or other analysers in the market, the EZ3000 Series does not run a continuous measurement. The principle of discontinuous ISE analysis not only enhances control over conversion of ion activity to electric potential, it also eliminates risk of cross-contamination between cycles and reduces overall consumption of reagents.
The EZ3000 Series combine unique ISE technology with a set of analysis, control and communication features in an industrial analyser mainframe with designed for the highest performance:
- Automatic direct ion-selective measurements
- Smart automatic features
- Control and communication via industrial panel PC
- Standard 4 - 20 mA signal output with alarm processing
- Communication ports supporting connectivity to Modbus
- Multiple stream analysis
- Reduced reagent consumption
What''s included?
EZ3007 Fluoride Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x ISE Fluoride Electrode and 1 x empty 2.5L Reagent Container with Fittings (for Buffer Solution)
Measurement method:
Discontinuous, direct measurement by combined ion-selective electrode, conform with standard methods EPA 9214 and ASTM D1179
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 min (dilution + 5 min) |
Demineralised Water | For rinsing / dilution |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Interferences | Large amounts of colour and turbidity interfere. Fats,oil,proteins,surfactants and tar. |
Lower Limit of Detection (LOD) | less than equal to 2 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass Wall section: Galvanised steel,powder coated |
Measurement Method | Colorimetric measurement using formaldoxime method at 450 nm |
Model | EZ1025 |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Manganese Mn(II),dissolved |
Power | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 5 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online colorimetric analysis of dissolved Manganese in water
EZ1000 Manganese Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Manganese Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1025 Manganese Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 3 x empty 2.5L Reagent Containers with Fittings (for Colour, Buffer & Reductor Solution) and 1 x empty 10L Reagent Container with Fittings (for EDTA Solution)
Range:
0.01 - 1 mg/L Mn(II)
Optional:
0.002 - 0.1 mg/L Mn(II)
0.005 - 0.25 mg/L Mn(II)
0.005 - 0.5 mg/L Mn(II)
0.08 - 4 mg/L Mn(II) (with internal dilution)
0.16 - 8 mg/L Mn(II) (with internal dilution)
1 - 100 mg/L Mn(II) (with internal dilution)
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic, 2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 minutes |
Demineralised Water | For rinsing |
Drain | Atmospheric pressure, vented, min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 1 micro g/L |
Material | Hinged part: Thermoform ABS, door: plexiglass Wall section: Galvanised steel, powder coated |
Measurement Method | Stripping voltammetry using gold electrode |
Model | EZ6009 |
Number of Sample Streams | 1 stream Optional: 1 to 6 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs Modbus TCP/IP |
Parameter | Mercury, dissolved Hg(II) |
Power | 100 - 240 VAC, 50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 5% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 1 - 20 micro g/L Hg(II) |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m, < 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Trace metal analysis of dissolved Mercury Hg(II) in water by online voltammetry
The EZ6000 Series of Online Trace Metal Analysers are based on the technology of stripping voltammetry, a sensitive analytical technique that can be automated for the determination of trace levels of metals in water. For many metals the EZ6000 Series boasts limits of quantification in the low ppb range, comparing the technique favorably with AAS or ICP analysis.
Single, multiple and total parameter configurations
Several product sublines with a wealth of combinations are available for determination of trace metals, including the standard single parameter and multi-parameter configurations without digestion. Measurement of complexed or adsorbed metals is possible by means of the configurations with built-in digester. Combinations of metals depend on the choice of working electrode and the priority metals for your application.
Advanced features
The EZ6000 Series build upon tried and tested voltammetry technology used in many clean water applications, in an industrial mainframe with the following prime features:
- Excellent selectivity and sensitivity
- Built-in sample digestion unit (hot acid or UV)
- Smart automatic features
- Standard 4 - 20 mA signal output with alarm processing
- Communication ports supporting connectivity to Modbus
- Higher measuring ranges: internal sample dilution
- Multiple stream analysis
What's included?
EZ6009 Mercury Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and empty Containers for Reagents with Fittings
Interferences:
Iron (II),(III) in mg/L levels, antimony (III) in µg/L levels, organic matter may interfere. Fats, oil, proteins, surfactants and tar.
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic, 2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 min |
Demineralised Water | For rinsing / dilution |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure, vented, min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 0.2 mg/L |
Material | Hinged part: Thermoform ABS, door: plexiglass, Wall section: galvanised steel, powder coated |
Measurement Method | Colorimetric measurement at 546 nm using NEDD, conform with standard method ASTM 4500-NO3-A |
Model | EZ1029 |
Number of Sample Streams | 1 stream |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs Modbus TCP/IP |
Parameter | Nitrate |
Power | 100 - 240 VAC, 50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 3% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP66 |
Range | 0.2 - 10 mg/L NO3-N |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m, < 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online colorimetric analysis of Nitrate in water
EZ1000 Nitrate Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Nitrate Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What's included?
EZ1029 Nitrate Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Reagent Container with Fittings (for Sulfamic Acid & Buffer Solution), 1 x empty 5L Reagent Container with Fittings (for Reductor Solution) and 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour Solution)
Interferences:
Ions like Antimony Sb(III), Bismuth, Chloroplatinate, Gold, Iron Fe(III), Lead, Mercury, Metavanadate, Silver can precipitate with Nitrate. Presence of Copper Cu(II) may decompose the diazonium salt which results in a low result. Strong oxidizing agents. Tricloramine results in a false red colour. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts |
Ambient Temperature | 10 - 30 DegreeC, +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic, 2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 DegreeC; pressure max. 0.5 bar |
Cycle Time | 30 min including digestion of 10 min (standard) |
Demineralised Water | For rinsing |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure, vented, min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 10 micro g/L |
Material | Hinged part: Thermoform ABS, door: plexiglass Wall section: Galvanised steel, powder coated |
Number of Sample Streams | 1 stream |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs Modbus TCP/IP |
Parameter | Phosphorus, total |
Power | 120 VAC, 50/60 Hz Max. power consumption: 440 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 0.01 - 2 mg/L TP |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m, < 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online, automatic monitoring of Total Phosphorus (TP) in wastewater and general water applications
The EZ7800 Series of Online TP Analysers meet the needs for fast, convenient and reliable monitoring of the regulatory sum parameter Total Phosphorus in municipal and industrial wastewater as well as surface water applications. The EZ7800 Series share similar technology with the EZ7700 Series which monitor Total Nitrogen.
Phosphorus is often synonymous with phosphate but can be present in different forms: orthophosphate (O-phosphate), condensed phosphate (polyphosphate) or organically bonded phosphate. O-phosphate is often the only form that is measured with traditional test kits or even in laboratory, yet the organic form of phosphate can be an important constituent of industrial discharges, often deriving from corrosion control programs or use of fertilisers. In summary, knowing levels of TP can be an important added value to waste water operations.
The EZ7800 Online Total Phosphorus Analyser allows operators of industrial and municipal water works to monitor and control in a convenient way the total portion of phosphorous, if needed combined with a free phosphate measurement. The analyser’s industrial mainframe harnesses a proprietary sample digestion technique combined with a proprietary sample digestion technique combined with seamless operation:
- Full oxidation of all complexed phosphate
- Smart automatic features
- Control and communication via industrial panel PC
- Standard 4 - 20 mA signal output with alarm processing
- Communication supporting Ethernet connectivity to Modbus TCP/IP
- Multiple stream analysis
What's included?
EZ7800 Total Phosphorus Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and empty Containers for Reagents with Fittings.
Interferences:
Arsenicum (V), Chromium (VI), Copper (II) > 10 mg/L, Iron (III) > 10 mg/L, Sulphide > 2 mg/L, and Vanadium (V), Silica > 60 mg/L. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Measurement method:
Colorimetric measurement at 630 nm using ascorbic acid reduction and molybdate colour solution after persulphate digestion in acidic medium, conform with APHA 4500-P
View Complete Details
Brand | Hach |
Measuring Range | 0.4 - 20 mg/L C |
Limit of Detection | <= 0.2 mg/L |
Measuring Cycle | 15 - 30 minutes |
Operating Flow-rate | 100 - 300 mL/min |
Alarm | 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic, 2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 DegreeC; pressure max. 0.5 bar |
Demineralised Water | For rinsing |
Digital Outputs | Modbus RS485 |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure, vented, min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Material | Hinged part: Thermoform ABS, door: plexiglass Wall section: Galvanised steel, powder coated |
Measurement Method | Hot UV/persulphate method, conform with ISO 8245, USEPA 415.2, ASTM D4839-03 and DIN-EN 1484 |
Number of Sample Streams | 1 stream |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs Modbus TCP/IP |
Power | 120 VAC, 50/60 Hz Max. |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Sample Pressure | By external overflow vessel |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online, automatic TOC or TC monitoring for wastewater and surface water applications
Proprietary discontinuous analysis
The EZ7100 Series are designed to run a discontinuous analysis on Total Organic Carbon or Total Carbon levels, reducing significantly reagent consumption but also overall maintenance costs. Additionally a rinsing or cleaning cycle can be introduced to eliminate cross-contamination and fouling.Smart features and reduced calibration intervalsIn the controller-database software, all necessary smart automatic features are already embedded: auto-calibration, auto-validation, auto-cleaning and auto-priming. In order to assure optimal analytical performance, it is recommended to calibrate the EZ7100 Series monthly or quarterly simply by starting the calibration sequence via the panel PC.The mainframe of the EZ 7100 Series is a compact and straightforward design running a hot UV/persulphate destruction for determination of organic purity in various water applications, with the following distinctive features:-
- Options for TOC or TC analysis
- Discontinuous analysis with programmable frequency
- Smart automatic features
- Control and communication via industrial panel PC
- Standard 4 - 20 mA signal output with alarm processing
- Communication ports supporting connectivity to Modbus
- Multiple stream analysis
What's included?
EZ7100 TOC Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, and 2 x empty 10L Reagent Containers with Fittings (Acid & Persulphate Solution)
Interferences:
Chloride > 1 g/L affects oxidation efficiency. Volatile organic compounds evaporate in the TOC configuration. Fats, oil, proteins, surfactants and tar.
Specifications:
Alarm:1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Ambient Temperature:10 - 30 °C ±4 °C deviation at 5 - 95% relative humidity (non-condensing)
Calibration:Automatic, 2-point; frequency freely programmable
Certifications:CE compliant / UL certified
Cooling water:Flow rate approx. 5 L/h; temperature max. 30 °C; pressure max. 0.5 bar
Cycle Time:15 - 30 minutes, depending on range; frequency freely programmable
Demineralised water:For rinsing
Digital outputs:Modbus RS485
Drain:Atmospheric pressure, vented, min. Ø 64 mm
Earth connection:Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Instrument air:Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferences:Chloride > 1 g/L affects oxidation efficiency. Volatile organic compounds evaporate in the TOC configuration. Fats, oil, proteins, surfactants and tar.
Lower Limit of Detection (LOD):≤ 0.2 mg/L
Material:Hinged part: Thermoform ABS, door: plexiglass
Wall section: Galvanised steel, powder coated
Measurement method:Hot UV/persulphate method, conform with ISO 8245, USEPA 415.2, ASTM D4839-03 and DIN-EN 1484
Number of sample streams:1 stream
Optional:
1 to 8 streamsOutput:Modbus RS485 Modbus RS485
Optional:
Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs
Modbus TCP/IP
Parameter:TOC (Total Organic Carbon)
Power:120 VAC, 50/60 Hz
Max. power consumption: 440 VA
Power supply:120 VAC, 50/60 Hz
Precision:Better than 2% full scale range for standard test solutions
Protection Class:
Analyser cabinet: IP55 /
Panel PC: IP65
Range:0.4 - 20 mg/L C 0.4 - 20 mg/L C
Reagent Requirements:Keep between 10 - 30 °C
Sample Flow Rate:100 - 300 mL/min
Sample Pressure:By external overflow vessel
Sample Temperature:10 - 30 °C
Validation:Automatic; frequency freely programmable
View Complete Details
Model Name/Number | EZ7700 |
Brand | Hach |
Warranty | 2 years |
Weight | 25 kg |
Power Requirements | 120 VAC, 50/60 Hz Max. power consumption: 440 VA |
Alarm | 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts |
Ambient Temperature | 10 - 30 DegreeC, +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic, 2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 DegreeC; pressure max. 0.5 bar |
Cycle Time | 30 min including digestion of 10 min (standard) |
Demineralised Water | For rinsing |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure, vented, min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 100 micro g/L |
Material | Hinged part: Thermoform ABS, door: plexiglass Wall section: Galvanised steel, powder coated |
Number of Sample Streams: | 1 stream |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs Modbus TCP/IP |
Parameter | Nitrogen, total |
Precision | Better than 4% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 0.1 - 2 mg/L TN |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m, < 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Online, automatic monitoring of Total Nitrogen (TN) in wastewater and general water applications
The EZ7700 Series of Online TN Analysers meet the needs for fast, convenient and reliable monitoring of the regulatory sum parameter Total Nitrogen in wastewater and surface water applications.
Ammonia, nitrate and nitrite are three key nitrogen species that play an important role in decomposition of organic material in water and biological water treatment in particular. While data on individual levels of these provide operators of WWTP’s insight in the biochemical processes, other organic and inorganic forms of nitrogen may also be of significance. Total Kjeldahl Nitrogen (TKN) was originally developed as a measure of organic nitrogen but in practice it was often considered as synonymous with Total Nitrogen (TN) due to the lack of other available technologies. Still today, TN is often confused with TKN.
The EZ7700 Series of Online TN Analysers were developed in the framework of a research project to provide operators and utilities a viable alternative for the complex and time-consuming TKN method. TN as measured by the EZ7700 comprises all components, organic and inorganic, of the nitrogen cycle by the analyser’s proprietary sample digestion technique, now available in an industrial mainframe with a compact footprint:
- Full oxidation of all nitrogen species
- Smart automatic features
- Control and communication via industrial panel PC
- Standard 4 - 20 mA signal output with alarm processing
- Communication supporting Ethernet connectivity to Modbus TCP/IP
- Multiple stream analysis
What's included?
EZ7700 Total Nitrogen Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Reagent Container with Fittings (Buffer Solution), 2 x empty 5L Reagent Containers with Fittings (Oxidation B & Reductor Solution), 1 x empty 10L Reagent Container with Fittings (Oxidation A Solution) and 1 x empty 2.5L Glass Reagent Container with Fittings (Colour Solution)
Interferences:
Antimony (III), Bismuth (III), Chloroplatinate, Gold (III), Iron (III), Lead (II), Mercury (II), Metavanadate, and Silver (I) can precipitate with Nitrate. The presence of Copper (II) may decompose the diazonium salt which results in a low result. Strong oxidising agents. NCl??? results in a false red colour. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Measurement method:
Colorimetric measurement at 546 nm using hydrazine reduction and NEDD colour solution after persulphate digestion in alkaline medium, conform with APHA 4500-N
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic; standard at every analysis cycle |
Certifications | CE compliant / UL certified |
Cycle Time | 10 - 15 minutes |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure, vented, min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Material | Hinged part: Thermoform ABS, door: plexiglass Wall section: Galvanised steel, powder coated |
Measurement Method | Respirometry |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs Modbus TCP/IP |
Parameter | Toxicity; respiration rate |
Power | 100 - 240 VAC, 50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 5% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 0 - 100 % inhibition |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 Kg |
Online, automatic respirometry for early warning of toxicity in wastewater treatment plants
Early Warning System against calamities
The EZ7900 Online Toxicity Analyser is able to detect and measure waste water streams that present an acute or chronic toxicity to the biomass of a water treatment plant. This allows operators to take corrective measures to protect the viability of the activated sludge.
Representative measurements on fresh sludge
Measurements are carried out on real sludge freshly sampled from the treatment plant by means of a self-cleaning sampling-filtration system (option). This unique approach has the following advantages: dynamic changes in biomass viability are immediately detected, while sample temperature and pH in the analysis vessel reflects those of the treatment plant.
The EZ7900 Series combine a unique, field-proven respirometric analyser design with a robust sampling-filtration system, assuring detection of toxic compounds or shock loads in an early stage:
- Detection of acute and chronic toxicity on activated sludge
- Measurement of the respiration rate by means of a single dissolved oxygen (DO) sensor
- Smart automatic features
- Standard 4 - 20 mA signal output with alarm processing
- Communication ports supporting connectivity to Modbus
- Multiple stream analysis
What's included?
EZ7900 Toxicity Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and empty Containers for Reagents with Fittings.
Sample Quality:
Maximum particle size 500 µm, < 0.1 g/L
Most applications require the use of a dual EZ9110 + EZ9120 sampling/filtration system.
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic, 2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 6 min (dilution + 5 min.) |
Demineralised Water | For rinsing / dilution |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure, vented, min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 5 micro g/L |
Material | Hinged part: Thermoform ABS, door: plexiglass, Wall section: galvanised steel, powder coated |
Measurement Method | Colorimetric measurement at 510 nm using DPD, conform with standard method ASTM 4500-Cl-G |
Model | EZ1006 |
Number of Sample Streams | 1 stream |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs Modbus TCP/IP |
Parameter | Free Chlorine |
Power | 100 - 240 VAC, 50/60 Hz, Max. power consumption: 120 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP66 |
Reagent Requirements | Keep refrigerated. |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m, < 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online colorimetric analysis of Free Chlorine in water
EZ1000 Free Chlorine Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Free Chlorine Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What's included?
EZ1006 Chlorine Analyser, Instruction Manual, 1 x Double Door Bit Key, 1 x Mounting Brackets, 1 x empty 5L Reagent Container with Fittings (for Buffer Solution) and 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour Solution)
Interferences:
Oxidants like Bromine, Bromamine, Copper Cu(II) >8 mg/L, Chromate, Hydrogen peroxide, Iodine, Iodoamines, Iron Fe(III) >20 mg/L, Nitrite, Ozone and Manganese may oxidize the DPD colour solution.
Iodide and Bromide will interfere with determination of free Chlorine.
Reduced forms of these components – Chloride, Manganous ion Mn(II) and Oxygen – do not interfere.
Organic contaminants may produce a false Free chlorine reading.
Chlorine dioxide will be detected as Total Chlorine.
Reducing agents such as Ferrous compounds, Hydrogen, Sulphide and oxidizable organic matter generally do not interfere.
Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Range:
0.025 - 1.5 mg/L Cl2
Optional:
5 - 150 µg/L
10 - 375 µg/L
10 - 750 µg/L
0.2 - 6 mg/L (with internal dilution)
0.4 - 12 mg/L (with internal dilution)
2.5 - 150 mg/L (with internal dilution)
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Automatic Cleaning | Yes |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 20 min (dilution + 5 min) |
Demineralised Water | For rinsing / dilution |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 1 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Model | EZ1012 |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Cyanide,free |
Power | 100 - 240 VAC,50/60 Hz,Max. power consumption: 120 VA |
Precision | Better than 5% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online colorimetric analysis of free Cyanide in water
EZ1000 Free Cyanide Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Free Cyanide Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1012 Cyanide Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and 2 x empty 2.5L Reagent Containers with Fittings (for Buffer and Chloramine Solution) and 1 x empty 2.5L Glass Reagent Contaner with Fittings (for Colour Solution)
Interferences:
Ions like Nitrite > 5 mg/L, Sulphide > 100 mg/L and Sulphite. Thiocyanate will cause high results. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Measurement method:
Colorimetric measurement at 578 nm using chloramine T method, conform with standard method APHA 4500-CN €
Range:
5 - 200 µg/L CN
Optional:
1 - 20 µg/L CN
2 - 50 µg/L CN
2 - 100 µg/L CN
0.04 - 0.8 mg/L CN (with internal dilution)
0.08 - 1.6 mg/L CN (with internal dilution)
0.5 - 20 mg/L CN (with internal dilution)
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 min (dilution + 5 min.) |
Demineralised Water | For rinsing / dilution |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. DIa. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 2.5 micro g/L CaCO3 |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: galvanised steel,powder coated |
Measurement Method | Colorimetric measurement at 610 nm using calmagite/EDTA |
Model | EZ1016 |
Number of Sample Streams | 1 stream |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Total Hardness |
Power | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP66 |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online colorimetric analysis of Total Hardness in water
EZ1000 Total Hardness Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Total Hardness Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1016 Hardness Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and 4 x empty 2.5L Reagent Containers with Fittings (for Colour, Acid, Buffer and EDTA Solution)
Interferences:
Some metal ions interfere by causing fading or indistinct end points or by stoichiometric consumption of EDTA. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Range:
0.025 - 1 mg/L CaCO3
Optional:
0.0025 - 0.1 mg/L
0.005 - 0.25 mg/L
0.005 - 0.5 mg/L
0.2 - 4 mg/L (with internal dilution)
0.4 - 8 mg/L (with internal dilution)
2.5 - 100 mg/L (with internal dilution)
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Automatic Cleaning | Yes |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 min (dilution + 5 min.) |
Demineralised Water | For rinsing / dilution |
Digital Outputs | Modbus RS485 |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Online colorimetric analysis of Hydrogen Peroxide (H2O2) in water
EZ1000 Hydrogen Peroxide Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Hydrogen Peroxide Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1022 Hydrogn Peroxide Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and 2 x empty 2.5L Glass Containers with Fittings (for Colour and Buffer Solution)
Interferences:
Oxidants like Bromine, Bromamine, Chlorine, Copper Cu(II) > 8 mg/L, Chromate, Iodine, Iodoamines, Iron Fe(III) > 20 mg/L, Nitrite, Ozone and Manganese may oxidize the DPD colour solution. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Range:
5 - 500 µg/L H2O2
Optional:
2 - 125 µg/L
2 - 250 µg/L
0.04 - 2.0 mg/L (with internal dilution)
0.08 - 4.0 mg/L (with internal dilution)
0.5 - 50 mg/L (with internal dilution)
View Complete Details
Weight | 25 kg |
Power Supply | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Automatic Cleaning | Yes |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 DegreeC; pressure max. 0.5 bar |
Cycle Time | 10 min Fe (II),Fe total dissolved (dilution + 5 min.) 15 min all combined parameters |
Demineralised Water | For rinsing / dilution |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 2 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass Wall section: Galvanised steel,powder coated |
Measurement Method | Colorimetric measurement using TPTZ colour solution,conform with APHA 3500-Fe (B) |
Model | EZ1023 |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Iron Fe(II),dissolved |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 5 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Online colorimetric analysis of dissolved Iron Fe(II) in water
EZ1000 Iron Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Iron Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1023 Iron Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Reagent Container with Fittings (for Buffer Solution) & 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour Solution)
Interferences:
Metal ions like Lead > 10 mg/L, Zinc > 2 mg/L, Nickel > 2 mg/L, Iron > 5 mg/L, Copper > 5 mg/L. Strong oxidising agents, Cyanide, Nitrite, Phosphate (polyphosphate more than orthophosphate), Chromium, Zinc in concentrations exceeding 10 times that of Iron. Bismuth, Cadmium, Mercury, Molybdate, and Silver precipitate Phenanthroline. Polyphosphate must be absent. Large amounts of colour and turbidity interfere. Fats, pil, proteins,surfactants and tar.
Range:
0.01 - 1 mg/L Fe(II)
Optional:
0.002 - 0.1 mg/L
0.005 - 0.25 mg/L
0.005 - 0.5 mg/L
0.08 - 4 mg/L (with internal dilution)
0.16 - 8 mg/L (with internal dilution)
2 - 100 mg/L (with internal dilution)
View Complete Details
Weight | 25 kg |
Power Supply | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Automatic Cleaning | Yes |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 minutes (dilution + 5 min.) |
Demineralised Water | For rinsing |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Interferences | Thallium (III),tin (VI),organic matter may interfere. Fats,oil,proteins,surfactants and tar. |
Lower Limit of Detection (LOD) | less than equal to 1 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Measurement Method | Stripping voltammetry using carbon electrode |
Number of Sample Streams | 1 stream Optional: 1 to 6 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Cadmium,dissolved Cd(II); Lead,dissolved Pb(II) |
Precision | Better than 5% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 1 - 100 micro g/L Cd(II),1 - 100 micro g/L Pb(II) |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Trace metal analysis of dissolved Cadmium Cd(II) + dissolved Lead Pb(II)in water by online voltammetry
The EZ6000 Series of Online Trace Metal Analysers are based on the technology of stripping voltammetry, a sensitive analytical technique that can be automated for the determination of trace levels of metals in water. For many metals the EZ6000 Series boasts limits of quantification in the low ppb range, comparing the technique favorably with AAS or ICP analysis.
Single, multiple and total parameter configurations
Several product sublines with a wealth of combinations are available for determination of trace metals, including the standard single parameter and multi-parameter configurations without digestion. Measurement of complexed or adsorbed metals is possible by means of the configurations with built-in digester. Combinations of metals depend on the choice of working electrode and the priority metals for your application.
Advanced features
The EZ6000 Series build upon tried and tested voltammetry technology used in many clean water applications, in an industrial mainframe with the following prime features:
- Excellent selectivity and sensitivity
- Built-in sample digestion unit (hot acid or UV)
- Smart automatic features
- Standard 4 - 20 mA signal output with alarm processing
- Communication ports supporting connectivity to Modbus
- Higher measuring ranges: internal sample dilution
- Multiple stream analysis
What''s included?
EZ6102 Cadmium & Lead Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and empty Containers for Reagents with Fittings
View Complete Details
Brand | Hach |
Alarm | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 min (dilution + 5 min) |
Demineralised Water | For rinsing / dilution |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 1 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass Wall section: galvanised steel,powder coated |
Measurement Method | Colorimetric measurement at 546 nm using NEDD,conform with standard method ASTM 4500-NO2-A |
Model | EZ1028 |
Number of Sample Streams | 1 stream |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Nitrite |
Power | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP66 |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online colorimetric analysis of Nitrite in water
EZ1000 Nitrite Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Nitrite Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1028 Nitrite Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour Solution)
Interferences:
Ions like Antimony Sb(III), Bismuth, Chloroplatinate, Gold, Iron Fe(III), Lead, Mercury, Metavanadate, Silver can precipitate with Nitrate. Presence of Copper Cu(II) may decompose the diazonium salt which results in a low result.Strong oxidizing agents. Trichloramine results in a false red colour.
Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Range:
1 - 100 µg/L NO2-N
Optional:
8 - 400 µg/L (with internal dilution)
16 - 800 µg/L (with internal dilution)
0.1 - 10 mg/L (with internal dilution)
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 min (dilution + 5 min) |
Demineralised Water | For rinsing / dilution |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 10 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass Wall section: Galvanised steel,powder coated |
Measurement Method | Colorimetric measurement at 505 nm using 4-aminoantipyrine,conform with standard method APHA |
Model | EZ1030 |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Phenol |
Power | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 3% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online colorimetric analysis of Phenol in water
EZ1000 Phenol Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Phenol Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1030 Phenol Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Reagent Container with Fittings (for Buffer Solution) and 1 x empty 2.5L Reagent Container with Fittings (for Colour Solution)
Interferences:
Oxidising agents such as Chlorine, Sulphur compounds like Sulphide. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Range:
0.1 - 2 mg/L Phenol
Optional:
0.01 - 0.25 mg/L
0.025 - 0.5 mg/L
0.025 - 1 mg/L
0.8 - 8 mg/L (with internal dilution)
1.6 - 16 mg/L (with internal dilution)
2 - 200 mg/L (with internal dilution)
View Complete Details
Brand | Hach |
Power | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Weight | 25 kg |
Material | Cabinet: PVC Dilution vessel: borosilicate glass Tubing: Norprene,PFA,PE |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Cleaning | Automatic; frequency freely programmable |
Dilution | Max. 50x dilution Optional: Max. 100x Max.150x Max. 200x Max. 250x |
Drain | 1/4" OD tubing |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Protection Class | IP55 |
Required Fast Loop | 100 - 300 mL/min |
Sample Temperature | Max. 65 DegreeC |
Warranty | 2 years |
Convenient and precise sample dilution up to 1/250 - compatible with EZ Series online analysers
The successful implementation of online analysers in process control strategies could not have been achieved without the development of a new generation of automatic sampling and sample preconditioning systems. The EZ9000 Series are the result of many years of experience in filtration, dilution and settling.
The EZ9700 is an external dilution unit designed for sample dilution in water analysis applications where concentrations of the analyte are so elevated that absorbance readings would be out of range, while any internal sample dilution would not be sufficient to cover the broad measuring range. The unit combines a number of features with ease of use:
- Discontinuous sample dilution system for external dilution up to 1/250
- Robust alternative to internal sample dilution by micropump or dispenser
- Dilution with demineralised water
- Fully controlled by analyser panel PC
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 min (dilution + 5 min.) |
Demineralised Water | For rinsing |
Digital Outputs | Modbus RS485 |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 1 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass Wall section: galvanised steel,powder coated |
Measurement Method | Colorimetric measurement at 800 nm using molybdate,conform with standard method ASTM 4500-SiO2-C |
Model | EZ1034 |
Number of Sample Streams | 1 stream |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Silica |
Power | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 1% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP66 |
Range | 0 - 100 micro g/L Si Optional: 0 - 50 micro g/L |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online colorimetric analysis of Silica in water
EZ1000 Silica Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Silica Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1034 Silica Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and 3 x empty 2.5L Reagent Containers with Fittings (for Colour, Oxalic Acid, Reducing)
Interferences:
Tannin, large amounts of Iron, Sulphide and Phospate interfere. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Certifications | CE compliant / UL certified |
Cycle Time | 10 - 15 minutes |
Demineralised Water | For rinsing / dilution |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 20 mg/L |
Material | Hinged part: Thermoform ABS,door: plexiglass Wall section: Galvanised steel,powder coated |
Measurement Method | Acid-base titration with sulphuric acid,conform with standard method APHA 4500-NH3 |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Sulphate |
Power | 100 - 240 VAC,50/60 Hz,Max. power consumption: 120 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 20 - 200 mg/L SO4 Optional: Internal dispenser dilution (max. factor 100) |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online automatic titration of Sulphate in water
EZ4000 Series Analysers are single-parameter titrators that achieve excellent precision and accuracy. Depending on the parameter of interest, the measuring range and the water matrix the EZ4000 Series may use either potentiometry i.e. acid-base, redox or precipitation titration, where the endpoint is determined by a change in a specific variable, or photocolorimetry, where colour change is used to determine the endpoint of the titration. The high precision dispenser for addition, robust peristaltic pumps for sampling and drain, and carefully designed liquid pathways all add up to the highest performance for industrial and environmental analysis needs.
Results you can rely on
Smart automatic features for validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Sulphate Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ4039 Sulphate Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and empty Containers for Reagents with Fittings
Interferences:
Some metal ions interfere by causing fading or indistinct end points or by stoichiometric consumption of EDTA. Silica > 500 mg/L interferes. Suspended or colloidal organic matter also may interfere with the end point. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Certifications | CE compliant / UL certified |
Cycle Time | 10 - 15 minutes |
Demineralised Water | For rinsing / dilution |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 2 mg/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Measurement Method | Precipitation titration with iodine,conform with standard method APHA 4500-S2 (F) |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Sulphide |
Power | 100 - 240 VAC,50/60 Hz,Max. power consumption: 120 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online, automatic titration of Sulphide in water
State of the art titration platform
The EZ4000 Series Analysers are single-parameter titrators built on an industrial analytical platform. High precision dispensers, robust peristaltic pumps and carefully designed liquid pathways all add up to the highest performance for industrial and environmental analysis needs.
Unique flexibility in titration methods
Every application starts with the basics: the right titrimetric technique for the parameter of interest, the measuring range and the water matrix. Depending on the change in the specific variables, the EZ4000 Series run either acid-base, redox, precipitation or photocolorimetric titration allowing for a unique flexibility.
The EZ4000 Series Sulphide Analysers use precipitation titration. They combine unparalleled expertise in online titration with a set of unique analysis, control and communication features in a compact footprint:
- Wide standard measuring range
- Smart automatic features
- Control and communication via industrial panel PC
- Analogue and digital output options
- Multiple stream analysis (up to 8 streams)
What''s included?
EZ4032 Sulphide Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x Pt Redox Electrode, S7 Connection, 2 x empty 10L Reagent Containers (for Buffer & Na???S???O??? Solution) and 1 x empty 10L Reagent Dark Container with Fittings (for I??? Solution)
Interferences:
Oxidised forms of manganese interfere. Strong oxidising agents such as chlorine, bromine, chlorine dioxide, iodine, permanganate, hydrogen peroxide and ozone. However reduced forms of these components – bromide, chloride, iodide, manganous ion and oxygen – do not interfere. Reducing agents such as organic sulphites also interfere. Fats, oil, proteins, surfactants and tar.
Range:
20 - 1000 mg/L S2-
Optional:
2 - 100 mg/L
5 - 250 mg/L
10 - 500 mg/L
Internal dispenser dilution (max. factor 100)
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC,+- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 DegreeC; pressure max. 0.5 bar |
Cycle Time | 30 min including digestion of 10 min (standard) |
Demineralised Water | For rinsing |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 10 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass Wall section: Galvanised steel,powder coated |
Number of Sample Streams | 1 stream |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Phosphorus,total |
Power | 120 VAC,50/60 Hz Max. power consumption: 440 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 0.01 - 2 mg/L TP |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online, automatic monitoring of Total Phosphorus (TP) in wastewater and general water applications
The EZ7800 Series of Online TP Analysers meet the needs for fast, convenient and reliable monitoring of the regulatory sum parameter Total Phosphorus in municipal and industrial wastewater as well as surface water applications. The EZ7800 Series share similar technology with the EZ7700 Series which monitor Total Nitrogen.
Phosphorus is often synonymous with phosphate but can be present in different forms: orthophosphate (O-phosphate), condensed phosphate (polyphosphate) or organically bonded phosphate. O-phosphate is often the only form that is measured with traditional test kits or even in laboratory, yet the organic form of phosphate can be an important constituent of industrial discharges, often deriving from corrosion control programs or use of fertilisers. In summary, knowing levels of TP can be an important added value to waste water operations.
The EZ7800 Online Total Phosphorus Analyser allows operators of industrial and municipal water works to monitor and control in a convenient way the total portion of phosphorous, if needed combined with a free phosphate measurement. The analyser’s industrial mainframe harnesses a proprietary sample digestion technique combined with a proprietary sample digestion technique combined with seamless operation:
- Full oxidation of all complexed phosphate
- Smart automatic features
- Control and communication via industrial panel PC
- Standard 4 - 20 mA signal output with alarm processing
- Communication supporting Ethernet connectivity to Modbus TCP/IP
- Multiple stream analysis
What''s included?
EZ7800 Total Phosphorus Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and empty Containers for Reagents with Fittings
Interferences:
Arsenicum (V), Chromium (VI), Copper (II) > 10 mg/L, Iron (III) > 10 mg/L, Sulphide > 2 mg/L, and Vanadium (V), Silica > 60 mg/L. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Measurement method:
Colorimetric measurement at 630 nm using ascorbic acid reduction and molybdate colour solution after persulphate digestion in acidic medium, conform with APHA 4500-P
View Complete Details
Weight | 25 kg |
Power Supply | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Certifications | CE compliant / UL certified |
Cycle Time | 10 - 15 minutes |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 10 mg/L |
Material | Hinged part: Thermoform ABS,door: plexiglass Wall section: Galvanised steel,powder coated |
Measurement Method | Acid-base titration |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Volatile fatty acids (VFAs) |
Precision | Better than 3% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 10 - 500 mg/L as acetate equivalent |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Rinsing | With tap water |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Online, automatic monitoring of critical process parameters and process efficiency in anaerobic digesters
A new control alternative for anaerobic digestion
Due to the expensive or time-consuming character of most analysis methods for anaerobic processes, industrial digesters are usually not adequately monitored. Developed specifically for monitoring anaerobic digesters, the EZ7200 Series bring the possibility of implementing new control alternatives to typical operating problems in mid to large scale digesters.
Critical parameter monitoring, online and automatic Anaerobic digesters require monitoring of a specific set of critical parameters in order to obtain optimal production efficiency, compliance and biogas yield. The primary parameter is volatile fatty acids (VFAs), representing the metabolic condition of the anaerobic digester and responding quickly to stress induced changes, combined with bicarbonate and alkalinity.
The EZ7200 Series are easy-to-operate online titrators using a unique and robust method for measuring the critical process parameters in one single run, enabling insight as well as full control over the anaerobic process:
- Direct titration with minimum volatilisation
- Continuous monitoring of the anaerobic process
- Enabling higher loading rate for maximum CH4 production
- Prevention of digester failure due to VFA accumulation
- Easy implementation within a dynamic control strategy
- Easy integration into corporate networks
What''s included?
EZ7200 VFA Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and empty Containers for Reagents with Fittings
Interferences:
Phosphates and similar dissociating ions and non-fatty acids which on acidification from undissociated acids may cause interference. Sulphide may deteriorate some types of pH electrodes. Fats, oil, proteins, surfactants and tar.
Sample Quality:
Maximum particle size 500 µm, < 0.1 g/L
Most applications require the use of an EZ9130 sampling/filtration system.
View Complete Details
Weight | 25 kg |
Brand | Hach |
Alarm | 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Automatic Cleaning | Yes |
Calibration | Automatic, 2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 minutes |
Demineralised Water | For rinsing |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure, vented, min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Interferences | Antimony (III), bismuth (III), organic matter may interfere. Fats, oil, proteins, surfactants and ta |
Lower Limit of Detection (LOD) | less than equal to 10 micro g/L |
Material | Hinged part: Thermoform ABS, door: plexiglass, Wall section: Galvanised steel, powder coated |
Measurement Method | Stripping voltammetry using carbon electrode |
Number of Sample Streams | 1 stream Optional: 1 to 6 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs Modbus TCP/IP |
Parameter | Copper, dissolved Cu(II) |
Power | 100 - 240 VAC, 50/60 Hz, Max. power consumption: 120 VA |
Precision | Better than 5% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 10 - 100 micro g/L Cu(II) |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m, < 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Trace metal analysis of dissolved Copper Cu(II) in water by online voltammetry
The EZ6000 Series of Online Trace Metal Analysers are based on the technology of stripping voltammetry, a sensitive analytical technique that can be automated for the determination of trace levels of metals in water. For many metals the EZ6000 Series boasts limits of quantification in the low ppb range, comparing the technique favorably with AAS or ICP analysis.
Single, multiple and total parameter configurations
Several product sublines with a wealth of combinations are available for determination of trace metals, including the standard single parameter and multi-parameter configurations without digestion. Measurement of complexed or adsorbed metals is possible by means of the configurations with built-in digester. Combinations of metals depend on the choice of working electrode and the priority metals for your application.
Advanced features
The EZ6000 Series build upon tried and tested voltammetry technology used in many clean water applications, in an industrial mainframe with the following prime features:
- Excellent selectivity and sensitivity
- Built-in sample digestion unit (hot acid or UV)
- Smart automatic features
- Standard 4 - 20 mA signal output with alarm processing
- Communication ports supporting connectivity to Modbus
- Higher measuring ranges: internal sample dilution
- Multiple stream analysis
What's included?
EZ6004 Copper Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and empty Containers for Reagents with Fittings
View Complete Details
Brand | Hach |
Parameters | Colour Pt-Co |
Weight | 25 kg |
Power | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Calibration | Automatic,2-point; frequency freely programmable |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Certifications | CE compliant / UL certified |
Cycle Time | 5 min (dilution + 5 min.) |
Demineralised Water | For rinsing |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Interferences | Large amounts of turbidity interfere. Fats,oil,proteins,surfactants and tar. |
Lower Limit of Detection (LOD) | <1 Pt-Co |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: galvanised steel,powder coated |
Measurement Method | Colorimetric measurement at 465 nm,conform with standard method ASTM 2120 B |
Model | EZ1008 |
Number of Sample Streams | 1 stream |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP66 |
Range | 0 - 500 Pt-Co Optional: 0 - 50 Pt-Co 0 - 125 Pt-Co 0 - 250 Pt-Co |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Online analysis of Colour (Platinum-Cobalt Scale) in water
EZ1000 Colour Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Colour Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1008 Colour Analyser, Instruction Manual, 1 x Double Bit Door Key and 1 x Mounting Brackets
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Automatic Cleaning | Yes |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 DegreeC; pressure max. 0.5 bar |
Cycle Time | 10 min (dilution + 5 min) |
Demineralised Water | For rinsing / dilution |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 1 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Model | EZ1009 |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Chromium Cr(VI),dissolved |
Power | 100 - 240 VAC,50/60 Hz,Max. power consumption: 120 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online colorimetric analysis of dissolved Chromium Cr(VI) in water
EZ1000 Chromium Cr(VI) Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Chromium Cr(VI) Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1009 Chromium Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour) and 1 x empty 5L Reagent Container with Fittings (for Buffer Solution)
Measurement method:
Colorimetric measurement at 546 nm using diphenylcarbazide method, conform with standard method APHA 3500-Cr (B)
Range:
5 - 500 µg/L Cr(VI)
Optional:
1 - 50 µg/L Cr(VI)
2 - 125 µg/L Cr(VI)
2.5 - 250 µg/L Cr(VI)
0.08 - 2 mg/L Cr(VI) (with internal dilution)
0.16 - 4 mg/L Cr(VI) (with internal dilution)
0.5 - 50 mg/L Cr(VI) (with internal dilution)
Interferences:
Iron (III), Mercury > 200 mg/L, Molybdenum > 200 mg/L, Vanadium (V) > 5 mg/L.
Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Automatic Cleaning | Yes |
Certifications | CE compliant / UL certified |
Cycle Time | 10 - 15 minutes |
Demineralised Water | For rinsing / dilution |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 5 mg/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Measurement Method | Potentiometric titration with silver nitrate (AgNO3),conform with standard method APHA 4500-Cl (D) |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Chloride |
Power | 100 - 240 VAC,50/60 Hz,Max. power consumption: 120 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online, automatic titration of Chloride in water
EZ4000 Series Analysers are single-parameter titrators that achieve excellent precision and accuracy. Depending on the parameter of interest, the measuring range and the water matrix the EZ4000 Series may use either potentiometry i.e. acid-base, redox or precipitation titration, where the endpoint is determined by a change in a specific variable, or photocolorimetry, where colour change is used to determine the endpoint of the titration. The high precision dispenser for addition, robust peristaltic pumps for sampling and drain, and carefully designed liquid pathways all add up to the highest performance for industrial and environmental analysis needs.
Results you can rely on
Smart automatic features for validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Chloride Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ4006 Chloride Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x mV electrode, 2 x empty 10L Reagent Containers with Fittings (for Cleaning & Buffer Solution) and 1 x empty 10L Reagent Dark Container with Fittings (for AgNO??? Solution)
Interferences:
Bromide, sulphide, iodide ions may interfere. Ferricyanide causes high results and must be removed. Chromate and dichromate interfere and should be reduced to chromic state or removed. Ferric iron interferes if present in an amount substantially higher than the amount of chloride. Chromic ion, ferrous ion and phosphate do not interfere. Fats, oil, proteins, surfactants and tar.
Range:
25 - 500 mg/L Cl-
Optional:
5 - 50 mg/L Cl-
5 - 125 mg/L Cl-
5 - 250 mg/L Cl-
Internal dispenser dilution (max. factor 100)
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 minutes |
Demineralised Water | For rinsing |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Interferences | Thallium (III),tin (VI),organic matter may interfere. Fats,oil,proteins,surfactants and tar. |
Lower Limit of Detection (LOD) | less than equal to 1 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Measurement Method | Stripping voltammetry using carbon electrode |
Number of Sample Streams | 1 stream Optional: 1 to 6 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Cadmium,dissolved |
Power | 100 - 240 VAC,50/60 Hz,Max. power consumption: 120 VA |
Precision | Better than 5% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 1 - 100 micro g/L Cd(II) |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Trace metal analysis of dissolved Cadmium Cd(II) in water by online voltammetry
The EZ6000 Series of Online Trace Metal Analysers are based on the technology of stripping voltammetry, a sensitive analytical technique that can be automated for the determination of trace levels of metals in water. For many metals the EZ6000 Series boasts limits of quantification in the low ppb range, comparing the technique favorably with AAS or ICP analysis.
Single, multiple and total parameter configurations
Several product sublines with a wealth of combinations are available for determination of trace metals, including the standard single parameter and multi-parameter configurations without digestion. Measurement of complexed or adsorbed metals is possible by means of the configurations with built-in digester. Combinations of metals depend on the choice of working electrode and the priority metals for your application.
Advanced features
The EZ6000 Series build upon tried and tested voltammetry technology used in many clean water applications, in an industrial mainframe with the following prime features:
- Excellent selectivity and sensitivity
- Built-in sample digestion unit (hot acid or UV)
- Smart automatic features
- Standard 4 - 20 mA signal output with alarm processing
- Communication ports supporting connectivity to Modbus
- Higher measuring ranges: internal sample dilution
- Multiple stream analysis
What''s included?
EZ6002 Cadmium Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and empty Containers for Reagents with Fittings
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 DegreeC; pressure max. 0.5 bar |
Demineralised Water | For rinsing |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 5 mg/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | COD |
Power | 120 VAC,50/60 Hz,Max. power consumption: 440 VA |
Precision | Better than 5% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 5 - 100 mg/L O2 |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online, automatic, wet-chemical determination of COD values in wastewater and surface water applications
Bridging traditional chemistry with modern analyticsThe EZ7000 Series are wet-chemical COD analysers bringing new levels of automation, reliability and performance in measuring COD values in waste water and surface water. The superior analytical performance is exemplary of their build quality, thanks to the use of high quality components, state of the art wet chemistry and standard smart software features.
Compliance with international standard methods
The analytical mainframe of the EZ7000 Series sets new standards in traditional COD analysis thanks to the flexible architecture, while compliance with international standard methods is assured. Prior to analysis, the sample is oxidised by means of a specific acid solution and heat, in accordance with the standard method applied.
The EZ7000 Series of Online COD Analysers are the answer to the needs of those users who require “true” COD values to quantify organic pollution in various water applications:
- Wet-chemical COD analysis conform standard methods for dichromate or permanganate destruction
- Built-in sample digestion/oxidation unit
- Smart automatic features
- Control and communication via industrial panel PC
- Standard 4 - 20 mA signal output with alarm processing
- Communication ports supporting connectivity to Modbus
- Multiple stream analysis
What''s included?
EZ7000 COD Analyser, Instruction Manual, 1 x Double Bit Door key, 1 x Mounting Brackets, 1 x Redox Pt Electrode, Routine S7 Connection, 1 x empty 10L Reagent Container with Fittings (Mohr''s Salt Solution), 2 x empty 5L Reagent Containers with Fittings (Acid & Dichromate Solution)
Cycle Time:
40 minutes, including oxidation time of 30 minutes.
Remark: standard method for Cr destruction requires 120 minutes.
Interferences:
Chloride > 1 g/L, inorganic reducing agents such as nitrites, sulphides and iron(II) will increase the result, aromatic hydrocarbons and pyridine are not oxidized to any appreciable extent. Some very volatile organic substances may escape the oxidation by evaporation. Straight chain aliphatic compounds are effectively oxidised by the silver sulphate/sulphuric acid solution. Fats, oil, proteins, surfactants and tar.
Measurement method:
Redox titration after oxidation by acid-potassium dichromate solution, conform with ISO 6060 method Or redox titration after oxidation by potassium permanganate solution, conform with ISO 8467 and JIS K0806 methods.
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 DegreeC; pressure max. 0.5 bar |
Cycle Time | 15 min (dilution + 5 min.) |
Demineralised Water | For rinsing / dilution |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | 100 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: galvanised steel,powder coated |
Measurement Method | Colorimetric measurement at 405 nm using Azomethine-H |
Model | EZ1004 |
Number of Sample Streams | 1 stream |
Output | Modbus RS485,Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Boron B(III),dissolved |
Power | 100 - 240 VAC,50/60 Hz,Max. power consumption: 120 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP66 |
Reagent Requirements | Keep refrigerated. |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online colorimetric analysis of dissolved Boron in water
EZ1000 Boron Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Boron Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1004 Boron Analyser, Instruction Manual, 1 x Double Door Bit Key, 1 x Mounting Brackets, 1 x empty 5L Reagent Container with Fittings (for Buffer Solution) and 1 x empty Plastic Dark 5L Container with Fittings (for Colour Solution)
Interferences:
Aluminium, Iron, Copper, Titanium and Zinc ions in high concentrations may interfere. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Range:
100 - 500 µg/L B(III)
Optional:
800 - 2000 µg/L (with internal dilution)
1600 - 4000 µg/L (with internal dilution)
10000 - 50000 µg/L (with internal dilution)
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 minutes |
Demineralised Water | For rinsing |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than 1 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Measurement Method | Stripping voltammetry using gold electrode |
Model | EZ6000 |
Number of Sample Streams | 1 stream Optional: 1 to 6 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Arsenic,dissolved As(III) |
Power | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 5% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 1 - 20 micro g/L As(III) |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Trace metal analysis of dissolved Arsenic As(III) in water by online voltammetry
The EZ6000 Series of Online Trace Metal Analysers are based on the technology of stripping voltammetry, a sensitive analytical technique that can be automated for the determination of trace levels of metals in water. For many metals the EZ6000 Series boasts limits of quantification in the low ppb range, comparing the technique favorably with AAS or ICP analysis.
Single, multiple and total parameter configurations
Several product sublines with a wealth of combinations are available for determination of trace metals, including the standard single parameter and multi-parameter configurations without digestion. Measurement of complexed or adsorbed metals is possible by means of the configurations with built-in digester. Combinations of metals depend on the choice of working electrode and the priority metals for your application.
Advanced features
The EZ6000 Series build upon tried and tested voltammetry technology used in many clean water applications, in an industrial mainframe with the following prime features:
- Excellent selectivity and sensitivity
- Built-in sample digestion unit (hot acid or UV)
- Smart automatic features
- Standard 4 - 20 mA signal output with alarm processing
- Communication ports supporting connectivity to Modbus
- Higher measuring ranges: internal sample dilution
- Multiple stream analysis
What''s included?
EZ6000 Arsenic Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x Counter Electrode - Platina, 1 x Working Electrode - Gold, 1 x Reference Electrode - Ag/AgCl, 1 x empty 10L Reagent Container with Fittings (H2SO4 Solution) and 1 x empty 5L Reagent Container with Fittings (Buffer Solution) and 2 x empty 1L Reagent Container with Fittings (Reference Blank & Reference As Solution)
Interferences:
Iodide, organic matter, copper Cu(II) > 30 µg/L, iron Fe(III) >20 mg/L, various metals in mg/L levels may interfere. Fats, oil, proteins, surfactants and tar.
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Certifications | CE compliant / UL certified |
Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 DegreeC; pressure max. 0.5 bar |
Cycle Time | 10 - 15 minutes |
Demineralised Water | For rinsing / dilution |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 10 mg/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Measurement Method | Acid-base titration with sulphuric acid,conform with standard method APHA 4500-NH3 |
Model | EZ4005 |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Ammonium |
Power | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online automatic titration of Ammonium in water
EZ4000 Series Analysers are single-parameter titrators that achieve excellent precision and accuracy. Depending on the parameter of interest, the measuring range and the water matrix the EZ4000 Series may use either potentiometry i.e. acid-base, redox or precipitation titration, where the endpoint is determined by a change in a specific variable, or photocolorimetry, where colour change is used to determine the endpoint of the titration. The high precision dispenser for addition, robust peristaltic pumps for sampling and drain, and carefully designed liquid pathways all add up to the highest performance for industrial and environmental analysis needs.
Results you can rely on
Smart automatic features for validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Ammonium Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ4005 Ammonium Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x pH Electrode, Routine S7 Connection,1 x empty 5L Reagent Container with Fittings (for H???SO??? Solution) and 1 x empty 10L Reagent Container with Fittings (for NaOH Solution)
Interferences:
Soaps, oily matter, suspended solids or precipitates may coat the glass electrode and cause a sluggish response. Allow additional time between titrant additions to let the electrode come to equilibrium or clean the electrodes occasionally. Alkaline compounds may interfere with the titration.
Range:
100 - 5000 mg/L NH???-N
Optional:
10 - 500 mg/L NH???-N
25 - 1250 mg/L NH???-N
50 - 2500 mg/L NH???-N
View Complete Details
Model Name/Number | EZ1001 |
Weight | 25 kg |
Power Supply | 100 - 240 VAC,50/60 Hz,Max. power consumption: 120 VA |
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +- 4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 DegreeC; pressure max. 0.5 bar |
Cycle Time | 10 min (dilution + 5 min) |
Demineralised Water | For rinsing / dilution |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Interferences | Large amounts of colour and turbidity interfere. Fats,oil,proteins,surfactants and tar. |
Lower Limit of Detection (LOD) | less than equal to 10 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Measurement Method | Colorimetric measurement using pyrocatechol violet method at 578 nm |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Parameter | Aluminium Al(III),dissolved |
Precision | Better than 2% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 5 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Online colorimetric analysis of dissolved Aluminium in water
EZ1000 Aluminium Analysers achieve excellent precision and accuracy. At the heart of the colorimeter there is a compact photometer assembly developed especially for the EZ Series. Consumption of reagents is reduced by low volume analysis, yet high sensitivity is assured by a long optical path length. The limit of detection is in the low µg/L range.
Results you can rely on
Smart automatic features for calibration, validation, priming and cleaning are embedded in the controller software and contribute to analytical performance, maximised uptime and negligible operator invervention. Precision micropumps dose all reagents. Sample lines and analysis vessel are cleaned with demineralised water to eliminate cross contamination between samples. Electronic and wet-chemical part of the analyser are strictly separated. A transparent door allows for instant visual inspection of the wet part.
Flexibility that meets your needs
EZ Series Aluminium Analysers come in an attractive, ergonomic mainframe with a compact footprint. All hardware is controlled by the integrated industrial panel PC. The modular build allows for the analyser to match your application and operational needs.
- The standard measuring range can be narrowed by a different calibration range or extended via internal dilution options.
- Analogue and digital output options
- Multiple stream analysis for up to 8 sample streams
What''s included?
EZ1001 Aluminium Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and 3 x empty 2.5L Reagent Containers with Fittings (for Mixed Reagent, Colour and Buffer Solution)
Range:
10 - 150 µg/L Al(III)
Optional:
10 - 75 µg/L
80 - 600 µg/L (with internal dilution)
160 - 1200 µg/L (with internal dilution)
10000 - 15000 µg/L (with internal dilution)
View Complete Details
Type Of Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Certifications | CE compliant / UL certified |
Cycle Time | 10 - 15 minutes |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 10 mg/L |
Measurement Method | Acid-base titration |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Volatile fatty acids (VFAs),bicarbonate,total alkalinity,partial alkalinity |
Power | 100 - 240 VAC,50/60 Hz,Max. power consumption: 120 VA |
Precision | Better than 3% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | VFAs 10 - 500 mg/L as acetate equivalent; Bicarbonate 1 - 50 meq/L or 5000 mg/L as CaCO3; |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Rinsing | With tap water |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 500 micro m,< 0.1 g/L |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Online, automatic monitoring of critical process parameters and process efficiency in anaerobic digesters
A new control alternative for anaerobic digestion
Due to the expensive or time-consuming character of most analysis methods for anaerobic processes, industrial digesters are usually not adequately monitored. Developed specifically for monitoring anaerobic digesters, the EZ7200 Series bring the possibility of implementing new control alternatives to typical operating problems in mid to large scale digesters.
Critical parameter monitoring, online and automatic
Anaerobic digesters require monitoring of a specific set of critical parameters in order to obtain optimal production efficiency, compliance and biogas yield. The primary parameter is volatile fatty acids (VFAs), representing the metabolic condition of the anaerobic digester and responding quickly to stress induced changes, combined with bicarbonate and alkalinity.
The EZ7200 Series are easy-to-operate online titrators using a unique and robust method for measuring the critical process parameters in one single run, enabling insight as well as full control over the anaerobic process:
- Direct titration with minimum volatilisation
- Continuous monitoring of the anaerobic process
- Enabling higher loading rate for maximum CH4 production
- Prevention of digester failure due to VFA accumulation
- Easy implementation within a dynamic control strategy
- Easy integration into corporate networks
What''s included?
EZ7250 VFA, Bicarbonate & Alkalinity Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x pH Electrode, Routine S7 Connection, 1 x empty 2.5L Reagent Container with Fittings (Anti-foam Solution) and 2 x empty 10L Reagent Containers with Fittings (H???SO??? & NaOH Solution)
Interferences:
Phosphates and similar dissociating ions and non-fatty acids which on acidification from undissociated acids may cause interference. Sulphide may deteriorate some types of pH electrodes. Fats, oil, proteins, surfactants and tar.
View Complete Details
Brand | Hach |
Model Name/Number | EZ7300 |
Parameters | ATP |
Weight | 30 kg |
Power | 100 - 240 VAC,50/60 Hz,Max. power consumption: 120 VA |
Calibration | Automatic,2-point; frequency freely programmable |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 7 - 23 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Certifications | CE compliant / UL certified |
Cooling Water | Flow rate approx. 5 L/h; temperature max. 30 DegreeC; pressure max. 0.5 bar |
Cycle Time | 7 - 10 minutes incl. sample lysis |
Demineralised Water | For rinsing |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Lower Limit of Detection (LOD) | less than equal to 0.05 pg/mL (0.1 pM) ATP |
Material | Hinged part: Thermoform ABS,door: plexiglass,Wall section: Galvanised steel,powder coated |
Number of Sample Streams | 1 stream Optional: 1 to 8 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Precision | Better than 4% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 0.5 - 200 pg/mL |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | Maximum 3 bar for direct injection or by external overflow vessel via the grab sample pump |
Sample Temperature | 5 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Online monitoring of microbial activity in process water and drinking water applications
The first online microbiology analyser complying with standard method ASTM 4012-81
The EZ7300 Series monitor total bacterial and pathogen load in water by measuring portions of ATP (adenosine triphosphate) of any type of microbial microorganism present in the water sample i.e. bacteria (pathogenic and non-pathogenic), microalgae and protozoa. The analyser can be used as an Early Warning System in various applications with focus on water safety, when high ATP values indicate a potential risk in surpassing a threshold value of microorganisms in the past or in the near future.
Determination of total, intracellular and free ATP levels
Contrary to commonly available manual or semi-automated methods, the EZ7300 Series guarantees complete ATP recovery by quantifying different ATP portions in the sample. Operators now can access data on both extracellular (free) and intracellular ATP values, in order to differentiate living biomass from the non-living.
Advanced features
The EZ7300 Online Microbiology Analyser provides results within minutes and an objective, measurable basis for actions against sudden changes in microbial levels in your process:
- Complying with ASTM D4012-81
- Complete ATP recovery
- No bias from the composition of the growth medium such as with plate counting
- Low cost of analysis relative to a large number of results
- Smart automatic features
- Low maintenance, easy replaceable reagent kit
- Multiple stream analysis
What''s included?
EZ7300 ATP Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 2 x empty 5L Reagent Container with Fittings (NaOH & HCl Solution) and 3 x Screwcap/Fittings/Reference1/Reference2
Interferences:
High concentrations of Hg2+, Cu2+, Zn2+, Cd2+, Fe2+. Total salt concentrations higher than 1 g/L. pH lower than 5.5 and higher than 8.
Measurement method:
Determination of adenosine triphosphate (ATP) by means of chemiluminescent reaction using luciferin and luciferase, conform with standard method ASTM D4012-81
Reagent Requirements:
Keep between 4 - 8 °C during operation, shielded from light. For prolonged storage, store at -20 °C in a dark environment.
View Complete Details
Brand | Hach |
Alarm | 1 x malfunctioning,4 x user-configurable,max. 24 VDC/0.5 A,potential free contacts |
Ambient Temperature | 10 - 30 DegreeC +-4 DegreeC deviation at 5 - 95% relative humidity (non-condensing) |
Calibration | Automatic,2-point; frequency freely programmable |
Certifications | CE compliant / UL certified |
Cycle Time | 10 minutes |
Demineralised Water | For rinsing |
Dimensions | 690 mm x 465 mm x 330 mm (H x W x D) |
Drain | Atmospheric pressure,vented,min. Dia. 64 mm |
Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm2 |
Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
Interferences | Copper (II) > 100 micro g/L,organic matter may interfere. Fats,oil,proteins,surfactants and tar. |
Lower Limit of Detection (LOD) | less than equal to 10 micro g/L |
Material | Hinged part: Thermoform ABS,door: plexiglass Wall section: Galvanised steel,powder coated |
Measurement Method | Stripping voltammetry using carbon electrode |
Number of Sample Streams | 1 stream Optional: 1 to 6 streams |
Output | Modbus RS485 Optional: Active 4 - 20 mA max. 500 Ohm load,1 to 8 outputs Modbus TCP/IP |
Parameter | Zinc,dissolved Zn(II) |
Power | 100 - 240 VAC,50/60 Hz Max. power consumption: 120 VA |
Precision | Better than 5% full scale range for standard test solutions |
Protection Class | Analyser cabinet: IP55 / Panel PC: IP65 |
Range | 10 - 100 micro g/L Zn(II) |
Reagent Requirements | Keep between 10 - 30 DegreeC |
Sample Flow Rate | 100 - 300 mL/min |
Sample Pressure | By external overflow vessel |
Sample Quality | Maximum particle size 100 micro m,< 0.1 g/L; Turbidity < 50 NTU |
Sample Temperature | 10 - 30 DegreeC |
Validation | Automatic; frequency freely programmable |
Warranty | 2 years |
Weight | 25 kg |
Trace metal analysis of dissolved Zinc Zn(II) in water by online voltammetry
The EZ6000 Series of Online Trace Metal Analysers are based on the technology of stripping voltammetry, a sensitive analytical technique that can be automated for the determination of trace levels of metals in water. For many metals the EZ6000 Series boasts limits of quantification in the low ppb range, comparing the technique favorably with AAS or ICP analysis.
Single, multiple and total parameter configurations
Several product sublines with a wealth of combinations are available for determination of trace metals, including the standard single parameter and multi-parameter configurations without digestion. Measurement of complexed or adsorbed metals is possible by means of the configurations with built-in digester. Combinations of metals depend on the choice of working electrode and the priority metals for your application.
Advanced features
The EZ6000 Series build upon tried and tested voltammetry technology used in many clean water applications, in an industrial mainframe with the following prime features:
- Excellent selectivity and sensitivity
- Built-in sample digestion unit (hot acid or UV)
- Smart automatic features
- Standard 4 - 20 mA signal output with alarm processing
- Communication ports supporting connectivity to Modbus
- Higher measuring ranges: internal sample dilution
- Multiple stream analysis
What''s included?
EZ6010 Zinc Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and empty Containers for Reagents with Fittings
View Complete Details