Trust Seal VerifiedParameters Measured | SPO2, NIBP, PR |
Type of display | LCD |
Suitable For | Neonatal, Pediatric, Adult |
Brand | Contec |
Model | CMS5100 |
Weight | 1.6 kg |
Voltage | 220 V |
Frequency | 50 Hz |
Dimension | 190 mm(L)x162 mm(W)x240 mm(H) |
CMS5100 Contec Patient Monitor adopts Oscillometry for NIBP measuring, Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR) can be accurately measured. Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for hospitals, community medical treatment and family
Features
- Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.
- Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.
- Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
- Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.
- With user-friendly interface.
- Display with 2.8' (320240) color TFT LCD and red and yellow highlight LED.
- Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set. Unique Flash memory, storage for up to 2000 NIBP data and 78000 SpO2 data.
- Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour.
Performance
- NIBP
1)Measurement mode: manual/auto/continuous
2)Measurement interval in auto mode: 1, 2, 3, 4, 5, 5×n(n=2, 3, 4...51) min.
3)Resolution: 1 mmHg
4)Accuracy: max mean error: ±5 mmHg; max standard deviation: 8 mmHg.
5)Overpressure protection: dual protection for both software and hardware
6)Others: reset, self-testing and accuracy testing of static pressure
7)Measurement range:
Adult
- SYS 40 mmHg~270 mmHg
- MAP 20 mmHg~235 mmHg
- DIA 10 mmHg~215 mmHg
Pediatric:
- SYS 40 mmHg~200 mmHg
- MAP 20 mmHg~165 mmHg
- DIA 10 mmHg~150 mmHg
Neonate:
- SYS 40 mmHg~135 mmHg
- MAP 20 mmHg~110 mmHg
- DIA 10 mmHg~100 mmHg
Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the saturation of blood oxygen.
1)Measurement range: 0 %~100 %
2)Alarm range: 0 %~100 %
3)Resolution: 1 %
4)Accuracy: 70 %~100 %, ±2 %; below 70 % unspecified.
3. PR
Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the pulse rate.
1)Measurement range: 25 bpm~250 bpm
2)Alarm range: 25 bpm~250 bpm
3)Resolution: 1 bpm
4)Accuracy: ±2 bpm or ±2 %, whichever is greater
4 Safety and Power supply
1)Safety classification: Class I equipment, type BF defibrillation-proof applied part
Accessories:
1)User Manual 1pc (1 GB only on request for other Language)
2)Power cord 1pc
3)Power adapter 1pc
4)SpO2 sensor 1pc
5)Adult NIBP cuff 1pc
6)NIBP extension tube 1pc
View Complete Details
HSN CodeHSN Description
1904Prepared foods obtained by the swelling or roasting of cereals or cereal products (for example, corn flakes); cereals (other than maize (corn) ) in grain form or in the form of flakes or other worked grains (except flour, groats and meal), pre-cooked, or otherwise prepared, not elsewhere specified or included
30Pharmaceutical products
8509Electro-mechanical domestic appliances, with self contained electric motor, other than vacuum cleaners of heading 8508.
9018Instruments and appliances used in medical, surgical, dental or veterinary sciences, including scientigraphic apparatus, other electromedical apparatus and sight-testing instruments electro-diagnostic apparatus (including apparatus for functional exploratory examinations or for checking physiological parameters)
94Miscellaneous manufactured articles - (chapter 94 – 96) – section xx
- Developed and Managed by IndiaMART InterMESH Limited