VRV and VRF System
Brand | Daikin |
Refrigerant | 5.9Kg (Charge) |
Inverter Technology | Yes |
Airflow, CFM | 119 m3/min |
Cooling Capacity | 54600 Btu/h |
Model Name/Number | RXQ6ARY6 |
Color | Ivory white (5Y7.5/1) |
Size/Dimension | 1657x930x765 mm |
Sound Level | 56 dB(A) |
Power Supply | 3 Phase, 380 - 415 V, 50 Hz |
Capacity Control | 25-100% |
Compressor Type | Hermetically Sealed Scroll Type |
Number of Compressor | 1 |
Weight | 165 Kg |
Refrigerant Type | R410A |
Piping Connection | Liquid- Phi 9.5mm, Gas- Phi 19.1mm |
First launched in Japan in 1982, the daikin VRV X system has been embraced by the world markets for over three decades. Now, we at daikin introduce the next generation VRV X system to reinforce our industry leadership. The system now offers an enhanced line-up to meet an ever widening variety of needs, while improving energy savings, comfort and ease of installation.
The VRV X is the most advanced airconditioning system in the world and is ideal for large and small spaces.
VRT-Variable Refrigerant Temperature in Indoor Unit (IDU) and Outdoor Unit (ODU)
4D Inverter Technology:
Improved realiability by introducing Daikin 3 Phase capacitor less 4D Inverter Technology
4D means- Direct inverter
- Dynamic
- Drive
- High Energy Density
Direct conversion circuit which eliminates the electrolytic capacitor and minimize the reactor size
Dynamic waveform control that suppresses the resonance phenomenon generated by miniaturizing parts
Drive technology: High Density integration of parts on small printed circuit board
Excellent Performance: Refrigerant cooling technology, ensures stability of PCB temperature
- Improves reliability at high ambient temperature
- It is possible to cool the inverter power module stability even at high ambient temperature. This helps to keep air conditioning capacity and also ensures efficient and reliable operation.
Optimised operation efficiency:
- The automatic refrigerant charge function automatically determines the optimal amount of refrigerant to be charged.
- This function prevents a capacity shortage or energy loss due to excessive or insufficient refrigerant.
View Complete Details
Mitsubishi VRF System
Rs 50,000 / TonGet Latest Price
Brand | Mitsubishi |
Cooling Capacity Range | 25.2kW to 246kW |
Voltage (V) | 380V |
Heating Capacity Range | 27kW to 276kW |
Dimension | 1650x920x740 mm |
Sound Pressure | 57 dB |
Refrigerant Piping Diameter | 9.52 mm |
Frequency | 50-60 Hz |
Phase | 3 |
Backed by a rich industrial experience, we are engaged in offering a commendable array of Mitsubishi VRF System.
View Complete Details
Tonnage | 8 HP |
Brand | Trane |
Refrigerant | R410A |
Airflow, CFM | 12000 m3/h |
Model Name/Number | TMR080ADB |
Power Supply | 380~415V-50Hz-3ph |
Cooling Capacity | 25.2 kW |
Heating Capacity | 27.4 kW |
IPLV | 8.70 |
Max. No. Of Connectable Indoor Units | 12 |
Dimensions | 1620x970x796 mm |
Weight | 208 Kg |
Fan Max. Static Pressure | 85 Pa |
Refrigerant Charging amount | 10 Kg |
Chiller Oil Type | FV-68H |
Connecting Pipe | Liquid- Phi 12.7mm(Flare connection), Gas- Phi 22.2mm(Braze connection) |
For more than 100 years, Trane has been making buildings better, and now Trane is at an important strategic point in its history. We aim to continue making buildings better by Going beyond the building as we have gone beyond our legacy of being one of the world's leading HVAC companies, to also being thought of as a leader in services, connected buildings, and energy and building management
IPLV is calculated on the basis of testing the operating efficiency of the air conditioning unit under four different conditions.It not only reflects the multi-split system's operating efficiency under part-load conditions, but also brings about a unified test method, thus being able to demonstrate the multi-split system's energy saving property in a more reasonable manner.Unlike traditional A/c systems, VRF systems are advanced and can match load requirement and give much higher efficiency at part loads.For such systems, an efficiency calculation is available – IPLV (Integrated Part Load Value). This measure considers variation of loads to calculate realistic efficiency of a VRF system.Genyue5+ , 5th Generation VRF , offers part load performance upto 8.7* IPLV exceeding standard VRF systems performance currently available in the market.
All Inverter Compressor System Greatly Boosts Performance
- Secrets Of The More Comfortable All Variable Speed System
- The GEN YUE series performance is substantially upgraded, and the inverter compressor effectively improves the system's self-adaptive adjusting capacity, enabling the system to reach the optimal operating state point of dynamic equilibrium and flexibly adjust output in line with load changes. For example, the 30HP system has two compressors for each module, so totally there are four inverter compressors.
On-demand Output Ensures High Efficiency And Energy Saving
- All variable speed system : The inverter compressors are simultaneously activated according to actual air conditioning needs, and they can fully meet the actual needs and enable on-demand output due to its adjustable capacity.
- Non-variable speed system : As the output is not controllable, it is usually in excess of the demand at first, and then slowly approaches to the actual need, which inevitably causes energy waste.
Precise Temperature Control, Stable And ComfortableAfter the target room temperature is set, the air conditioner activates to make the room temperature approaching to the set value. A non-variable speed air conditioning system will stop operation immediately when reaching the set temperature, and starts again when the temperature deviates from the target to a certain extent, which will inevitably produce evident room temperature change and thus compromise perceived comfort level.When the room temperature reaches the set value, an inverter air conditioning system will adjust output by changing the speed of compressors, so the system will keep running to avoid temperature fluctuation in the room, thus ensuring a higher comfort level
DC Brushless Fan Motor With Low Noise And High Efficiency
Compact Structure, More Efficient Under Low Load OperationThe outdoor unit features brushless DC motor and compact structure, which can optimize the operating state of the unit under different conditions and greatly improve the operating efficiency at low load.
Absolute Comfort:
- Intelligent Defrosting, Effectively Extending Heating Time
View Complete Details
Panasonic VRF System
Rs 40,000 / UnitGet Latest Price
Brand | Panasonic |
Refrigerant | R 410A |
Inverter Technology | Yes |
Star Rating | 5 |
Operating Voltage | 380V |
Design Pressure | 35Pa |
Heating Mode Temperature | -20 to 18 Deg C WB |
Cooling Mode Temperature | -10 to 46DegC DB |
Refrigerant Chargeless | Up to 50m |
Diversity Ratio | 50-130% |
As per the increasing and altering demands of our valued customers, we offer an innovatively developed Panasonic VRF System.